| 1 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 2 | 3½ X 300 sq. mm |
| 3 | 3½ X 150 sq. mm |
| 4 | 3½ X 50 sq. mm |
| 5 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 6 | 250 Amp, 35 KA,TPMCCB |
| 7 | 400 Amp, 35 KA,TPMCCB |
| 8 | Finding and detecting location of underground LT cable with FLC machine including excavation, pin poiniting , fault, refilling after repair of ground at marked fault as required at site. |
| 9 | Making provision of digging out the fault location upto 10 mtr for making straight through joint by tracing out the loop and then refilling the trench after restoration the electric supply etc. as required |
| 10 | Supplying, fixing and laying of one number PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning , protectivecovering, refilling the same etc. as required. |
| 11 | 3½ X 300 sq. mm |
| 12 | 3½ X 150 sq. mm |
| 13 | 3½ X 50 sq. mm |
| 14 | Servicing of VCB\"s with proper tools and testing equipments i/c racking out in tightening of bolts cleaning with petrol/ CRC/ CTC and dry cloths, calibration of protection relay etc. as required at site. |
| 15 | Servicing of 1000 KVA transformer with dry cloths and hand blower i/c inspection of fractures in insulation, tightening of cables, end termination nut bolts etc. as required at site. |
| 16 | Testing of existing transformer i/c no load testing , leakage, phase sequences etc. as required at site. |
| 17 | Making provision for dressing and laying the existing losing cable in trench & providing work suitable arrangement etc. as required. |
| 18 | Servicing of existing main LT panel comprising of ACBs and MCCBs indication dressing of cable tightening of cable, cleaning , testing etc. as required at site. |
| 19 | Servicing of existing capacitor panel comprising of MCCBs , indication dressing of cable tightening of cable , cleaning , testing etc as required at site. |
| 20 | Servicing of Air circuit breaker 800 amps 4 pole i/c cleaning of mechanical assembly with CRC/ prtrol, calibration of relays as required at site. |
| 21 | Supplying and fixing of digital volt meter (0-500V) and making connection etc. as required at site. |
| 22 | Supplying and fixing of digital amp meter (0-500A) and making conection etc. as required at site. |
| 23 | Supplying and fixing of 3 pole power contactor MNX 50 and making connection etc. as required at site. (Model No. CS97075) (LO&T) |
| 24 | Suplying and making of following power capacitor 440 volt cylindrical series LTCCH and making connection etc. as required at site. (L&T) |
| 25 | 10 KVR Capacitor |
| 26 | 25 KVR Capacitor |
| 27 | 50 KVR Capacitor |