}

Tender For Construction Of New State Of Arts Modern Mortuary Complex At Pt. B.D. Sharma, Uhs, Rohtak (Pdg. Fire Alarm System And Pa System Only), rohtak-Haryana

Public Works Department-PWD has published Tender For Construction Of New State Of Arts Modern Mortuary Complex At Pt. B.D. Sharma, Uhs, Rohtak (Pdg. Fire Alarm System And Pa System Only). Submission Date for this Tender is 26-06-2023. Fire Alarm Systems Tenders in rohtak Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

38020147
Tender For Construction Of New State Of Arts Modern Mortuary Complex At Pt. B.D. Sharma, Uhs, Rohtak (Pdg. Fire Alarm System And Pa System Only)
Open Tender
Indian
Haryana
rohtak
26-06-2023

Tender Details

Tender For Construction of New State of Arts Modern Mortuary Complex at Pt. B.D. Sharma, UHS, Rohtak (Pdg. Fire Alarm System and PA System only)

Key Value

Document Fees
INR 1000 /-
EMD
INR 23640.0 /-
Tender Value
INR 11.22 Lakhs /-

BOQ Items

Name of Work: Construction of New State of Arts Modern Mortuary Complex at Pt. B.D. Sharma, UHS, Rohtak (Pdg. Fire Alarm System and PA System only)
Sl. No. Item Description
1HSR Items
2[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
3NS Items
4SITC of Microprocessor based 2 wire fault tolerant, networkable type fire alarm / detection control panel (having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160-character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of workMakes: Honeywell Morley DXE/SIEMENS CEREBERUS / Bosch FPA 1000 Series / GST 200 (EN)
5SITC of Public Address System in Rack: consisting of the following (i) 120W Amplifier to suitable size Make: Honeywell / Bosch / Henrich (ii) Selector and all facility for announcement of different floor - 01 Set (iii) Interfaceunitforintegrationofmainfirealarmpanelwith public address system = 01 No.
6Supply, Installation, Testing and commissioning ofCelling Mount/wallmount Speaker with Plastic Mount or without mount as per site requirement for operation 6 Watts Make Honeywell/ BOSCH / Henrich
7SITC of addressable Heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required.Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Siemens Cerberus /Honeywell Morley / GST 200 (EN) / Bosch FPA 1000 Series
8SITC of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feature as required.Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Siemens Cerberus / Honeywell Morley / Bosch / Edwards
9SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Siemens Cerberus / Honeywell Morley /Bosch FPA 1000 Series / GST 200 (EN)
10SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Siemens Cerberus / Honeywell Morley /Bosch / Edwards
11SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self-test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Siemens Cerberus / Honeywell Morley / Bosch / Edwards
12SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make : Glolite / PES / OMEX
13SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment).Make: Siemens Cerberus / Honeywell Morley / Bosch / Edwards EST3
14SITC ofAddressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall beEN54/UL/VDS CertificationMake: Siemens Cerberus / Honeywell Morley / Bosch / Edwards
15SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Siemens Cerberus / Honeywell Morley / Bosch / Edwards
16SITC of minimum 500 Mtr. Range Siren provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer in charge. Make: National / Kheraj
17Supply and erection of PVC Insulated and FRLS Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 complete in all respect upto the entire satisfaction of Engineer in charge of the work.Make Polycab / Havells / Finolex (i) 2 core PVC unsheathed copper size 1.5 sq mm
18Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000 V rated with annealed copper conductor having XLPE Insulation, Steel Wire armouring, FRLS Outer seathing complete as required complete in all respect entire satisfaction of Engineer in charge of the work.Make: Polycab / Havells / Finolex
19Supply, installation, testing and commissioning of 12 U Standard rack to place all Av equipment Make Valrack / Comrack / Hive Networks (HN).
20SITC of battery backup for controllers (2 KVA UPS off line with 1 hour’s backup) and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make APC/ LIEBERT EMERSON/Microtek/Luminious
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail