Tender For Comprehensive Repairs To Flooring, Plastering, Plinth Protection, Rcc Chajjas, Tiling Works And Sanitary Fittings To Certain Md/Otm Accn At Ins Valsura, Jamnagar, jamnagar-Gujarat

Military Engineer Services-MES has published Tender For Comprehensive Repairs To Flooring, Plastering, Plinth Protection, Rcc Chajjas, Tiling Works And Sanitary Fittings To Certain Md/Otm Accn At Ins Valsura, Jamnagar. Submission Date for this Tender is 01-07-2023. Shed Construction Tenders in jamnagar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

38078019
Corrigendum : Tender For Comprehensive Repairs To Flooring, Plastering, Plinth Protection, Rcc Chajjas, Tiling Works And Sanitary Fittings To Certain Md/Otm Accn At Ins Valsura, Jamnagar
Open Tender
Indian
Gujarat
jamnagar
01-07-2023

Tender Details

Comprehensive Repairs To Flooring, Plastering, Plinth Protection, Rcc Chajjas, Tiling Works And Sanitary Fittings To Certain Md / Otm Accn At Ins Valsura, Jamnagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jun-2023 Date Corrigendum Date 01-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 93000.0 /-
Tender Value
INR 46.50 Lakhs /-

BOQ Items

Name of Work: Comprehensive repairs to Flooring, Plastering, Plinth Protection, RCC Chajjas, Tiling Works and Sanitary Fittings to certain Md/OTM accn at INS Valsura, Jamnagar
Sl. No. Item Description
1Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
2Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
3Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (above or below ground level) and removal of entire debris as ordered outside MoD land complete all as directed.
4Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
5Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MD land complete all as directed.
6Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
7Dismantling of Asbestos cement Corrugated or semi corrugated sheets etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris tooutside MoD land and depositing where directed complete all as specified and as directed.
8Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stackingserviceable tiles at site andremoval of entire debris as ordered outside MoD land complete all as specified and as directed.
9M&L for factory madepre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed.
10M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.
11M&L for RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in chajja, roof projection etc in any description up to 6 metre height including necessary formwork and scarffolding complete all as specified and as directed. Note: (i) Quoted rate shall deemed to be inclusive of form work, scaffolding, safety belt etc. (ii) Reinforcement shall be measured and paid for separately.
12Supply only Integral Water Proofing Compound (ISI Marked).
13S&F GI chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. (Note: Weight of GI chicken wire mesh shall be 140 to 180 grams /Sqm)
14M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
15S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410 W (Gde E-250) quality-A complete all as specified and as directed.
16S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed.
17M&L for expanded metal weight not exceeding 4 Kgs per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed.
18Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets and S&F new 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including galvanised iron powder coated (white) snap Grid of size 600x600 mm with main "T" and cross "T" having web 25mm, flange 35mm, thickness 0.70mm, wall angle having web/flange 25mm each, 0.70mm thick fixed with soft cleats having web 25mm, flange 25mm and thickness 1.8mm using4mm dia GI wire and level clip @ 1200mm centre to centre with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer"s instructions with & including two coats of oil emulsion distemper (OBD) over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of ceiling work including testing on completion as ordered complete all as specified & as directed.
19S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
20S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ cladding to walls, ridges, gutters, valleys etc. fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
21M&L for 75 mm thick plain cement conctere 1:3:6,type C1 (using 20 mm graded crushedstone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall belaid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
22M&L for 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in levelling course of floor finishes complete all as specified and as directed.
23M&L for 18 to 20mm thick machine cut mirror polished Kota stone slab of minimum size 550 x 550mm, laid in floors over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. Note : Quoted rate shall deemed to be inclusive of cement screed bed/bedding layer.
24M&L for 18 to 20mm thick machine cut mirror polished Kota stone slab on vertical surfaces such as riser of steps, skirting, dado and pillar, laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. Note : Quoted rate shall deemed to be inclusive of rendering (as screed bed).
25M&L for double charged vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (shade & pattern as approved by GE), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
26M&L for double charged vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (shade & pattern as approved by GE), area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
27M&L for double charged vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (shade & pattern as approved by GE), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4, size of tiles as directed by GE to match the size of vitrified tiles provided in floor under respective item in this Schedule, complete all as specified and as directed.
28M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
29M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
30M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes for Srl items Nos 25 to 30: (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got appproved from GE before incorporation in the work.
31M&L for 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
32M&L for 18 to 20 mm thick Green Marble (best quality) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of Marble over & including 20mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
33Cleaning the entire terrazo tiles/ Kota Stone surface by removing stains marks etc including machine grinding & mirror polishing to entire satisfaction of Engineer-in-Charge complete all as directed. (Note: In case where machine grinding is not feasible hand grinding is permitted only after written approval from Engineer-in-Charge).
34M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
35M&L for rendering 20mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls in patches and scattered places mixed with WPC @ minimum 2% by weight of cement or as per manufacturer"s instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as "Supply only".
36M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling in patches and scattered places finished even and smooth without using extra cement complete all as specified and as directed.
37M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
38M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty complete all as specified & as directed.
39M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
40M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
41M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement based paint of approved shade/tint over a coat of alkali resistant priming paint over & including a coat of 1mm thick white cement based wall care putty on walls complete all as specified and as directed.
42M&L for two coats of 1st quality synthetic enemal paint of approved tint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surfaces complete all as directed.
43Taking down or up damaged/ old GI pipe of 15 mm bore and S&F new 15 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
44Taking down or up damaged/ old GI pipe of 20 mm bore and S&F new 20 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
45S&F in repairs ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe or brass ferrule of 20 mm bore and fixed (minimum weight 210 gms) complete all as specified and as directed..
46S&F in repairs 15mm bore bib tap with wall flange, fancy type, cast copper alloy, chromium plated screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6506 or equivalent in makes mentioned in Appendix "B" here-in-after.
47S&F in repairs 15 mm bore bib tap long nose with wall flange, fancy type, cast copper alloy, chromium plated, long shank screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6509 or equivalent in makes mentioned in Appendix "B" here-in-after.
48S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange and aerator, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6512 or equivalent in makes mentioned in Appendix "B" here-in-after.
49S&F in repairs health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe and wall hook mounted type complete. Make:Prayag Cat No. BEA-85 or equivalent in makes mentioned in Appendix "B" here-in-after.
50S&F in repairs 15 mm bore pillar taps, fancy type, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, with or without lettered "Hot" or "Cold" screwed for iron pipe complete all as directed. Make : Prayag CatNo 6502 or equivalent in makes mentioned in Appendix "B" here-in-after.
51S&F in repairs 15 mm bore bib tap sink cock regular spout with flange, fancy type, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, screwed for iron pipe complete all as directed. Make: Prayag CatNo. 6816 or equivalent in makes mentioned in Appendix "B" here-in-after.
52S&F in repairs chromium plated 100mm over head ABS shower round with 225mm SS Arms & Flange, swivel joints fixing to steel pipes etc complete all as directed. Make : Prayag CatNo BS-65 or equivalent in makes mentioned in Appendix "B" here-in-after.
53S&F in repairs concealed type stop valve with wall flange 15 mm bore of pipe, brass chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. Make: PrayagCat No 6518 or equivalent in makes mentioned in Appendix "B" here-in-after.
54S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. 6510 or equivalent in makes mentioned in Appendix "B" here-in-after.
55S&F in repairs 15 mm bore brass, chromium plated, sink mixer wall mounted with 170mm long swivel spout, connecting legs and wall fange, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. Make: Cera Cat No. F2008501 or equivalent in makes mentioned in Appendix "B" here-in-after.
56S&F in repairs 15 mm bore, brass, chromium plated, wall mixer with L bend and one for shower rose, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe complete all as directed. Make: Prayag Cat No. 6675 or equivalent in makes mentioned in Appendix "B" here-in-after.
57S&F in repairs 15 mm bore, brass, chromium plated, central hole WHB mixer W/O pop up for hot and cold water mixing, screwed for iron pipe complete all as directed. Make: Prayag Cat No. 6851 or equivalent in makes mentioned in Appendix "B" here-in-after.
58S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 50cm long between flanges complete all as directed. Make : Prayag Cat No BA-1S or equivalent in makes mentioned in Appendix "B" here-in-after.
59S&F in repairs CP brass towel ring fixed with and including CP brass screws and plastic cleats complete. Make: Cera cat No. F5001105 or equivalent in makes mentioned in Appendix "B" here-in-after.
60S&F in repair CP brass towel rack 600mm (24") long including brass screws fixed complete all as specified and as directed. Make: Prayag Cat No. BA-03 or equivalent in makes mentioned in Appendix "B" here-in-after.
61S&F in repairs CP Brass toilet paper holder with flap guard complete all as specified and as directed. Make: Cat Part No BA-08 of Prayag or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
62S&F in repairs glass Shelf 500 x 125 mm with brass brackets fixed on wall with PVC rawl plug & cadmium plated brass screws complete all as specified and as directed. Make : Cat Part No BEA-45 of Prayag or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
63S&F in repairs bathroom cabinet mirror (400x500mm) including fixing screws complete all as specified and as directed. Make: Prayag Cat No. 554 or equivalent in makes mentioned in Appendix "B" here-in-after.
64S&F in repairs 600mm x 450mm looking mirror of selected quality glass not less than 5.5mm thick, mounted on 6mm thick AC building board or commercial plywood including aluminium framing and fixed to PVC rawl plugs with chromium plated brass screws and cup washers complete all as specified.
65S&F in repairs 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, fixed to wall/ ceilings or in floors etc. complete all as directed.
66S&F in repairs 32mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement fixed to walls and ceilings or laid in floors complete all as specified and as directed.
67S&F in repairs 20mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement fixed to walls and ceilings or laid in floors complete all as specified and as directed.
68S&F in repairs grating square 140 mm size of stainless steel and fixed complete all as specified & as directed.
69S&F in repairs PVC connections 15mm dia, 450mm long with PTMT nuts & washers at both ends.
70S&F in repairs PVC flexible waste pipe for 32mm dia waste coupling complete all as specified and as directed
71S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
72S&F110 mmbore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
73S&F 110 mm bore PVC (SWR)junction single (single T) equal or unequal with access doorincluding jointing the same with solvent cement complete all as specified & as directed.
74S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
75S&F in repairs vitreous china oval shape counter/ table topwash hand basin (white) of size 410mm x 340mm x 150mm with & including 32 mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified & as directed. Make: Hindware Cat No. 91088 or equivalent in makes mentioned in Appendix "B" here-in-after.
76S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, including lime concrete bedding and making good disturbed floor, complete all as specified and as directed.
77S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., complete all as specified & as directed.
78S&F in repairs wall mounted vitreous China ware wash down water closet (EWC) of size 50.5 x 36.5 x 36 cm, star white, one piece with soft PP seat cover and twin flush fittings complete all as directed. Make: Hindware Cat No. 92559 or equivalent in makes mentioned in Appendix "B" here-in-after.
79S&F in repairs vitreous china urinal, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including CP brass spreader, PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified and as directed.
80S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed.
81S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device complete all as directed.
82S&F sink without draining board, glossy finished, made out of 1.00 mm thick stainless steel sheet for kitchen or laboratory with plug, washers and waste pipe, including bedding in CM to dwarf wall or including fixing cantilever, brackets and connecting union to pipe, overall size 495x420 mm with bowl size 410x330x160 mmincluding 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete all as specified and as directed including taking down old unserviceable sink with fittings.
83S&F sink with drainage board, glossy finished, made of stainless steel 1mm thick for Kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to brick wall, connecting union to pipe, overall minimum size 915mm x 460 mm with bowl size 410mm x 330mm x160 mm including 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete all as specified and as directed including taking down old unserviceable sink with fittings.
84Dismantling of existing any type & any capacity water storage tank fixed in any description andS&F new 1000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical verticalwith close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
85Dismantling of existing any type & any capacity water storage tank fixed in any description andS&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical verticalwith close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
86M&L for complete water proofing treatment to sunken floors and returning filling of sunken and repair as under :- (i) First layer of slurry of cement using 0.225 Kg Cebex 100 or equivalent mixed to 50 kg bag of cement using pressure grouting with 40 psi pump after filling all joints/ cracks in CM 1:4 mixed with Nitobond SBR or equivalent @ 1 Litre per 50 kg bag of cement. (ii) Providing and applying 1.5mm thick with two coats with interval period of 6 hrs over substrate at a coverage rate 2 kg per sqm using spray/ roller over a layer of water proof coating using Fosroc Nitoproof 600 or equivalent over dry surfaces. (iii) Laying 200gms non woven geo textile membrane over Nitoproof 600 coating with overlap sealed before providing screed bedding. Note : Quoted rate shall be inclusive of demolition of existing sunken treatment.
87S&F 50mm bore and 60 cm long GI pipe medium grade fixed in floors as spouts for sunken floor including cutting and making holes in stone masonry walls and making good in PCC 1:2:4 type B0 and CM 1:3 complete all as directed. Note : Free end of spout shall be cut at 45 degree angle.
88M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement over face of concrete of column/ beams/ tanks 20 to 30mm thick in two layers surfaces applied as per manufacturer’s instructions complete all as directed by the Engineer-in-Charge. Note:- SBR latex chemical shall be measured and paid for separately as ‘Supply only’. (ii) Cost of scaffolding shall be deemed inclusive in quoted rates.
89Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.