Tender For Addn/Altn/Improvement To Classroom And Provn Of Smoke Detector At Dit At Subroto Park Under Ge (Af) Subroto Park, Delhi Cantt-10, New Delhi-Delhi

Military Engineer Services-MES has published Tender For Addn/Altn/Improvement To Classroom And Provn Of Smoke Detector At Dit At Subroto Park Under Ge (Af) Subroto Park, Delhi Cantt-10. Submission Date for this Tender is 21-07-2023. Smoke Detectors Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38077255
Corrigendum : Tender For Addn/Altn/Improvement To Classroom And Provn Of Smoke Detector At Dit At Subroto Park Under Ge (Af) Subroto Park, Delhi Cantt-10
Open Tender
Indian
Delhi
New Delhi
21-07-2023

Tender Details

Addn/Altn/Improvement To Classroom And Provn Of Smoke Detector At Dit At Subroto Park Under Ge (Af) Subroto Park, Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Jun-2023 CORRIGENDUM 01 Date 14-07-2023
2 14-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-07-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 179000.0 /-
Tender Value
INR 1.03 Crore /-

BOQ Items

Name of Work: ADDN/ALTN/IMPROVEMENT TO CLASSROOM AND PROVN OF SMOKE DETECTOR AT DIT AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
Sl. No. Item Description
1BUILDING WORKS
2Dismantling floor, hearth , or wall tiling including cement mortar bedding ( but not backing)and rubbish off the premisescomplete all as specified and directed.
3Dismantling of Cement concrete tiles/paver block including cement mortar bedding ( but not backing )and rubbish off the premisescomplete all as specified and directed.
4Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed
5Dismantling boarding , any description, fixed in anyposition with nails/screws complete all as specified and as directed
6Taking downframes or Chowkhats with shutters (without taking off shutters from the frames) of any descriptionexc. 1.50 Sqmnotexc. 4.0 Sqmeach including necessary repair to opening with CM 1:4 complete all as specified and as directed.
7Dismantling of aluminium door, partition, window & ventilator including all necessary fittings complete all as specified and as directed
8Dismantling of corrugated steel sheeting, any gauge, thickness, including nainital or similar roof coverings complete all as specified and as directed.
9Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water, etc. complete all as specified andas directed.
10S&F fabricating coloured powder coated aluminium frame work,door shutter ,windows , ventilators, partitions with one or more rebates sections of approved tint as required for partitions including beading,cleat, screws,fasteners, plugs, for fixing with wall/ceiling, columns/beams, etc.(minimum thickness of powder coating 50 micron)complete all as specified and directed.
11S&F aluminium coloured powder coated door shutters, aluminium section weighing min 0.55 Kg/m including necessaryjoining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, pad lock, hinges, anodised aluminium snap beading screws, etc.(minimum thickness of powder coating 50 micron)complete all as specified and directed.
12S&F 12mm thick particle board prelaminated on both sides with decorative choice laminations as in panel of door shutters partition wall, work stations including beading etc.complete all as specified and directed.
13S&F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed completeall as directed and specified.
14S&F for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed.
15S&F brass body Mortice lock, vertical type,size 100 mm 4 levers, including escutcheon plates and two No. keys and fixed complete all as specified and directed.
16S&F 5.5 mm thick plain or tinted glass, ordinary quality including rubber gasket for packing and fixed to aluminium doors/window/partition including necessary cutting / moulding and chamfering of edges for service window/counters complete all as specified and directed
17M&L brick work in CM ( 1:6 ) with using sub class `B ` modular brick straight or curved on plan exceeding 6.0 mtr mean radius complete all as specified anddirected.
18M&L for 15 mm thick cement plaster in cement mortar 1:6 on on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
19M&L for 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
20M&L for preparing surfaces of new plaster on walls and applying two coats of cement base paint over a coat of alkali resistantprimer complete all as specified and directed.
21M&L for Complete removal of existing treatment on walls and applying two coat of approved shade of oil emulsion distemper over a coat of alkali resistantprimer with 2 mm thick elastomeric wall care putty on walls complete all as specified and directed.
22M&L for preparation of new plastered surfaces of walls and applying two coats of 1st quality oil emulsion distemper over a coat of primer including 3 mm thickwall care putty on walls complete all as specified and directed.
23M&L for scratch free vitrified ceramic tiles10 mm thick (square or rectangular) polished area of each tileexceeding 0.42 sqm but not exceeding 1.00 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified and as directed.
24All as per ser. item No. 23 above but as in skirting/ dado etc but with and including 10mm thick backing coat in cement mortar 1:4 on wall complete all as specified and as directed.
25Material and labour for POP false ceiling with ISI grade GI framing of cross section 1" X 1.5" cross, main 2" x 05" and angle 1" x 1" section with first quality chicken mesh of 0.71mm dia with size of mesh 20x20mm fixed with tinned tacks of wire staples including all hardware i.e. screws, hangers etc. with all hanging accessories cut out to made for lighting, fixture and AC grill etc. completed all as specified and directed.
26Providing and fixing factory made uPVC white colour casement (openable)Doormade of extrudedprofiles with wall thickness of 2.3 mm ( + 0.2 mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm),sash (60mm x 78mm),T profile (One vertical length in between two shutters) (60mmx74mm) Glazing bead(35mmx20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware EPDM gasket 1.2 + 0.2 mm thick galvanised steel frame (28mmx21.5mm) sash (31mmx27.5mm)"T" profile (27mmx17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners.Hardware : [ casementhandle made of zinc alloyed (white powder coated) Butt hinges of zinc alloyed (white powder coated) transmission gear made of mild steel with multi point locking system)and 5mm thick glazing with selected quality glass. Note : The unit rate quoted by contractor excludes cost of 5.5mm glassand includes all other connected accessories, cuttings, grooves etc.
27Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of"zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) -For area exc 2.00 sqm each
28M&L for framed work such as grill grating,etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars;barred iron doors; ladders ; framed balusters; walk ways; railing;framed work of water tanks and similar conforming to Fe-290 GdeE-165 complete all as specified and directed
29M&L for two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10 cm width or girth complete all as specified and directed
30M&L for Preparation of oldpainted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
31S&F vertical roller blinds made out of nylon cloth of any colour as approved including hanging arrangement rollers etc. complete as specified and directed .
32M&L for 75mm thick cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed .
33M& L for 60 mm thick, M-35 grade machine pressed precast colour concrete interlocking paver block in any shape and size as approved confirming to IS 15658-2006 (latest amended) with grey cement and pigment complete all as specified and directed.
34M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
35S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161:1979 grade St-240 complete all as specified and directed.
36S & F moulded pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
37S & F moulded pre-painted galvalume aluminium zinc coating GI based plainsteel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in eaves sheeting /cladding to wall, fixed with self tapping screws complete all as specified and directed.
38M&L for Non-skid coloured ceramic tiles, 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/wall etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over including 15 mm thick screed bead in CM 1:4,including dismantling of tiles complete all as specified and directed.
39M & L for Glazed ceramic coloured tiles of size 350x 250x 7mm/ 450X 350X 7 mm thick on vertical surfacesuch as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white or colour cement with pigment to match the shade of tilesand including 10 mm thick backing coat in CM (1:4) including dismantling of tiles complete all as specified and directed.
40Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre paintedGypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceanic cascade or Electra) as approved by GE all as per , Everest Ceiling grid system "Regular T-2430" or its equivalent make"" at any height complete all as specified and as directed.
41S & F rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 Grade E-165 including dismantling complete all as specified and directed.
42Cutting holes in brick wall built in cement mortar or dismantling existing PCC bed block n exc. Half brick thick for inserting hold fast and making good dismantled portion in cement mortar 1:3 complete all as specified and as directed.
43S&F in repairs 40 mm thick , 2nd class hardwood planks , planed one side with butt joints and fixed with nails complete all as specified and as directed..
44M&L Preparation of new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
45M & L for PVC Profile for wall panelling of colour/shade as approved, size 250 mm wide, 08 mm overall thick with 1 mm wall thickness fixed with screw to mild steel square (size 20 mm x 20 mm x 1 mm thick) tubular frame work including one coat of red oxide primer, fixed to walls and including dismantling complete all as specified and directed.
46M & L forPVC Profile corner beading L/T type for wall panelling , colour/shade matching with wall panelling complete all as specified and directed.
47FIRE ALARM SYSTEM
48Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent Addressable optical smoke detector having twin LED’s for 360 degree viewing angle & hard Addressable having rotary decade address which is from 01-99. LED on the detector shall blink each time the sensor is scanned by the FACP. If the FACP determines the sensor is in alarm, the FACP will command the sensor LED to remain on to indicate the same. Each Sensor will be capable of being tested for alarm via command from the FACP. Each sensor shall respond to FACPs can with the Information about its type for identification ,complete all as specified and directed.
49Supply, Installation, Testing & Commissioning of UL/EN Listed Fault Isolator Module. This unit shall be placed on the loop preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring. All the other detectors shall remain functional because of the Class A wiring of the loop. The isolator shall not utilize an address and shall be built into the detector base wherever required complete all as specified and directed.
50Supply, Installation, Testing & Commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting glass break type having Rotary Decade Switches for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standard sand Duly Approved by EN54 /LPCB /VDS /UL/ BSA complete all as specified and directed.
51Supply,Installation,Testing & Commissioning of Response Indicator for above false ceiling detectors & detectors installed inside cabins.Response indicators with all accessories shall be as per technical specificationcomplete all as specified and directed.
52Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent addressable Output module having facility to activate AHU,Lifts etc.having option of RAIL or Surface Mounting withTri Color LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99 complete as required as per specification complete all as specified and as directed.
53Supply,Installation,Testing & Commissioning of UL/EN ListedIntelligent addressable Input module for monitoring purpose having option of RAIL or Surface Mounting with Tri-Color LED status Indicator with Built in ShortCircuit Isolators having Visible Rotary Decade Address Switches from 01-99 dully approved to GEAGE1-082 conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed.
54Supply,Installation,Testing & Commissioning of UL/EN Listedloop powered Sounder Cum Strobe complete all as required as per specification duly Approved byEN54/LPCB/VDS/UL/BSA complete all as specified and directed . Note: No additional power supply and control module shall be required to trigger the sounder.
55Supply,Installation,Testing & Commissioning of UL/EN Listed Analog addressable Fire Alarm system,having the capacity of 99 devices & 99 detectors per loop.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 999 events. Further,the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered.The panel should have in built common Alarm,Fault and monitored sounder output. The panel shall have a alphanumeric LCD display and having minimum160 Characters in the display. A minimum of two on-board sounder circuits shall be provided.The sounder out puts shall be fully programmable, monitored and short-circuit protected.The panel shall have a built in power supply and battery charger, 24V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm condition and complete as required as per specification.The fire alarm panel should be network able upto 99 panel & repeater panel. A walk test option shall be provided for convenient testing of detectors and alarm initiating devices without continually having to reset the panel.The fire alarm panel shall be compatible for hardware / software integration of PA System.The panel shall provide a flexible way of performing complex cause-and-effect programming.The fire alarm control panel shall have the ability to automatically invoke different operating modes according to the time of day.The control panel shall be capable of expansion. Capacity of upto five analogue addressable detection loops,using five plug-in loop driver modules shall be available.The control panel shall support upto five analogue addressable loops with the capability to control 495 analogue sensors and 495 addressable modules giving the maximum capacity of 990 addresses in case of fiveloop panel. Each mode shall have adjustable start and finish times. 20number zonal fire indicators(LED’s) and 20 number zonal fault/test/disabled(LED’s) shall be provided.The fire alarm control panel shall have three user control levels. A dedicated RS232 port shall be available for both connections to a local printer and upload /download of configuration data via the manufacturer’s standard PC programming tool.
56Ser item no 55.00 contd... The FACP shall have the provision to integrate with two way fire fighter control system.The FACP shall be able to supervise individual detectors for proper performance as well as to give pin point location of Fire or Fault alarm and initiate alarms as well as facility for cutting off of AHU’s and Electrical Power is also to be included.The panel shall be compatible with IBMS system with MODBUS protocol. EN54/UL/LPCB approved. NOTE:(a) The supplied fire alarm panel shall have the feature of soft integration with the existing fire alarm system complete all as specified and directed .
57Supply and installation of Loop driver card complete all as specified and directed.
58Supply and installation of RS 485 Communication module complete all as specified and directed.
59Supply and installation of Modbus TCP/IP interface module, requires an RS485 card to be fitted in the control panel & MI-RJ-45 Cable complete all as specified and directed.
60Supply and installation of Internal Printer Module complete all as specified and directed
61Supplying, drawing, connecting, testing & commissioning of 2 core, 1.5 sq. mm. stranded copper conductor, PVC insulated PVC sheathed,aluminium mylar tape shielded FRLS wire in draw through existing conduit complete all as specified and directed.
62Supply and laying of 25/20 mm Dia PVC conduits fixing on wall/roof/ceiling etc including concealed in wall and securing with proper saddle and making good disturbed surface and well finishing (For Fire Detection)with all accessories complete all as specified and directed.
63M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated un sheathed multi stranded copper conductor,FRLS 1100 Volts grade, with non metalic rigid PVC medium grade duty conduit/casing capping on wall/roof for surfacing wiring but not less than 20mm dia with accessories such as junction boxes, bends, tees etc. of suitable sizeincluding sunk cast iron or pressed steel terminal box for mounting switches, sockets fan regulators etc with 3 mm thick plastic laminated sheet top cover including continuous earth wire PVC insulated 1.50 Sq mm multi stranded copperconductor, FRLS 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed for the following :-
64(a) One three pin switch socket 5 Amps plug point on independent board
65S&F of socket outlet 2 in 1, 3 pin 5 Amps flush type suitable for 240V AC complete all as specified and directed.
66S&F in repairs MCB single pole and neutral32 amps working on 240 volts 50 Hz AC supply,10 KA "C" seriesincluding taking out old one complete all as specified and directed.. Make : Havells/L&T/C&S/Legrand
67Supply and fixing of fire alarm sounder/sirens Electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 DB TO 120 DB measured at 1.5 Mtr with sound output variation of +5DBfor 1000 mtr range complete with fire alarm system all as specified and directed
68FIRE HYDRANT SYSTEM
69Supply,installation,testing&commissioningof single headed, S.S.ISI marked oblique pattern hydrant landing valvewith100mmdiaflanged inletand63mmdia instantaneoustypefemale outlet complete with ABS cap and G.I. chain, twist release type plug and all accessories as per IS:5290-1983 (Type "A") complete all as specified and directed.
70Supply, fixing, testing & commissioning of Wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia with gun metal (GM) shut off nozzle having 6.5 mm dia orifice. The hose reel shall be conforming to IS: 884-1985. Rate shall include 25 mm dia M.S. pipe (heavy class) connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall by means of 120 mm x 100 mm long fasteners, bolts and nuts including painting complete all as specified and directed.
71Supply,installation,testing&commissioningin proper positionflexiblehose(RRL)ISImarked(IS:636)63 mmdiax 15mlongcompletewithinstantaneoustype S.S.63mmdia, maleandfemalecouplings(IS:903) boundandriveted to hose pipe complete all as specified and directed.
72Supply,installation,testing&commissioning of proper position S.S. 63mm diashort sizebranch pipeswith 20mmdianozzleswith63 mm instantaneouscoupling complete (IS:903) complete all as specified and directed.
73Supply, fixing, testing & commissioning of Hose cabinets for yard/internal hydrant fabricated from 18 gauge MS sheet with full double 4 mm glass door ,frame and locking arrangement, suitable to accommodate,2nos.15mlonghose,1 No branch pipe. The cabinet shall be painted with one coatofprimerand finished stove enameled "Fire Red", "Fire Hose"writtenon frontincludingsuitably mounted as required complete all as specified and directed. (Approx 0.80 m X 0.60 m X0.25 m).
74Supply and fixing Stainless Steel (SS 304 grade) four way fire brigade inlet connection (suction collecting head) to external fire hydrant ring/hydrant header/ riser with 4 Nos. 63 mm dia instantaneous type mail coupling/inlet and 150 mm dia flanges outlet conforming to IS:904 with blank cap and chain including 150 mm dia butterfly valve (PN 1.6 rating) and wafer type non-return valve complete with nuts, bolts, flanges and complete in all respect. Quoted rate shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) ofadequate size (approx 0.8 m x 0.6 m x 0.45 m) to house the above mentioned component duly painted with one coat of primer and two or more coats of stove enamel paint of approved make and shead and suitably mounted on raised masonry platform as required complete all as specified and directed. [Location Outside the Building for External Fire Ring, Internal Fire Hydrant System & Sprinkler System].
75Supply, fixing, testing and commissioning of heavy duty class "C" MS pipe conforming to, IS : 1239 (Part-1) marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. for following sizes. Standard MS fitting with welded joints or screwed joints as required including fixing the pipe with necessary structural supports including painting of two coats of synthetic enamel paint over two coats of red oxide primer including all civil breakage’s and making good the same including cutting holes and chases in brick, RCC work.All hangers, clamps brackets etc shall be of galvanized Iron unless specified other wise and then supply of the same shall be included for the rates under this head.Welding of any kind on the galvanized support / hanger shall not be permitted including synthetic enamel paint of approved make over a coat of zinc primer.
76(a) 150 mm dia
77(b) 100 mm dia
78Supply, fixing, testing & commissioning ofC.I. Wafer Type dual plate non-return valve [PN 1.6 Rating (16kg/cm2] with SS 316 Grade disc, EPDM Seating and test pressure not less than 25 kg/cm2, complete2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes.
79(a) 150mm dia
80(b) 100mm dia
81Supply, fixing,testing and commissioning cast iron butterfly valves (Conforming to I.S:13095) of PN 16 rating with SS 316 grade disc complete with bolts, of following sizes, nuts, 3mmthickcompressed asbestosgasket, companion flanges as per table "E" complete in all respects, including provision for locking with pad lock arrangement and supply and fixing of seven lever pad lock with universal key complete all as specified and directed.
82(a) 150 mm dia
83(b) 100 mm dia
84Supply, fixing, testing & commissioning of flanged end basket strainer made from MS body with bottom and top removable flanges with nuts, bolts etc havingfiltration area at least 6 times the cross sectional area of the pipe - For 150 mm Dia.
85Supply, fixing, testing & commissioning of flanged end basket strainer made from MS body with bottom and top removable flanges with nuts, bolts etc havingfiltration area at least 6 times the cross sectional area of the pipe- For 100 mm Dia.
86Supply and applying one coat of 4 mm Thick"PYPKOTE" or COATEK anti rust pipe protection conforming to IS: 10221 by thermo fusion process including PYPKOTE @ 100gm/Sqm. The application shall be strictly as per manufactures specifications and overlap of 25 mm to make an impermeable layer on M.S. Pipes running underground /buried/in trenches complete including surface preparation including conducting holiday test. The application process shall be strictly according to manufacturer’s specification /recommendation.
87Excavating trenches of required width for pipe, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed
88M& L for Painting ofpipe with one coat of primer and two coats of syntheticenamelpaintofapprovedmakeand shade including all steel work complete all as specified and directed
89Material and labour for cutting of wall for insertion of fire fighting pipe/ for mounting Wall mounting swinging type first aid fire hose reel with drum, hanging bracket inside the building. quoted rate also includesmaking good of wall surface and matching with existing wall after insertion of pipe and mounting hose reel complete all as specified and directed.
90Material and labour for Connection with internal jointing complete with isolation valve and joining arrangement complete all as specified and directed
91REFRIGERATION & AIR-CONDITIONING
92Disconnecting from mains dismantling taking down and depositing of oldCassette AC-08 Nos, including connected accessories like refrigerant tubing stand electric cable etc and deposit to MES store yard complete, all as specified and directed.
93Labour for installationof indoor/outdoor unit of cassette type AC of any make & model from one location to another location and cutting wall/concrete including arrangement of required T&P, laying ofinsulated copper tubing, positioning of condensing unit , fixing ofPVC flexible multistranded copper conductor of size 4 sq mm with all electrical connection and brazing work, leak check, dehydration and topping up of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed
94Supply and fixing in replacement of Rigid PVC pipes size of 20 mm dia pressure rating 10 kgf/cm2 fixing on wall/ceiling by using same size of clamps and screwing on wall up to building by using ladder/crane or necessary tools and plants including necessary Tee, color, bend, socket etc complete all as specified and directed.
95Supply and install hi wall split units indoor/outdoor copper tube evaporator and copper condensor, R32 Gas and condensing unit capacity of 2 Ton complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum4 star rating and EER 4.5 CFC free, inverter type AC of capacity 2 Ton fitted on wall and outdoor to be fixing on roof/wall at required place including all necessary electrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc up to 3 mtr complete all as specified and directed.
96Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA
97S&F sheet metal single pole and neutral enclosures with two pin and earth plug and socket capacity 20-32 Amps complete with one SP MCB capacity 20-32 Amps complete, all as specified and directed.
98S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 4 Sqmm 3 core complete, all as specified and directed.
99S & F 3 core flexible copper cable of size 2.5 Sq mm 1100 V grade complete all as specified and as directed.
100S&F Low density polyethylene pipes (LDPE) 20 mm dia of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc. including accessories, clamps and fasteners complete all as specified and as directed.
101M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for installation of condensing unit on the wall / ground complete all as specified and as directed.
102Supply and laying of refrigerant line copper tubing of size 5/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed.
103Supply and laying of refrigerant line copper tubing of size 3/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and as directed.
104Supply and fixing of foam insulation for copper tubing of size 5/8" complete all as specified and as directed.
105Supply and fixing of foam insulation for copper tubing of size 3/8" complete all as specified and as directed.
106INTERNAL ELECTRIFICATION
107Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power) complete,such as switches, ceiling roses,pendents, regulators, sockets etc.removing materials to store for keeping in safe custodyor for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc.complete all as specified and directed
108M&L forpoint wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and accessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in flush metal box along with outer cover plate for mounting modular switch, socket and electronic regulator along with provision ofearth wire of PVC insulated, unsheathed,1100 V grade cable multi stranded FRLS ISI markedcopper conductor of size 1.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FRLS cable for continuous earth wire connected to gang box of required size for one light/fan/bell point controlled by one switch.
109(a) All as per item No-100 above but one light point controlled by one SP switch
110(b) All as per item No-100 above but one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
111(c ) All as per item No-100 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
112(d) All as per item No-100 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
113All as per item No 100 above but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FRLS cable for continuous earth wire required size complete all as specified and directed.
114S&F switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed.
115S&F switch piano, flush type single pole, one way, 15 Amps, 240 volts complete all as specified and directed.
116S&F socket outlet 5 pin 5 Amps complete all as specified and directed.
117S&F socket16 Amps, 2 in 1, flush type complete all as specified and directed.
118Fixing only LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
119Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
120Supply and fixingin replacement ceiling roses, surface bakelite 65x50mm ,3 terminals3 phase, PVC/Polycarbonate, isolated bodyall as specified and directed at site.
121Taking down carefully wall mounted fans of any size for minorrefixing in its original position including connecting up with flexible twin core cablefrom ceiling rose or connector to fan complete should be fix in position in all respect including refixing after making serviceable complete all as specified and directed.
122M & L for in replacement submain wiring with four run of singlecore 10 sqmm PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 10 sqmm PVC insulated butunsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittingsall laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuityconductorof similar type cable complete all as specified and directed - 4 Runs of 10Sqmm singlecoreand one run of 10 sqmm single core cable.
123M & L for in replacement submain wiring with two run of 6.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 6.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittingsall laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuityconductorof similar type cable complete all as specified and directed- 2 Runs of 6.0Sqmm singlecoreand one run of 6.0 sqmm single core cable.
124M & L for in replacement submain wiring with two run of 4.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 4.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittingsall laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuityconductorof similar type cable complete all as specified - 2 Runs of 4.0Sqmm singlecoreand one run of 4.0 sqmm single core cable.(considered for AC point)
125Suppy & laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core and including PVC conduit size of suitable size according to cable including conduit fittings and accessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in flush metal box complete all as specified and as directed. .
126Supply and fixing vertical distribution boardmade out of CRCA sheet, double door, fixed flush in wall TPN 4 way 415 volts having 250 Amps rated bus bar and dust and vermin proof suitable for MCCB as incomer and MCBas outgoing complete all as specified and as directed by Engineer-in-Charge including cutting chases in walls for fixing DB and making good the disturbed wall surface to match with existing specification of make Havells cat part No DHDLVDRWAOFO04 or equivalentmake of Bajaj/Crompton etc all as specified and directed. Note :- MCCB/MCB shall be measured and paid separately.
127Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed.
128Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 4 way 240 volts double door type regal gray horizontal type,concealed in wall such that front cover shall be seen flush with the wall surface complete all as specified and as directed.Note :- MCB shall be measured and paid separately
129Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed. Note :- MCB shall be measured and paid separately
130Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN12 way 240 volts double door type regal gray horizontal type complete all as specified and as directed. Note :- MCB shall be measured and paid separately
131Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN16 way 240 volts double door type regal gray horizontal type complete all as specified and as directed.Note :- MCB shall be measured and paid separately
132S&F MCB SP 5 to 32 Amps 10 KA, 240 volt "C" Series complete all as specified and directed.Make: Havells/L&T/Legrand/C&S
133S&F MCB SPN 40 Amps 10 KA, 240 volt50 Hz "C" Series complete all as specified and directed.
134M& L for Earthing complete with galvanised steel earth plate electrode 60 × 60cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Notes :- (i) GI strip connecting upto test point is included in this item. (iii)GI pipe 40 mm dia protection pipe shall be provided upto test point.
135M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail