| Sl. No. | Item Description |
| 1 | Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm eachcomplete all as specified and directed. |
| 2 | Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each completeall as specified and directed.(Note for Item No. 1.00 & 2.00 - Rate shall be deemed to be include for cuttingholes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces). |
| 3 | Taking down chowkats with shutters any type (without taking off shutter from the frames)not exceeding 1.50 Sqm and refixing in same opening after easing and adjusting completeall as specified and directed. |
| 4 | Taking down ofshutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) as in ground floors or paving no exceeding 15cm thick below or above ground level complete all as specified and directed. |
| 6 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 7 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 9 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 10 | Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed. |
| 11 | Taking down cement plaster of any description on brick or stone or concrete surface of wall etc includingraking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 12 | Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed. |
| 13 | Dismantling of battens for tiles, shingles etc of any size including tilting fillet exceeding 15 cm complete all as specified and directed. |
| 14 | M&L for brick work with subclass \"B\" bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed. |
| 15 | M&L for brickwork with subclass \"B\" brickslocally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed. |
| 16 | Supply only integral water proofing compound liquid, ISI markedcomplete all as specified and directed. |
| 17 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 18 | Taking down old bituminous felt including PCC, screed bed (any thickness) and vegetation and disposed off to a distance not exceeding 50m and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc completeall as specified and directed. |
| 19 | M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cuttingchases for concealed water tubing etc and making good the disturbedsurface, cutting exceeding 10 cm but not exceeding 20cm girth complete all as specified and directed. |
| 20 | M&L for cutting holes into or through brick walls built in cement mortar or stone walls built in lime or cement mortar to a depth of embedded portion exceeding one brick but not exceeding two brick for inserting hold fast etc and making good dismantled portion with cement concrete (1:2:4) type B-1 complete all as specified and directed. |
| 21 | M&L forcement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in fixing hold fast, coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamferedon edges including necessary form work finishing the surface even and fair with using extra cementcomplete all as specified and directed. |
| 22 | M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) used as in shelves andlike etc complete all as specified and directed. |
| 23 | Providing formworkto the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and makingflat, rough finished surfaces of concrete complete all as specified and directed |
| 24 | M&L for cutting into existing manhole for connecting new drains, making good to pipeand rendering, cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required dia of pipe 150 mm complete all as specified and directed. |
| 25 | S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified anddirected. |
| 26 | S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 completeall as specified anddirected. |
| 27 | S&F of second class hard woodplain, solid, straight chowkats and frames, wrought, framed rebatedon the solid, rounded or chamfered put together with glue pinned at jointsetc complete all as specified and directed. |
| 28 | S&F of second class hard wood in fillets, square, rectangular or triangular in section, clean swan, fixed with nails or brads, sectional area exceeding 13 sqcm but not exceeding 25 Sqcmcomplete all as specified and directed. |
| 29 | S&F of 35 mm thick plain framed pannelled shutters (factory made) feather edged (any numbers of panels) with both sides or venneered particle board medium density wood particle board with commercial face venners supply and fitted to chowkat complete all as specified and directed. |
| 30 | S&F of 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made) for windows & doorsopen rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section-8, Clause 8.24 (b) (larger size to be provided) complete all as specified and directed. |
| 31 | S&F in repairs of 25mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc completeall as specified anddirected. |
| 32 | S&F of aluminium bracket (heavy duty), powder coatedof best quality as approvedsuitablefor fixing 25mm bore curtain rod fixed in wall complete all as specified and directed. |
| 33 | S&Ffor joist, channel, flat iron, angle or tee sections, fixed independently, with connecting base plates etc as in fencing post, struts, bend to shape, holes, drilled/notches cut out to received MS bolts and barbed wire embeded to concrete including tarring to steel work embdede to concreteof Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 34 | S&F in repairs of 20mm diagun metal gate valve with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed completeall as specified anddirected. |
| 35 | S&F in repairs of aluminium extuded body door closer hydraulicallyregulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg asfixedcomplete all as specified and directed. |
| 36 | S&F in repairs of continuous piano type hinges mild steel bright finish or electro galvanised, size of flap (when open) 30mm complete all as specified and directed. |
| 37 | S&F of 100 mm long cold rolled mild steel butt hinges, medium weight completeall as specified and directed. |
| 38 | S&F of 75 mm long cold rolled mild steel butt hinges, medium weight completeall as specified and directed. |
| 39 | S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed. |
| 40 | S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded sectionand fixed complete all as specified and directed. |
| 41 | S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded sectionand fixed complete all as specified and directed. |
| 42 | S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed. |
| 43 | S&Fin repairs of mortice lock, brass vertical type, size 100mm with 4 leavers complete all as specified and directed. |
| 44 | S&Fin repairs of mortice lock, brass vertical type, size 75mm with 4 leavers complete all as specified and directed. |
| 45 | S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple in window and door shutter completeall as specified anddirected. |
| 46 | S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 150mm) complete all as specified and directed. |
| 47 | S&F for 75 mm size extruded brass handle, fabricated type(as per IS-208 : 1996), polished complete all as specified and directed. |
| 48 | S&F in repair of 75 mm long aluminium anodised extruded alloy handle fabricated type(as per IS-208 : 1996)complete all as specified and directed. |
| 49 | S&F of 100 mm long aluminium anodisedhasp & staple safety type including hinge pin, bolt to hinge plate etc complete all as specified and directed. |
| 50 | S&F of Mild Steel hold fast or fan hook of flat iron 25mm x 6mmcomplete all as specified and directed. |
| 51 | S&F in repairs of double action floor spring hydraulically regulated made up ofminimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 52 | S&F of ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed completeall as specified and directed. |
| 53 | S&F for auto closing hydrolic hinges fixing with particle board with approved size and design complete all as specified and directed. |
| 54 | S&F of steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay,complete with glazing bars, dovetailed or welded to receivewire mesh/glass including taking down old unserviceable steel window complete all as specified and directed. |
| 55 | S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/orforged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0Gde-E-165 completeall as specified and directed. |
| 56 | S&F ofrolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality \"A\"complete all as specified and directed. |
| 57 | M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 58 | M&L for TMT bars6 to 8mmdia and over upto and including 10mm dia instirrups, spacers andbinders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 59 | S&F of anodised (powder coating of minimum thickness 50 micron) aluminium window/ventilators shutters, sliding/fixed type without sash bar, aluminum section weighing0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing,hinges type B-21100 mm long (02 Nos), peg stay 150mm long (01 No), anodised aluminium snap beading, screws etcincluding locking arrangement, roller completeall as specified and directed. |
| 60 | S&F of anodised (powder coating of minimum thickness 50 micron) aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including locking arrangement, roller after completeall as specified and directed. |
| 61 | S&F of anodised aluminium frame of doors, windows, ventilators with one or more rebates including joining cleat for fixing for completeall as specified and directed. |
| 62 | S&F of steel ventilators with top hung shutters includinghinges, steel peg stay including taking down old unserviceable steel ventilators complete all as specified and directed. |
| 63 | S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm,an asbestos Free fibre cement board manufacture using high Pressure System Curing technology.T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip,also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc.The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c.The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B.S- 476 part 4,5,6,7 & 8 should be placed in Grid module to formcomplete all as specified and directed. |
| 64 | S & F for 605mm X 605mm grid GI frame work for seamless false ceiling compising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm eachn and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including 12mm Gyspsum Board in ceiling fixed with screw as per manufacturers instructions for insulation/acoustic purpose of 600mm x 600mm in size fixed with snap grid flase ceiling frame and 0.55mm thickness having jurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with conccecting clips across the intermediate channel at 457mm centre to centre and Hangers 6mm dia GI (upto 1200mm length) adusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed. |
| 65 | M&L for PVC profile for wall panelling colouras approved size 250mm wide, 8mm over all thickness fixed with screw to mild steel square (size 20mmX20mmX1mm thick) tubular frame work including one coat of red oxide primer fixed to wall complete all as specified and directed. |
| 66 | M&L for PVC profile corner beading L/T type for wall panelling, colour matching with wall panelling complete all as specified and directed. |
| 67 | S&F of 6mm thickasbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with \"L\" or \"J\" type hooks including taking down old unserviceable AC sheet complete all as specified and directed. |
| 68 | M&L forcutting out cracks to V-Section existing roofs or terracingcleaning out, wetting, grouting with cement & sand slurry (1:3) complete all as specified and directed. |
| 69 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof coveringcomplete etc all as specified and directed. |
| 70 | S&F of pre-painted galvalume aluminium zinc coatingGI basedcorrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 71 | S&F of pre-painted galvalume aluminium zinc coatingGI basedplain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed. |
| 72 | M&L for 12mm thick medium density fibre board, exterior grade, fixed with screws/beading to aluminium frame workcompleteall as specified anddirected. |
| 73 | M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membranemanufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membraneminimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyesternon wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LPgas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paintcomplete all as specified anddirected. |
| 74 | M&L for 18/19 mm thick prelaminated particle board, exteriorgrade, prelaminated both side with decorative choice lamination, fixed with screws to aluminum frame work for cupboardshutter including taking down old unserviceable one complete all as specified and directed. |
| 75 | M&L for 50 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 76 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, paving, floor, hard standing, sub base floor etcincluding finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 77 | M&L for 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed. |
| 78 | M&L for 25mm (avg) thickPCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate)as in sub base of floor complete all as specified and directed. |
| 79 | M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mmthick(square/rectangular) area of each tileexceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurryand pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes completeall as specified and directed. |
| 80 | M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished)over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeall as specified and directed. |
| 81 | M&L for 18-20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, windowcill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed. |
| 82 | M&L for joint free coloured vitritied ceramic tiles 8 to 10mm thick (square/rectangular) polished, light shade, area of each tile not exceeding .36 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) completeall as specified and directed. |
| 83 | M&L for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thickor equivalentset and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles as in skirting/dado/vertical wall over and including 10 mm thick cementplaster in cement mortar (1:3) complete all as specified and directed. |
| 84 | M&L for 60mm thick machine pressed precast concrete interlocking paver block (coloured and polished)any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying complete all as specified and directed. |
| 85 | M&L for pre-polished coloured chequeredcement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed. |
| 86 | M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade \"A\" complete all as specified and directed. |
| 87 | M&L for rendering 10mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed. |
| 88 | M&L for rendering 15 mm thick plastering in cement mortar (1:3) on concretesurfaces of sunken floor mixed withWPC @200ml/50 Kg of cementfinished the surfaces even and smooth without using extra cement complete all as specified and directed.(Note : WPC shall be measured and paid separately under relevant item) |
| 89 | M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed. |
| 90 | M&L for rendering 15 mm thick on other than fair face of brick worksor concretesurfaces of wallswith cement mortar (1:4) mixing with WPC @200ml/50 Kg of cement,finished the surfaces even and smoothwithout using extra cement complete all as specified anddirected. (Note : WPC shall be measured and paid separately) |
| 91 | M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etcsurfacefinished even and smoothwithout using extra cementcomplete all as specified and directed. |
| 92 | M&L for 20 mm thick screed bed in cement mortar (1:4) on concrete surfaces of roof as levelling course mixing with WPC @200ml/50 Kg of cement,finished the surfaces even and smoothwithout using extra cement complete all as specified anddirected. (Note : WPC shall be measured and paid separately) |
| 93 | M&L forapplying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after preparation of new wooden surfaces of any descriptionover 10 cm girth or width complete all as specified and directed. |
| 94 | M&L forapplying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after complete removal of existing paint and preparation of old wooden surfaces of any descriptionover 10 cm girth or width complete all as specified and directed. |
| 95 | M&L for preparing surfaces ofsteel and iron work, new or old treating small articles such as strip, covers, gully gratings, hold fast ends of post, beads of chowkatsetc area tarred not exceeding 0.1 sqm and treated with tar or coal tar black paint complete all as specified and directed. |
| 96 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty newly plastered surfaces of wall after and including preparation of surfaces complete all as specified and directed. |
| 97 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty old decorated plaster surfaces of wall after and including complete removal of existing treatment andpreparation of surfaces complete all as specified and directed. |
| 98 | M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty newly plastered surfaces of ceiling after and includingpreparation of surfaces complete all as specified and directed. |
| 99 | M&L for applying two coats of synthetic enamel paint (1st grade quality) overa coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth completeall as specified and directed. |
| 100 | M&L for applying two coats of synthetic enamel paint (1st grade quality) overa coat of red oxide primer after complete removal of existing paint and preparation of old steel surfaces of any description over 10cm width or girth completeall as specified and directed. |
| 101 | M&L for complete removal of existing wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. |
| 102 | M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation ofexisting surfaces completeall as specified anddirected. |
| 103 | M&L for writing stops, commas, short lines dashes, hyphens, bracket etc after cleaning the existing surface complete all as specified and directed. |
| 104 | S&F of 5.5mm thick sheet glass ordinaryquality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane completeall as specified anddirected. |
| 105 | S&F of 5.5mm thick sheet glass ordinaryquality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm each pane completeall as specified anddirected. |
| 106 | S&F of 3.0mm thick sheet glass ordinaryquality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each paneincluding hacking out old broken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads completeall as specified anddirected. |
| 107 | S&F of 3mm thickfiguredglass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane fixed with putty or beads completeall as specified anddirected. |
| 108 | S&F in repairs of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw typefixed completeall as specified anddirected. |
| 109 | S&F in repairs of shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms)completeall as specified and directed. |
| 110 | S&F in repairsof 15 mm borestop valve/angular stop valve,fancy type, chromium plated ,cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unionscomplete all as specified and directed. |
| 111 | S&Fin repairs of 15 mm borestop valve,fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unionscompleteall as specified and directed. |
| 112 | S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges completeall as specified anddirected. |
| 113 | S&F in repairs of75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cementcomplete all as specified and directed. |
| 114 | S&F in repairs of vitreous china wash basin, white, flat back, size 630 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand completeall as specified and directed. |
| 115 | S&F in repairs of 15mm dia pillar tap, cast copper alloy with capstan heads, chromium plated,screweddown high pressure, with letter \"HOT\" or \"COLD\" with long screwed shanks & fly nuts, screwed for iron pipes completeall as specified anddirected. |
| 116 | S&F in repairs of 125mm dia grating with waste hole , fancy type, chromium plated complete all as specified and directed. |
| 117 | S&F in repairsof 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed completeall as specified anddirected |
| 118 | S&F in repairs ofsinks made of stainless steel 1mm thick kitchenor laboratory with plugs, washers andwastes;including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowlsize410mmx330mmx 160mmcompleteall as specified and directed. |
| 119 | S&F in repairs ofhealth faucet fixed to EWC with 1mtr long easy flexible tube of 8mm dia and wall hook complete all as specified and directed. |
| 120 | S&F in repairs of 600mm x 450 mm bevelled edge mirror of selected qualityglass, mounted on 6mm thick AC building board on commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscompleteall as specified anddirected. |
| 121 | S&Fin repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed. |
| 122 | S&F in repairs of vitreous china squatting pan \"Orissa\" pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floorcompleteall as specified and directed. |
| 123 | S&Fin repairs of vitreous china wash down water closet pan (pedestal pattern) white with \"P\" or \"S\" trap type(excluding flushing cistern & flush pipe)including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipeout inwith and including white seat cover etc. including making good to floor complete all as specified anddirected. |
| 124 | Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar (1:6) complete all as specified and directed. |
| 125 | S&F in repairs of 15 mmdiaPVC connectionpipe of length 450 mm with 02 Nos brass check nuts complete all as specified anddirected. |
| 126 | S&F of 32 mm bore low density polyethylenepipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc.complete including taking down old unserviceable pipe all as specified and directed. |
| 127 | S&F of500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer)ISI Marked hoisted and fixed in position withcover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with andincluding 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms)including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-Iand directed. |
| 128 | S&F of1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer)ISI Marked hoisted and fixed in position withcover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with andincluding 25mm dia ball valve high pressure of PTMT (minimum weight 455 gms)including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-Iand directed. |
| 129 | Disconnecting existing water tanks of (exceeding 500 & not exceeding 1000 litres in capacity), setting aside (or lowering if required)and cleaning, removing all scale and dirt etc from tanks and mouth of pipe including hoisting (if required) reconnecting and refixing in position with required fittings complete all as specified anddirected.(NOTE: Date of cleaning must be written at side of water tank with white paints after cleaning of tank) |
| 130 | S&F in repairs of 20mm dia ball brass valve, high pressure, with polythene float and fly nut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 131 | S&F of 15mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed. |
| 132 | Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trenchetc.) for any dia pipeswith new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed. |
| 133 | S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed. |
| 134 | S&F of 25mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed. |
| 135 | S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall orlaid in trenchesor in floor after and including dismantling of existing unserviceablepipe complete all as specified and directed. |
| 136 | S&Fof 110 mm bore PVC (SWR) bends any radiusprovided with access door completeall as specified and directed. |
| 137 | S&F of110mm bore PVC(SWR) junction single, (single T)equal or unequal providing access door completeall as specified and directed. |
| 138 | S&F of 110 mm bore PVC (SWR) branch piece, double (double Y) equal or unequalprovided with access door completeall as specified and directed. |
| 139 | S&Fof 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 140 | S&F of 110 mm bore PVC (SWR) vent cowl completeall as specified and directed. |
| 141 | S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall orlaid in trenchesor in floor after and including dismantling of existing unserviceablepipe complete all as specified and directed. |
| 142 | S&F of 75 mm bore PVC (SWR) branch piece, double (double Y) equal or unequalprovided with access door completeall as specified and directed. |
| 143 | S&Fof 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 144 | S&Fof 75 mm bore PVC (SWR) bends any radiusprovided with access door completeall as specified and directed. |
| 145 | S&F of75mm bore PVC(SWR) junction single, (single T)equal or unequal providing access door completeall as specified and directed. |
| 146 | S&F of 75 mm bore PVC (SWR) vent cowl completeall as specified and directed. |
| 147 | S&F PVC (SWR) in \"P\" trap complete all as specified and directed. |
| 148 | S&F PVC (SWR) in \"S\" trap complete all as specified and directed. |
| 149 | S&F in repair of wall mixer 3-in-1 system with provision for both hand shower and OH shower complete with 115mm long bend pipe, connecting legs & Wall Flange (without hand & over head shower) complete all as specified and directed. |
| 150 | S&F in repairs of 15mm bore wall mixer L-bend (provision of OH shower) fancy type chromium plated cast copper alloy completewith 115mm long bend pipe on upperside connecting legs and wall flange complete all as specified and directed |
| 151 | S&F in repairs of CP wash basin mixer for mixing hot & cold water screw down for iron pipe including necessary connection pipe from stop cock complete all as specified and directed |
| 152 | S&F of flexible tube 8mm dia and 1.5m long with nuts for hand shower fixed with wall mixer complete all as specified and directed. |
| 153 | S&F in repair of chromium plated towel ring of 200mm dia with round flange complete all as specified and directed. |
| 154 | S&F in repair of toilet paper holder fixed to walls with chromium plated (CP) brass screws all as specified and directed by Engr-in-Charge. |
| 155 | S&F in repairs of CP over head shower multi flow without arm of 125mm dia with flange joints including fixing to steel pipe or unionof 15mm diacomplete all as specified and directed. |
| 156 | S&F in repairs of CP round double rain shower without arm with flange, joints including fixing to steel pipe or union of 15mm diacomplete all as specified and directed. |
| 157 | S&F in repair of chromium plated Towel rack 600mm long with lower hangers complete all as specified and directed by Engr-in-Charge. |
| 158 | S&F in repairs of CP shower arm 20mm dia and 225mm long for wall mounted shower with flange joints including fixing to steel pipe or union of 15mm diacomplete all as specified and directed. |
| 159 | S&F in repairs of Corner glass shelf (large) 300 X 300mm (12\" x 12\") complete all as specified and directed. |
| 160 | S&F of stainless steel plate rack (0.63 mm thick s/s sheet) of size 775mmX900mmX250mm fixed in wall with stainless steel screw of suitable size completeall as specified and directed. |
| 161 | Providing water proofing treatment to RCC sunken slab as specified and directed as under:-(a) Demolished the existing damaged concrete from sunken portion carefully upto RCC slab including taking out of water closet and traps etc (depth approx 400mm)(b)Cleaning the existing RCC sunken slab and vertical wall/RCC beam as per direction.(c) 15mm thick plaster over the flat and vertical surface in CM (1:4) mixed with WPC as per manufacturer\"s instruction.(d) Applying two coats of elastomeric acrylic water proof coating using rooler, each coat of elastomeric actylic compound required 6-8 hrs to dry, second coat shall be applied on fetting the first coat complete dry consumption of materials shall be as per manufacturer\"s instruction.(e)Filling the sunken portion with PCC (1:5:10) type E2 with using 40mm graded stone aggregate.(f)After complete treatment of RCC sunken portion same shall be tested with 72 hrs ponding test, to observe the leakage and seepage from RCC portion. |
| 162 | Removing plant including roots by dismantling of brick work/PCC/RCC including necessary scaffolding any type in any location/position i.e. roof, parapet wall near pipes etc and applying concentrated hydrochloric or sulphuric acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC (1:2:4) type B0 & 10mm thick plaster in cement mortar (1:3) size of disturbed portion 150mm X150mmX200mm complete all as specified and directed. |