|
| 1 | HT |
| 2 | Prov AAAC 7/3.15mm² Conductor (50mm²) {Includes Cutting and wastage} |
| 3 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 4 | Muffs with concerete filling |
| 5 | Prov.M.S C.I X-Arm (1500x100x50x6 mm),Long For Single Pole |
| 6 | Prov.M.S A.I X-Arm (1800x50x50x6 mm),Long For Single Pole |
| 7 | Prov M.S A.I X-Arm (50x50x6 mm), Length (2x750) mm Long For Single Pole |
| 8 | Prov M.S A.I X-Arm(50x50x6 mm), Length (2x600) mm Long For Single Pole |
| 9 | Prov .M.S C. I Cross Arm (100x50x6 mm), Length (2400) mm |
| 10 | Prov.M.S A.I (50x50x5 mm), Length (2700) mm |
| 11 | Prov.M.S C.I X-Arm (2400x75x40x6 mm),Long For G.O Switch &D.O.Fuses |
| 12 | Prov Belt Set - MS A I 50x50x6, Length [2400 mm x 2 No.] For Double Pole |
| 13 | Prov X-Bracing Set - MS A.I Iron 50x50x6,[2700 mm x 2 No.] For Double Pole |
| 14 | Discs insulator sets (comprising 1No.Disc(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 15 | Pin insulator |
| 16 | Stay Set Complete |
| 17 | Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set) |
| 18 | Full Clamp for stay |
| 19 | HT Earthing set complete (preferbly coil earthing) |
| 20 | Prov Double Continous Earth wire (GI, 8 SWG) @ 0.102 kg/m |
| 21 | ProvAluminium Paint |
| 22 | Prov Danger Plate (250X200X1.6 mm) |
| 23 | Prov Nuts and Bolts of Various Sizeswith flat and spring washers |
| 24 | Prov Barbed Wire |
| 25 | Prov GO AB Switch Unit (11kV, 400A, 25 KA ) |
| 26 | Prov D.O Fuse Unit |
| 27 | Erection charges as per cost data 2022-23 |
| 28 | ransportation charges as per cost data 2022-23 |
| 29 | 11/0.4 kV63 KVA, Distribution Sub-Station (2 Nos.) |
| 30 | Prov.Distribution Transformer (Ordinary) ,11/0.4 kV 63 KVA, |
| 31 | Prov.Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 32 | Prov.Muffs with concerete filling |
| 33 | Prov.X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line |
| 34 | Prov.MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA\"s |
| 35 | Prov.X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 36 | Transformer Bed, Belting & Knee Bracing |
| 37 | X-Arm:[Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos]forTransformer Bed |
| 38 | X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer] |
| 39 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 40 | MS Angle Iron (35X35x6 mm), Length : (460 ) x 2 Nos |
| 41 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 42 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 43 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 44 | MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 45 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm |
| 46 | GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 47 | D.O Fuse Unit |
| 48 | Surge Arrester, 9 kV Station Class(Porcelain Type) |
| 49 | Stay set complete |
| 50 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 51 | Pipe Earthing Set |
| 52 | LT Distribution Panel Box With MCCB(160A, 10KA,4P, 1No) & Kit-Kat 200Amp |
| 53 | Half Clamp (M.S. Flat 50X6 mm) |
| 54 | Full Clamps (M.S. Flat 50X6 mm) |
| 55 | Nuts and Bolts of Various Sizes(with flat and spring washers)] |
| 56 | Aluminium Thimble |
| 57 | Aluminium Thimble |
| 58 | Danger Plate |
| 59 | Barbed Wire |
| 60 | LT Cable (3.5 Core) 95 mm² |
| 61 | Aluminium Paint. |
| 62 | Prov.AAAC 7/3.15mm² Conductor for Earthing |
| 63 | Prov. plinth for double pole (100KVA S/Stn.) structure complete with digging, C.C. 1:6:12, R.R. masonary and plastering etc. size 10\"x3\"x2.5\" |
| 64 | 3-?, 4 wire CToperated Static Tri-Vector meter withBox(CT-100/5A) |
| 65 | Erection charges as per cost data 2022-23 |
| 66 | Transportation charges as per cost data 2022-23 |
| 67 | 3-Phase L.T line |
| 68 | AAAC 7/3.15 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} |
| 69 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) (with Ruling Span 67 m) |
| 70 | Muffs with concerete filling |
| 71 | Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr] |
| 72 | Shackle Insulator (16 kN) |
| 73 | D-Iron (U- Clamps) |
| 74 | Earth Knob |
| 75 | LT Stay Set |
| 76 | Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set) |
| 77 | Full Clamp |
| 78 | Earthing Set complete |
| 79 | Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m |
| 80 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 81 | Aluminium Paint |
| 82 | Erection charges as per cost data 2022-2023 |
| 83 | Transportation charges as per cost data 2022-23 |
| 84 | Quantities are mentioned above are tentative and Actual Quantity shall be worked out after Check Survey to be carried out by the successful Tender and detailed Engineering and finalization of Tower location Chart.Payment shall be made as per Approved Bill of Material/Actual Quantities measured at site. |