Tender For Repair And Maintenance Of Central Type And Package Type Ac Plants At Air Force Station Jaisalmer, jaisalmer-Rajasthan

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Central Type And Package Type Ac Plants At Air Force Station Jaisalmer. Submission Date for this Tender is 10-07-2023. HVAC Tenders in jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38038962
Corrigendum : Tender For Repair And Maintenance Of Central Type And Package Type Ac Plants At Air Force Station Jaisalmer
Open Tender
Indian
Rajasthan
jaisalmer
10-07-2023

Tender Details

Repair And Maintenance Of Central Type And Package Type Ac Plants At Air Force Station Jaisalmer

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work : REPAIR AND MAINTENANCE OF CENTRAL TYPEAND PACKAGE TYPE AC PLANTS AT AIR FORCE STATION JAISALMER
Sl. No. Item Description
1M&L for comprehensive maintenance of Central Type Water Cooled AC Plants/ductable package type AC, AHU"s and connected machineries and other equipments as described below by the authorised representative/agent of OEM:- (A) EQUIPMENT DETAILS:-
2600 TR AC Plant (2x300 TR working + 1x300 TR standby)-01, Make : Blue Star
3100 TR AC Plant (2x50 TR working + 1x50 TR standby)-01, Make : Blue Star
450 TR AC Plant (1x50 TR working + 1x50 TR standby)-01, Make : Blue Star
544 TR AC Plant (2x22 TR working + 1x22 TR standby)-02, Make : Voltas
622 TR AC Plant (2x11 TR working + 1x11 TR standby)-04, Make : Voltas-03, Hitachi-01
720 TR AC Plant (2x10 TR working + 1x10 TR standby)-01, Make : Voltas
817 TR ductable AC Plant (2x8.5 TR working + 1x8.5 TR standby)-04, Make : Voltas
911 TR ductable AC Plant (1x11 TR working + 1x11 TR standby)-02, Make : Voltas
108.75 TRductable AC -05, Make : Voltas
11Connected refrigerant controls like pressure gauges, pressure switches, thermostats & solenoid valves, Connected water pipe lines & valves, Connected Air ducting, dampers, grills, air diffusers and insulation both acoustic and thermal, Connected electrical system including distribution boards and MCCB panels, Connected instrumentation, controls and cabling.
12(B) CHILLER SYSTEMS:- 1. Check flow switch operation for proper operation. 2. Checking condition and setting of panel controls, operating controls, safety controls to ensure optimum performance, reliability and replacement of the same if found necessary. 3. Cleaning of Pot strainers in water circuit. 4. Lubricating all bearings as required. 5. Checking/rectifying of alignment of coupling in direct driven components. 6. Checking of AC systems and monitoring for any oil or gas leakages. 7. Checking of pressure controls (HP/LP/OP/WP), refrigerant pressure gauges, water pressure gauges, temperature gauges, expansion valves, refrigerant valves, strainer/driers, thermostats and solenoid valves etc.
13(C) AHU SYSTEMS:- 1. Checking the electrical control and set points for operation and adjusting the setting if necessary.Inspect cables for loose/loaded terminals, rectify if necessary. 2. Check AHU motor mounts for undue vibrations and replace the mounts if necessary within the quoted rates. 3. Checking of AHU fan motor, Impeller housing, shaft and bearings. 4. Checking of belt tension and alignment of motor, tightening of V-belts. 5. Cleaning of AHU outlets like diffusers, grills etc. with a standard chemical cleaning agent recommended by the OEM within the quoted rates. 6. Side covers shall be opened and damaged nut and bolts shall be replaced within the quoted rates. 7. AHU coil shall be cleaned with a standard chemical cleaning agent recommended by the OEM within the quoted rates. 8. Check for condition of motor pulley, blower pulley and alignment of both the pulleys and the same shall be repaired/replaced if found any abnormality within the quoted rates. 9. Check for V-belts and filter assembly/canvas cloth condition and replace if required. Note : Cost of V-belts and filter assembly shall be measured and paid under the relevant items of this schedule. 10. Motor terminals shall be checked and properly tightened. 11. Checking/rectifying of alignment of coupling in directed driven components. 12. Checking, rectification, repair and replacement of GI ducting, thermal/acoustic insulations, dampers, tinkering, welding and painting to ensure smooth function of the equipments.
14(D) CHILLER WATER PUMP:- 1. Checking the condition and setting of panel controls, operating controls and safety controls to optimum performance, reliability and replacement of the same, if found necessary within the quoted rates. 2. Inspect cables for loose/loaded terminals rectify if necessary within the quoted rates. 3. Base bolts, coupling bolts shall be tightened rigidly and check for alignment of coupling and coupling bushes shall be replaced including replacement of the rusted bolts shall be replaced with new ones within the quoted rates. 4. Checking/rectifying of alignment of coupling in direct driven components.
15(E) CONDENSER WATER PUMP:- 1. Checking the electrical control and set points for operation and adjusting the setting if necessary.Inspect cables for loose/loaded terminals, rectify if necessary. 2. Inspect contacts for chatler marks and clean. 3. Base bolts, coupling bolts shall be tightened rigidly and check for alignment of coupling and coupling bushes shall be replaced including replacement of the rusted bolts shall be replaced with new ones within the quoted rates. 4. Checking/rectifying of alignment of coupling in direct driven components. (F) ALL ELCTRICAL PANELS AND CONTACTORS:- 1. Checking the electrical control and set points for operation and adjusting the setting if necessary. 2. Inspect cables for loose/loaded terminals rectify if necessary within the quoted rates. 3. Checking electrical panels & cabling at plant room and all control cabling.
16(G)COOLING TOWERS:- 1. Checking of cooling tower nozzles, sprinklers, cooling tower motors and fans. 2Inspect cables for loose/loaded terminals, rectify if necessary within the quoted rates.Checking the condition and setting of panel controls, operating controls and safety controls to optimum performance, reliability and replacement of the same/ if found necessary within the quoted rates. 3. Valve gland leaks shall be arrested by changing gland packing material.Check for proper functioning of valves and repair the same if found any abnormality within the quoted rates. (H) FAN COIL UNIT:- 1. Checking the electrical control and set points for operation and adjusting the setting if necessary within the quoted rates. 2. Check FCU motor mounts undue vibrations.Replace mounts if necessary within the quoted rates. 3. Inspect cables for loose/loaded terminals, rectify if necessary within the quoted rates. (J) CENTRIFUGAL FAN, EXHAUST FAN:- 1. Checking the electrical control and set points for operation and adjusting the setting if necessary within the quoted rates. 2. Inspect cables for loose/loaded terminals, rectify if necessary within the quoted rates. 3. Check fan motor mounts for undue vibrations.Replace mounts if necessary within the quoted rates.
17(K) GENERAL:- 1. Checking the plant performance. 2. Checking of faulty spare parts of all electrical panels/motor control panel, pump panels, winding of motors and relay etc. and taking out defective spares against repaired or new spares. Note : Cost of new spares will be measured and paid under the relevant items of this schedule. 3. Checking to be done to notice abnormal operational noise in the running of plant/condenser/chilled water pump and corrective action to be taken as required. 4. The contractor should check over heating of compressor/ condensor/chilled water pumps and corrective action be taken as required. 5. Any leakage due to gland packing of pumps/refrigerant or otherwise is to be checked and corrective action should be taken immediately. 6. The contractor is required to carryout replacement of gland packing, inspection and cleaning of pumps, repair/replacement of control valves etc within quoted rates. 7. Contractor shall ensure proper ground earthing of plant, motors and requisite corrective action is to be taken. 8. Checking of electrical equipments like safety circuits, SFUs, Timer relays, Single phase preventors, Contactors, OLRs, Selector switches, Ammeters and Voltmeters etc. and rectification/repair/ replacement of the defective items. 9. Checking of all water pipe lines, water line valves including non-return check valves, water strainers and repair/ rectification/ replacement of defective parts. 10. Checking, maintaining and ensuring smooth function of the equipments without any abnormalities in noise, temperature, pressures and current drawn by the motors and carrying out rectification/repair/replacement of defective parts. Note : Spares to be replaced will be measured and paid under the relevant items of this schedule.
18(L) RECOVERIES FOR NON PERFORMANCE - 1. The quoted rate is deemed to be inclusive of Attending to emergency complaints/break-down by employing additional workmen as required within the quoted rates. 2.Call made before 1600 Hrs shall have to be attended on same day. Call made after 1600 Hrs shall be attended by 1000 Hrs on next day. 3.The firm has to attend the unscheduled service calls as and when required for locating the faults and rectify the same immediately.The contractor should attend to the breakdown of plant on priority basis.Records of the break down should be maintainted by him as directed by Engr-in-charge.Efforts should be made to restore working of plant within 8 hours of break so that regular air conditioned supply to users in maintained.If need be, the extra workmen shall be arranged by the contractor within quoted rates.In case of failure to rectify and complete the work as explained in the scope of work within the time limit as mentioned below, the work shall be got carried out through other agency at the risk and cost of contractor without further notice to them. 4. The corrective/breakdown maintenance is to be carried out any time during 24hrsx365days inclusive of all Sunday & Holidays.
195. Minor Maintenance :- Inclusive of Repairing and Replacement of all Spares/Components and all other associated accessories which are covered otherwise and attention of all defects other than major defects. (i) Respose Time (Maximum) - 03 hours (ii) Attending Time (Maximum) - 06 hours 6. Major Maintenance :- Inclusive of Repairing and Replacement of all Spares/Components and all other associated accessories which are covered otherwise and attention of all defects other than major defects. (i) Respose Time (Maximum) - 03 hours (ii) Attending Time (Maximum) - 24 hours (Should be in proportion with the type of failure). 7. In case of major complaints such down of system more than 36 hours whenever the standby equipment is not available for service a penalty of Rs 1000/- per day shall be imposed subject to maximum of Rs 15000/- depending upon the continuity of the shutdown. 8. The complaints which cannot be attended to within above specified time limit on technical grounds, be brought to knowledge of Engr-in-charge for taking suitable remidial action.
209. The scope of work includes preventive maintenance of air conditioning plant, etc. The same should be carried out on Saturdays, Sundays and holidays with prior intimation to Engr-in-charge.Contractor shall work out time schedule for carrying out preventive maintenance in consultation with Engr-in-charge. 10. The contractor shall be entirely responsible for all safety precautions required 11. All units of the AC plants like Compressors, pumps, motors, blower, etc. should be maintained in optimum condition.They will be checked for proper functioning and defective spares will be replaced if necessary.Consumables like oil, gas, contactors, switches, valves, etc and jobs like descaling, rewinding, gas charging, oil filling etc. will be measured and paid under the respective items of this schedule. 12. No additional payment shall be made for transportation of equipment from the AC plant site to the Firm"s ware house or delivery of the materials to the AC plant site at any point of time. 13. The firm shall make good all the losses occurred during servicing, overhauling, repairing and maintenance of plants without any additional cost. 14.The Refrigeration Mechanic deployed should have minimum qualification as ITI in refrigeration and air conditioning trade with at least five years experience. The same shall be verified by the Engineer-in-Charge. 15. Contractor shall ensure all safety precautons for Workmen and materials at work. In case of any accident, mishap, death and casuality is met at site of Work, the contractor shall be responsible and nothing extra shall be admissible to him on this account.
21(M) The following maintenance services are not covered under comprehensive maintenance of Central AC plant:- 1. Repair/overhaul of the compressor, condensor, chiller, motor, cooling tower, cooling tower fittings, heating/cooling coils, fans, FCUs, AHU, Sheet metal parts, valves, sensors etc. 2. Repair/replacement of electrical main switch/circuit breaker, main incoming cable, fuses and indication lamps. 3. Repair/replacement of component of main electrical distribution board and distribution power control cabling. 4. Repair/replacement of chilled water and condenser water valves and water piping, and all kind of masonry/ structural work. 5. Ducting and its accessories like dampers of all types, Thermal and acoustic installation, all type of piping and valves, electrical panel cabling, control wiring, bulbs and fuses. 6. Repair/replacement of fine filters and absolute filters. 7. Rewinding job of motors etc. 8. Gas charging job. 9. Compressor oil filling job. 10.Descaling job(s). 11.Cleaning of cooling tower 12.Cleaning of AHU and its filters. 13.Cleaning of Air ducts. 14.Painting of any component of AC plant. 15.Repair/overhauling of hot water generator and its system.
22Descaling of Condenser unitof 600TR AC Plant, including AHU units (11 Nos), cooling towers and pipe lines with descaling Chemical (As recommended by the OEM ) including replacement of gaskets and tighten with new nut and bolts, painting to cooling tower and all connected pipelines with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note : (i) 03 condensor unit, all connected AHU units, cooling towers and connected pipelines will be measured as one Job. (ii) Descaling chemical shall be included in the quoted rate. (iii)Strength of descaling solution shall be measured with pH paper and if the strength is less than 30%, then the descaling shall be done again by the contractor at his own cost to achieve the desired level of pH and nothing shall be payable extra on this account. (iv) The job also includes material and labour for making leak proof refrigerant system by vaccumising with in 7.6 mm HG carried out using N-2 gas and maintaining for three hours, at the end of this period vaccum should be maintained for 24 hours complete all as specified and directed.
23Descaling of condensor unit of 100 & 50 TR AC Plants including all AHU units, cooling towers and pipe lines with descaling Chemical (As recommended by the OEM ) including replacement of gaskets and tighten with new nut and bolts, painting to cooling tower and all connected pipelines with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note : (i) 03 condensor unit, all connected AHU units, cooling towers and connected pipelines will be measured as one Job. (ii) Descaling chemical shall be included in the quoted rate. (iii)Strength of descaling solution shall be measured with pH paper and if the strength is less than 30%, then the descaling shall be done again by the contractor at his own cost to achieve the desired level of pH and nothing shall be payable extra on this account. (iv) The job also includes material and labour for making leak proof refrigerant system by vaccumising with in 7.6 mm HG carried out using N-2 gas and maintaining for three hours, at the end of this period vaccum should be maintained for 24 hours complete all as specified and directed.
24Descaling of condensor unit of 44 TR AC Plants including all AHU units, cooling towers and pipe lines with descaling Chemical (As recommended by the OEM ) including replacement of gaskets and tighten with new nut and bolts, painting to cooling tower and all connected pipelines with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note : (i) 03 condensor unit, all connected AHU units, cooling towers and connected pipelines will be measured as one Job. (ii) Descaling chemical shall be included in the quoted rate. (iii)Strength of descaling solution shall be measured with pH paper and if the strength is less than 30%, then the descaling shall be done again by the contractor at his own cost to achieve the desired level of pH and nothing shall be payable extra on this account. (iv) The job also includes material and labour for making leak proof refrigerant system by vaccumising with in 7.6 mm HG carried out using N-2 gas and maintaining for three hours, at the end of this period vaccum should be maintained for 24 hours complete all as specified and directed.
25Descaling of condensor unit of 11 to 22 TR AC Plants including all AHU units, cooling towers and pipe lines with descaling Chemical (As recommended by the OEM ) including replacement of gaskets and tighten with new nut and bolts, painting to cooling tower and all connected pipelines with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note : (i) 03 condensor unit, all connected AHU units, cooling towers and connected pipelines will be measured as one Job. (ii) Descaling chemical shall be included in the quoted rate. (iii)Strength of descaling solution shall be measured with pH paper and if the strength is less than 30%, then the descaling shall be done again by the contractor at his own cost to achieve the desired level of pH and nothing shall be payable extra on this account. (iv) The job also includes material and labour for making leak proof refrigerant system by vaccumising with in 7.6 mm HG carried out using N-2 gas and maintaining for three hours, at the end of this period vaccum should be maintained for 24 hours complete all as specified and directed.
26Supply (in company sealed cylinders of any capacity) and charge refrigerant gas R-22 for filling in compressors as per requirement complete all as specified and directed. Note : If the recharged refrigerant gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to the department.
27Supply (in company sealed cylinders of any capacity) and charge refrigerant gas R-134 a for filling in compressors as per requirement complete all as specified and directed. Note : If the recharged refrigerant gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to the department.
28Supply (in company sealed cylinders of any capacity) and charge refrigerant gas R-407 c for filling in compressors as per requirement complete all as specified and directed. Note : If the recharged refrigerant gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to the department.
29M&L for topping up/charging of Compressor oil non freezing type in factory sealed containers (as per existing grade and type recommended by OEM) complete all as specified and directed.
30S&F in repair Fan Belt for AHU of size B-76/78/106/126, A-23/27/28/29/30/44/56/57/61 or any other size as per existing complete all as specified and directed.
31M&L for disconnecting, dismantling, taking down burnt out chiller motor/cooling tower motor/condensor pump/Hot water pump from its base and transporting the motor to the workshop and back, refixing, testing on full load, commissioning the repaired motor after carrying out the following repairs :- (i) Opening the side covers and removing the rotor and cutting/removing the burnt coils/winding from stator (ii) Cleaning the slots carefully (iii) Rewinding the stator using super enamelled copper conductor wire with same size, number of coils, number of turns/coils as per data acquired from the old burnt motor, including varnishing of two coats, drying using electric furnace (iv) Testing the coils for continuity and no current passing through the stator core (v) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance or vibrations (vi) Re-assembling the rotor and connecting the end terminals to the terminal plate of the motor, closing the ends with side covers (vii) Testing and commissioning the electric motor connected to the electric supply to its full load by connecting the compressor (viii) Fixing of new nuts, bolts and washers Note : Parts renewed i.e. Ball bearing, greasing and oiling shall be deemed to be included in the quoted rates.
3250 HP
3330 HP
3420 HP
3515 HP
367.5 HP
3705 HP
3803 HP
3902 HP
40S&F in repair drier filter suitable for compressors of capacity 5.5 TR to 13 TR of ductable Central AC plant/package type Air Conditioner Plant TR complete all as specified and directed. Make: Danfoss/indofoss
41S&F in repair Chillar Plant Heater of suitable capacity as per existing complete all as specified and directed.
42S&F in repairs Dehumidifier Thermostate of suitable capacity as per existing complete all as specified and directed
43S&F in repair Chillar Plant Sensor as per existing complete all as specified and directed.
44S&F in repair Pressure Gauge 4" dial 0-21 Kgs rating in repair complete all as specified and directed.
45S&F in repair Expansion Valve suitable for compressor of capacity 11TRto 13 TR as per existing size complete all as specified and directed.
46S&F in repair Bearing Shaft as per existing size complete all as specified and directed.
47S&F in repairs Heating rod of capacity 2 KW to 3 KW as per existing for dehumidifier/ humidifier complete all as specified and directed.
48S&F in repair Pump seal complete all as specified and directed.
49S&F in repair Air Purching valve with Ball valve of size 15mm complete all as specified and directed.
50S&F in repair Fins for cooling towers, Flute size 12mm and 19mm, thickness 0.175mm to 0.20mm, 24" x 12" x 6" (600mm x 300mm x 150mm) or any other size as per sample complete all as specified and directed.
51S&F in repair Switch Disconnector fuse unit (heavy duty) for power distribution and motor protection (in Open Execution TPN) capacity 630 Amps, TPN, 415 volts, SDF suitable for BS type HRC Fuses complete with all accessories in replacement complete all as specified and directed.
52S&F in repair Contactor of capacity 400 Amps, 3Pole, 415 Volt, 50 Hz suitable for 160 KW/ 215 HP load with all accessories complete all as specified and directed.
53S&F in repair Contactor of capacity 250/275 Amps, 3 Pole, 415 Volt, 50 Hz suitable for 110 KW/ 150 HP load with all accessories complete all as specified and directed.
54S&F in repair Contactor of capacity 115/145 Amps, 3 Pole, 415 Volt, 50 Hz suitable for 75 KW/ 100 HP load with all accessories complete all as specified and directed.
55S&F in repair MCCB with Microprocessor release, 4 Pole, 630 Amps rating, rupturing capacity 50 kA, 415 Volt grade, AC, 50 Hz (Ics = 100% Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
56S&F in repair MCCB with Microprocessor release, 4 Pole, 400 Amps rating, rupturing capacity 50 kA, 415 Volt grade, AC, 50 Hz (Ics = 100% Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
57S&F in repair MCCB with Microprocessor release, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz (Ics = 100% Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
58S&F in repair MCCB with Microprocessor release, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz (Ics = 100% Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
59S&F in repair MCCB with Microprocessor release, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz (Ics = 100% Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
60S&F in repair MCCB with Microprocessor release, 4 Pole, 125 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz (Ics = 100% Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
61S&F in repair MCCB with Microprocessor release for motor backup protection of capacity 100 Amp, 4 Pole, breaking capacity 25 KA, 415 Volt, 50 Hz (Ics=100%Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
62S&F in repair MCCB with Microprocessor release for motor backup protection of capacity 63 Amp, 4 Pole, breaking capacity 16 KA, 415 Volt, 50 Hz (Ics=100%Icu), making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
63S&F in repairMCB, Single Pole, 32 Amps rating, with over load and short circuit protection "C" curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
64S&F in repairMCB, Three Pole, 32 Amps rating, with over load and short circuit protection "C" curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified and directed.
65S&F in repairPower Contactor capacity 40 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.
66S&F in repairPower Contactor capacity 32 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.
67S&F in repairPower Contactor capacity 18 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.
68Supply, lay, hang, joint and test Halogen Free Flame Retardant HRFR PVC insulated industrial cables unsheathed, 1100 volts grade single core of size 185 Sqmm laid in trenches/ducts, through pipe, under floorsetc including dismantling & taking out old unserviceable cable complete all as specified and directed. Note : One run of single core copper cable of size 185 Sqmm shall be measured as unit length.
69S&F in repair cooling tower motor of capacity 03 HP suitable for 22TR AC plant cooling tower with all accessories and mounting bracket & fan complete all as specified and directed.
70S&F in replacmentPump Motor coupling required for capacity 40 HP and 30 HP motor including taking down old unserviceable coupling complete all as specified and directed.
71S&F in replacement Relay 12-32 Amps, 8 Pin, 220V-240 Volt for hot water generator including taking down old unserviceable relay complete all as specified and directed.
72S&F in replacement Relay 40 Amps, 8 Pin, 220V-240 Volt for hot water generator including taking down old unserviceable relay complete all as specified and directed.
73S&F in replacementflow Control acuator and sensor for AHUs RC 981S 24V AC/28V DC Make: OMRON including taking down old unserviceable complete all as specified and directed.
74S&F in replacement of running capacitor, 50 MFD (2+2) and one point for blower motor suitable for AC of capacity 30/40 HP Motor Make: EPCOS / SYSCAP/ ASIAN/TIBCAB including taking down old unserviceable complete all as specified and directed.
75S&F in replacement of running capacitor, 100 MFD (2+2) and one point for blower motor suitable for A/C of capacity 30/40 HP Motor Make: EPCOS / SYSCAP/ ASIAN/TIBCAB including taking down old unserviceable complete all as specified and directed.
76S&F in repair electronic type single phase Preventor in existing panel boards (max 600V & min 380V) three phase 415 volts variation voltage 4% tripping time 2-5 second maximum including disconnection & taking down old unserviceable single phase preventor complete all as specified and directed. Make : Minilec/L&T/Siemens/ABB/BCH/Havells
77Find out the leakage and pressure test with filling N2 gas inside of the condensor and cooling coil of Package type AC Plant of 8.75/10/11 TR capacity and dismantling the same for repair the leakage point by brazing/soldering including taking down and refixing the unit and testing the AC unit complete all as specified and directed.
78Find out the leakage and pressure test with filling N2 gas inside of the condensor and cooling coil of Chiller Package (Water cooled) Air Conditioning Plant capacity 17 TR to 100 TR including dismantling the same for repair the leakage point by brazing/soldering including taking down and refixing the unit and testing the AC unit complete all as specified and directed.
79Find out the leakage and pressure test with filling N2 gas inside of the condensor and cooling coil of Chiller Package (Water cooled) Air Conditioning Plant capacity 600 TR including dismantling the same for repair the leakage point by brazing/soldering including taking down and refixing the unit and testing the AC unit complete all as specified and directed.
80S&F in repair Cooling Tower Sprinkler Assembly as per existing including taking down old unserviceable complete all as specified and directed.
81M&L for repair of leakage of cooling towers with following procedure Firstly applying resin on cleaned and dry surface and then Ist layer of fible glass reinfored strip, again layer of resin above resin layer Iind layer of fibre sheet and on the top of the surface finishing with the help of epoxy to make the cooling tower leake proof complete all as specified and directed.
82S&F in repair cooling tower Strainer filter as per sample fixed including taking down old unserviceable complete all as specified and directed.
83Supply, install, commission and test Compressor scroll type Copper wound working on R-22/R-407c, capacity 5.5 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied. Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Copeland Scroll Model Number ZR72KC-TFD-522, Serial No. 03B0903AT or equivalnet of Kirloskar/ELG.
84Supply, install, commission and test of Compressor scroll type Copper wound working on R-407c, Capacity 8.75 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied.Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Danfoss Model Number HCP109T4LC6 or equivalent.
85Supply, install, commission and test of Compressor scroll type Copper wound working on R-407c, Capacity 11 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied.Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Danfoss Model Number SZ185S4RC or equivalent.
86S&F in repairM2VPD of current range 5-30 Amp, Auxiliary Supply 230 Volt grade, 50 Hz, AC Supply, 5 Sec Curve MPD including taking down old unserviceable complete all as specified and directed.
87S&F in repairs Gas Charging Valve 1/4 inche as per existing complete all as specified and directed.
88S&F in repairs High pressure/ low pressure (HP/LP) cut out MP-5 complete all as specified and directed. Make : Indfoss/Danfoss as per existing complete all as specified and directed.
89S&F in repair P No 205 Bearing (set of two) for AC blowers including turning the shaft as per reqirement at site complete all as specified and directed.
90S&F in repair Temperature sensor for Air Contioner Plant capacity 10TR complete all as specified and directed.
91S&F in repair Liquid line valve for Air Conditioner Package unit 10TR capacity complete all as specified and directed.
92S&F in repair Blower Shaft suitable for Air Conditioner Plant capacity 10TR complete all as specified and directed.
93S&F in repair Blower suitable for Air Conditioner Plant capacity 10TR complete all as specified and directed.
94S&F in replacement Single Phase Preventor cat No MA51BC, 415 VAC, 3P3W, 50/60 Hz, contact 5A, "NO" @ 240 VAC (Res), 3A "NC" @240 VAC (Res) complete all as specified and directed.
95S&F in repair of Induction Blower Motor capacity 2.0 PH, Three Phase, 415 Volt grade, 50 Hz, AC supply, 1400 RPM, (As per Sample) complete all as specified and directed. Make : CG/Kiroskar/Hindusthan
96S&F in repair of Condensor Motor capacity 0.5 HP, Three Phase, 415 Volt grade, 50 Hz, AC supply complete all as specified and directed.Make : CG/Kiroskar/Hindusthan
97S&F in repair Condensor Motor capacity 0.75 HP, Three Phase, 415 Volt grade, 50 Hz, AC supply complete all as specified and directed.Make : CG/Kiroskar/Hindusthan
98S&F in repair Condensor Motor capacity 1.5 HP, Three Phase, 415 Volt grade, 50 Hz, AC supply complete all as specified and directed.Make : CG/Kiroskar/Hindusthan
99S&F in repair Aluminium Fan assembly with fan and blade for Air Conditioner Plant complete all as specified and directed.
100S&F in repair of Condenser fan Blade 22" complete all as specified and directed.
101Repair/maintenance and service of condensor fan motor for outdoor unit i/c ball bearing, studs, nuts, bolts, washers, gland packing, greasing etc as required complete all as specified and directed.
102S&F in repair Canvas from pakage unit to inlet duct including accessaries in return grill with accessaries complete all as specified and directed.
103S&F in repair MCB, TPN, 32 Amps rating, with over load and short circuit protection "C" curve and rupturing capacity 10 kA, 415 Volt grade, AC Supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
104S&F n repair MCB, TPN, 40 Amps rating, with over load and short circuit protection "C" curve and rupturing capacity 10 kA, 415 Volt grade, AC Supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
105S&F n repairMCB, TPN, 63 Amps rating, with over load and short circuit protection "C" curve and rupturing capacity 10 kA, 415 Volt grade, AC Supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
106Supply, install, connect and test electric driven centrifugal monoblock pump set of capacity 5.0 HP/3.7 KW, three phase, suction and delivery size 80x80mm including necessary fixing arrangement and including taking down old unserviceable pump complete all as specified and directed. Make : Kirloskar KDS 520+ or equivalent in CG/Havells
107S&F in repair of PLC controller for 33 TR chillar unit fixed complete all as specified and directed. Make : Softhard automation model No-33 TR/ HMI (5-30A) /Ser No-02/2K13-50 or equivalent.
108S&F in repair MPD of current range 5-30 Amp, Aux supply 0-11VAC, 0-13 VAC Volt, 5 sec curve MPD complete all as specified and directed. Make : Softhard automation Model - SCR 33 TR (MPD) or equivalent.
109S&F in repair 5000 Litre capacity rotational moulded PVC water storage tank, triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & overflow pipe and provision of wash out pipe etc. with 20mm bore ball valve with PVC float including dismantling & taking down old unserviceable water tank of capacity 5000 Litre complete all as specified and directed.
110S&F in repair blower motor pulley, as per sample complete all as specified and directed.
111S&F in repair phase indicator lamp of colour red, yellow and blue as per sample complete all as specified and directed.
112S&F in repair PVC insulated Flame Retardant Low Smoke & Halogen (FRLSH) multistranded copper conductor cables, 1100 volts grade confirming to IS 694, single core of size 6 Sqmm including replacement of all lugs/thimbles with new copper lugs/thimbles and including taking down old unserviceable wiring complete all as specified and directed.
113S&F in repair complete control wiring with complete interlocking of chiller units, condensers, chillers pump, cooling pump and AHU with Panels and including replacement of all lugs/thimbles and taking down old unserviceable wiring complete all as specified and directed.
114S&F in repair solenoid valve as per sample complete all as specified and directed.
115Properly fixing of tilted/overhanging ceiling diffuser to the existing duct including cutting of 600x600x5mm thick false ceiling wherever required complete all as specified and directed.
116Supply and pour corrosion inhibitors (Bicarbonates) complete all as specified and directed.
117Supply and pour algaecides & Biocides to kill algae and other related plant-like microbes in the water complete all as specified and directed.
118Supply and pour Scale inhibitor chemical (SCALE2/38249022) complete all as specified and directed.
119S&F in repair of nitrile rubber insulation of minimum thickness 25mm by applying suitable adhesive on ducts, condenser water pipe line and chiller water pipe line including taking down old complete all as specified and directed.
120S&F in repair Hepa filters of efficiency 99.97% down to 0.3 microns or higher efficiency complete all as specified and directed.
121S&F in replacement 80mm bore mild steel pipe Class "C" including all fittings such as bends, flanges jointed together by means of nuts, bolts and washers including welding and fixing of motors, pumps, butterfly valves and NRVs complete all as specified and directed. Note : NRVs and butterfly valves shall be measured and paid seperately.
122S&F in replacement 80mm bore butterfly valve of size PN 1.6 complete all as specified and directed.
123S&F in replacement 80mm bore non return valve (NRV) of size 80mm complete all as specified and directed.