Airports Authority Of India has published Tender For Provision Of Boom Barriers Tyre Killers And Hydraulic Bollards At Various Locations At Jabalpur Airport Jabalpur Madhya Pradesh. Submission Date for this Tender is 29-06-2023. Gate Barrier Systems Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Jun-2023 | Corrigendum no 01 | Other | 29-06-2023 |
Sl. No. | Item Description |
1 | Supply,Installation,TestingandCommissioningof “Crash Rated Electro- Hydraulic BollardSystems”as per DOS/ ASTM/PAS68 /IWA 14:2013standards with minimumK4crashrating(Individual bollard should bephysically crash tested fromreputedtesting agency) . Bollardsshouldbeofminimum900mmheightand275 mm diamade upof heavysteel cylindricalweldment.Thebollardsshouldhave anAxleloadbearingcapacityofRoad/Baseplateof minimum20 tons with a provisionof Operationalalertwith BlinkingLED,Audiosignal duringoperation along with all other accessories like provision of Manual operation during power off, Hydraulic Power Pack / Unit with accumulator, safety interlock detectorand ControlpanelhavingincomerMCCBofsuitablerating,control andlogiccircuitplacedinsideIP66weatherproofenclosure, withlockandkey arrangement. Theenclose shouldbe equipped withLED Light attheTop indicatingserviceability of electricsystems.Work includes all civil and electricalworkseach as excavationofexisting PQC/bitumen road, disposal of excavated material,fixingthe bollardssystems,concreteworkand makinggoodthesome after installationof bollards,provisionofSelfprimingsumppumpofsuitableratingtodrainthe accumulatedwater,supply&layingof cables insuitableHDPE/DWC/GIPipes (upto30 Meter)and interconnection,complete as perthetechnical specificationand as per directions and to the complete satisfaction of the Engineer-in-charge.(Costincludeseachandevery item mentionedabove.) A) No of Bollards in Combination- 06 Bollards |
2 | Supply,Installation,TestingandCommissioningof “Crash Rated Electro- Hydraulic BollardSystems”as per DOS/ ASTM/PAS68 /IWA 14:2013standards with minimumK4crashrating(Individual bollard should bephysically crash tested fromreputedtesting agency) . Bollardsshouldbeofminimum900mmheightand275 mm diamade upof heavysteel cylindricalweldment.Thebollardsshouldhave anAxleloadbearingcapacityofRoad/Baseplateof minimum20 tons with a provisionof Operationalalertwith BlinkingLED,Audiosignal duringoperation along with all other accessories like provision of Manual operation during power off, Hydraulic Power Pack / Unit with accumulator, safety interlock detectorand ControlpanelhavingincomerMCCBofsuitablerating,control andlogiccircuitplacedinsideIP66weatherproofenclosure, withlockandkey arrangement. Theenclose shouldbe equipped withLED Light attheTop indicatingserviceability of electricsystems.Work includes all civil and electricalworkseach as excavationofexisting PQC/bitumen road, disposal of excavated material,fixingthe bollardssystems,concreteworkand makinggoodthesome after installationof bollards,provisionofSelfprimingsumppumpofsuitableratingtodrainthe accumulatedwater,supply&layingof cables insuitableHDPE/DWC/GIPipes (upto30 Meter)and interconnection,complete as perthetechnical specificationand as per directions and to the complete satisfaction of the Engineer-in-charge.(Costincludeseachandevery item mentionedabove.} A) No of Bollards in Combination- 03 Bollards |
3 | Supply,Installation,TestingandCommissioningof“Crash Rated Electro-Hydraulictyre killer"ofblockingwidthofminimum3.0 meter .Thesystemshall consistofhydraulicautomaticspikebarriermadeofgalvanizedsteel .Thespikeshouldbeofanominaldiaof25mm,withspacingbetween spikes notmorethen200mmatanangleof 60, suitabletowork on 230V/415V, 50Hz AC supplyalong with all otheraccessories like provision ofManualOperation duringpoweroff, Hydraulic PowerPack / Unit with accumulator, safety interlock detector and Control panel having incomer MCCBofsuitable rating,control andlogiccircuitplacedinsideIP66weather proof enclosure, with lock and key arrangement. The enclose shouldbe equipped with LED Light at the Tope indicating serviceability of electric systems. Workincludesallcivilandelectricalworkssuchasexcavationof existingPQC / bitumenroad, disposal of excavated material,fixingtheSpikesystems,concreteworkand makinggoodthesameafterinstallation ofSpikearrestor,provisionofSelf primingsump pumpofsuitableratingto draintheaccumulatedwater,supply & laying ofcables in suitableHDPE/ DWC/ GI Pipes (upto 30Meter) and interconnection, completeas per the technicalspecificationand as per directions and to the complete satisfaction of the Engineer-in-charge.(Cost includeseach and every item mentionedabove). |
4 | Supply,Installation,TestingandCommissioningof“Crash Rated Electro-Hydraulictyre killer"ofblockingwidthofminimum7.0 meter .Thesystemshall consistofhydraulicautomaticspikebarriermadeofgalvanizedsteel .Thespikeshouldbeofanominaldiaof25mm,withspacingbetween spikes notmorethen200mmatanangleof 60, suitabletowork on 230V/415V, 50Hz AC supplyalong with all otheraccessories like provision ofManualOperation duringpoweroff, Hydraulic PowerPack / Unit with accumulator, safety interlock detector and Control panel having incomer MCCBofsuitable rating,control andlogiccircuitplacedinsideIP66weather proof enclosure, with lock and key arrangement. The enclose shouldbe equipped with LED Light at the Tope indicating serviceability of electric systems. Workincludesallcivilandelectricalworkssuchasexcavationof existingPQC / bitumenroad, disposal of excavated material, fixingtheSpikesystems,concreteworkand makinggoodthesameafterinstallation ofSpikearrestor,provisionofSelf primingsump pumpofsuitableratingto draintheaccumulatedwater,supply & laying ofcables in suitableHDPE/ DWC/ GI Pipes (upto 30Meter) and interconnection, completeas per the technicalspecificationand as per directions and to the complete satisfaction of the Engineer-in-charge.(Cost includeseach and every item mentionedabove). |
5 | Supplying, installing,testing and commissioning, Automated Metal Boom Barrier of approved make and quality including barrier aluminium bar 4000 mm longwith mobile support, 24V DC motor with control unit in box, double built in LED flashing light, double spring to counter balance movement, entire body of unit and all aluminium work finished in UV resistant epoxy powder coating in approved shade, all accessories such as gears and levers, encoder for obstacle detection, manual lock release feature by key, three station push button, pair of photocells with anodised aluminium vertical mounting, built in control panel & motor, key operated lever release system with a cover plate, rubber end plug for aluminium bar, barrier cabinet, barrier mounting base etc. Work include all the necessary minor civil work if required.Supply & laying ofcables of suitable ratingin suitableHDPE/ DWC/ GI Pipes (upto 30Meter) and interconnection complete as per site requirement , technical specifications and as per directions and to the complete satisfaction of the Engineer-in-charge. |
6 | Supply and fixing of 4 ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 Amp tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s and MCCB as incomer (but without MCB"s and MCCB as incomer) as required. |
7 | Supply of 3.5 core ,50 sq.mm of XPLE insulated PVC sheathed ,aluminium conductor armoured power cable of 1.1 KV grade conforming to IS: 7098 (Part -I),1988 ammended upto date |
8 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp 16 KA 4P MCCB |
9 | Supplying and fixing 6 amps to 32 amps rating, 240volts, 10 kA, “C” curve, single pole miniature circuit breaker suitable for inductive loadin the existing MCB DB complete with connections, testing and commissioning etc. as required. |
10 | Supplying and fixing32 amps rating, 415volts, 10 kA, “C” curve, 3 Pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
11 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
12 | Supplying & laying of PE80, PN6, 63 mm dia HDPE pipe ISI markedas per IS: 4984/2016 with latest amendment up to date along with all necessary accessories likecoupler and other required accessories etc. direct in ground (750mm below ground level) including excavation and refilling the trenchcomplete as required. |
13 | Layingof one numberPVC insulatedand PVCsheathed/XLPE power cable of 1 . 1KVgradeoffollowingsizein existing Hume pipe/HDPE Pipe/GI Pipeetcas required. Above 35 sq. mm and upto 95 Sq mm. |
14 | LayingandfixingofonenumberPVC insulated andPVC sheathed / XLPE power cable of1.1KV grade of followingsize on wallsurface/recess/existing cable trayasrequired. Above 35 sq. mm and upto 95 Sq mm. |
15 | Supplying andmaking endtermination withbrasscompression gland and aluminiumlugs forfollowingsizeofPVC insulatedandPVCsheathed/XLPE aluminiumconductorcableof1.1 KV grade as required. 3.5 X50 sq. mm . |
16 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X50 sq. mm . |
17 | Supply ,Installation,testing & commissioning of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3mtr longh 50mm dia of outer shell (MS) with the 25mm dia inner shell (MS) of 80-100 microns galvanized earth electrode filled with highly conducting metallic compounds with the permanent sealing at both the ends with the lead terminal of 32X10mm size at the top along with 50 Kgs of Chemical mixture of Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound shall be less than 20%. The Chemical compound should be tested and certified by any International accredited or BIS( Bureau of Indian Standards) accredited laboratory. The earth electrode shall be dully tested & certifed by CPRI (Central Power Research Institute), Govt. of India. The chemical earth electrode manufacturers should be an ISO 9001:2008 & ISO 14001: 2004 certified organization. The Earth pit should be covered with heavy duty polyplastic weather proof chamber etc. as required & approved by the Engineer in Charge. |
18 | Providing andfixing25mmX 5mmG.I. striponsurface /recess/ existing HDPE Pipe/existing GI Pipefor connectionsetc.as required. |
19 | AllInclusiveComprehensive MaintenanceContractofeach 06 combination Crash Rated Electro- Hydraulic BollardSystems mentioned at BOQ ItemNo.1.00after completion of One year Defect Liability Period. |
20 | 1st year afterDLP. |
21 | 2nd year after DLP. |
22 | 3rd year after DLP. |
23 | 4th year after DLP. |
24 | 5th year after DLP. |
25 | AllInclusiveComprehensive MaintenanceContractofeach 03 combination Crash Rated Electro- Hydraulic BollardSystemsmentionedin BOQ ItemNo. 2.00 after completion of One year Defect Liability Period. |
26 | 1st year afterDLP. |
27 | 2nd year after DLP. |
28 | 3rd year after DLP. |
29 | 4th year after DLP. |
30 | 5th year after DLP. |
31 | AllInclusiveComprehensive MaintenanceContractofeach 3.0 meter Crash Rated Electro-Hydraulictyre killer mentionedin BOQ ItemNo.3.00after completion of One year Defect Liability Period. |
32 | 1st year afterDLP. |
33 | 2nd year after DLP. |
34 | 3rd year after DLP. |
35 | 4th year after DLP. |
36 | 5th year after DLP. |
37 | AllInclusiveComprehensive MaintenanceContractofeach7.0 meter Crash Rated Electro-Hydraulictyre killer mentionedin BOQ ItemNo. 4.00 after completion of One year Defect Liability Period. |
38 | 1st year afterDLP. |
39 | 2nd year after DLP. |
40 | 3rd year after DLP. |
41 | 4th year after DLP. |
42 | 5th year after DLP. |
43 | AllInclusiveComprehensive MaintenanceContractofeach4000 mm long Automatic Boom Barrier mentionedin BOQ ItemNo.5.00 after completion of One year Defect Liability Period. |
44 | 1st year afterDLP. |
45 | 2nd year after DLP. |
46 | 3rd year after DLP. |
47 | 4th year after DLP. |
48 | 5th year after DLP. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy