Tender For Supply Of Rate For Civil, Electrical, Sanitoryand Other Materials At Asra Yojana Auraiya, auraiya-Uttar Pradesh

Uttar Pradesh Jal Nigam-UPJN has published Tender For Supply Of Rate For Civil, Electrical, Sanitoryand Other Materials At Asra Yojana Auraiya. Submission Date for this Tender is 12-06-2023. Building Work Tenders in auraiya Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38046654
Tender For Supply Of Rate For Civil, Electrical, Sanitoryand Other Materials At Asra Yojana Auraiya
Open Tender
Indian
Uttar Pradesh
auraiya
12-06-2023

Tender Details

Supply Of Rate For Civil, Electrical, Sanitoryand Other Materials At Asra Yojana Auraiya As Per Nit And Tender Document , Earth Work In Excavation In Trenches For Foundation Pipes, Cable Etc In Ordinary Sol ( Loam Clay Or Sand ) Inlcuding Lift Upto 1.5 Mt. Lead Upto 30Mt. And Dressing Of Sides And Rammings Of Bottom And Disposal Of Surplus Excavated Earth As Directed By The Engineer. , Upto 1.50 M To 3.00 M Deep , Upto 3.00 M To 4.50 M Deep , Upto 4.50 M To 6.00 M Deep , Filling Of Carted Earth , Laying In Position Cement Concrete Of Specifiedgrade Including The Cost Of Centring And Shuttering-All Work Upto Plinth Level. , In Cement Concrete 1:4:8 ( 1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size ) , In Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Providing And Injecting Chemical Emulsion For Pre Constructional Antitermite Treatment And Creating A Chemical Barrier Under And Alround The Column Pits Wall Trenches Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor, Along The The External Perimeter Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc, Complete. ( Plinth Area Of The Building At Ground Floor Only Shall Be Measured As Per I.S.6313 ( Partii 1981 ) Alderine Emulsifiable Concentrate Or Any Other Approved Material Such As Heptrachlor Or Chlordane Will Be Used. The Rate Of Application Of Chemical Emulsion Shall Be As Follows : ( 1 ) Treatment For Masonary & Foundation 5 Liters Per Sqm. ( 2 ) Back Fill In Immediate Contact With Foundation 7.5 Liters / Sqm ( 3 ) Treatment Of Top Surface Of Plinth Filling 5 Liters / Sqm ( 4 ) Treatment Junction Of Wall And The Floor 7.5 Liters / Sqm ( 5 ) Treatment Of Soil Along External Perimeter Of Building 7.5 Liters / Sqm ( 6 ) Treatment Of Soil Under Apron Along External Perimter 5 Liters / Sqm. ( As Per Manufacturers Standard Dilution ) , R.C.C. Work With Cement Approved Coarse Sand And 2 Cm. Guage Approved Stone Grit In The Proportion Of 1:1.5:3 In Lintels Of Doors And Windows Excluding Supply Of Reinforcement And Its Fixing And Binding The Same With 24 Bwg Binding Wire And Including Necessary Centering And Shuttering Etc.And Also Excluding Supply Of All Materials, And Including Labour And Tools And Plants Etc, Required For Proper Completion Of The Works. , Ground Floor , First Floor , Second Floor , As In Item No. 6 Above But For Slabs ( Using 1:1.5:3 Mix Concrete ) . , Ground Floor , First Floor , Second Floor , As In Item 6 But For Thelighterbeams I.E. Having Spans Upto 6 M. ( Using 1:1.5:3 Mix Concrete ) , Ground Floor , First Floor , Second Floor , As In Item 6 Abovebut Inr.C.C.Raft Foundation And Footingwithapproved Stone Ballast. ( Using1:1.5:3Mix Concrete ) , As In Item 6 Above But In R.C.C. Columns In 1:1.5:3 Having Strength Not Less Than M-20. , Ground Floor , First Floor , Second Floor , M-150 Brick Work In 1:6 ( One Cement And Six Coarse Sand Sand Of 2.25 Fineness Modulus ) Mortar Infoundation & Plinth Includinglabour And T & P Etc & Excluding Supply Of All Materials, Required For Proper Completion Of The Work. , M-150 Brick Work In 1:4 ( One Cement And Six Coarse Sand Sand Of 2.25 Fineness Modulus ) Mortar Infoundation & Plinth Includinglabour And T & P Etc & Excluding Supply Of All Materials, Required For Proper Completion Of The Work. , Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 12.5Mm Nominal Size ) , Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7 Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. , Same As In Item No. 11 Abovebutin Super-Structure Above Plinth Level Up To Floor Two Level ( Up To Two Storeys ) Includingnecessarycutting And Moulding Of Brick Work Asrequiredand Also Including Honeycombed Brick Work In Thickness Of Wall More Than 12Cms. ( 1:6 Cement : Coarse Sand ) , Ground Floor , First Floor , Second Floor , Same As In Item No. 14 But In1:4 Cement And Coarse Sand Mortar In Superstructure For Wall Thickness 12 Cms & Below Brick Work. , Ground Floor , First Floor , Second Floor , Mild Steel Or Iron In Plain Work Such As Reinforced Concrete Or Reinforced, Brick Work ( When Not Included In Over All Rates ) Wrought To Required Shape As Necessary Including Bending For Proper Completion Of The Work And Excluding Supply Of Steel Its Wastage Bend Hooks And Authorised Over Lapping Shall Be Measured Upto Floor Two Level. , Ground Floor , First Floor , Second Floor , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix : 1:3 ( 1 Cement: 3 Coarse Sand ) , 15 Mm Cement Plaster In Single Coat On Rough Side Of Single Or Halfbrick Wall For Interior Plastering Up To Floor Two Level Including Internal Rounded Angles Not Exceeding 80 Mm In Girth And Finshed Even And Smooth. ( 1 ) 1 Cement : 6 Fine Sand . , Ground Floor , First Floor , Second Floor , 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. ( 1 ) 1 Cement : 6 Finesand. , Ground Floor , First Floor , Second Floor , Engraving Lines In The Plaster Of Outer Face Well Vertically & Horizontally To Display The Surface As Stone Facing As Directed By The Engineer-In-Charge Including Labpur, & T & P Etc. Required For Proper Completion Of The Work. , Ground Floor , First Floor , Second Floor , Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. , Laying 8 To 10 Mm Thick Ivory Or Light Shade Vitrified Tiles Of 600 X 600 Mm Size With All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finishing With Cement Slurry & With Pigment Grouting & Polishing Complete Including Supply Of All Labour, T & P Etc. Excluding The Cost Of Materials Required For Proper Completion The Work. , Ground Floor , First Floor , Second Floor , Laying 8 To 10 Mm Thick Ivory Or Light Shade Vitrified Tiles Of 600 X 600 Mm Size With All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finishing With Cement Slurry & With Pigment Grouting & Polishing Complete Including Supply Of All Labour, T & P Etc. Excluding The Cost Of Materials Required For Proper Completion The Work. , Ground Floor , First Floor , Second Floor , Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick , Ground Floor , First Floor , Second Floor , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , Ground Floor , First Floor , Second Floor , Fixing Of 6 Mm Thick Approved China White / Coloured Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar Finished And Jointed With White Cement Slurry And Pigment And Polishing Complete Includinglabour And Tool Sand Plants & Excluding Supply Of All Materials, Etc. Required For Proper Completion Of The Work. , Ground Floor , First Floor , Second Floor , 25 Mm Thick Cement Concrete Flooring 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 12.5Mm Nominal Size And Below ) By Laid Over Base Concrete Finished With Floating Coat Of Neat Cement ( Base Concrete To Be Paid Separately ) Including Fixing Of Glass Strips. ( Excluding Cost Of Glass Strips ) , Supply Of Flush Doors Commercial Qualityconforming To I.S.2202 Part I ( 1983 ) Including Fixing Of Wooden Cleats And Stoppers , 35 Mm Thick , ( A ) Single Leaf , ( B ) Double Leaf , 32 Mm Thick , ( A ) Single Leaf , Extra For Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) , Fixing Of Flush / Pvc Doors Including Fixing Of Wooden / Pvc Cleats And Stoppers And Includingfixing And Adjustment Of Hinges, Bolts, Locks, Handle, Springs. Fittings To Be Supplied Departmentally. , Supply Of Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styles And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc ‘C’ Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree Angle On Both Side Forming Styles And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail. Top, Bottom And Lock Rails Shall Be Provided Both Side Of The Panel. 10 Mm ( 5 Mm X 2 ) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail, Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Styles & Rails With 7 Mm ( 5 Mm+2 Mm ) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interior Side Of The ‘C’ Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturer’S Specification & Drawing. 30 Mm Thick Plain Pvc Door Shutters , Mild Steel Or Iron Work Of Small Sizes And Sections Such As Holding Down Bolts, Hold Fast Tierods, Gratings Etc. ( When Not Included In An Over All Rates ) Wrought To Required From Including Supply Of Steel And Its Wastage Including Cost Of Bolts, Nuts If Required For And Welding, Grinding And Making Holes As Required Completion Of Work Fabrication Of Holes Doors, Chaukhats Nosing. , M.S. Hold Fast For Doors And Windows , M.S. Grill , Z-Section Winodws ( Openable ) , M.S. Angle Door Chaukhat 40*40*5 , Fixing Of Door, Windows / Ventilators Chaukhats In Position. , ( A ) Door Chaukhats , ( B ) Window Chaukhats , ( C ) Ventilator Chaukhats , Distempering ( Two Coat ) With Oil Bound Distemper Of Approved Brand And Manufacture & Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over & Including A Priming Coat With Cement Primer Of Approved Brand & Manufacture Such As Berger, J&N, Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Droppings & Other Foreign Matters & Also Including Preparing The Surface Even With Plaster Of Paris Or Approved Synthetic Material & Sand Papered Smooth Including Cost Ofall Materials. ( Inside Walls ) , Ground Floor , First Floor , Second Floor , Finishing Walls With Two Coat Of Acrylic Smooth Exterior Paint Of Best Quality Including Supply Of All Materials Labour And Tool Sand Plants Etc. Required For Proper Completion Of The Work. , Ground Floor , First Floor , Second Floor , Finishing Wall With Water Proof Cement Paint Of Approved Make And Quality On New Wood With Two Coat To Give An Even Shade Including Supply Of All Materials, Labour, Tools And Plant Etc. Required For Proper Completion Of The Work. ( Two Coat ) , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Materials, Labour, Tools And Plant Etc. Required For Proper Completion Of The Work. ( Two Coat ) , Distempering ( Two Coat ) With Oil Bound Distemper Of Approved Brand And Manufacture & Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over & Including A Priming Coat With Cement Primer Of Approved Brand & Manufacture Such As Berger, J&N, Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Droppings & Other Foreign Matters & Also Including Preparing The Surface Even With Plaster Of Paris Or Approved Synthetic Material & Sand Papered Smooth Excludingcost Of All Materials. ( Ceiling ) , Providing & Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Supply Of 150 Mm Bright Finished Floor Stainless Steel Door Stopper With Rubber Cushion, Necessary Brass Screws Etc. To Suit Shutter Thickness Complete. , Supply Of Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . , Supply Of Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete , ( A ) 300Mm X 10Mm , ( B ) 250 Mm X 10Mm , Supply Of Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm , Providing And Laying Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: A ) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. B ) Laying Brick Bats With Mortar Using Broken Bricks / Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming Tois : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs C ) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. D ) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , Painting Or Vanishing Two Coat On Iron Work In Small Areas Or New Wood Work With One Coat Of Ready Mixed Priming Paint And One Coat Of Approved Superior Ready Mixed Paint Of Clear Synthetic Varnish Including Supply Of All Materials, Labour, T & P Etc. Required For Proper Completion The Work. Paint To Be Used Should Confirm To The I.S.I. No. 103 1950. , Same As Item Above But On New Wood Surface. , Fixing Panes Of Glass With Equal Or Equivalent I.S.I. Marked Quality Putty, Brads And Springs Including Supply Of All Materials, Labour Etc. Complete. 3.80 To 4.70 Mm Thick , Chequered Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Up To 6 Mm In Floors, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing And Polishing & Excluding Supply Of All Materials Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) : Light Shade Pigment Using White Cement. , Filling Of Light Cinder Filling Under Floor Of Toilets & Other Sunken Roofs. , Labour Charges For Wiring Points For Light With 1.5 Sqmm.Frlsh Pvc Insulated Single Core Copper Condutor Cable In Pvc Conduit Pipe Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5 Sqmm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire And Piano Type Switch Etc. Complete In All Respects. , Same As Item No. ( 1 ) But For Two Way Light Points. , Same As Item No. ( 1 ) But For Fanandlight Duty Exhaust Fan. , Same As Item No. ( 1 ) But For5amp Plug Point With Piano Type Switch And Socket Etc. , Addition When Modular Type Switches Etc Are Used In Place Of Piono Type Switches Etc. In Various Wiring Points. , Addition For Light / Fan Points With Modular Type Switchin Place Of Piono Type Switch. , Addition For Plugpointswith Modular Type Switchin Place Of Piono Type Switch. , Addition For Exhaust Fanpointswith Modular Type Switchin Place Of Piono Type Switch. , Wiring Of Submains With 2 Nos. 2.5 Sq.Mm & With 1 No. Earth Wire Of 1.5 Sq.Mm Fr Pvc Insulated 1100 V Grade Single Core Multistrand Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2Mm Thick ) Pvc Conduit Complete, Including Supply Of All Material, Labourand T&P Etc. Required For Proper Completion Of The Work As Directed By Engineer I / C. , Wiring Of Submain 2 Number 4 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 20Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 2.5 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Wiring Of Submain 2 Number 6 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 20Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 4 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Wiring Of Submain 4 Number 10 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 32Mm Dia Pvc Conduitalong With Two Numbers 6 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductorcable As Earth Contunity Wire Etc. Complete In All Respects. , Wiring Of Submain 4 Number 16 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 40Mm Dia Pvc Conduitalong With Two Numbers 10 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Wiring Of Submain 4 Number 25 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 50Mm Dia Pvc Conduitalong With Two Numbers 16 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Fixing And Concealing Of20mm Dia.2Mm Thick Pvc Conduit Pipe With Isi Mark Embossed And With Pvc Acessories Confirming To Is No. 3419 For Drawing Wires Duly Sealed At Joints With Original Resin / Adhesive To Make The Complete Piping Rigid, Plastering With Cement Sand Mortar Finished To Level With Matching Colour Including Cost Of Material Labour And T & P Etc Required For Proper Completion Of Work ( Fortelephone ) , Erection And Testing Of Ceiling Fan And Regulator For Room Height Upto 3.5Mts. Including Supply Of 3Mm Thick G.I. Pipe 19Mm Dia Duly Painted, Complete In All Respects. , Erection And Testing Exhaust Fan On The Exhisting Hole With Suitable Size Of Rag Bolts Nuts And Washers Etc. Complete In All Respects. , Fixing Of Hexagonal / Round G.P. Fan Box Of Approved Make Made Up Of 1.0Mm Thick Isi Marked G.P. Sheet Spot Weeldeed Four To Eight Holes Of 25.4 Mm For Pipe Entry Of The Box. Holes Should Be Semi-Shuttered Type With 0.5Mm G.P. Sheet Made Upper & Lower Cover Duly Screewed Fitted With 300Mm Round Zink Coted M.S Bar X 12Mm & Brand Name Should Be Embossed.Fixing With Wiring Conduit Laid In The R.C.C Roof Before Concreting Alongwith Supply Of All Material, Labour, T&P Etc. Required For Proper Completion Of The Work. , Supply Of Ceiling Fan With Fan Motor Of A.C Permanent Insulation, Capacitor Rating Conforming Bee 5 Star Rating And Is:374 / 79 And Also Comply With Is: 1709 / 1984 With Latest Amendment. The Rated Voltage 220 / 240 Volts, 50Hz, 1-Ph Ac The Fan Assemble Should Consists Of Down Road Blades, Shackle Canopies Etc And With Double Ball Bearing System. Bee 5 Star Rated-1200Mm Sweep , Fixingofelectronic Fan Regulator ( Modular ) 120-280 V. Isimarked, On The Existing Switch Board Including Making Connetion, Required Material, Labour T / P Etc For Proper Completion Of Work To The Satisfaction Of Engineer In Charge Of Work. , Fixing Of Led Tube Light With Metal Heavy Dutybox Type Batten Light Fitting 2 X 22 Watt Suitable For Up To 2 X 22 Watt Led Polycarbonate Tube Light Complete Including Tube Etc Suitable For Both Surface & Surface Complete In All Respects. ( Cat: Aaa ) , Fixing Of Led Tube Light With Metal Heavy Dutybox Type Batten Light Fitting 1 X 22 Watt Suitable For Up To 1 X 22 Watt Led Polycarbonate Tube Light Complete Including Tube Etc Suitable For Both Surface & Surface Complete In All Respects. ( Cat: Aaa ) , Fixing Of Recess / Surface Mounting Round 10 To 15 Watt, Cut Out Min 125Mm, Height Min 40Mm, Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflector And Driver Set, Suitable For 24Hr Continuous Operation, Complete In All Respect. ( Cat: Aaa ) , Fixing Of Single Led Light Wall Bracket On Matching M.D.F.E.G Board Base Etc. Complete In All Respect. ( Cat: Aaa ) , Fixing Of Water Tight Oblong 10 Watt Led Bulhead Luminaire With Driverr Set Confirming To Ip 65 And Above Protection Complete In All Respect. ( Cat: Aaa ) , Fixing Of Surface / Flush Mounting Distribution Boards With Additional Metal Door Withot Mcb Complete In All Respects. ( Cat A ) , 4 Way Tpn , 6 Way Tpn , 8 Way Tpn , Fixing Of 6Amp To 32 Amp ( 10 Ka ) Sp Mcb In Existing Mcb, Db Complete With Connections As Required. ( Cat: A ) , Fixing And Making Connection Of Following Mcbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) , 40 Amp. Fp Mcb ( Cat: A ) , 63 Amp. Fp Mcb ( Cat: A ) , Fixing Of Surface / Flush Mounting V Tpn Distribution Boards With Additional Metal Door Withot Mcb Complete In All Respects. ( Cat A ) 4 Way V Tpn , Fixing And Making Connection Of Following Mccbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) , 100 Amp. Fp Mccb ( Cat: A ) , 125 Amp. Fp Mccb ( Cat: A ) , 160 Amp. Fp Mccb ( Cat: A ) , Fixing And Making Connection Of Following Mcbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) , 40 Amp. Tp Mcb ( Cat: A ) , 63 Amp. Tp Mcb ( Cat: A ) , Fixing Of Power Plug With 15A / 250 V Flush Type Switch And 5 Pin 15 A / 250V Flush Type Universal Socket In Suitable M.S. Box Of 175Mmx100x50mm Size With Phenolic Laminated Bakellite Sheet Cover 3Mm Thick Fixed With Brass Machine Screws And Cup Washer. , Fixing Of Power Plug With 20A / 250 V Flush Type Switch And 5 Pin 20 A / 250V Flush Type Universal Socket In Suitable M.S. Box Including Supply Of All Material, Labor T&P Etc. Required For Proper Completion Of Work. , Fixing Of Single Pole Mcbs Blanking Plate Complete In All Respects. ( Cat: A ) , Fixing And Making Connection Of Following Mccbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. 63 Amp. Fp Mccb , Supply And Burying Of 600Mm X 600 Mmx6mm G.I. Plate, Vertically For Earthing With Its Top Atleast 3 Mts. Below Ground Level Complete With 20Mm G.I.Pipe And Funnel For Watering And Two Earthing Leads Of No.8To10swg G.I.Wire In 15Mm Dia G.I. Pipe Upto Switch Board ( From Apron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm. Square C.I. Frame With Hinged Cover, Masonary Housing, Alternate Layers / Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. Complete In , Laying Of 25Mmx3mm G.I. Strip For Earthing Purpose As Required Complete In All Respects. , Fixing Of Two Number 8 Swg G.I. Wire In 15Mm Dia Gi Pipe For Earthing Purpose As Required Complete In All Respects. , Laying Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1000 Bolts Grade At A Depth Of 750Mm Below Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And Top On Surface, The , 95 Sqmm3.5 Core , 70 Sqmm3.5 Core , 50 Sqmm3.5 Core , 35 Sqmm3.5 Core , 25 Sqmm3.5 Core , 10 Sqmm4 Core , Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Dire , 95 Sqmm3.5 Core , 70 Sqmm3.5 Core , 50 Sqmm3.5 Core , 35 Sqmm3.5 Core , 25 Sqmm3.5 Core , 10 Sqmm4 Core , Fixing Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape And Making Of Connections Etc. Complete In All Respects As Per Direction Of Engineer-Incharge. , 95 Sqmm , 70 Sqmm , 50 Sqmm , 35 Sqmm , 25 Sqmm , 16 Sqmm , 10 Sqmm , 6 Sqmm , Fixing Ofmodular Boxes, Base & Cover Plate , Fixing Of Following Size / Modules, Gi Box Along With Modular Base& Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mm X 75 Mm ) , Fixing Ofmodular Type Switch / Socket :- , Fixing Of Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc As Required. , Telephone Socket Outlet , Tv Antenna Socket Outlet , Bell Push , Fixing Of Call Bell / Buzzer Suitable Single Phase, 230 V Etc As Required. , Laying Oftelephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair , Drawing Of Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Drawing Telephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , 20 Pair , 10 Pair , Fixing Of 10 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same , Fixing Of 20 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same , Fixing Of 50 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same , Laying Unplastisized Rigid Pvc Pipe Conforming To Is:13592 Type A Including Jointing , Cuttingand Making Good The Walls & Floors As Per Requirement. 150Mm , Supply Of Ac 230 / 250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required 300Mm Sweep. , Fixing Of Energy Meter And Other Accessories Including Connections Etc. Complete As Required 3 Phase Meter , Erection Of Ac 230 / 250 Volts, 50 Hz Wall Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required450mm Sweep. , Supply Of Ac 230 / 250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required450mm Sweep. ( At Labs ) , Fixing Of Wired Decorative Mirror Light On Suiatable For 9 Watt Led With Lamp Complete In All Respect. , Fixing Of Factory Wired Integral Led Flood Light Luminaires With Die Cast Aluminium Housing Built With Driver Set Suitable For 40 To 50 Watt Conforming To Ip 65 / 66 Protection Complete In All Respect. ( Cat-Aaa ) , Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement@ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm.This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , Fixing Of Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, Excluding The Cost Of Materials On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge. , Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Control System For Various Vertical Localtion In Load Application Areas Thatccommodates Multi Directional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions.The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirement All As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) Floor Joint Of 100 Mm Gap , Providing And Fixing Of Expansion Joint System Of Approved Make And Manufactures For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Base Members With, Self Aligning And Self Centering Arragement Support Plates Asper Astm B221-02. The System Shall Be Such That It Provides Watertight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement , And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Verticalisplacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063. ) Roof Joint Of 100 Mm Gap , Providing And Fixing Of Expansion Joint Systemelated With Wall Joint ( Internal / External ) Location As Per Drawings And Direction Of Engineer-In- Charge. The Joints Shall Be Of Extruded Aluminum Base Members, Self Aligning / Centering Arrangement And Support Plates As Per Astm B221- 02. The Material Shall Be Such That It Provides An Expansion Joints System Suitable For Vertical Wall To Wall / Wall To Corner Application, Both New And Existing Construction In Office Buildings & Complexes With No Slipping Down Tendency Amongst The Components Of The Joint System. The Joint System Shall Utilize Light Weight Aluminum Profiles Exhibiting Minimalexposed Aluminum Surfaces Mechanically Snap Locking The Multicellular To Facilitate Movement. ( Material Shall Confirm To Astm 6063 ) .Wall Joint Of 100 Mm Gap , Fixing In Position Stainless Steel Grade 304 Plate-1.0 Mm Thick As Per Design For Expansion Joints. 200 Mm Wide. , Granite Stone Slab 18 Mm Thick Mirror Polished Quarter Rounded With Anti Skid Lines In Treads Of Staircase Full Length Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Cement Slurry Mixed With Pigment To Match The Shade Of Including Rubbing & Polishing Complete With Base Of Cement Mottar 1:4 ( 1 Cement : 4 Coarse Snad ) Etc. Complete Excluding The Cost Of Materials. , Ground Floor , First Floor , Second Floor , Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Ocking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer & Excluding The Cost Of Materials. , Fixing Rolling Shutters Of Approved Make Of 80 × 125 Mm ( 3 × 18 Gauge ) Cold Rolled Ml Lath Inter Lockedthrough Their Eintire Length And Joined Together At The End By Locks And Mountedon Specially Designed Pipe Shaft With Brackets And Wall Bearing & Excluding The Cost Of Materials. , 40Mm Thick Cement Concrete Flooring 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size And Below ) By Laid Over Base Concrete Finished With Floating Coat Of Neat Cement ( Base Concrete To Be Paid Separately ) Including Fixing Of Glass Strips. ( Excluding Cost Of Glass Strips ) , Fixing Glass Strips In Joints Of Floors And Skirting Or Dado Add The Item Of Laying Floors Flush With Floor Level Including Supply Of All Materials, Labour, T & P Etc. Required For Proper Completion The Work. ( A ) 37 Mm Wide And 3.15 Mm Thick , 52 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 40 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) And Top Layer 12 Mm Thick Cement Hardener Consisting Of Mix 1:2 ( 1 Cement Hardener Mix : 2 Graded Stone Aggregate 6 Mm Nominal Size ) By Volume, Hardening Compound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per Manufacturers Specifications.But Excluding The Cost Of Materials Etc. Complete. , Supply Of 80Mm Thick Rubber Moulded Cement Concrete Interlocking Pavers Block. The Compressive Strength Of Concrete Pavers Blocks Shall Not Be Less Than 30Mpa & 4.5Kg / No. , Providing And Laying Of 80Mm Thick Rubber Moulded Cement Concrete Interlocking Pavers Block. The Compressive Strength Of Concrete Pavers Blocks Shall Not Be Less Than 30Mpa & 4.5Kg / No. , Fixing Of Angle Iron Frame 40X40x6 Mm In Position. , Fencing With R.C.C. Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres ( Minimum ) , Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post ( Cost Of R.C.C. Posts, Struts, G.I. Barbed Wire, Earth Work And Concrete To Be Paid For Separately ) , Mild Steel Or Iron Work In Heavy Sizes Such As Trusses Built Up Gates, Door Frames, Record Racks, Roof Work Gates Etc. Wrought To Required From Including Supply Of Steel And Its Wastage Including Cost Of Bolts, Nuts If Required For And Welding, Grinding And Making Holes As Required Completion Of Work Fabrication Of Holes Doors, Chaukhats Nosing. , Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With 2Nd Class Teak Wood Beading 62X19 Mm. , Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. Extra For Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) On One Side Only , P / F Curtain Rods Of 1.25Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete ( A ) 25 Mm Dia. , Fixing Of G.I. Pipe ( 80 Mm Dia ) As Per Design & Drawing As Per Drection Of Eic , Fabrication Of Angle Iron Door Chaukhat Of 40*40*6 Mm , Supply Of Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M ) , Having 50 Nos Rounds Per 6 Metrelength, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y’ Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape ( R.B.T. ) / Spring Core ( 2.5Mm Thick ) Wire Of High Tensile Strength Of 165 Kg / Sq.Mm With Tape ( 0.52 Mm Thick ) And Weight 43.478 Gm / Metre. , Fixing Of Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M ) , Having 50 Nos Rounds Per 6 Metrelength, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y’ Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape ( R.B.T. ) / Spring Core ( 2.5Mm Thick ) Wire Of High Tensile Strength Of 165 Kg / Sq.Mm With Tape ( 0.52 Mm Thick ) And Weight 43.478 Gm / Metre ( Cost Of Materialsshall Be Paid Separately ) , Supply Of M.S. Foot Rest As Per Standard Design With 20X20mm Sq Bars. , Fixing Of M.S. Foot Rest Including Fixing With 20X20x10 Cm. Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Gradded Aggregate Of Nominal Size 20Mm ) As Per Standard Design With 20X20mm Sq Bars. , Supply Ofc.I. Tee At The Inlet And Outlet Of Septic Tank. , Fixing C.I. Tee At The Inlet And Outlet Of Septic Tank. , Supply Of 75Mm Dia Vent Pipes. , Fixing Of 75Mm Dia Vent Pipes. , Supply Of 75Mm Dia Cast Iron Terminal Guard. , Fixing Of 75Mm Dia Cast Iron Terminal Guard. , Supply Ofprecast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality. , M.D. -10- Circular Shape 500Mm Internal Diameter , M.D. -2.5- Circular Shape 450Mm Internal Diameter , Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality. , M.D. -10- Circular Shape 500Mm Internal Diameter , M.D. -2.5- Circular Shape 450Mm Internal Diameter , Excavating Trenches In All Kinds Ofsoil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. , Up To 1.50 M Depth , Pipes 80 Mm To 300 Mmdiameter , 1.50 M To 3.00 M Depth , Pipes 80 Mm To 300 Mmdiameter , Opentimbering In Trenches Including Shuttering And Shoring Complete. ( Measurement To Be Taken Of The Face Area Timbered ) , Depth Not Exceeding 1.5 Meter , Depth 1.5 To3.00Meter , Supply Of Non Pressurenp 2 Class ( Light Duty ) Rcc Pipe With Collars Etc. Complete. , 150 Mm.Dia. Rccpipes , 250 Mm.Dia. Rccpipes , 100 Mm Dia Rcc Pipes , Laying Of Nonpressurenp 2 Class ( Light Duty ) Rcc Pipe With Collars Jointed Withstiffmixtureofcement Mortar In The Proportion Of 1:2 ( 1Cement : 2 Finesand ) Includingtestingof Joints Etc. Complete. , 150 Mm.Dia. Rccpipes , 250 Mm.Dia. Rccpipes , 100 Mm Dia Rcc Pipes , Laying Cement Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) Upto The Haunches Of Pipes Including Bed Concrete As Per Standard Design , 150 Mm.Dia. Rccpipes , 250 Mm.Dia. Rccpipes , 100 Mm Dia Rcc Pipes , Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) Rcc Top Slab With 1:2:4 Mix ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size ) Inside Plastering 12Mm Thick With Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. , Inside Size 90X80cms And 45Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15Kg ) . , Extra For Depth For Manholes: , Inside Size 90X120cms And 90Cms Deep Including Ci Cover With Frame ( Medium Duty ) 455X610mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58Kg ) . , Extra For Depth For Manholes: , Supply Of Orange Colour Safety Footrests Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is:10910 On 12 Mm Dia Steel Bar Conforming To Is:1786 Having Minimum Cross Section As 23 Mm X 25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Thread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having Manufactures Permanent Identification Mark To Be Visible Even After Fixing. , Fixing Of Orange Colour Safety Footrests Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is:10910 On 12 Mm Dia Steel Bar Conforming To Is:1786 Having Minimum Cross Section As 23 Mm X 25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Thread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having Manufactures Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. , Supply Of Double Flanged ( Screwed / Welded ) Centrifugally ( Spun ) Ductile Iron Pipes Of Class K-9 Conforming To Is 8329 100Mm Dia Ductile Iron Double Flanged , Fixing & Laying Double Flanged ( Screwed / Welded ) Centrifugally ( Spun ) Ductile Iron Pipes Of Class K-9 Conforming To Is 8329 100Mm Dia Ductile Iron Double Flanged , Supply Of Ci Specials Such As Bends, Reducers, Collars Etc. Including Cartage, Loading, Unloading, Taxes, Excise Etc. Complete. , Fixing Of Ci Specials Such As Bends, Reducers, Collars Etc. Including Cartage, Loading, Unloading, Taxes, Excise Etc. Complete. , Supply Of Push-On-Joints To Centrifugally ( Spun ) Cast Iron Pipes Or Ductile Iron Pipes Including Testing Of Joints And Including The Cost Of Rubber Gasket : 100Mm Dia Pipes , Fixing Of Push-On-Joints To Centrifugally ( Spun ) Cast Iron Pipes Or Ductile Iron Pipes Including Testing Of Joints And Including The Cost Of Rubber Gasket : 100Mm Dia Pipes , Supply Ofc.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) : 100Mm Diameter , Fixing Of C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) : 100Mm Diameter , Supply Of C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc. If Required Will Be Paid Separately. A ) 50Mm Dia , Fixing Of C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc. If Required Will Be Paidsaperately 50Mm Dia , Supply Of G.I. Pipes ( Medium ) Complete With G.I. Fittings , 80Mm Nominal Bore. , 65Mm Nominal Bore. , 50Mm Nominal Bore. , 40Mm Nominal Bore. , 32Mm Nominal Bore. , 25Mm Nominal Bore. , 20Mm Nominal Bore. , 15Mm Nominal Bore. , Laying, Jointing, Testing & Commisioning Ofg.I. Pipes Complete With G.I. Fittings Includingtenching And Refilling Etc. ( External Work ) , 80Mm Nominal Bore. , 65Mm Nominal Bore. , 50Mm Nominal Bore. , 40Mm Nominal Bore. , 32Mm Nominal Bore. , 25Mm Nominal Bore. , 20Mm Nominal Bore. , 15Mm Nominal Bore. , Supplying Of Specials For Pressure Pipe. , Fixing Of Specials For Pressure Pipe. , Supply Ofgate Valve ( With Cap Complete With Bolts, Nuts, Rubber Insertion Etc. , 80Mm Nominal Bore. , 65Mm Nominal Bore. , 50Mm Nominal Bore. , 40Mm Nominal Bore. , 32Mm Nominal Bore. , 25Mm Nominal Bore. , Fixing Of Gate Valve ( With Cap Complete With Bolts, Nuts, Rubber Insertion Etc. , 80Mm Nominal Bore. , 65Mm Nominal Bore. , 50Mm Nominal Bore. , 40Mm Nominal Bore. , 32Mm Nominal Bore. , 25Mm Nominal Bore. , Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm, Top Diameter, 160 Mm Bottom Diameter And 180Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement :5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Chamber 600 X 600X750mm Insidewithf.P.S. Brickwork In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve / Air Valve, With C. I. Surface Box 100 Mmtop Diameter, 160 Mm Bottom Diameter And 180Mm Deep ( Inside ) With Chained Lid And Rcc Top Slabwith 1 : 2 : 4 Mix ( 1 Cement : 2 Coarsesand : 4 Gradestone Aggregate 20 Mm Nominal Size ) ; Necessary Excavation, Foundationconcrete 1:5:10 ( 1 Cement : 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plasteringwithcement Mortar 1 : 3 ( 1 Cement : 3 Coarsesand ) 12Mmthick Finished With A Floatingcoatofneat Cementcomplete As Per Standarddesign , Supply Offire Brigade Inlet With 63 Mm Dia Instantaneous Inlet Complete With All Necessary Fittings And Ms Enclosure With Glass Door Made Of 18 / 16 Swg Sheet. 4 Way , Fixing, Installation, Testing & Commissioning Offire Brigade Inlet With 63 Mm Dia Instantaneous Inlet Complete With All Necessary Fittings And Ms Enclosure With Glass Door Made Of 18 / 16 Swg Sheet. 4 Way , Supply Of Sluice Valve Complete With Flanges, Gasket, Nut Bolts 150 Mm , Fixing, Installation, Testing & Commissioning Of Sluice Valve Complete With Flanges, Gasket, Nut Bolts 150 Mm , Supply Of Nrv Complete With Flanges, Gasket And Nut Bolts. 150 Mm , Fixing, Installation, Testing & Commissioning Of Nrv Complete With Flanges, Gasket And Nut Bolts. 150 Mm , Supply Of Ms Pipes Conforming To Is:1239 ( Medium- B Class ) Including All Fittings Like Anchor Fasteners, Brick Masonry Supports, Couplings, Bends, Elbows, Tees And Flanges Etc. Welded Or Screwed Joints As Required ( For Riser ) , 150 Mm Dia , 100Mm Dia , Fixing Of Ms Pipes Conforming To Is:1239 ( Medium- B Class ) Including All Fittings Like Anchor Fasteners, Brick Masonry Supports, Couplings, Bends, Elbows, Tees And Flanges Etc. Welded Or Screwed Joints As Required, Cutting Holes And Chases In Brick Or Rcc Walls And Making Good Complete. ( For Riser ) , 150 Mm Dia , 100Mm Dia , Supply Of Manual Swing Type First Aid Fire Hose Reel Conforming To Is: 444 Complete With All Other Necessary Fixing Accessories. , Fixing, Installation, Testing And Commissioning Of Manual Swing Type First Aid Fire Hose Reel Conforming To Is: 444 Complete With All Other Necessary Fixing Accessories. , Supply Of Fire Man Axe. , Fixing Of Fire Man Axe. , Supply Of Singal Headed Hydrant Landing Valve Comprising Of 80 Mm Dia Flanged Bend 63 Mm Dia, With Cap And Chain Conforming To Is:5290 ( Make : Newage / Minimax / Safex / Firex ) , Fixing, Installation, Testing & Commissioning Of Singal Headed Hydrant Landing Valve Comprising Of 80 Mm Dia Flanged Bend 63 Mm Dia, With Cap And Chain Conforming To Is:5290 ( Make : Newage / Minimax / Safex / Firex ) , Supply Of Rrl Hose Pipe 63 Mm Dia × 15 Mtr. Long With Gm Coupling Conforming To Is : 636 ( Make - Newage / Jayshree / Crc ) , Fixing, Installation, Testing & Commissioning Of Rrl Hose Pipe 63 Mm Dia × 15 Mtr. Long With Gm Coupling Conforming To Is : 636 ( Make - Newage / Jayshree / Crc ) , Supply Of Short Branch Pipe As Per Is:903 ( Make : Newage / Safex / Firex ) , Fixing, Installation, Testing & Commissioning Of Short Branch Pipe As Per Is:903 ( Make : Newage / Safex / Firex ) , Supply Of Butterfly Valve Complete With Flanges, Gasket, Nut Bolts 100 Mm , Fixing, Installation, Testing & Commissioning Of Butterfly Valve Complete With Flanges, Gasket, Nut Bolts 100 Mm , Supply Of Hose Cabinet Box Of 18 Swg M.S.Sheet With Glass To Accommodate Hose Reel Drum With Ruber Pipe With Nozzle. 2 Nos. Rrl Hose And 1 No. Branch Pipe With Nozzle , Fixing, Installation, Testing & Commissioning Of Hose Cabinet Box Of 18 Swg M.S.Sheet With Glass To Accommodate Hose Reel Drum With Ruber Pipe With Nozzle. 2 Nos. Rrl Hose And 1 No. Branch Pipe With Nozzle , Supply Of Air Cushion Tank ( 2000X1000 ) Mm. , Fixing, Installation, Testing & Commissioning Of Air Cushion Tank ( 2000X1000 ) Mm. , Supply Of Air Release Valve. , Fixing, Installation, Testing & Commissioning Of Air Release Valve. , Supply Of Nrv Complete With Flanges, Gasket And Nut Bolts. 100 Mm , Fixing, Installation, Testing & Commissioning Of Nrv Complete With Flanges, Gasket And Nut Bolts. , Supply Of Pressure Gauge With Gauge Cock , Fixing, Installation, Testing & Commissioning Of Pressure Gauge With Gauge Cock , Supply Of Electrical Motor Driven Fire Pump Suitable For Automatic Operation Consisting Of Following : ( Terrace Pump ) ( Make : Kirloskar / Mather+Platt ) ( A ) Horozontally Mounted, Split Casing, Centrifugal Fire Pump Complete For Delivery Of Under Mentioned Discharge Against Desired Mentioned Head So As To Ensure A Minimum Pressure Of 30 Meter At The Highest And Farthest Outlet At The Specified Flow Cmplete With Necessary Strainers, Pressure Gauge Including Bypass Arrangement For Periodic Testing Of The Working Of The Pumpset With Required Length And Size Of Medium Class Gi Pipe And Control Valves For Proper Completion Of Work.The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head.The Pump Shall Be Provided With Mechanical Seals. The Impeller Shall Be Enclosed Type And Accurately Blanced Dynamically.The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. ( B ) Squirrel Cage, Tefc Induction Motor Suitable For 415 V, 3 Phase Having Ip 55 Protection And Class B Insulation For The Above Pump And Flexible Coupling With The Pump.The Motor Shall B Rated For Continuous Duty And Shall Have Hp Rating Necessary To Drive Th Pump At 150% Of Its Rated Discharge At 65% Of Rated Head. © Common Bed Plate Of Fabricated Mild Steel Channel Or Cast Iron Type. ( D ) Suitable Cement Concrete Pump Foundation And Vibration Clamping Arrangement As Required With Foundation Bolts, Anti Vibration Pads, Washers Etc. ( E ) Pressure Switch For Automatic Operation Of Motor Including Necessary Wiring Upto Control Panel. ( F ) Electrical Control Panel With Starter, 3 Pole Motor Protection Category Current Limiting Type Mccb, Indicating Light, Ammeter, Voltmeter, Selector Switches, Cts Protective Fuses, Single Phasing Protection, Dry Suction Cut Off Etc As Requrd As Per Standard Details.Discharge :450 Liter Per Minute Head : 35 Meter , Installation, Testing And Commisioning Of Electrical Motor Driven Fire Pump Suitable For Automatic Operation Consisting Of Following : ( Terrace Pump ) ( Make : Kirloskar / Mather+Platt ) ( A ) Horozontally Mounted, Split Casing, Centrifugal Fire Pump Complete For Delivery Of Under Mentioned Discharge Against Desired Mentioned Head So As To Ensure A Minimum Pressure Of 30 Meter At The Highest And Farthest Outlet At The Specified Flow Cmplete With Necessary Strainers, Pressure Gauge Including Bypass Arrangement For Periodic Testing Of The Working Of The Pumpset With Required Length And Size Of Medium Class Gi Pipe And Control Valves For Proper Completion Of Work.The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head.The Pump Shall Be Provided With Mechanical Seals. The Impeller Shall Be Enclosed Type And Accurately Blanced Dynamically.The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. ( B ) Squirrel Cage, Tefc Induction Motor Suitable For 415 V, 3 Phase Having Ip 55 Protection And Class B Insulation For The Above Pump And Flexible Coupling With The Pump.The Motor Shall B Rated For Continuous Duty And Shall Have Hp Rating Necessary To Drive Th Pump At 150% Of Its Rated Discharge At 65% Of Rated Head. © Common Bed Plate Of Fabricated Mild Steel Channel Or Cast Iron Type. ( D ) Suitable Cement Concrete Pump Foundation And Vibration Clamping Arrangement As Required With Foundation Bolts, Anti Vibration Pads, Washers Etc. ( E ) Pressure Switch For Automatic Operation Of Motor Including Necessary Wiring Upto Control Panel. ( F ) Electrical Control Panel With Starter, 3 Pole Motor Protection Category Current Limiting Type Mccb, Indicating Light, Ammeter, Voltmeter, Selector Switches, Cts Protective Fuses, Single Phasing Protection, Dry Suction Cut Off Etc As Requrd As Per Standard Details.Discharge :450 Liter Per Minute Head : 35 Meter , ( A ) Horozontally Mounted, Split Casing, Centrifugal Fire Pump Complete For Delivery Of Under Mentioned Discharge Against Desired Mentioned Head So As To Ensure A Minimum Pressure Of 30 Meter At The Highest And Farthest Outlet At The Specified Flow Cmplete With Necessary Strainers, Pressure Gauge Including Bypass Arrangement For Periodic Testing Of The Working Of The Pumpset With Required Length And Size Of Medium Class Gi Pipe And Control Valves For Proper Completion Of Work.The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head.The Pump Shall Be Provided With Mechanical Seals. The Impeller Shall Be Enclosed Type And Accurately Blanced Dynamically.The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. , Fixing & Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked Indicating The Bis License No. With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Over Flow Pipes But Without Fitting And Base Support For Tank. [ Sintex, Electroplast, Star, Lotus Or Equivalent Having Valid Isi License ] . , Supply Of Halon Free Portable Fire Extinguishers As Described Below: , 4.5 Kg Carbon Dioxide Extinguisher, Is Marked, With High Pressure Discharge Tube, Horn, Control Valve, Cce Approved Cylinder , 6 Kg Mono Ammonium Phosphate ( Abc ) Type Cartridge Operated Extinguishers , 9 Kg Mono Ammonium Phosphate ( Abc ) Type Cartridge Operated Extinguishers , Providing, Fixing, Testing And Commissioning Of 50 Litres ( Trolley Mounted ) Mechanical Foam Type Fire Extinguisher. In Hp Mild Steel Cylinders Isi Marked Tac Approved Fitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged Complete In All Respects Including Wall Suspension Bracket / Trolley Mounted And Confoming To Is:910 . , Providing, Fixing, Testing And Commissioning Of Co2 Type Fire Extinguisher Of Capacity 22.5 Kg Filled With Co2 Gas As Per Is 15222 With Controll Discharge Mechanism Fitted With Hose, Horn & Trolleyconfirms To Is 2878 Bearing Isi Mark. Co2 Cylinder As Per Is 7285 , Fixing, Storing, Handling, Shifting, Installation, Testing And Commissioning Of Halon Free Portable Fire Extinguishers As Described Below: , Supply Of Fire Related Signages Printed On Photoluminescent U1000 Aluminium Sheet Of 1.0 Mm ( +-10% ) Containing Lumigen Ii As Base Chemical, Covered Under Uv Stablized Coating And Of Appropriate Size For Fixing On Wall, Door, Ceiling Etc. With Proper Clamps, Hangers, Cleats, Anchor Fasteners Etc. Complete. , Fixing Of Fire Related Signages Printed On Photoluminescent U1000 Aluminium Sheet Of 1.0 Mm ( +-10% ) Containing Lumigen Ii As Base Chemical, Covered Under Uv Stablized Coating And Of Appropriate Sizeincluding Fixing On Wall, Door, Ceiling Etc. With Proper Clamps, Hangers, Cleats, Anchor Fasteners Etc. Complete In All Respects As Directed By Engineer-In-Charge. , Supply Ofci Cover With Frame Light Weight Complete As Perdesign Size 600X600 Mm , Supply Ofci Cover With Frame Light Weight Complete As Perdesign Size 900X900 Mm , Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer -In-Charge, Beyond 90 Metre & Upto 150 Metre Depth Below Ground Level.Drilling Of 250 Mm Dia Bore Hole Manually. , Supply Of Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge.150 Mm Nominal Size Dia , Assembling, Lowering And Fixing In Vertical Position In Bore Well Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Hire & Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge.150 Mm Nominal Size Dia , Supply Of Stone Boulders Of Size Range 5 Cm To 20 Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Supply Of Gravels Of Size Range 5 Mm To 10 Mm, In The Recharge Pit, Over The Existing Layer Of Boulders, In Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Supply Of Coarse Sand Of Size Range 1.5 Mm To 2 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. , Filling, Spreading & Leveling Coarse Sand, Gravels & Stone Boulders Of Size Range 1.5 Mm To 20 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. , Transportation Charges Of Drilling Equipment Including Assembly And Other Material As Required. , Drilling Of 675 Mm. Dia By Rotary Machine , Supply Of 350 Mm. Dia Housing Pipe ( 8 Mm. Thick ) , Laying Of 350 Mm. Dia Housing Pipe ( 8 Mm. Thick ) , Supply Of 200 Mm. Dia Blind Pipe ( 8 Mm. Thick ) , Laying Of 200 Mm. Dia Blind Pipe ( 8 Mm. Thick ) , Supply Of 200 Mm. Dia Slotted Pipe ( 8 Mm. Thick ) , Laying Of 200 Mm. Dia Slotted Pipe ( 8 Mm. Thick ) , Supply Of 350 Mm. Dia Socket , Fixing Of 350 Mm. Dia Socket , Supply Of 200 Mm. Dia Socket , Fixing Of 200 Mm. Dia Socket , Supply Of 200 Mm. Dia Bail Plug , Fixing Of 200 Mm. Dia Bail Plug , Supply Of 350 Mm. Dia Well Cap , Fixing Of 350 Mm. Dia Well Cap , Supply Of 350X200 Mm. Dia Reducer. , Fixing Of 350X200 Mm. Dia Reducer. , Supply Of 350 Mm. Dia Housing Clamp , Fixing Of 350 Mm. Dia Housing Clamp , Supply Of Pee Gravel 2 Mm. 4 Mm. In Side Of Bore After Lower And Development As Required As Per Direction Of E / I. , Filling Of Pee Gravel 2 Mm. 4 Mm. In Side Of Bore After Lower And Development As Required As Per Direction Of E / I. , Development By Air Compressor Including Transportation. , Development By O.P. Unit Including Transportation. , Supply Of 7.5 Hp Ksb Make Submersible Pump Set Model Bpd 302 / 4+Uami 150 / 6 / 22-203 ( S / D ) Suitable For Tube Well Capable Of Pumping Clear And Cold Water Free From Chemical And Directly Coupled With Ksb Electric Moter Operating Of 415 Volt Suitable For 3 Phase 50 Cycle A.C. Supply Of Following Duty Condition 7.5 Hp 6 Stage Pipe.A - Discharge Of Water In Lpm 860 Approx Size Of Discharge Outlet In 80 Mm.B - Total Head Of Pump Set 45 M. , Supply Of Finolex Or Equivalent Isi Marked Submersible Copper Cable Of Size 2X3x2.5 Sq. Mm. , Fixing Of Finolex Or Equivalent Isi Marked Submersible Copper Cable Of Size 2X3x2.5 Sq. Mm. , Supply Of Control Panel Cubical Type Wall Mounted Vermin Proof With Internal Wiring Duly Enameled Painted And Mechanically Finished Having L&T Of Qul. Male Switch Fuse Unit With Hrc Fuses, Ameter, Boltmeter, Selector Switch, Phase Indicating Lamp With Bulbs, Instrument Fuses, Power Capcitor Single Phase Preventor Etc. Complete Set With Supply Of Jyoti Or Eq. Air Break Star- Delta Motro Starter Suitable For Above Submersible Pump Set. , Supply Of 80Mm Dia M.S. Column Pipe Of Class C Both And Socketed With Heavy Sockets In 3 / 6 Meter Length And One End Flanged Complete With Interlocking Arrangements. , Lowering Of 80Mm Dia M.S. Column Pipe Of Class C Both And Socketed With Heavy Sockets In 3 / 6 Meter Length And One End Flanged Complete With Interlocking Arrangements. , Supply Of 80Mm Dia M.S. Column Pipe Clamps With Nut, Bolts, Packing Etc. , Lowering Of 80Mm Dia M.S. Column Pipe Clamps With Nut, Bolts, Packing Etc. , Supply Of 80Mm Dia C.I. Double Flanged Isi Mark Reflex Valve Of Updadhya Or Equ. Make. , Fixing Ofc.I. Double Flanged Reflex Valve , Supply Of 80Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel Of Upadhya Or Equ. Make. , Supply Of 100 Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel Of Upadhya Or Equ. Make. , Supply Of 150Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel Of Upadhya Or Equ. Make. , Fixing Of 80 / 100 / 150 Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel , Supply Of C.I. Double Flanged Bend Of 80Mm Dia , Fixing Of C.I. Double Flanged Bend Of 80Mm Dia I / C Cost Of Labour. , Supply Of 80Mm Dia C.I. Tee Heavy Quality I / C Cost Of Material. , Fixing Of 80Mm Dia C.I. Tee Heavy Quality , Supply Of Guru / Fibing Or Equivalent Make Pressure Gauge. , Fixing Of Pressure Gauge. , Erection & Commissioning Of Pumping Plants Complete Along With Electric Wiring. , Supply Of Steel Wire Rope Of 1 / 2 Size , Fixing Of Steel Wire Rope Of 1 / 2 Size , S / B Of 600Mm X 600 Mm X 6.0 Mm G.I. Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I. Pipe And Funnel For Watering And One Earthing Lead On One No. 8 To 10 Swg Gi Wite In 15Mm Dia G.I. Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I. , Pipe And G.I. Wire Will Be Extra ) 30 Cm Square C.I. Frame With Hinged Cover Masonry Housing Alternate Layers Of Charcoal. Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of E / I Complete In All Respects As Per Drawing. , S / F Of One Number 8 To 6 Swg G.I. Wire In 15Mm Dia G.I. Pipe For Earthing, Laid In Ground Or In Wall Duly Concealed Includingn The Cost Of Cement, Sand Labour. T&P Other Material Required For Proper Completion Of The Work As Directed At Site. , S / F Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheathed Cable 1100 Volts Grade16 Sqmm X 4 Core , Fixing Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheathed Cable 1100 Volts Grade At A Depth Of 750Mmbelow Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And On Top.On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By E / I Complete In All Respects The Armoring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc.16 Sqmm X 4 Core , Supply Of 500 Kva. 11 / 0.433 Kv, 3Phase, 50Hz, Dyn 11, Oil Type, ( Uppcl Approved Make ) Copper Wound Transformer With Off Load Tap Changing Arrangement On Hv Side In Steps Of + / - 2.50%, + / - 5% & - 7.5% , Having Cable End Boxes On Hv Sideand 800 Amp. Bus Trunking Arrangement On Lv Side Complete With All Accessories I / C First Filling Of Filtered Dehydrated Oil And Confirming To Is 2026 ( Part 1 To Part 5 ) & As Per Specification Attached Complete In All Respects As Required At Site. , Installation, Testing And Commissioning Of 500 Kva. 11 / 0.433 Kv, 3Phase, 50Hz, Dyn 11, Oil Type, ( Uppcl Approved Make ) Copper Wound Transformer With Off Load Tap Changing Arrangement On Hv Side In Steps Of + / - 2.50%, + / - 5% & - 7.5% , Having Cable End Boxes On Hv Sideand 800 Amp. Bus Trunking Arrangement On Lv Side Complete With All Accessories I / C First Filling Of Filtered Dehydrated Oil And Confirming To Is 2026 ( Part 1 To Part 5 ) & As Per Specification Attached Complete In All Respects As Required At Site. , Supply Of 3 Core Standered Aluminium Conduktor Xlpe ( Cross Linked Polyethylene ) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S. 7098 ( Part-Ii With Latest Amendments ) 11 Kv Grade 150Sq. Mm 3 Core , Laying Of 3 Core Standered Aluminium Conduktor Xlpe ( Cross Linked Polyethylene ) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S. 7098 ( Part-Ii With Latest Amendments ) 11 Kv Grade At A Depht Of 900 Mm Below Ground Level Over A Cushion Of 100 Mm Thick Fine River Sand All Around And Protected With Well Burnt Bricks In Sides And On The Top Put Across. Thearmouring Of Cable Shall Be Properly Connected With Earth Condutor By Clamps Etc.150Sq. Mm 3 Core , Supply Of 3 Core 240Sq.Mm. Xlpe Aluminium Conductor Cable Of 11 Kv Grage As Required. , Making Indoor Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For 3 Core 240Sq.Mm. Xlpe Aluminium Conductor Cable Of 11 Kv Grage As Required. , Making Outdoor Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For 3 Core 240 Sq.Mm. Xlpe Aluminium Conductor Cable Of 11 Kv Grage As Required. , Supply And Burying Of 40Mm Dia X 4.5 Metres Long G.I. Pipe Vertically For Earthing Having 12Mm Dia. Holes Spaced 75Mm Apart Drilled Up To 2 Metre From The Bottom Complete With Earthing Lead Of No. 6 To 8 Swg Gi Wire In G.I. Pipe Up To Appron ( And From Appron To Switch Board The Cost Of G.I. Wire And Pipe Will Be Extra ) Upto Switch Board, 30Cm Square C.I. Box With Hinged Cover Masonary Enclosure, Funnel At Top, Alternate Layers Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of Engineer-In-Charge Complete In All Respects As Per Drawing. , Supply And Burying Of 600Mm X 600 Mmx6mm G.I. Plate, Vertically For Earthing With Its Top Atleast 3 Mts. Below Ground Level Complete With 20Mm G.I.Pipe And Funnel For Watering And Two Earthing Leads Of No.8To10swg G.I.Wire In 15Mm Diag.I. Pipe Upto Switch Board ( From Apron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm. Square C.I. Frame With Hinged Cover, Masonary Housing, Alternate Layers / Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. Complete In All Respects. , Supply And Burying Of 600Mm X 600Mm X 3 Mm Copper Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I Pipe And Funnel For Watering And One Earthing Lead Ofone No. 8Swg Copper Wire In 15 Mm Dia G.I Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I Pipe And Copper Wire Will Be Extra ) 30 Cm Square C.I Frame With Hinged Cover Masonry Housingalternate Layers Of Charcoal / Coke And Salt Atleast 150Mm Thick Alround Etc. As Per Directions Of Engineer In Charge Complete In All Respects. , Supply And Laying Of 32Mm X 6Mm G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects. , Supply And Laying Of 32Mm X 6 Mm Copper Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects.. , Supply And Laying Of 25Mm X 3Mm G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects. , Supply And Fixing Of One Number 8 Swg G.I Wire In 15Mm Dia. G.I Pipe For Earthing Laid In Ground Or In Wall Duly Concealed Including The Cost Of Cement, Sand, Labour, T&P Other Material Required For Proper Completion Of The Work As Directed At Site. , Supply Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1000 Bolts Grade , 300 Sqmm3.5 Core , 185 Sqmm3.5 Core , 150 Sqmm3.5 Core , 35 Sqmm3.5 Core , 25 Sqmm3.5 Core , 16 Sqmm4 Core , 10 Sqmm4 Core , 16 Sqmm2 Core , 10 Sqmm2 Core , 6 Sqmm2 Core , Laying Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1000 Bolts Grade At A Depth Of 750Mm Below Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And Top On Surface, The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size. From 6 Sqmm 2 Core To 300 Sqmm3.5 Core , Supply Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete , 300 Sqmm3.5 Core , 185 Sqmm3.5 Core , 150 Sqmm3.5 Core , 35 Sqmm3.5 Core , 25 Sqmm3.5 Core , 16 Sqmm4 Core , 10 Sqmm4 Core , 16 Sqmm2 Core , 10 Sqmm2 Core , 6 Sqmm2 Core , Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Eic. From 6 Sqmm 2 Core To 300 Sqmm3.5 Core , Supply Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape , 300 Sqmm , 185 Sqmm , 150 Sqmm , 95 Sqmm , 70 Sqmm , 35 Sqmm , 25 Sqmm , 16 Sqmm , 10 Sqmm , 6 Sqmm , 4 Sqmm , Fixing Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape And Making Of Connections Etc. Complete In All Respects As Per Direction Of Engineer-Incharge. From 4 Sqmmto 300 Sqmm , Supply Of 7 Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 130 Mm And Base Plate 12 Mm Thik ) Having 3Mm Thikness With Single Arm Bracket ( 1 Mtr Length ) Including The Cost Of Foundation Bolts, Required T&P Complete In All Respect. , Fixing Of 7 Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 130 Mm And Base Plate 12 Mm Thik ) Having 3Mm Thikness With Single Arm Bracket ( 1 Mtr Length ) On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Complete In All Respect. , Supply Of Led Street Light Fitting Having Die Cast Aluminium Body And Diffuser With Driver Set Suitable For 45 Watt To 50 Watt. Confirming To Ip 66 And Above Protection Complete In All Respect. , Fixing Of Led Street Light Fitting Having Die Cast Aluminium Body And Diffuser With Driver Set Suitable For 45 Watt To 50 Watt. Confirming To Ip 66 And Above Protection Complete In All Respect. , Supply Of 6 Amp To 32 Amp Dp Mcb ( 10Ka ) ( C Curve ) For Poles , Fixing Of 6 Amp To 32 Amp Dp Mcb ( 10Ka ) ( C Curve ) For Poles , Supply Of Decorative 40 To 45 Watt Led Post Top Indirect Light Luminaire Having Pressure Die Cast Aluminium Body And Clear Glass With Driver Set Confirming To Ip 65 And Above Protection Complete In All Respect. , Fixing Of Decorative 40 To 45 Watt Led Post Top Indirect Light Luminaire Having Pressure Die Cast Aluminium Body And Clear Glass With Driver Set Confirming To Ip 65 And Above Protection Complete In All Respect. , Supply Offollowing Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Of Time Switch Tso 100 Series With Contractors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn Complete In All Respect.25 Amp Spn , Fixing Following Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Of Time Switch Tso 100 Series With Contractors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn Complete In All Respect.25 Amp Spn , Supply Of Bakelite Sheet 3 Mm Thick Of Suitable Size & Connector , Fixing Of Bakelite Sheet 3 Mm Thick Of Suitable Size & Connector , Supply Of M.S. Pipe ( Class B- Is : 1239 ) Pole Suitable For Fixing 70 Watt. Hpsv Post Top Including 4 Pole Cable Junction Box With 5 Amp. Rewireablefuse Fitting And 5 Amp. Switch On Laminated Cover And M.S. Box Complete With Water Tight Cover And 450X450x450mm Base Above Ground And 2X4sqmm Aluminium Wire From Cable Box To Lamp For Connection Including Painting The Pole On Primer Coats And Necessary Reducers On Thetop Of Pole For Fixing Of Post Top Lantern. 65Mm Dia 4M Long ( 3M Above Ground And 1 M Below Ground ) . , Fixing Of M.S. Pipe ( Class B- Is : 1239 ) Pole Suitable For Fixing 70 Watt. Hpsv Post Top Including 4 Pole Cable Junction Box With 5 Amp. Rewireablefuse Fitting And 5 Amp. Switch On Laminated Cover And M.S. Box Complete With Water Tight Cover Includingmasonary / Pcc ( 1:3:6 ) Work For Erecting The Pole And 450X450x450mm Base Above Ground And 2X4sqmm Aluminium Wire From Cable Box To Lamp For Connection Including Painting The Poleby An Approved Shade On Primer Coats And Necessary Reducers On Thetop Of Pole For Fixing Of Post Top Lantern.The Work Shall Be Complete As Required Up To The Satisfaction Of Engg.-In-Charge.65Mm Dia 4M Long ( 3M Above Ground And 1 M Below Ground ) . , Making Of Following Size Of Cable Chamber Made Of 230 Mm Thick Brick Work In Cement Mortar ( 1 Cement : 6 Sand ) With Pcc 100 Mm Thick Pcc Base Plastering Of Inner And Outer Surface With Cement Mortar Including Providing Of Heavy Duty C.I Cover Complete With Digging, Refilling And Removal Of Surplus Soil Complete As Required. Material Cost Will Be Paid Saperately.900 Mm X 900 Mmx 1000 Mm Deep , Supply Of Mv Danger Notice Plate Of 200 Mm X 150 Mm Made Of Mild Steel At Least 2Mmthick &Vitreousenamelledwhiteon Bothsides And Withinscription Insignalred Colouronfront Side As Required. , Supply Of Ht Danger Notice Plate 250 Mm X 200 Mm Made Of Mild Steel At Least 2Mmthick &Vitreousenamelledwhiteon Bothsides And Withinscription Insignalred Colouronfront Side As Required. , Fixing Of Mv / Ht Danger Notice Plate 250 Mm X 200 Mm Made Of Mild Steel At Least 2Mmthick &Vitreousenamelledwhiteon Bothsides And Withinscription Insignalred Colouronfront Side As Required. , Supplying Of Fire Buckets, Round Bottom Made Of G.I. Sheet 9-11 Litres Capacity Duly Painted As Per Fire Brigade Design, Supported On Hanging Bracket Chained And Locked, Initially Filled With Fine River Sand, Water As Per Directions Of Engineer-In-Charge. , Fixing Of Fire Buckets, Round Bottom Made Of G.I. Sheet 9-11 Litres Capacity Duly Painted As Per Fire Brigade Design, Supported On Hanging Bracket Chained And Locked, Initially Filled With Fine River Sand, Water As Per Directions Of Engineer-In-Charge. , Supply Of 1800 Mm X 900 Mm X 12 Mm Thick Chequered Rubber Matting Of Tested Quality , Layingof 1800 Mm X 900 Mm X 12 Mm Thick Chequered Rubber Matting Of Tested Quality , Supply Of Danger Board Fabricated From 10 Gauge Ms Sheet As Per Ie Rules , Fixing Of Danger Board Fabricated From 10 Gauge Ms Sheet As Per Ie Rules , Supply Of Shock Treatment Chart ( Prescribed Under I.E.Rules ) Duly Framed With Glass And Supported From Back With Hard Board Or Soft Board. , Fixing Of Shock Treatment Chart ( Prescribed Under I.E.Rules ) Duly Framed With Glass And Supported From Back With Hard Board Or Soft Board With Supply Of All Labour T & Pfor Proper Completion Of Work. , Supply Of Fire Extinguishers, Abc Type 4.00 Kg. Capacity ( Isi Marked Is : 15683 & Tac Approved ) Complete With Initial Charges And Wall Bracket, , Supply Of Co2 Typefire Extinguishers, 4.50 Kg. Capacity ( Isi Marked Is : 2878 & Tac Approved ) Complete With Initial Charges And Wall Bracket, , Fixing Of Fire Extinguishers, Abc Type 4.00 Kg. & Co2 Type 4.5 Kg. Capacity Complete With Initial Charges And Wall Bracket, Along With Supply Of All Labour For Proper Completion Of Work. , Supply Of Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is:7231, Parryware / Hindware / Seabird / Orient ( Coral ) With All Fittings And Fixtures Complete.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440mm With Integral Type Foot Rests , Fixing Of Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is:7231, Parryware / Hindware / Seabird / Orient ( Coral ) With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440mm With Integral Type Foot Rests , Supply Of White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, Parryware / Hindware / Seabrid / Orient ( Coral ) With All Fittings And Fixtures Complete.W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, Parryware / Hindware / Seabrid / Orient ( Coral ) With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Supply Of White Vitreous China Extended Wall Mounting Water Closet Of Size 780X370x690mm Of Approved Shape Including Providing & Fixing White Vitreous China Cistern With Dual Flush Fitting, Of Flushing Capacity 3 Litre / 6 Litre ( Adjustable To 4 Litre / 8 Litres ) , Including Seat Cover, And Cistern Fittings, Nuts, Bolts And Gasket Etc Complete. , Fixing Of White Vitreous China Extended Wall Mounting Water Closet Of Size 780X370x690mm Of Approved Shape Including Providing & Fixing White Vitreous China Cistern With Dual Flush Fitting, Of Flushing Capacity 3 Litre / 6 Litre ( Adjustable To 4 Litre / 8 Litres ) , Including Seat Cover, And Cistern Fittings, Nuts, Bolts And Gasket Etc Complete. , Supply Of White Vitreous China Wash Basin With C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps, C.P. Brass Chain With Rubber Plug, 32Mm C.P. Brass Waste Of Standerd Pattern. , A ) White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , B ) White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With Single 15 Mm C.P. Brass Pillar Taps With Elbow Operated Levers Isi Marked , Fixing Of White Vitreous China Wash Basin With C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps, C.P. Brass Chain With Rubber Plug, 32Mm C.P. Brass Waste Of Standerd Pattern Including Cutting & Making Good The Walls Wherever Required. , A ) White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , B ) White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With Single 15 Mm C.P. Brass Pillar Taps With Elbow Operated Levers Isi Marked , Supply Of P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. , Semi Rigid Pipe , 32 Mm Dia , 40 Mm Dia , Fixing Of P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. , Semi Rigid Pipe , 32 Mm Dia , 40 Mm Dia , Supply Of 600X450mm Bevelled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Fixing Of 600X450mm Bevelled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Supply Of Stainless Steel Aisi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40Mm Including Painting Of Fittings And Brackets, Kitchen Sink With Drain Board Size 510X1040 Mm Bowl Depth 250Mm , Fixing Of Stainless Steel Aisi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherrerever Required.Kitchen Sink With Drain Board Size 510X1040 Mm Bowl Depth 250Mm , Supply Of White Vitreous China Flat Back Half Stall Urinal Of Size 580*380*350Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps ( All In D.P. Brass ) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass Including Painting Of Fittings. , Range Of Three Half Stall Urinals With 10 Litre Pv.C. Automatic Flushing Cistern. , Range Of Two Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. , Range Of Single Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. , Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580*380*350Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps ( All In D.P. Brass ) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required: , Range Of Three Half Stall Urinals With 10 Litre Pv.C. Automatic Flushing Cistern. , Range Of Two Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. , Range Of Single Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. , Fixing Of Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size ) As Per Direction Of Engineer-In-Charge And Finished Smooth.Granite Stone Of Approved Shade , Supply Of Unplasticised Pvc Connection Pipe With Brass Unions , 45 Cm Length , 15 Mm Nominal Bore , Fixing Of Unplasticised Pvc Connection Pipe With Brass Unions , 45 Cm Length , 15 Mm Nominal Bore , Supply Of C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 A ) 15 Mm Nominal Bore , Fixing Of C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931V A ) 15 Mm Nominal Bore , Supply Of C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards Andweighing Not Less Than 690 Gms.A ) 15 Mm Nominal Bore , Fixing Of C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards Andweighing Not Less Than 690 Gms.A ) 15 Mm Nominal Bore , Supply Of C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is:8931A ) 15 Mm Nominal Bore , Fixing Of C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is:8931A ) 15 Mm Nominal Bore , Supply Of C.P. Brass Shower Rose With 15 Or 20Mm Inlet 150 Mm Diameter , Fixing Of C.P. Brass Shower Rose With 15 Or 20Mm Inlet150 Mm Diameter , Supply Of C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931: 150 Mm Diameter , Fixing Of C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931: 150 Mm Diameter , Supply Of Ptmt Bottle Trap For Wash Basin And Sink.Bottle Trap 31Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms , Fixing Of Ptmt Bottle Trap For Wash Basin And Sink.Bottle Trap 31Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms , Supply Of Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Fixing Of Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Supply Of Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms , Fixing Of Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour.450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms , Supply Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws , 110Mm , 90Mm , Fixing Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. , 110Mm , 90Mm , Laying Of Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 20Mm Nominal Size ) Around P.V.C Soil And Waste Pipe Including Bed Concrete As Per Standard Design ( Embedded In The Flooring / Ground ) , 100 / 75 Mm Dia , Supply Of Wall Face Unplasticised-Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A110 Mm , Fixing On Wall Face Unplasticised-Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10Mm Gap For Thermal Expansion. 110 Mm , Supply Of Wall Face Unplasticised Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592. , Bend 87.5 Degree , 110 Mm Bend , Shoe ( Plain ) 110 Mm Shoe , Fixing Of Wall Face Unplasticised Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592Type A Including Jointing With Seal Ring Conforming To Is:5382 Leaving 10Mm Gap For Thermal Expansion. , Bend 87.5 Degree , 110 Mm Bend , Shoe ( Plain ) 110 Mm Shoe , Supply Of Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. , Fixing Of The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. , Supply Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws Of Required Length. 110 Mm , Fixing Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm , Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Punning, Rounding The Edges And Making And Finishing The Outlet Complete. , Supply Of Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00M Spacing. , 20Mm Dia Nominal Outer Dia Pipes , 25Mm Dia Nominal Outer Dia Pipes , 32Mm Dia Nominal Outer Dia Pipes , Fixing Of Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. , Concealed Work Including Cutting Chases And Making Good The Walls Etc. , 20Mm Dia Nominal Outer Dia Pipes , 25Mm Dia Nominal Outer Dia Pipes , 32Mm Dia Nominal Outer Dia Pipes , Supply Of Gi Pipes Complete With Gi Fittings And Clamps. , 15Mm Dianominal Bore , 20Mm Dianominal Bore , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Fixing Of Gi Pipes Complete With Gi Fittings And Clamps, Including Cutting And Making Good Walls Etc. ( Internal Work ) . Internal Work-Exposed On Wall , 15Mm Dianominal Bore , 20Mm Dianominal Bore , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Painting Of Gi Pipes And Fittings With Synthetic Enamel Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. , 15Mm Dia Nominal Bore , 20Mm Dia Nominal Bore , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Supply Of Gi Union In Gi Pipes , 15Mm Dia Nominal Bore , 20Mm Dia Nominal Bore , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Fixing Of Gi Union In Gi Pipes Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) . , 15Mm Dia Nominal Bore , 20Mm Dia Nominal Bore , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Supply Of Gun Metal Gate Valve With Wheel Of Approved Quality. , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Fixing Of Gun Metal Gate Valve With Wheel Of Approved Quality. , 25Mm Dia Nominal Bore , 32Mm Dia Nominal Bore , 40Mm Dia Nominal Bore , 50Mm Dia Nominal Bore , 65Mm Dia Nominal Bore , Supply Of Brass Stop Cock Of Approved Quality. , B ) 20 Mm Nominal Bore , Fixing Of Brass Stop Cock Of Approved Quality. , B ) 20 Mm Nominal Bore , Supply Of Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked Indicating The Bis License No. With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Over Flow Pipes But Without Fitting And Base Support For Tank. [ Sintex, Electroplast, Star, Lotus Or Equivalent Having Valid Isi License ] . , Fixing & Placing Of Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked Indicating The Bis License No. With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Over Flow Pipes But Without Fitting And Base Support For Tank. [ Sintex, Electroplast, Star, Lotus Or Equivalent Having Valid Isi License ] . , Supply Of Glazed Stoneware Pipes Grade A100mm Dia Sw Pipe , Laying And Jointing Glazed Stoneware Pipes Grade A With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 ( 1 Cement : 1 Fine Sand ) Including Testing Of Joints Etc. Complete.100Mm Dia Sw Pipe , Laying Cement Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) All Rounds.W. Pipes Including Bed Concrete As Per Standard Design 100Mm Dia Sw Pipe , Supply Of Square-Mouth S.W. Gully Trap Grade‘A’ Complete With C.I. Grating, Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 150 X 100 Mm Size P Type , Fixing Of Square-Mouth S.W. Gully Trap Grade‘A’ Complete With C.I. Grating, Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design150 X 100 Mm Size P Type , Supply Of Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To ( Hsn Code: 3917 ) Type B ( I ) Double Socketed Pipes. , A ) 110Mm Dia P.V.C. Pipe , B ) 90Mm Dia P.V.C. Pipe , Fixing Of Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To ( Hsn Code: 3917 ) Type B Including Jointing With Seal Ring. ( I ) Double Socketed Pipes. , A ) 110Mm Dia P.V.C. Pipe , B ) 90Mm Dia P.V.C. Pipe , Supply Of Upvc Floor Trap Of Self Cleansing Designwith Cp Jalicomplete In All Respects. ( Make : Supreme / Finolex / Prince ) P-Trap Type Floor Trap 110 X 90Mm , Fixing Of Upvc Floor Trap Of Self Cleansing Designwith Cp Jalicomplete In All Respects. ( Make : Supreme / Finolex / Prince ) P-Trap Type Floor Trap 110 X 90Mm , Supply Of Clean Out Plug ( Astral ) , Fixing Of Clean Out Plug ( Astral ) , Supply Ofterminal Guard. , A ) 110Mm , B ) 90Mm , Fixing Of Terminal Guard. , A ) 110Mm , B ) 90Mm , Supply Of Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes. , 110Mm Bend , 90 Mm Bend , 110Mm Coupler , 90Mmcoupler , 110X110x110 Mm Single Tee With Door , 90X90x90 Mm Single Tee With Door , Fixing Of Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. , 110Mm Bend , 90 Mm Bend , 110Mm Coupler , 90Mmcoupler , 110X110x110 Mm Single Tee With Door , 90X90x90 Mm Single Tee With Door , Supply Of 1.50 Sqmm Frlsh Pvc Insulated Single Core Copper Conductor Cable , Supply Of 2.50 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable , Supply Of 4.00 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable , Supply Of 6.00 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable , Supply Of 10 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable , Supply Of 16 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable , Supply Of 25 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable , Supply Of Hexagonal / Round Gp Fan Box Of Approved Make Made Up Of 1 Mm Thick Isi Marked Gp Sheet Spot Welded Four To Eight Holes Of 25.4 Mm For Pipe Entry Of The Box Duly Screewed Fitted With 300 Mm Round Zink Coated Ms Bar X 12 Mm. , Supply Of Ceiling Fan With Fan Motor Of Ac Permanent Insulation, Capacitor Rating Conforming To Bee 5 Star. The Ratrd Voltage220 / 240 Volts, 50 Hz, Single Phase, Ac The Fan Assemble Should Consists Of Down Road Blades, Shackle Canopies With Double Ball Bearing System – 1200 Mm Sweep , Supply Of Electronic Fan Regulator ( Modular ) 120- 280 V Isi Marked , Supply Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 2X 22 Watt Suitable For 2X22 Watt Polycarbonate Tube Light Including Tube Etc Suitable For Both Surface. , Supply Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 1X 22 Watt Suitable For 1X22 Watt Polycarbonate Tube Light Including Tube Etc Suitable For Both Surface. , Supply Of Recess / Surface Mounting Round 10 To 15 Watt, Cut Out 125 Mm, Height Min 40 Mm, Led Downlighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflector And Driver Set, Suitable For 24 Hr Continuousoperation , Supply Of Single Led Light Wall Bracket On Matching Mdfeg Board Base , Water Tight Oblong 10 Watt Led Bulkhead Luminery With Driver Set Conforming To Ip 65 And Above Protection Complete. , Supply Of Surface / Flush Mounting Distribution Boards With Additional Metal Door Without Mcb Complete. ( Cat A ) , 4 Way Tpn , 6 Way Tpn , 8 Way Tpn , Supply Of 6 Amp To 32 Amp ( 10 Ka ) Sp Mcb ( Cat A ) , Supply Of Following Mcbs , 40 Amp. Fp Mcb ( Cat A ) , 63 Amp. Fp Mcb ( Cat A ) , 40 Amp. Tp Mcb ( Cat A ) , 63 Amp. Tp Mcb ( Cat A ) , Supply Of Surface / Flush Mounting V Tpn Distribution Boards With Additional Metal Door Without Mcb Complete. 4 Way V Tpn , Supply Of Following Mccbs , 63 Amp. Fp Mccb ( Cat A ) , 100 Amp. Fp Mccb ( Cat A ) , 125 Amp. Fp Mccb ( Cat A ) , 160 Amp. Fp Mccb ( Cat A ) , Supply Of Power Plug With 15 A / 250 V Flush Type Switch And 5 Pin 15 A / 250 V Flush Type Universal Socket In Suitable Ms Box 175Mmx100mmx50mm Size ( Modular ) , Supply Of Single Pole Mcbs Blanking Plate Complete , Supply Of Gi Plate For Earthing Size 600 Mm X 600Mm X 6 Mm , Supply Of Gi Pipe 20 Mm Dia , Supply Of Gi Wire 8 To 10 Swg , Supply Of Ci Frame ( 30 Sqcm ) With Hinged Cover , Supply Of Gi Strip For Earthing Purpose 25 Mmx 3 Mm , Supply Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheeted Cable 1000 Volts , 95 Sqmm 3.5 Core , 70 Sqmm 3.5 Core , 50 Sqmm 3.5 Core , 35 Sqmm 3.5 Core , 25 Sqmm 3.5 Core , 10 Sqmm 4 Core , Supply Of Brass Nickle Plated Compression Gland For Pvc Insulated And Armoured Served Sheeted Underground Cable Including Rubber Ring , 95 Sqmm 3.5 Core , 70 Sqmm 3.5 Core , 50 Sqmm 3.5 Core , 35 Sqmm 3.5 Core , 25 Sqmm 3.5 Core , 10 Sqmm 4 Core , Supply Of Palm / Pin Type Copper Tin Plated Cable Sockets ( Lugs ) To The Cable Leads, Insulating With Tape , 95 Sqmm , 70 Sqmm , 50 Sqmm , 35 Sqmm , 25 Sqmm , 16 Sqmm , 10 Sqmm , 6 Sqmm , Supply Of Gi Box Alonwith Modular Base And Cover Plate For Modular Switches In Recess1 Or 2 Module ( 75 Mmx75 Mm ) , Supply Of Telephone Socket Outlet ( Modular ) , Supply Of Tv Antenna Socket Outlet ( Modular ) , Supply Of Bell Push ( Modular ) , Supply Of Call Bell / Buzzer Suitable Single Phase 230 V , Supply Of Telephone Cable Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured , 2 Pair , 10 Pair , 20 Pair , Supply Of Co-Axial Tv Cable Rg-6 Grade 0.7 Mm Solid Copper Conductor Pe Insulated Sheeted With Fine Tinned Copper Braid And Protected With Pvc Sheet , Supply Of 10 Pair Junction Boxes For Floors And Building With Krone Connectors , Supply Of 20 Pair Junction Boxes For Floors And Building With Krone Connectors , Supply Of 50 Pair Junction Boxes For Floors And Building With Krone Connectors , Supply Of Exhaust Fan Of Ac 230 / 250 V, 50 Hz Including Nuts & Bolts, Mounting Frame And Other Accessories.300 Mm Sweep , Supply Of Energy Meter ( 3 Phase ) And Other Accessories. , Supply Of Wall Fanof Ac 230 / 250 V, 50 Hz Including Nuts & Bolts, Mounting Frame And Other Accessories. 450 Mm Sweep , Supply Of Exhaust Fan Of Ac 230 / 250 V, 50 Hz Including Nuts & Bolts, Mounting Frame And Other Accessories.450 Mm Sweep , Supply Of Weired Decorative Mirror Light Suitable 9 Watt Led With Lamp Complete , Supply Of Factory Weired Integral Led Flood Light Luminaries With Die Cast Aluminium Housing Built With Driver Set Suitable For 40 To 50 Watt Confoming To Ip 65 / 66 Protection Complete. , Supply Of Swiches ( Modular ) 5 Amp , Supply Of Sockets ( Modular ) 5 Amp , Supply Of Pvc Conduit Pipe 25 Mm Dia , Supply Of Round Sheet , Supply Of Ceiling Rose , Supply Of Holder For Bulbs , Fixing Of Main Lt Panel , Fixing Of Main Em Panel , Fixing Of Sub Panel , Fixing Of Sub Em Panel , Fixing Of Capacitor Panel 150Kvar , Fixing Of Feeder Piller , Fixing Of Street Feeder Piller , Supply Of Coarse Sand , Supply Of Cement50 Kg , Supply Of Brick M150 , Supply Of Stone Grit 20 Mm , Supply Of Stone Ballast 40 Mm , Supply Of Tor Steel 8 Mm Dia , Supply Of Tor Steel 10 Mm Dia , Supply Of Tor Steel 12 Mm Dia , Supply Of Tor Steel 16 Mm Dia , Supply Of Tor Steel 20 Mm Dia , Supply Of Tor Steel 25 Mm Dia , Supply Of Ms Fabrication For Door Window And Ventilator , Supply Of Water Proofing Chemical Cico Tapecrete P151 , Supply Of Y Shaped Angle Iron Post 40X40x6 , Supply Of Kota Stone 22 Mm Thick , Supply Of Vitriried Floor Tile 8 To 10 Mm Thick In 600X600 Mm Size , Supply Of Wall Tile Glazed / Ceramic Floor Tiles , Supply Of Ss Railing 304 Grade , Supply Of Ms Collapsible Channel , Supply Of Rolling Shutter With Ball Bearing , Supply Of Granite , Supply Of Cinder , Supply Ofchequred Tile 300X300 Mm Size , Supply Of Ms Gate Made Of Ms Hollow Sections , Supply Of Interlocking Pavers 80 Mm M30 Mpa , Labour Charge For Construction Of Rcc Over Head Tankas Per Design And Drawing &Directions Of Engineer-In-Charge.

Key Value

Document Fees
INR 5900 /-
EMD
INR 500000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Invitation of Rates for Supply of Materials & Piece rated works (Labour Rates)at Balance work of Asra Yojana Atsu Auraiya 192 Nos DUs (NIT No 465/E-NIVIDA/82 dt. 29-05-2023)
Sl. No. Item Description
1Earth work in excavation in trenches for foundation pipes, cable etc in ordinary sol (Loam clay or sand) inlcuding lift upto 1.5 Mt. lead upto 30mt. and dressing of sides and rammings of bottom and disposal of surplus excavated earth as directed by the engineer.
2upto 1.50 m to 3.00 m deep
3upto 3.00 m to 4.50 m deep
4upto 4.50 m to 6.00 m deep
5Filling of carted earth
6Laying in position cement concrete of specifiedgrade including the cost of centring and shuttering-All work upto plinth level.
7in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size)
8in cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size )
9Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer"s standard dilution)
10R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also excluding supply of all materials, and including labour and tools and plants etc, required for proper completion of the works.
11Ground Floor
12First Floor
13Second Floor
14As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete).
15Ground Floor
16First Floor
17Second Floor
18As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)
19Ground Floor
20First Floor
21Second Floor
22As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete)
23As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.
24Ground Floor
25First Floor
26Second Floor
27M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth includinglabour and T & P etc & excluding supply of all materials, required for proper completion of the work.
28M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth includinglabour and T & P etc & excluding supply of all materials, required for proper completion of the work.
29Laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
30Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
31Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level (up to two storeys) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand)
32Ground Floor
33First Floor
34Second Floor
35Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
36Ground Floor
37First Floor
38Second Floor
39Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and excluding supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
40Ground Floor
41First floor
42Second Floor
4315 mm cement plaster on rough side of single or half brick wall of mix : 1:3 (1 cement: 3 coarse sand)
4415 mm cement plaster in single coat on rough side of single or halfbrick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand .
45Ground Floor
46First Floor
47Second Floor
4812mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand.
49Ground Floor
50First Floor
51Second Floor
52Engraving lines in the plaster of outer face well vertically & horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labpur, & T & P etc. required for proper completion of the work.
53Ground Floor
54First Floor
55Second Floor
56Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
57Laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete including supply of all labour, T & P etc. excluding the cost of materials required for proper completion the work.
58Ground Floor
59First Floor
60Second Floor
61Laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete including supply of all labour, T & P etc. excluding the cost of materials required for proper completion the work.
62Ground Floor
63First Floor
64Second Floor
65Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
66Ground Floor
67First Floor
68Second Floor
69Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
70Ground Floor
71First Floor
72Second Floor
73Fixing of 6 mm thick approved China white / coloured glazed tiles in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished and jointed with white cement slurry and pigment and polishing complete includinglabour and tool sand plants & excluding supply of all materials,etc. required for proper completion of the work.
74Ground Floor
75First Floor
76Second Floor
7725 mm thick cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12.5mm nominal size and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (excluding cost of glass strips)
78Supply of flush doors commercial qualityconforming to I.S.2202 Part I (1983) including fixing of wooden cleats and stoppers
7935 mm thick
80(a) Single leaf
81(b) Double leaf
8232 mm thick
83(a) Single leaf
84Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)
85Fixing of flush / pvc doors including fixing of wooden/pvc cleats and stoppers and includingfixing and adjustment of hinges, bolts,locks, handle, springs. Fittings to be supplied departmentally.
86Supply of factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick plain PVC door shutters
87Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
88M.S. Hold fast for doors and windows
89M.S. Grill
90Z-Section winodws (Openable)
91M.S. angle door chaukhat 40*40*5
92Fixing of door, windows / ventilators chaukhats in position.
93(a) Door chaukhats
94(b) Window chaukhats
95(c) Ventilator chaukhats
96Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Inside walls)
97Ground Floor
98First Floor
99Second Floor
100Finishing walls with two coat of Acrylic Smooth exterior paint of best quality including supply of all materials labour and tool sand plants etc. required for proper completion of the work.
101Ground Floor
102First Floor
103Second Floor
104Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat)
105Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat)
106Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth excludingcost of all materials. (Ceiling)
107Providing & Applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
108Supply of 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
109Supply of Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
110Supply of stainless steel towerbolts (barrel type) with necessary screws etc. complete
111(a) 300mm x 10mm
112(b) 250 mm x 10mm
113Supply of bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm
114Providing and laying cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming toIS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
115Painting or Vanishing two coat on iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior ready mixed paint of clear synthetic varnish including supply of all materials, labour, T & P etc. required for proper completion the work. Paint to be used should confirm to the I.S.I. No. 103 1950.
116Same as item above but on new wood surface.
117Fixing panes of glass with equal or equivalent I.S.I. marked quality putty, brads and springs including supply of all materials, labour etc. complete. 3.80 to 4.70 mm thick
118Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing & excluding supply of all materials complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement.
119Filling of light cinder filling under floor of toilets & other sunken roofs.
120Labour charges for wiring points for light with 1.5 sqmm.FRLSH PVC insulated single core Copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.
121Same as item No. (1) but for two way light Points.
122Same as item No. (1) but for fanandlight duty exhaust fan.
123Same as item No.(1) but for5amp plug point with piano type switch and socket etc.
124Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.
125Addition for light / fan points with modular type switchin place of piono type switch.
126Addition for plugpointswith modular type switchin place of piono type switch.
127Addition for Exhaust fanpointswith modular type switchin place of piono type switch.
128Wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.
129Wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
130Wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
131Wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 32mm dia PVC conduitalong with two numbers 6 sqmm FRLSH PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects.
132Wiring of submain 4 number 16 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 40mm dia PVC conduitalong with two numbers 10 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
133Wiring of submain 4 number 25 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 50mm dia PVC conduitalong with two numbers 16 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
134Fixing and concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone)
135Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects.
136Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
137Fixing of hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
138Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep
139Fixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
140Fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)
141Fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)
142Fixing of recess/Surface mounting round 10 to 15 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respect.(CAT: AAA)
143Fixing of single LED light wall bracket on matching M.D.F.E.G board base etc. complete in all respect.(CAT: AAA)
144Fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA)
145Fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.(CAT A)
1464 Way TPN
1476 Way TPN
1488 Way TPN
149Fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A)
150Fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)
15140 Amp. FP MCB(CAT: A)
15263 Amp. FP MCB(CAT: A)
153Fixing of surface/flush mounting V TPN distribution boards with additional metal door withot MCB complete in all respects.(CAT A) 4 Way V TPN
154Fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)
155100 Amp. FP MCCB(CAT: A)
156125 Amp. FP MCCB(CAT: A)
157160 Amp. FP MCCB(CAT: A)
158Fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)
15940 Amp. TP MCB(CAT: A)
16063 Amp. TP MCB(CAT: A)
161Fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
162Fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work.
163Fixing of Single Pole MCBS Blanking Plate complete in all respects. (CAT: A)
164Fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. FP MCCB
165Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in
166Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.
167Fixing of two number 8 SWG G.I. wire in 15mm dia GI pipe for earthing purpose as required complete in all respects.
168Laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the
16995 sqmm3.5 core
17070 sqmm3.5 core
17150 sqmm3.5 core
17235 sqmm3.5 core
17325 sqmm3.5 core
17410 sqmm4 core
175Fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
17695 sqmm3.5 core
17770 sqmm3.5 core
17850 sqmm3.5 core
17935 sqmm3.5 core
18025 sqmm3.5 core
18110 sqmm4 core
182Fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
18395 sqmm
18470 sqmm
18550 sqmm
18635 sqmm
18725 sqmm
18816 sqmm
18910 sqmm
1906 sqmm
191Fixing ofMODULAR BOXES, BASE & COVER PLATE
192Fixing of following size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm)
193FIXING OFMODULAR TYPE SWITCH / SOCKET :-
194Fixing of following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required.
195Telephone socket outlet
196TV Antenna socket outlet
197Bell Push
198Fixing of call bell/ buzzer suitable single phase, 230 V etc as required.
199Laying oftelephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair
200Drawing of co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.
201Drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.
20220 Pair
20310 Pair
204Fixing of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
205Fixing of 20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
206Fixing of 50 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
207Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm
208Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep.
209Fixing of energy Meter and other accessories including connections etc. complete as required 3 Phase Meter
210Erection of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required450mm sweep.
211Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required450mm sweep. (At Labs)
212Fixing of wired decorative mirror light on suiatable for 9 Watt LED with lamp complete in all respect.
213Fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt Conforming to IP 65/66 protection complete in all respect. (CAT-AAA)
214Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)Second layer of slurry of cement@ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm.This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
215Fixing of stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, excluding the cost of materials on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
216Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas thatccommodates multi directional seismic movement without stress to it"s components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions.The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063)Floor Joint of 100 mm gap
217Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement
218and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including verticalisplacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.)Roof Joint of 100 mm gap
219Providing and fixing of expansion joint systemelated with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimalexposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 100 mm gap
220Fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 200 mm wide.
221Granite stone slab 18 mm thick mirror polished quarter rounded with anti skid lines in treads of staircase full length flooring over 20 mm (average) thick base laid over and jointed with cement slurry mixed with pigment to match the shade of including rubbing & polishing complete with base of cement mottar 1:4 (1 cement : 4 coarse snad) etc. complete excluding the cost of materials.
222Ground Floor
223First Floor
224Second Floor
225Fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,ocking arrangement, stoppers, handles, including applying a priming coat of approved steel primer & excluding the cost of materials.
226Fixing Rolling Shutters of approved make of 80 × 125 mm (3" × 18 gauge) cold rolled ML Lath inter lockedthrough their eintire length and joined together at the end by locks and mountedon specially designed pipe shaft with brackets and wall bearing & excluding the cost of materials.
22740mm thick cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (excluding cost of glass strips)
228Fixing glass strips in joints of floors and skirting or dado add the item of laying floors flush with floor level including supply of all materials, labour, T & P etc. required for proper completion the work. (a) 37 mm wide and 3.15 mm thick
22952 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer"s specifications.but excluding the cost of materials etc. complete.
230Supply of 80mm thick Rubber Moulded cement concrete interlocking pavers block. The compressive strength of concrete pavers blocks shall not be less than 30MPa & 4.5Kg/no.
231Providing and laying of 80mm thick Rubber Moulded cement concrete interlocking pavers block. The compressive strength of concrete pavers blocks shall not be less than 30MPa & 4.5Kg/no.
232Fixing of Angle Iron Frame 40x40x6 mm in position.
233Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, G.I. barbed wire, earth work and concrete to be paid for separately)
234Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
235Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm.
236Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size
237Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only
238P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia.
239Fixing of G.I. Pipe(80 MM DIA) as per design & drawing As per drection of EIC
240Fabrication of angle iron door chaukhat of 40*40*6 mm
241Supply of concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre.
242Fixing of concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of Materialsshall be paid separately)
243Supply of M.S. foot rest as per standard design with 20x20mm sq bars.
244Fixing of M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
245Supply ofC.I. tee at the inlet and outlet of septic tank.
246Fixing C.I. tee at the inlet and outlet of septic tank.
247Supply of 75mm dia vent pipes.
248Fixing of 75mm dia vent pipes.
249Supply of 75mm dia cast iron terminal guard.
250Fixing of 75mm dia cast iron terminal guard.
251Supply ofprecast RCC manhole cover and frame of required shape and approved quality.
252M.D. -10- Circular shape 500mm internal diameter
253M.D. -2.5- Circular shape 450mm internal diameter
254Fixing in position precast RCC manhole cover and frame of required shape and approved quality.
255M.D. -10- Circular shape 500mm internal diameter
256M.D. -2.5- Circular shape 450mm internal diameter
257Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
258up to 1.50 m depth
259Pipes 80 mm to 300 mmdiameter
2601.50 m to 3.00 m depth
261Pipes 80 mm to 300 mmdiameter
262Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
263Depth not exceeding 1.5 meter
264Depth 1.5 to3.00meter
265Supply of Non pressureNP 2 class (light duty) RCC pipe with collars etc. complete.
266150 mm.dia. RCCPipes
267250 mm.dia. RCCPipes
268100 mm dia RCC Pipes
269Laying of NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
270150 mm.dia. RCCPipes
271250 mm.dia. RCCPipes
272100 mm dia RCC Pipes
273Laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
274150 mm.dia. RCCPipes
275250 mm.dia. RCCPipes
276100 mm dia RCC Pipes
277Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
278Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
279Extra for depth for manholes:
280Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
281Extra for depth for manholes:
282Supply of orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing.
283Fixing of orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
284Supply of double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329 100mm dia Ductile iron double flanged
285Fixing & laying double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329 100mm dia Ductile iron double flanged
286Supply of CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete.
287Fixing of CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete.
288Supply of push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipes
289Fixing of push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipes
290Supply ofC.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 100mm diameter
291Fixing of C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 100mm diameter
292Supply of C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately. a) 50mm dia
293Fixing of C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paidsaperately 50mm dia
294Supply of G.I. pipes (medium) complete with G.I. fittings
29580mm nominal bore.
29665mm nominal bore.
29750mm nominal bore.
29840mm nominal bore.
29932mm nominal bore.
30025mm nominal bore.
30120mm nominal bore.
30215mm nominal bore.
303Laying, jointing, testing & commisioning ofG.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)
30480mm nominal bore.
30565mm nominal bore.
30650mm nominal bore.
30740mm nominal bore.
30832mm nominal bore.
30925mm nominal bore.
31020mm nominal bore.
31115mm nominal bore.
312Supplying of specials for pressure pipe.
313Fixing of specials for pressure pipe.
314Supply ofgate valve (with cap complete with bolts, nuts, rubber insertion etc.
31580mm nominal bore.
31665mm nominal bore.
31750mm nominal bore.
31840mm nominal bore.
31932mm nominal bore.
32025mm nominal bore.
321Fixing of gate valve (with cap complete with bolts, nuts, rubber insertion etc.
32280mm nominal bore.
32365mm nominal bore.
32450mm nominal bore.
32540mm nominal bore.
32632mm nominal bore.
32725mm nominal bore.
328Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
329Constructing brick masonry chamber 600 x 600x750mm insidewithF.P.S. brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slabwith 1 : 2 : 4 mix (1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size); necessary excavation,foundationconcrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plasteringwithcement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign
330Supply ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. 4 way
331Fixing, Installation, Testing & Commissioning ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. 4 way
332Supply of Sluice Valve complete with flanges, gasket, nut bolts 150 mm
333Fixing, Installation, Testing & Commissioning of Sluice Valve complete with flanges, gasket, nut bolts 150 mm
334Supply of NRV complete with flanges, gasket and nut bolts. 150 mm
335Fixing, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. 150 mm
336Supply of MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required (For Riser)
337150 mm dia
338100mm dia
339Fixing of MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser)
340150 mm dia
341100mm dia
342Supply of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories.
343Fixing, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories.
344Supply of Fire Man Axe.
345Fixing of Fire Man Axe.
346Supply of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
347Fixing, Installation, Testing & Commissioning of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
348Supply of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
349Fixing, Installation, Testing & Commissioning of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
350Supply of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
351Fixing, Installation, Testing & Commissioning of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
352Supply of Butterfly Valve complete with flanges, gasket, nut bolts 100 mm
353Fixing, Installation, Testing & Commissioning of Butterfly Valve complete with flanges, gasket, nut bolts 100 mm
354Supply of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
355Fixing, Installation, Testing & Commissioning of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
356Supply of Air cushion Tank (2000x1000)mm.
357Fixing, Installation, Testing & Commissioning of Air cushion Tank (2000x1000)mm.
358Supply of Air Release Valve.
359Fixing, Installation, Testing & Commissioning of Air Release Valve.
360Supply of NRV complete with flanges, gasket and nut bolts. 100 mm
361Fixing, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts.
362Supply of Pressure Gauge with gauge cock
363Fixing, Installation, Testing & Commissioning of Pressure Gauge with gauge cock
364Supply of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class "B" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it"s rated discharge at 65% of rated head. © Common bed plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minute Head : 35 meter
365Installation, testing and commisioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class "B" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it"s rated discharge at 65% of rated head. © Common bed plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minute Head : 35 meter
366(a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.
367Fixing & placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
368Supply of halon free portable fire Extinguishers as described below:
3694.5 kg carbon dioxide extinguisher, IS marked, with high pressure discharge tube, horn, control valve, CCE approved cylinder
3706 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers
3719 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers
372Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 .
373Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285
374Fixing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:
375Supply of Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size for fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete.
376Fixing of Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
377Supply ofCI cover with frame LIGHT WEIGHT complete as perdesign size 600x600 mm
378Supply ofCI cover with frame LIGHT WEIGHT complete as perdesign size 900x900 mm
379Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.Drilling of 250 mm dia bore hole manually.
380Supply of unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia
381Assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia
382Supply of stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
383Supply of gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
384Supply of coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
385Filling, spreading & leveling coarse sand, gravels & stone boulders of size range 1.5 mm to 20 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
386Transportation Charges of drilling equipment including assembly and other material as required.
387Drilling of 675 mm. dia by rotary machine
388Supply of 350 mm. dia housing pipe (8 mm. thick)
389Laying of 350 mm. dia housing pipe (8 mm. thick)
390Supply of 200 mm. dia blind pipe (8 mm. thick)
391Laying of 200 mm. dia blind pipe (8 mm. thick)
392Supply of 200 mm. dia slotted pipe (8 mm. thick)
393Laying of 200 mm. dia slotted pipe (8 mm. thick)
394Supply of 350 mm. dia Socket
395Fixing of 350 mm. dia Socket
396Supply of 200 mm. dia Socket
397Fixing of 200 mm. dia Socket
398Supply of 200 mm. dia Bail plug
399Fixing of 200 mm. dia Bail plug
400Supply of 350 mm. dia well cap
401Fixing of 350 mm. dia well cap
402Supply of 350x200 mm. dia reducer.
403Fixing of 350x200 mm. dia reducer.
404Supply of 350 mm. dia housing clamp
405Fixing of 350 mm. dia housing clamp
406Supply of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.
407Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.
408Development by air compressor including Transportation.
409Development by O.P. Unit including Transportation.
410Supply of 7.5 HP KSB make submersible pump set model BPD 302/4+UAMI 150/6/22-203 (S/D) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition 7.5 HP 6 stage pipe.A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm.B - Total Head of pump set 45 m.
411Supply of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.
412Fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.
413Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set.
414Supply of 80mm dia M.S. column pipe of class "C" both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.
415Lowering of 80mm dia M.S. column pipe of class "C" both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.
416Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.
417Lowering of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.
418Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make.
419Fixing ofC.I. double flanged reflex valve
420Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.
421Supply of 100 mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.
422Supply of 150mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.
423Fixing of 80/100/150 mm dia C.I. double flanged ISI mark sluice valve with hand wheel
424Supply of C.I. double flanged bend of 80mm dia
425Fixing of C.I. double flanged bend of 80mm dia i/c cost of labour.
426Supply of 80mm dia C.I. tee heavy quality i/c cost of material.
427Fixing of 80mm dia C.I. tee heavy quality
428Supply of Guru/Fibing or equivalent make pressure gauge.
429Fixing of pressure gauge.
430Erection & commissioning of pumping plants complete along with electric wiring.
431Supply of steel wire rope of 1/2" size
432Fixing of steel wire rope of 1/2" size
433S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing.
434S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site.
435S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade16 sqmm x 4 core
436Fixing of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc.16 sqmm x 4 core
437Supply of 500 KVA. 11/0.433 KV, 3Phase, 50Hz, Dyn 11, Oil type, ( UPPCL approved make) copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% & - 7.5% , having cable end boxes on HV sideand 800 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.
438Installation, testing and commissioning of 500 KVA. 11/0.433 KV, 3Phase, 50Hz, Dyn 11, Oil type, ( UPPCL approved make) copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% & - 7.5% , having cable end boxes on HV sideand 800 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.
439Supply of 3 core standered aluminium conduktor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098(Part-II with latest amendments) 11 KV grade 150sq. mm 3 Core
440Laying of 3 core standered aluminium conduktor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098(Part-II with latest amendments) 11 KV grade at a depht of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks in sides and on the top put across. Thearmouring of cable shall be properly connected with earth condutor by clamps etc.150sq. mm 3 Core
441Supply of 3 core 240Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.
442Making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 240Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.
443Making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 240 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.
444Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
445Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
446Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead ofone no. 8SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects.
447Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
448Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects..
449Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
450Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.
451Supply of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade
452300 sqmm3.5 core
453185 sqmm3.5 core
454150 sqmm3.5 core
45535 sqmm3.5 core
45625 sqmm3.5 core
45716 sqmm4 core
45810 sqmm4 core
45916 sqmm2 core
46010 sqmm2 core
4616 sqmm2 core
462Laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. From 6 sqmm 2 core to 300 sqmm3.5 core
463Supply of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete
464300 sqmm3.5 core
465185 sqmm3.5 core
466150 sqmm3.5 core
46735 sqmm3.5 core
46825 sqmm3.5 core
46916 sqmm4 core
47010 sqmm4 core
47116 sqmm2 core
47210 sqmm2 core
4736 sqmm2 core
474Fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of EIC. From 6 sqmm 2 core to 300 sqmm3.5 core
475Supply of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape
476300 sqmm
477185 sqmm
478150 sqmm
47995 sqmm
48070 sqmm
48135 sqmm
48225 sqmm
48316 sqmm
48410 sqmm
4856 sqmm
4864 sqmm
487Fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. From 4 sqmmto 300 sqmm
488Supply of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) including the cost of foundation bolts, Required T&P complete in all respect.
489Fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.
490Supply of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.
491Fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.
492Supply of 6 Amp to 32 Amp DP MCB (10KA) (C curve) for poles
493Fixing of 6 Amp to 32 Amp DP MCB (10KA) (C curve) for poles
494Supply of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect.
495Fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect.
496Supply offollowing capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect.25 Amp SPN
497Fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect.25 Amp SPN
498Supply of Bakelite sheet 3 mm thick of suitable size & connector
499Fixing of Bakelite sheet 3 mm thick of suitable size & connector
500Supply of M.S. pipe (Class "B"- IS : 1239) pole suitable for fixing 70 watt. HPSV post top including 4 pole cable junction box with 5 Amp. rewireablefuse fitting and 5 Amp. switch on laminated cover and M.S. box complete with water tight cover and 450x450x450mm base above ground and 2x4sqmm Aluminium wire from cable box to lamp for connection including painting the pole on primer coats and necessary reducers on thetop of pole for fixing of post top lantern. 65mm dia 4m long (3m above ground and 1 m below ground).
501Fixing of M.S. pipe (Class "B"- IS : 1239) pole suitable for fixing 70 watt. HPSV post top including 4 pole cable junction box with 5 Amp. rewireablefuse fitting and 5 Amp. switch on laminated cover and M.S. box complete with water tight cover includingMasonary/PCC (1:3:6) work for erecting the pole and 450x450x450mm base above ground and 2x4sqmm Aluminium wire from cable box to lamp for connection including painting the poleby an approved shade on primer coats and necessary reducers on thetop of pole for fixing of post top lantern.The work shall be complete as required up to the satisfaction of Engg.-in-Charge.65mm dia 4m long (3m above ground and 1 m below ground).
502Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. material cost will be paid saperately.900 mm x 900 mmx 1000 mm deep
503Supply of MV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
504Supply of HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
505Fixing of MV / HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
506Supplying of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
507Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
508Supply of 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality
509Layingof 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality
510Supply of danger board fabricated from 10 gauge MS sheet as per IE Rules
511Fixing of danger board fabricated from 10 gauge MS sheet as per IE Rules
512Supply of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board.
513Fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all labour T & Pfor proper completion of work.
514Supply of fire extinguishers, ABC Type 4.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket,
515Supply of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket,
516Fixing of fire extinguishers, ABC Type 4.00 kg. & CO2 type 4.5 kg. capacity complete with initial charges and wall bracket, along with supply of all labour for proper completion of work.
517Supply of water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/ Orient (Coral) with all fittings and fixtures complete.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
518Fixing of water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/ Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
519Supply of white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete.W.C. pan with ISI marked black solid plastic seat and lid
520Fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid
521Supply of white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
522Fixing of white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
523Supply of white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern.
524a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
525b)White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISi marked
526Fixing of white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.
527a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
528b)White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISi marked
529Supply of P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
530Semi rigid pipe
53132 mm dia
53240 mm dia
533Fixing of P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
534Semi rigid pipe
53532 mm dia
53640 mm dia
537Supply of 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
538Fixing of 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
539Supply of Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
540Fixing of Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
541Supply of white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings.
542Range of Three half stall urinals with 10 litre PV.C. automatic flushing cistern.
543Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern.
544Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern.
545Fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:
546Range of Three half stall urinals with 10 litre PV.C. automatic flushing cistern.
547Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern.
548Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern.
549Fixing of stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
550Supply of unplasticised PVC connection pipe with brass unions
55145 cm length
55215 mm nominal bore
553Fixing of unplasticised PVC connection pipe with brass unions
55445 cm length
55515 mm nominal bore
556Supply of C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore
557Fixing of C.P. brass bib cock of approved quality conforming to IS:8931V a) 15 mm nominal bore
558Supply of C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.a) 15 mm nominal bore
559Fixing of C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.a) 15 mm nominal bore
560Supply of C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore
561Fixing of C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore
562Supply of C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter
563Fixing of C.P. brass shower rose with 15 or 20mm inlet150 mm diameter
564Supply of C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 150 mm diameter
565Fixing of C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 150 mm diameter
566Supply of PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
567Fixing of PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
568Supply of PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
569Fixing of PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
570Supply of PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
571Fixing of PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
572Supply of unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws
573110mm
57490mm
575Fixing of unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
576110mm
57790mm
578Laying of cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
579100 /75 mm dia
580Supply of wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A110 mm
581Fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm
582Supply of wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592.
583Bend 87.5 degree
584110 mm Bend
585Shoe (Plain) 110 mm Shoe
586Fixing of wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
587Bend 87.5 degree
588110 mm Bend
589Shoe (Plain) 110 mm Shoe
590Supply of inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
591Fixing of the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
592Supply of unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length. 110 mm
593Fixing of unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
594Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
595Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.
59620mm dia nominal outer dia pipes
59725mm dia nominal outer dia pipes
59832mm dia nominal outer dia pipes
599Fixing of Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
600Concealed work including cutting chases and making good the walls etc.
60120mm dia nominal outer dia pipes
60225mm dia nominal outer dia pipes
60332mm dia nominal outer dia pipes
604Supply of GI pipes complete with GI fittings and clamps.
60515mm dianominal bore
60620mm dianominal bore
60725mm dia nominal bore
60832mm dia nominal bore
60940mm dia nominal bore
61050mm dia nominal bore
61165mm dia nominal bore
612Fixing of GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). Internal work-Exposed on wall
61315mm dianominal bore
61420mm dianominal bore
61525mm dia nominal bore
61632mm dia nominal bore
61740mm dia nominal bore
61850mm dia nominal bore
61965mm dia nominal bore
620Painting of GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work.
62115mm dia nominal bore
62220mm dia nominal bore
62325mm dia nominal bore
62432mm dia nominal bore
62540mm dia nominal bore
62650mm dia nominal bore
62765mm dia nominal bore
628Supply of GI Union in GI pipes
62915mm dia nominal bore
63020mm dia nominal bore
63125mm dia nominal bore
63232mm dia nominal bore
63340mm dia nominal bore
63450mm dia nominal bore
63565mm dia nominal bore
636Fixing of GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).
63715mm dia nominal bore
63820mm dia nominal bore
63925mm dia nominal bore
64032mm dia nominal bore
64140mm dia nominal bore
64250mm dia nominal bore
64365mm dia nominal bore
644Supply of gun metal gate valve with wheel of approved quality.
64525mm dia nominal bore
64632mm dia nominal bore
64740mm dia nominal bore
64850mm dia nominal bore
64965mm dia nominal bore
650Fixing of gun metal gate valve with wheel of approved quality.
65125mm dia nominal bore
65232mm dia nominal bore
65340mm dia nominal bore
65450mm dia nominal bore
65565mm dia nominal bore
656Supply of brass stop cock of approved quality.
657b) 20 mm nominal bore
658Fixing of brass stop cock of approved quality.
659b) 20 mm nominal bore
660Supply of terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
661Fixing & placing of terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
662Supply of glazed stoneware pipes grade "A"100mm dia SW pipe
663Laying and jointing glazed stoneware pipes grade "A" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm dia SW pipe
664Laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe
665Supply of square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type
666Fixing of square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design150 x 100 mm size P type
667Supply of floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B (i) Double socketed pipes.
668a) 110mm dia P.V.C. pipe
669b) 90mm dia P.V.C. pipe
670Fixing of floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.
671a) 110mm dia P.V.C. pipe
672b) 90mm dia P.V.C. pipe
673Supply of UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
674Fixing of UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
675Supply of clean out plug (Astral)
676Fixing of clean out plug (Astral)
677Supply ofterminal guard.
678a) 110mm
679b) 90mm
680fixing of terminal guard.
681a) 110mm
682b) 90mm
683Supply of wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes.
684110mm bend
68590 mm bend
686110mm Coupler
68790mmCoupler
688110x110x110 mm Single tee with door
68990x90x90 mm Single tee with door
690Fixing of wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
691110mm bend
69290 mm bend
693110mm Coupler
69490mmCoupler
695110x110x110 mm Single tee with door
69690x90x90 mm Single tee with door
697SUPPLY OF 1.50 SQMM FRLSH PVC INSULATED SINGLE CORE COPPER CONDUCTOR CABLE
698SUPPLY OF 2.50 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
699SUPPLY OF 4.00 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
700SUPPLY OF 6.00 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
701SUPPLY OF 10 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
702SUPPLY OF 16 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
703SUPPLY OF 25 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
704SUPPLY OF HEXAGONAL/ROUND GP FAN BOX OF APPROVED MAKE MADE UP OF 1 MM THICK ISI MARKED GP SHEET SPOT WELDED FOUR TO EIGHT HOLES OF 25.4 MM FOR PIPE ENTRY OF THE BOX DULY SCREEWED FITTED WITH 300 MM ROUND ZINK COATED MS BAR x 12 MM.
705SUPPLY OF CEILING FAN WITH FAN MOTOR OF AC PERMANENT INSULATION, CAPACITOR RATING CONFORMING TO BEE 5 STAR. THE RATRD VOLTAGE220/240 VOLTS, 50 Hz, SINGLE PHASE, AC THE FAN ASSEMBLE SHOULD CONSISTS OF DOWN ROAD BLADES, SHACKLE CANOPIES WITH DOUBLE BALL BEARING SYSTEM – 1200 MM SWEEP
706SUPPLY OF ELECTRONIC FAN REGULATOR (MODULAR) 120- 280 V ISI MARKED
707SUPPLY OF LED TUBE LIGHT WITH METAL HEAVY DUTY BOX TYPE BATTEN LIGHT FITTING 2x 22 WATT SUITABLE FOR 2x22 WATT POLYCARBONATE TUBE LIGHT INCLUDING TUBE ETC SUITABLE FOR BOTH SURFACE.
708SUPPLY OF LED TUBE LIGHT WITH METAL HEAVY DUTY BOX TYPE BATTEN LIGHT FITTING 1x 22 WATT SUITABLE FOR 1x22 WATT POLYCARBONATE TUBE LIGHT INCLUDING TUBE ETC SUITABLE FOR BOTH SURFACE.
709SUPPLY OF RECESS/SURFACE MOUNTING ROUND 10 TO 15 WATT, CUT OUT 125 MM, HEIGHT MIN 40 MM, LED DOWNLIGHTER HAVING POWDER COATED DIE CAST ALUMINIUM HOUSING WITH HEAT SINK, DIFFUSER / REFLECTOR AND DRIVER SET, SUITABLE FOR 24 Hr CONTINUOUSOPERATION
710SUPPLY OF SINGLE LED LIGHT WALL BRACKET ON MATCHING MDFEG BOARD BASE
711WATER TIGHT OBLONG 10 WATT LED BULKHEAD LUMINERY WITH DRIVER SET CONFORMING TO IP 65 AND ABOVE PROTECTION COMPLETE.
712SUPPLY OF SURFACE / FLUSH MOUNTING DISTRIBUTION BOARDS WITH ADDITIONAL METAL DOOR WITHOUT MCB COMPLETE. (CAT A)
7134 WAY TPN
7146 WAY TPN
7158 WAY TPN
716SUPPLY OF 6 AMP TO 32 AMP (10 KA) SP MCB (CAT A)
717SUPPLY OF FOLLOWING MCBS
71840 AMP. FP MCB (CAT A)
71963 AMP. FP MCB (CAT A)
72040 AMP. TP MCB (CAT A)
72163 AMP. TP MCB (CAT A)
722SUPPLY OF SURFACE / FLUSH MOUNTING V TPN DISTRIBUTION BOARDS WITH ADDITIONAL METAL DOOR WITHOUT MCB COMPLETE. 4 WAY V TPN
723SUPPLY OF FOLLOWING MCCBS
72463 AMP. FP MCCB (CAT A)
725100 AMP. FP MCCB (CAT A)
726125 AMP. FP MCCB (CAT A)
727160 AMP. FP MCCB (CAT A)
728SUPPLY OF POWER PLUG WITH 15 A / 250 V FLUSH TYPE SWITCH AND 5 PIN 15 A /250 V FLUSH TYPE UNIVERSAL SOCKET IN SUITABLE MS BOX 175MMx100MMx50MM SIZE (MODULAR)
729SUPPLY OF SINGLE POLE MCBS BLANKING PLATE COMPLETE
730SUPPLY OF GI PLATE FOR EARTHING SIZE 600 MM x 600MM x 6 MM
731SUPPLY OF GI PIPE 20 MM DIA
732SUPPLY OF GI WIRE 8 TO 10 SWG
733SUPPLY OF CI FRAME (30 SQCM) WITH HINGED COVER
734SUPPLY OF GI STRIP FOR EARTHING PURPOSE 25 MMx 3 MM
735SUPPLY OF ALUMINIUM CONDUCTOR PVC INSULATED ARMOURED, SERVED, SHEETED CABLE 1000 VOLTS
73695 SQMM 3.5 CORE
73770 SQMM 3.5 CORE
73850 SQMM 3.5 CORE
73935 SQMM 3.5 CORE
74025 SQMM 3.5 CORE
74110 SQMM 4 CORE
742SUPPLY OF BRASS NICKLE PLATED COMPRESSION GLAND FOR PVC INSULATED AND ARMOURED SERVED SHEETED UNDERGROUND CABLE INCLUDING RUBBER RING
74395 SQMM 3.5 CORE
74470 SQMM 3.5 CORE
74550 SQMM 3.5 CORE
74635 SQMM 3.5 CORE
74725 SQMM 3.5 CORE
74810 SQMM 4 CORE
749SUPPLY OF PALM / PIN TYPE COPPER TIN PLATED CABLE SOCKETS (LUGS) TO THE CABLE LEADS, INSULATING WITH TAPE
75095 SQMM
75170 SQMM
75250 SQMM
75335 SQMM
75425 SQMM
75516 SQMM
75610 SQMM
7576 SQMM
758SUPPLY OF GI BOX ALONWITH MODULAR BASE AND COVER PLATE FOR MODULAR SWITCHES IN RECESS1 OR 2 MODULE (75 MMx75 MM)
759SUPPLY OF TELEPHONE SOCKET OUTLET (MODULAR)
760SUPPLY OF TV ANTENNA SOCKET OUTLET (MODULAR)
761SUPPLY OF BELL PUSH (MODULAR)
762SUPPLY OF CALL BELL / BUZZER SUITABLE SINGLE PHASE 230 V
763SUPPLY OF TELEPHONE CABLE FOLLOWING PAIR 0.5 SQMM FR PVC INSULATED ANNEALED COPPER CONDUCTOR, UNARMOURED
7642 PAIR
76510 PAIR
76620 PAIR
767SUPPLY OF CO-AXIAL TV CABLE RG-6 GRADE 0.7 MM SOLID COPPER CONDUCTOR PE INSULATED SHEETED WITH FINE TINNED COPPER BRAID AND PROTECTED WITH PVC SHEET
768SUPPLY OF 10 PAIR JUNCTION BOXES FOR FLOORS AND BUILDING WITH KRONE CONNECTORS
769SUPPLY OF 20 PAIR JUNCTION BOXES FOR FLOORS AND BUILDING WITH KRONE CONNECTORS
770SUPPLY OF 50 PAIR JUNCTION BOXES FOR FLOORS AND BUILDING WITH KRONE CONNECTORS
771SUPPLY OF EXHAUST FAN OF AC 230/250 V, 50 Hz INCLUDING NUTS & BOLTS, MOUNTING FRAME AND OTHER ACCESSORIES.300 MM SWEEP
772SUPPLY OF ENERGY METER (3 PHASE) AND OTHER ACCESSORIES.
773SUPPLY OF WALL FANOF AC 230/250 V, 50 Hz INCLUDING NUTS & BOLTS, MOUNTING FRAME AND OTHER ACCESSORIES. 450 MM SWEEP
774SUPPLY OF EXHAUST FAN OF AC 230/250 V, 50 Hz INCLUDING NUTS & BOLTS, MOUNTING FRAME AND OTHER ACCESSORIES.450 MM SWEEP
775SUPPLY OF WEIRED DECORATIVE MIRROR LIGHT SUITABLE 9 WATT LED WITH LAMP COMPLETE
776SUPPLY OF FACTORY WEIRED INTEGRAL LED FLOOD LIGHT LUMINARIES WITH DIE CAST ALUMINIUM HOUSING BUILT WITH DRIVER SET SUITABLE FOR 40 TO 50 WATT CONFOMING TO IP 65/66 PROTECTION COMPLETE.
777SUPPLY OF SWICHES (MODULAR) 5 AMP
778SUPPLY OF SOCKETS (MODULAR) 5 AMP
779SUPPLY OF PVC CONDUIT PIPE 25 MM DIA
780SUPPLY OF ROUND SHEET
781SUPPLY OF CEILING ROSE
782SUPPLY OF HOLDER FOR BULBS
783FIXING OF MAIN LT PANEL
784FIXING OF MAIN EM PANEL
785FIXING OF SUB PANEL
786FIXING OF SUB EM PANEL
787FIXING OF CAPACITOR PANEL 150KVAR
788FIXING OF FEEDER PILLER
789FIXING OF STREET FEEDER PILLER
790Supply of Coarse sand
791Supply of Cement50 KG
792Supply of Brick M150
793Supply of Stone Grit 20 mm
794Supply of Stone Ballast 40 mm
795Supply of Tor Steel 8 mm dia
796Supply of Tor Steel 10 mm dia
797Supply of Tor Steel 12 mm dia
798Supply of Tor Steel 16 mm dia
799Supply of Tor Steel 20 mm dia
800Supply of Tor Steel 25 mm dia
801Supply of MS Fabrication For Door Window and Ventilator
802Supply of Water Proofing Chemical CICO TAPECRETE P151
803Supply of Y Shaped Angle Iron Post 40x40x6
804Supply of Kota Stone 22 mm thick
805Supply of Vitriried Floor Tile 8 to 10 mm thick in 600x600 mm size
806Supply of Wall Tile Glazed/ Ceramic floor tiles
807Supply of SS Railing 304 grade
808Supply of MS Collapsible Channel
809Supply of Rolling Shutter With Ball Bearing
810Supply of Granite
811Supply of Cinder
812Supply ofChequred Tile 300x300 mm size
813Supply of MS Gate made of MS Hollow sections
814Supply of INTERLOCKING PAVERS 80 MM M30 Mpa
815labour charge for construction of rcc over head tankas per design and drawing &directions of Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail