Tender For Repair And Maint Of Vrf-Iii Based Ac Plant Located In (Ntc Block 3 And 4) At Defence Lab Jodhpur, jodhpur-Rajasthan

Defence Research And Development Organisation -DRADO has published Tender For Repair And Maint Of Vrf-Iii Based Ac Plant Located In (Ntc Block 3 And 4) At Defence Lab Jodhpur. Submission Date for this Tender is 30-06-2023. HVAC Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38058441
Corrigendum : Tender For Repair And Maint Of Vrf-Iii Based Ac Plant Located In (Ntc Block 3 And 4) At Defence Lab Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
30-06-2023

Tender Details

Repair And Maint Of Vrf-Iii Based Ac Plant Located In (Ntc Block 3 And 4) At Defence Lab Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
INR 9.50 Lakhs /-

BOQ Items

Name of Work : REPAIR AND MAINT OF VRF-III BASED AC PLANT LOCATED IN (NTC BLOCK 3 & 4) AT DEFENCE LAB JODHPUR
Sl. No. Item Description
1Comprensive daily Maintenance, checking, testing, ON/OFF of Variable refrigerant flow modular type air conditioningsystem with stepless modulation complete withindoor and outdoor unit individual remote complete centralised controller inter connected refergerant piping checking of pipe lines for gas laeakage oil controlcable for the following equipments and accessories:-(A) Outdoor Units:- Outdoor units consists of compressor, heat exchanger, condenser fan, auto check function for error, Auto address setting microprocessor panel, isolating valves for the following capacity.Heat pump type (Cooling and Heating) of 10 Hp - 04 NosCooling and Heating type 12 Hp - 09 Nos Cooling and Heating type 14 Hp - 02 Nos Cooling and Heating type 16 Hp - 01 Nos Cooling and Heating type 18 Hp - 04 Nos (Total 20 Main units and 04 slave unit =24 Outdoor units) (B) Indoor units:- Indoor unit addresssetting multispeed motor oil section with DX coil outer consist drain pipe water lift mechanism its insulation pipe connection fresh air intake sysem with the following capacities.Ceiling mounted Cassette type 2.6 TR - 09 NosCeiling mounted Cassette type 3.3 TR - 07 Nos Split high wall mounted type of different capacity - 138 Nos (Total 154 indoor units)
2M&L for servicing of Daikin VRF-III including (outdoor and indoor) at the existing location with suitable electronic machine, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower,rewinding, assembling, testing and commissioning etc complete all as specified and directed by Engr-in-charge.
3Supply and charging of gas R- 410A inside the compressor and testing Complete all as specified and as directed by Engr-in-Charge.
4S&F in replacement Remotecontroller for indoor unit as per sample Complete all as specified and as directed by Engr-in-Charge.
5S&F in replacement Battery Cell 1.5 Volt, Complete all as specified and as directed by Engr-in-Charge.
6S&F in repair of Printed Circuit Board for indoor unitof any capacity available at site complete all as specified and as directed by Engr-in-Charge.
7S&F in replacement of Printed Circuit Board for indoor unitof any capacity available at site complete all as specified and as directed by Engr-in-Charge.
8S&F in replacement of Adopter for fixing of Printed Circuit Board in indoor unitof any capacity available at site complete all as specified and as directed by Engr-in-Charge.
9S&F in replacement of inverter PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
10S&F in replacement of Noise filter PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
11S&F in replacement of Main control PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
12S&F in replacement of Power/Over Voltage PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
13S&F in replacement of Fan driver PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge. Make-Daikin
14S&F in replacement of Reverse phase PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
15S&F in replacement of earth leakage PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
16S&F in replacement of Magnetic contactor for outdoor unit complete all as specified and as directed by Engr-in-Charge.
17S&F in replacement of Fan motor for outdoor unit for any capacity complete all as specified and as directed by Engr-in-Charge.
18S&F MCB SP 6 - 32 Amps 230 V including taking down old UNSV MCB Complete all as specified and as directed by Engr-in-Charge MakeL&T/Legrand/Schnider/Havells or any equivalent approved make
19Supply & fixing MCB TP 63 Amps 240 volt complete all as specified and directed by Engr- in charge
20S&F MCCB 4 pole 415 volts 160 Amp rotary typebreaking capacity 36 KAincluding taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge. MakeL&T/Legrand/Schnider/Havells or any equivalent approved make
21S&F in replacement of Sheet metal encloseure with 3 pin plug and socket with 20 Amp MCB single pole. Complete all as specified and as directed by Engr-in-Charge. Make : L&T/Legrand/Schnider/Havells or any equivalent approved make
22Supply and Fixing in replacement scroll fix Compressor for outdoor of capacity 12/14 HP as per existing size and model complete all as specified and directed by Engineer-in-charge.
23Note:- (a) One skilled VRF Operator having good knowledge of system will be provided by contractor for daily ON/OFF operation & testing of all indoor & outdoor units and maintaining the record book on daily basis from 09:00 AM to 06:00 PM during opening of NTC Lab. (b) One Electrician for Electric related issues in VRF system for Outdoor Main Electric panels/indoor circuits provided by contractor. (c) Material (submain wire, lugs& cable of suitable size etc.) to resolve the electrical issued occurred on site provided by contractor itself.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail