Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of New Court Building in the Premises of District Court Building Buldhana Tq. Dist. Buldhana |
| 2 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.Basement & Gr. Floor |
| 3 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Basement & Gr. Floor |
| 4 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means Basement & Gr. Floor |
| 5 | Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingetc. complete. (Lift from1.5 to3.0m.) By Mechanical Means Basement & Gr. Floor |
| 6 | ExcavationforfoundationinHardmurum andbouldersincludingremoving theexcavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed,dewatering,preparingthebedforthefoundationandnecessarybackfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means Basement & Gr. Floor |
| 7 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramming ,watering including shoring andstrutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means Basement & Gr. Floor |
| 8 | Excavationfor foundationin Hardrock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyondthebuildingareastackingasdirected,dewateringandbackfillingwithavailable earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical Means Basement & Gr. Floor |
| 9 | Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed. Basement & Gr. Floor |
| 10 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete. Basement & Gr. Floor |
| 11 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. Basement & Gr. Floor |
| 12 | Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete. Basement & Gr. Floor |
| 13 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsoras directedincluding cutting,fabricating,hoisting,erectingfixinginposition, Makingriveted/bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. Fifth Floor |
| 14 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchotheritems includingbailingoutwater, Steelcentering, formwork,laying/pumping,compacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic,tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfullyautomaticmicro processor based PLC with SCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 16 | Providing andlaying Castinsitu/ReadyMixcement concrete M-15oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Fifth Floor |
| 17 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steelcenteringformwork,cover blockslaying/pumping, compactionfinishingtheformedsurfaceswithcementmortar1:3ofsufficientminimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 18 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 19 | First Floor |
| 20 | Second Floor |
| 21 | Third Floor |
| 22 | Fourth Floor |
| 23 | Fifth Floor |
| 24 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks,laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 25 | First Floor |
| 26 | Second Floor |
| 27 | Third Floor |
| 28 | Fourth Floor |
| 29 | Fifth Floor |
| 30 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 31 | First Floor |
| 32 | Second Floor |
| 33 | Third Floor |
| 34 | Fourth Floor |
| 35 | Fifth Floor |
| 36 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade) Basement & Gr. Floor |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Third Floor |
| 40 | Fourth Floor |
| 41 | Fifth Floor |
| 42 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/ quartzite/gneissmetalforR.C.C.canopyasperdetaileddesignsanddrawingsincluding steel centering, formwork, laying/pumping, compacting and roughening the surface if special finishistobeprovidedandcuringetc.complete(excludingreinforcement).withfully automatic micro processor based PLC withSCADA enabledreversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 43 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-30oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Basement & Gr. Floor |
| 44 | First Floor |
| 45 | Second Floor |
| 46 | Third Floor |
| 47 | Fourth Floor |
| 48 | Fifth Floor |
| 49 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-30oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsorasdirectedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction,finishing unevenandhoneycombedsurface withC.M.1:3of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Basement & Gr. Floor |
| 50 | First Floor |
| 51 | Second Floor |
| 52 | Third Floor |
| 53 | Fourth Floor |
| 54 | Fifth Floor |
| 55 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Basement & Gr. Floor |
| 56 | First Floor |
| 57 | Second Floor |
| 58 | Third Floor |
| 59 | Fourth Floor |
| 60 | Fifth Floor |
| 61 | Providing expansion joints in R.C.C. framed structure (interior column)with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Basement & Gr. Floor |
| 62 | First Floor |
| 63 | Second Floor |
| 64 | Third Floor |
| 65 | Fourth Floor |
| 66 | Fifth Floor |
| 67 | Providingexpansion jointsin R.C.C.framed structure(exteriorColumns)with plain premouldedfiller25mmthickand3mmthickalluminiumplate,holdfast,fixingT.W. battens on internal face, finishing etc. complete as directed. Basement & Gr. Floor |
| 68 | First Floor |
| 69 | Second Floor |
| 70 | Third Floor |
| 71 | Fourth Floor |
| 72 | Fifth Floor |
| 73 | Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed.Basement & Gr. Floor |
| 74 | First Floor |
| 75 | Second Floor |
| 76 | Third Floor |
| 77 | Fourth Floor |
| 78 | Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and3 mm thick aluminium plate as required, bituminous pouredfiller, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Fifth Floor |
| 79 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Basement & Gr. Floor |
| 80 | ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement & Gr. Floor |
| 81 | First Floor |
| 82 | Second Floor |
| 83 | Third Floor |
| 84 | Fourth Floor |
| 85 | Fifth Floor |
| 86 | ProvidingAutoclavedAeratedConcreteBlockmasonaryofconforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech orequivalentinHalfbrickthickwallincludingstrikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement & Gr. Floor |
| 87 | First Floor |
| 88 | Second Floor |
| 89 | Third Floor |
| 90 | Fourth Floor |
| 91 | Fifth Floor |
| 92 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Basement & Gr. Floor |
| 93 | First Floor |
| 94 | Second Floor |
| 95 | Third Floor |
| 96 | Fourth Floor |
| 97 | Fifth Floor |
| 98 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. Basement & Gr. Floor |
| 99 | Fourth Floor |
| 100 | Fifth Floor |
| 101 | ProvidingwaterproofbeddingforflooringofBathandWC25mmthickinC.M.1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Basement & Gr. Floor |
| 102 | First Floor |
| 103 | Second Floor |
| 104 | Third Floor |
| 105 | Fourth Floor |
| 106 | Fifth Floor |
| 107 | Providing andapplying twocoatsofHighAlbedopainthavingminimum SolarReflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTMC1371respectively,VOClessthan10cc/gm.Thecoatingthicknessandthe methodology of application shall strctly as per manufacturer\"s specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performanceofSRIandalsothedurabitityofcoating,allcompleteasperdirectionof Engineer - in- incharge. Fourth Floor |
| 108 | Fifth Floor |
| 109 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gapof 25 mm betweenrough shahabadand R.C.C. walls withcement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushingthejointshorizontallywithcementslurrymixedwithwaterproofingliquidfor width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom mostwithCementconcrete 1:2:4mixedwithwaterproofing liquid,curing,with7 yearsguaranteeoncourtfeestampofRs.100/-withponding testetccomplete.(excluding Cement concrete 1:3:6 base concrete) Basement & Gr. Floor |
| 110 | Providingandapplyingplaster/wallpunningwithplasterofparis(withplasterofparis material)in10to13millimeterthicknessto previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Basement & Gr. Floor |
| 111 | First Floor |
| 112 | Second Floor |
| 113 | Third Floor |
| 114 | Fourth Floor |
| 115 | Fifth Floor |
| 116 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:5without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Basement & Gr. Floor |
| 117 | First Floor |
| 118 | Second Floor |
| 119 | Third Floor |
| 120 | Fourth Floor |
| 121 | Fifth Floor |
| 122 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, ExteriorCompound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mmincluding scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Basement & Gr. Floor |
| 123 | First Floor |
| 124 | Second Floor |
| 125 | Third Floor |
| 126 | Fourth Floor |
| 127 | Fifth Floor |
| 128 | Providing and fixing GRC/FRP decorative emblem with details as per drawing with the state emblem and carvings as shown in 3 dimesion upto a thickness of 150 mm with scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete.Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement & Gr. Floor |
| 129 | First Floor |
| 130 | Second Floor |
| 131 | Third Floor |
| 132 | Fourth Floor |
| 133 | Fifth Floor |
| 134 | Providing and fixing GRC/FRP decorative curved festoon or garland with details as per drawing with carvings as shown in 3 dimesion upto a thickness of 150 mm with scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete.Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material & Basement & Gr. Floor |
| 135 | First Floor |
| 136 | Second Floor |
| 137 | Third Floor |
| 138 | Fourth Floor |
| 139 | Fifth Floor |
| 140 | Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes circular or elliptical as shown in the drawing or indicated by the Architect as mentioned below with all profiling. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material & Basement & Gr. Floor |
| 141 | First Floor |
| 142 | Second Floor |
| 143 | Third Floor |
| 144 | Fourth Floor |
| 145 | Fifth Floor |
| 146 | Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) as per approved manufactures specification and as per approved drawings. The thickness of GRC panel should Nost be less than 20mm with minimum 20mm thick GRC pads acting as stiffeners. Colour and texture should be approved by Engineer in charge. Fixing of GRC panel on primary structure shall be done by fry cladding method with the help of SS screw fixtures, MS angle cleats, fissures plug and Dowel pin etc. in proper aligment, line and level as per the approved drawing, Finishing with GRC powder filling the joints with paintable silicon sealant neatly between GRC panel and primary structure to provide one piece look including molding and cornice at junction of column and beamsas per approved drawings, including necessary MS fabrication work to support GRC structure, necessary scaffolding at all levels and staging etc. (Nosn SSR Item) Basement & Gr. Floor |
| 147 | First Floor |
| 148 | Second Floor |
| 149 | Third Floor |
| 150 | Fourth Floor |
| 151 | Fifth Floor |
| 152 | Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete.Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement & Gr. Floor |
| 153 | First Floor |
| 154 | Second Floor |
| 155 | Third Floor |
| 156 | Fourth Floor |
| 157 | Fifth Floor |
| 158 | Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete.Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass materialBasement & Gr. Floor |
| 159 | First Floor |
| 160 | Second Floor |
| 161 | Third Floor |
| 162 | Fourth Floor |
| 163 | Fifth Floor |
| 164 | Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete.Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement & Gr. Floor |
| 165 | First Floor |
| 166 | Second Floor |
| 167 | Third Floor |
| 168 | Fourth Floor |
| 169 | Fifth Floor |
| 170 | Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors as indicated by the Architect. Painting of the ceiling to be paid as per relevant Item. The design of the panel to include mouldings on the edge, designs within the mouldings varying from any shape or size within the outer edge as shown in the drawign and the entire area to be detailed and made in profile with mouldings, dentals, fluting, floral details, bosses, etc., Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Mode of Measurement: the entire area of the panel/freizeto be paid in area from out to out of the moulding edge. Nosthing extra to be charged for details or designs which are part of the false ceilign design under aNosther item. Basement & Gr. Floor |
| 171 | First Floor |
| 172 | Second Floor |
| 173 | Third Floor |
| 174 | Fourth Floor |
| 175 | Fifth Floor |
| 176 | Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1.5mm laminateon, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete & First Floor |
| 177 | Second Floor |
| 178 | Third Floor |
| 179 | Fourth Floor |
| 180 | Providing & Fixing in position, Acoustical Panelling made fromFabric wrapped Compressed polyester fibre nonwoven 9 mmpanels on, 50 x 50 mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete & First Floor |
| 181 | Second Floor |
| 182 | Third Floor |
| 183 | Fourth Floor |
| 184 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete & Basement & GR. Floor |
| 185 | First Floor |
| 186 | Second Floor |
| 187 | Third Floor |
| 188 | Fourth Floor |
| 189 | Fifth Floor |
| 190 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete & Basement & Gr. Floor |
| 191 | Providing fine cementfinish1.5 mm thick overgreen plastersurface including scaffolding curing etc. complete & Basement & Gr. Floor |
| 192 | Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete & Basement & Gr. Floor |
| 193 | First Floor |
| 194 | Second Floor |
| 195 | Third Floor |
| 196 | Fourth Floor |
| 197 | Fifth Floor |
| 198 | Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete & Basement & Gr. Floor |
| 199 | First Floor |
| 200 | Second Floor |
| 201 | Third Floor |
| 202 | Fourth Floor |
| 203 | Fifth Floor |
| 204 | Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete & Basement & Gr. Floor |
| 205 | First Floor |
| 206 | Second Floor |
| 207 | Third Floor |
| 208 | Fourth Floor |
| 209 | Fifth Floor |
| 210 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.Cmembersandbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete & Basement & Gr. Floor |
| 211 | First Floor |
| 212 | Second Floor |
| 213 | Third Floor |
| 214 | Fourth Floor |
| 215 | Fifth Floor |
| 216 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete & Basement & Gr. Floor. |
| 217 | First Floor |
| 218 | Second Floor |
| 219 | Third Floor |
| 220 | Fourth Floor |
| 221 | Fifth Floor |
| 222 | Providingandfixingfalseceilingwitheco-friendlylight-weightcalciumsilicatetilesof spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thickdensifiedmicrolookedgeand100%humidityresistanceincombustibleasperBS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal levelsuspendedgridofsize600x600mmmadefromhotdippedG.I.steelsectionsion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, mainT runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middleofthefirstcrossedTineachpaneltoformgridof1200mmx600mmrestingon peripherywallProfilewallsection19mm (7+7)x19mmx0.40thicknessesandlayingfalse ceiling forservices like diffusersgrillsincluding cutting,making opening forlightfittings, fixtures,,smoke detectorsetc.,whereverrequired. MainT runnerssuspendedfrom ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mmdiaand 50mmlongdash fastener,4mmdiaG.I. adjustablerods with powder- coated/goodqualityG.I.leveladjustmentclipsof35x35x0.8mmspaced@1200,center-to- center along main T all complete at all heights as per the specifications, drawings and as per & Basement & Gr. Floor |
| 223 | First Floor |
| 224 | Second Floor |
| 225 | Third Floor |
| 226 | Fourth Floor |
| 227 | Fifth Floor |
| 228 | Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete & Basement & Gr. Floor. |
| 229 | First Floor |
| 230 | Second Floor |
| 231 | Third Floor |
| 232 | Fourth Floor |
| 233 | Fifth Floor |
| 234 | Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete & Basement & Gr. Floor |
| 235 | First Floor |
| 236 | Second Floor |
| 237 | Third Floor |
| 238 | Fourth Floor |
| 239 | Fifth Floor |
| 240 | Providing and laying vitrified stone effect finish tileshaving size 590 to 605 mm x 590to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in1:4 cement mortar including requiredpositionlaidonabedof1:4cementmortarincluding neatcementfloat, filling joints, curign and cleaningetc. complete & Basement & Gr Floor |
| 241 | First Floor |
| 242 | Second Floor |
| 243 | Third Floor |
| 244 | Fourth Floor |
| 245 | Fifth Floor |
| 246 | ProvidingandfixingheavydutyinterlockingconcreteColouredpavingblocksof80mm thickness of having a strength of 300 Kilogram/Sq.cm. of approvedquality andshape ona bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete & Basement & Gr. Floor |
| 247 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete & Basement & Gr. Floor |
| 248 | First Floor |
| 249 | Second Floor |
| 250 | Third Floor |
| 251 | Fourth Floor |
| 252 | Fifth Floor |
| 253 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washingetc. complete. For Flooring & Basement & Gr. Floor |
| 254 | First Floor |
| 255 | Second Floor |
| 256 | Third Floor |
| 257 | Fourth Floor |
| 258 | Fifth Floor |
| 259 | Providing andfixing in required positionskirting or dado of polishedKotahStone slab25 mm to 30mm thickfixedonbase onplasterofcementmortar 1:4including cementfloat, filling joints with cement slurry, curing rubbing, polishing and cleaning complete & Basement & Gr. Floor |
| 260 | First Floor |
| 261 | Second Floor |
| 262 | Third Floor |
| 263 | Fourth Floor |
| 264 | Fifth Floor |
| 265 | Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete & Basement & Gr. Floor |
| 266 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete & Basement & Gr. Floor |
| 267 | First Floor |
| 268 | Second Floor |
| 269 | Third Floor |
| 270 | Fourth Floor |
| 271 | Fifth Floor |
| 272 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete & Basement & Gr. Floor |
| 273 | First Floor |
| 274 | Second Floor |
| 275 | Third Floor |
| 276 | Fourth Floor |
| 277 | Fifth Floor |
| 278 | Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixingofstoneasperdrawinganddesign,includingcleaning,washingandfinishingetc. complete & First Floor |
| 279 | Second Floor |
| 280 | Third Floor |
| 281 | Fourth Floor |
| 282 | Fifth Floor |
| 283 | Providingandfixingmachinecutmirrorpolished18mm to20mm thicktelephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc.complete . Both side polish & First Floor |
| 284 | Second Floor |
| 285 | Third Floor |
| 286 | Fourth Floor |
| 287 | Fifth Floor |
| 288 | Providingandapplyingprimingcoatonconcrete/masonary/AsbestosCementplastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. & Basement & Gr. Floor |
| 289 | First Floor |
| 290 | Second Floor |
| 291 | Third Floor |
| 292 | Fourth Floor |
| 293 | Fifth Floor |
| 294 | Providing and applying washable oil-bound distemper of approvedcolour andshade to old andnewsurfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete & Basement & Gr. Floor |
| 295 | First Floor |
| 296 | Second Floor |
| 297 | Third Floor |
| 298 | Fourth Floor |
| 299 | Fifth Floor |
| 300 | Providing andapplying 2 coats of 100% Pure acrylic low VOCandAPEO& HCHOfree waterbasedpaintofapprovedcolourthatbelongstoclass1flamespreadresistanceof approvedmake Paint should provide durable and long lasting silk finish witha highcrack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria andfungus. Painthas tobe appliedon smoothanduniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed withwater based low VOC Primer. The work activity shouldcover all aspects of applying paints from surface preparation as directed by Engineer in charge & Basement & Gr. Floor |
| 301 | First Floor |
| 302 | Second Floor |
| 303 | Third Floor |
| 304 | Fourth Floor |
| 305 | Fifth Floor |
| 306 | Providingandapplying antipeelpaintofapproved make& approvedbrandexterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (HeatReflective Paint) & Basement & Gr. Floor |
| 307 | First Floor |
| 308 | Second Floor |
| 309 | Third Floor |
| 310 | Fourth Floor |
| 311 | Fifth Floor |
| 312 | Providing and applying Dezzly texture paint of Hammer / Screetech on the external plastered surface of approved quality.As directed by Engineer in charge ( Approved by SE PWC Nanded ) & Basement & Gr. Floor |
| 313 | First Floor |
| 314 | Second Floor |
| 315 | Third Floor |
| 316 | Fourth Floor |
| 317 | Fifth Floor |
| 318 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist & Fourth Floor |
| 319 | Fifth Floor |
| 320 | Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete & Basement & Gr. Floor |
| 321 | First Floor |
| 322 | Second Floor |
| 323 | Third Floor |
| 324 | Fourth Floor |
| 325 | Fifth Floor |
| 326 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete & Basement & Gr. Floor |
| 327 | First Floor |
| 328 | Second Floor |
| 329 | Third Floor |
| 330 | Fourth Floor |
| 331 | Fifth Floor |
| 332 | Providing and fixing Country teak wood Four leafpaneled shutters, 35 mm thick style and railand25mm thickpanelswithoutventilatorasperdetaileddrawingexcluding thedoor frame, stainless steelfixtures and fastening and finishing the wood work with oil painting 3 coats complete & Basement & Gr. Floor |
| 333 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panelswithoutventilatorasperdetaileddrawingexcludingthedoorframe,stainlesssteel fixtures and fastening and finishing the wood work with oil painting 3 coats complete & Basement & Gr. Floor |
| 334 | First Floor |
| 335 | Second Floor |
| 336 | Third Floor |
| 337 | Fourth Floor |
| 338 | Fifth Floor |
| 339 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. & Basement & Gr. Floor |
| 340 | First Floor |
| 341 | Second Floor |
| 342 | Third Floor |
| 343 | Fourth Floor |
| 344 | Fifth Floor |
| 345 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete & Basement & Gr. Floor |
| 346 | First Floor |
| 347 | Second Floor |
| 348 | Third Floor |
| 349 | Fourth Floor |
| 350 | Fifth Floor |
| 351 | Providing and fixing Godrej make door for strong room. Class II defender with grill,gate with necessary filling as per std.Complete. |
| 352 | Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator includingchromium plated fixtures and fastening with chromium plated handles on both sides, etc complete Basement & Gr. Floor |
| 353 | First Floor |
| 354 | Second Floor |
| 355 | Third Floor |
| 356 | Fourth Floor |
| 357 | Fifth Floor |
| 358 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two trackswithrectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/One Running Metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box & Basement & Gr. Floor |
| 359 | First Floor |
| 360 | Second Floor |
| 361 | Third Floor |
| 362 | Fourth Floor |
| 363 | Fifth Floor |
| 364 | Providing andfixing inposition(asper1868/1982)Aluminium sliding windowofthree tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight 0.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With powder coating with box & Basement & Gr. Floor |
| 365 | Basement & Gr. Floor |
| 366 | First Floor |
| 367 | Second Floor |
| 368 | Third Floor |
| 369 | Fourth Floor |
| 370 | Fifth Floor |
| 371 | SlidingWindow-3Track(2Glassshutter+1flymesh)ofapprovedmakewithDGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge & Basement & Gr. Floor |
| 372 | First Floor |
| 373 | Second Floor |
| 374 | Third Floor |
| 375 | Fourth Floor |
| 376 | Fifth Floor |
| 377 | a) Supplying and fixing in position Aluminium four track sliding windows with outer frame madefrom section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre andtop andside section of size 122x 31.75 mm weighing 1.15Kilogramper One Running Metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper One Running Metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainlesssteelmosquitonetinone (2/3 ofopening) panelfixed withnew neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete & Basement & Gr. Floor |
| 378 | First Floor |
| 379 | Second Floor |
| 380 | Third Floor |
| 381 | Fourth Floor |
| 382 | Fifth Floor |
| 383 | Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete & Basement & Gr. Floor |
| 384 | First Floor |
| 385 | Second Floor |
| 386 | Third Floor |
| 387 | Fourth Floor |
| 388 | Fifth Floor |
| 389 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/candfixing inwallwith6Nosofholdfastof12mm diabars500mm longincluding primer and oil painting etc, complete) frame size 60 mm x 100 mm & Fourth Floor |
| 390 | Fifth Floor |
| 391 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete & Basement & Gr. Floor |
| 392 | First Floor |
| 393 | Second Floor |
| 394 | Third Floor |
| 395 | Fourth Floor |
| 396 | Fifth Floor |
| 397 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75mmdiameteretc.complete(PriorapprovalofsampleandbrandbyEx.Engineeris necessary before use) & Basement & Gr. Floor |
| 398 | First Floor |
| 399 | Second Floor |
| 400 | Third Floor |
| 401 | Fourth Floor |
| 402 | Fifth Floor |
| 403 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BARof IZE-600MM (H) X600MM (D) and 32MM DIA. and thicknessmm of the approved brand and make.27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make & Basement & Gr. Floor |
| 404 | First Floor |
| 405 | Second Floor |
| 406 | Third Floor |
| 407 | Fourth Floor |
| 408 | Fifth Floor |
| 409 | Providing andfixing shutter to wall cupboard made from 19 mm thick Teak particle board withapprovedcolouredlaminatedface1.5mmthickbondedwithphenolformaldehyde synthetic resin B.W.P. grade including lipping beading iron oxidisedfixtures andfastening and oil primer coat etc. complete. (Excluding cupboard frame) & First Floor |
| 410 | Second Floor |
| 411 | Third Floor |
| 412 | Fourth Floor |
| 413 | Fifth Floor |
| 414 | ProvidingandfixingC.P.2WayBIBcockwithwallflange ofapproved makeincluding necessary sockets/ union nut etc. complete as directed by Engineer in charge & Basement & Gr. Floor |
| 415 | First Floor |
| 416 | Second Floor |
| 417 | Third Floor |
| 418 | Fourth Floor |
| 419 | Fifth Floor |
| 420 | Providing andfixing 25mm diameterwatermeterwithnon-returnvalve includingstrainer, sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock. [Without chamber] & Basement & Gr. Floor |
| 421 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete & Basement & Gr. Floor |
| 422 | First Floor |
| 423 | Second Floor |
| 424 | Third Floor |
| 425 | Fourth Floor |
| 426 | Fifth Floor |
| 427 | Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete & Basement & Gr. Floor |
| 428 | First Floor |
| 429 | Second Floor |
| 430 | Third Floor |
| 431 | Fourth Floor |
| 432 | Fifth Floor |
| 433 | Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete & Basement & Gr. Floor |
| 434 | First Floor |
| 435 | Second Floor |
| 436 | Third Floor |
| 437 | Fourth Floor |
| 438 | Fifth Floor |
| 439 | Providingandfixingpushcock(Selfclosingtap)symettypeof15mmdia. including necessary socket, testing etc. complete & Basement & Gr. Floor |
| 440 | First Floor |
| 441 | Second Floor |
| 442 | Third Floor |
| 443 | Fourth Floor |
| 444 | Fifth Floor |
| 445 | ProvidingandfixingWhiteglazedwithbottletrap earthenwareWashHandBasinof 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe andtrapuptotheoutsidefaceofthewall,makinggoodthedamagedsurface,testingetc. complete & Basement & Gr. Floor |
| 446 | First Floor |
| 447 | Second Floor |
| 448 | Third Floor |
| 449 | Fourth Floor |
| 450 | Fifth Floor |
| 451 | Providing and fixingOval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm sizewith pillarcock,C.P.Angularstopcock,longthreadofapprovedmakecontinental includingSSbottletrapof necessarypipeconnectionuptotheoutsidefaceofthewall, havingTelephonicBlack/ColourGraniteof180mmthickfixedonBlackKadappa Framework, etc. Complete as directed by Engineer in charge & First Floor |
| 452 | Second Floor |
| 453 | Third Floor |
| 454 | Fourth Floor |
| 455 | Fifth Floor |
| 456 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap & Basement & Gr. Floor |
| 457 | Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete & Basement & Gr. Floor |
| 458 | Providing andlaying for 150 mm dia salt glazedstoneware pipe including fittings Suchas bends,tees,singlejunction,doublejunctionslaying,jointing(includingexcavationand refilling the trenches) complete & Basement & Gr. Floor |
| 459 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete & Basement & Gr. Floor |
| 460 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete & Basement & Gr. Floor |
| 461 | Providing , constructing and fixing600 mm dia. Inspection chamber made up of Polypropylene/polyethylenematerialHaving315mmdiameterinlet(s)/outletsandwith eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of5mmand600mminheight,withinbuiltshaftachievetheinvertdepthaspersite condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete & Basement & Gr. Floor |
| 462 | Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete & Basement & Gr. Floor |
| 463 | First Floor |
| 464 | Second Floor |
| 465 | Third Floor |
| 466 | Fourth Floor |
| 467 | Fifth Floor |
| 468 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete & Basement & Gr. Floor |
| 469 | First Floor |
| 470 | Second Floor |
| 471 | Third Floor |
| 472 | Fourth Floor |
| 473 | Fifth Floor |
| 474 | Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold waterchromium platedscrewdownbibtap,rolledsteelorC.I.brackets,rubberplugwith chain and stop tap complete. & Basement & Gr. Floor |
| 475 | First Floor |
| 476 | Second Floor |
| 477 | Third Floor |
| 478 | Fourth Floor |
| 479 | Providingandfixingstainlesssteelsinkofsize600x510x200mm incluidngcoupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete & First Floor |
| 480 | Second Floor |
| 481 | Third Floor |
| 482 | Fourth Floor |
| 483 | Fifth Floor |
| 484 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete Basement & Gr. Floor |
| 485 | First Floor |
| 486 | Second Floor |
| 487 | Third Floor |
| 488 | Fourth Floor |
| 489 | Fifth Floor |
| 490 | ProvidingandfixingC.P.pillarcocklongneckwithaeratorofapproedmakeincluding necessary sockets/union nut etc. complete & Basement & Gr. Floor |
| 491 | First Floor |
| 492 | Second Floor |
| 493 | Third Floor |
| 494 | Fourth Floor |
| 495 | Fifth Floor |
| 496 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete & Basement & Gr. Floor |
| 497 | First Floor |
| 498 | Second Floor |
| 499 | Third Floor |
| 500 | Fourth Floor |
| 501 | Fifth Floor |
| 502 | Providing and fixing C.P. sink cock with raised J\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\" & Basement & Gr. Floor |
| 503 | First Floor |
| 504 | Second Floor |
| 505 | Third Floor |
| 506 | Fourth Floor |
| 507 | Fifth Floor |
| 508 | Providing andfixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete & Fourth Floor |
| 509 | Fifth Floor |
| 510 | Providing andfixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete & Fourth Floor |
| 511 | Fifth Floor |
| 512 | Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalentmake including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) & Basement & Gr. Floor |
| 513 | First Floor |
| 514 | Second Floor |
| 515 | Third Floor |
| 516 | Fourth Floor |
| 517 | Fifth Floor |
| 518 | Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bendpipeandwallflangeofapprovedmakeincludingnecessarysockets/unionnutetc.complete. |
| 519 | First Floor |
| 520 | Second Floor |
| 521 | Third Floor |
| 522 | Fourth Floor |
| 523 | Fifth Floor |
| 524 | Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete &Basement & Gr. Floor |
| 525 | First Floor |
| 526 | Second Floor |
| 527 | Third Floor |
| 528 | Fourth Floor |
| 529 | Fifth Floor |
| 530 | Providing and fixingOrissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil andvent pipe upto outside face ofwall including 100mm dia.C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge & Basement & Gr. Floor |
| 531 | First Floor |
| 532 | Second Floor |
| 533 | Third Floor |
| 534 | Fourth Floor |
| 535 | Fifth Floor |
| 536 | ProvidingandfixingwhiteOpalseriesEuropean typewall-hung, ofsize 400 mm x 370 mm x 575mm with approved make flush valveincluding soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge & First Floor |
| 537 | Second Floor |
| 538 | Third Floor |
| 539 | Fourth Floor |
| 540 | Fifth Floor |
| 541 | Providingand fixingwhiteglazedurinal of size 710x460x300mmwith sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete & First Floor |
| 542 | Second Floor |
| 543 | Third Floor |
| 544 | Fourth Floor |
| 545 | Fifth Floor |
| 546 | Providingandfixing75mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. complete & Basement & Gr. Floor |
| 547 | First Floor |
| 548 | Second Floor |
| 549 | Third Floor |
| 550 | Fourth Floor |
| 551 | Fifth Floor |
| 552 | Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. complete & Basement & Gr. Floor |
| 553 | First Floor |
| 554 | Second Floor |
| 555 | Third Floor |
| 556 | Fourth Floor |
| 557 | Fifth Floor |
| 558 | Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete & Basement & Gr. Floor |
| 559 | Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such abends,tees,coupler,etc,jointingwith rubberlubricantincludingnecessary excavation, trench refilling with selective excavated materialetc. complete & Basement & Gr. Floor |
| 560 | Providing and fixing H.D.P container one piece moulded water tank made out oflowdensitypolythylerandbuiltcorrugationincludingofdeliveryuptodestination hoisting andfixing of accessories such as inlet, outlet overflow of alltanks capacityabove 1000 to 20,000 litres & Fifth Floor |
| 561 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 562 | First Floor |
| 563 | Second Floor |
| 564 | Third Floor |
| 565 | Fourth Floor |
| 566 | Fifth Floor |
| 567 | Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 568 | First Floor |
| 569 | Second Floor |
| 570 | Third Floor |
| 571 | Fourth Floor |
| 572 | Fifth Floor |
| 573 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 574 | First Floor |
| 575 | Second Floor |
| 576 | Third Floor |
| 577 | Fourth Floor |
| 578 | Fifth Floor |
| 579 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 580 | First Floor |
| 581 | Second Floor |
| 582 | Third Floor |
| 583 | Fourth Floor |
| 584 | Fifth Floor |
| 585 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. & Basement & Gr. Floor |
| 586 | First Floor |
| 587 | Second Floor |
| 588 | Third Floor |
| 589 | Fourth Floor |
| 590 | Fifth Floor |
| 591 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete & Basement & Gr. Floor |
| 592 | First Floor |
| 593 | Second Floor |
| 594 | Third Floor |
| 595 | Fourth Floor |
| 596 | Fifth Floor |
| 597 | Providingandfixing15cmrigidPVCNahanitrapincludingPVCgrating ,bend,connectingpieceofUPVCpipeuptotheoutsidefaceofwall,makingthegood damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Basement & Gr. Floor |
| 598 | First Floor |
| 599 | Second Floor |
| 600 | Third Floor |
| 601 | Fourth Floor |
| 602 | Fifth Floor |
| 603 | ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete Basement & Gr. Floor |
| 604 | First Floor |
| 605 | Second Floor |
| 606 | Third Floor |
| 607 | Fourth Floor |
| 608 | Fifth Floor |
| 609 | Providingandlayingintrenches15mmdai.CPVCpipeincludingnecessaryexcavation, fittings.Refillingtrenchesetc.completeIncluding removingexisting pipeline ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 610 | Providingandlayingintrenches20mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 611 | Providingandlayingintrenches25mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete Basement & Gr. Floor |
| 612 | Providingandlayingintrenches32mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 613 | Providingandlayingintrenches40mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete. & Basement & Gr. Floor |
| 614 | Providingandlayingintrenches50mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete & Basement & Gr. Floor |
| 615 | Providing andfixing in positionUPVC ultra violet stabilized110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete & Fifth Floor |
| 616 | Providing andfixing Glassself 125mm wide and600mm long withnecessary chromium plated brackets providing T.W.gutties etc. complete Basement & Gr. Floor |
| 617 | First Floor |
| 618 | Second Floor |
| 619 | Third Floor |
| 620 | Fourth Floor |
| 621 | Fifth Floor |
| 622 | Supplying and erecting Automatic Sanitizer Dispenser body size (450mmx300mmx220mm), Wall Mounted With 5Liters Capacity of Sanitization Liquid Container and Operation type (Automatic / Touchless), Sensor type motions senser, Voltage-220V,50Hz, for power consumtion(idel mode)-<3VA and (operation mode) -25A, (MOC-Acrylonitrile butadiene styrene (ABS), Polypropylene (PP), brass), with 6 months waranty against manufacturing defects& Basement & Gr. Floor |
| 623 | First Floor |
| 624 | Second Floor |
| 625 | Third Floor |
| 626 | Fourth Floor |
| 627 | Fifth Floor |
| 628 | Providingand fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete & Basement & Gr. Floor |
| 629 | First Floor |
| 630 | Second Floor |
| 631 | Third Floor |
| 632 | Fourth Floor |
| 633 | Fifth Floor |
| 634 | Providing andfixinglioghtening conductorsystem comprisingoferecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long(HeavyDuty)welded orclampedtoG.I.pipepoleBgrade50mm diaofrequiired lengthwithM.S.roundbnaseplate25Cmdiamand10mmthickatbottomembededin cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing withcopperearthplateofsize60x60x0.3cmswithcadmiumplatednutboltstofix earthingstripburriedinspeciallypreparedearthpits1.5metrebelowgroundlevelwith 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for wateringandrefillingcomcpeteNote-Copperstripfropmlighteningconductorisnot considered in this item. & Basement & Gr. Floor |
| 635 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfaceareacovering10yearsguaranteeon bond paper.& Basement & Gr. Floor |
| 636 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)treatmentby treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos perOne Square Metre of vertical surface area covering 10 years guarantee on bond paper. & Basement & Gr. Floor |
| 637 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper & Basement & Gr. Floor |
| 638 | Providingandfixing90cmx60cm Graniteplateengraving10cm.Height letter,figures including painting the lefters/figures with approved colour and shade complete & Basement & Gr. Floor |
| 639 | Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) & Basement & Gr. Floor |
| 640 | First Floor |
| 641 | Second Floor |
| 642 | Third Floor |
| 643 | Fourth Floor |
| 644 | Fifth Floor |
| 645 | Providing and fixing sky light in R.C.C. roof including frame made of M.S. angle 50 x 50 x 6 mm with hold fast, sheet glass 12 mm thick, Chicken mesh 24 gauge with all accessories and required fixtures and fastening fitting including painting etc. complete & Fourth Floor |
| 646 | Fifth Floor |
| 647 | Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs. & Fifth Floor |
| 648 | Providingsoakpitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats & Basement & Gr. Floor |
| 649 | RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushedsandVSIgradefinelywashedetc.)includingnetlonmeshbetweeneach gravel/fine aggregate (naturalsand/crushedsandVSI grade finely washedetc.) medialayer includingcoveringwithRCCslab,manholeframe&cover,PVCrungsetc.including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rateshallbeinclusiveofalllabour,material,wastage,scaffolding,transportation,taxes, includingallleads,liftsatalllevels.Allmaterialshouldbeofapprovedmake.Allworks complete as per the drawing, technical specification and direction of the Engineer in charge & Basement & Gr. Floor |
| 650 | Boring/drillingborewellof300mmdiaforcasing/strainerpipe,bysuitablemethod prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing andsubmittingstratachart/borelog,includinghire&runningchargesofallequipments, tools, plants & machinery required for the job, all complete as per directionof Engineer in charge, upto 90m depth below ground level. Basement & Gr. Floor |
| 651 | Supplying,assembling,loweringandfixinginverticalpositioninborewell,unplasticized PVCmedium well-casingpipe of150mm dia,conforming toIS:12818,includingrequired hireandlabourcharges,fittings&accessoriesetc.allcomplete,foralldepths,asperthe direction of Engineer in charge & Basement & Gr. Floor |
| 652 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester.Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33%Percentage of polyester resin: - 66.67%Water absorption (as per ASTM):-0.30%Flammability as per ASTMTensile strength:-115 MPASpecific Gravity at 25 degree centigrade 1.45Izod impact strength:-65KJ/M2Heat defection/distort temperature:-65deg CCorrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mmOutlet pipe size rigid PVC:-80mmGas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition)With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.5mx1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria iNosculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Spec. Nos. As directed by Engineer in Charge. SSR I.Nos.51.112, P.Nos.380 & Basement & Gr. Floor |
| 653 | Basement & Gr. Floor |
| 654 | ProvidingandFixingof MineralFibreBoardAcousticalSuspendedCeilingSystemwith ultima(BevelledTegular)Edge Tilesofsize 15mm ExposedGRID.The tilesshouldhave Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel onXL2 Clip having a web height of 32 mm with15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm anda load carrying capacity of 7.7 Kilograms/M2 andminimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete & Basement & Gr. Floor |
| 655 | First Floor |
| 656 | Second Floor |
| 657 | Third Floor |
| 658 | Fourth Floor |
| 659 | Fifth Floor |
| 660 | Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.)4 no each leaf,with Door-closer (Dorma / Geze or eq.)including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete & First Floor |
| 661 | First Floor |
| 662 | Second Floor |
| 663 | Third Floor |
| 664 | Fourth Floor |
| 665 | Providingandfixingboarddisplayinginformation,suchas\"Nameofwork,Tendercost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x75cmincluding,excavation,refilling,transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge & Basement & Gr. Floor |
| 666 | Providing and supplying in standard lengthsH.D.PolyethelenePipes,confirming to IS 4984/14151/12786/13488 with nesessary jointing material like mechanical connector i.e.thread/insert joint/quick release coupler joint/compression fitting jointor flanged joint excluding coupler/specials,including transportation and freight charges,inspection charges,loading/unloading charges,conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains,excluding GST levied by GI & GOM in all respectetc.complete.As per IS:4984-2016 (HDPE Pipes upto 110mm dia. shall be in coil form). Spec. Nos. As directed by Engineer in Charge |
| 667 | Providing the consultancy services for GRIHA certification of the building, including all related expenses in achieving Green certification, including all lead, lift and taxes; excluding GST, including conducting all awareness program during inception till the receipt of GRIHA certification and even during 2 years of defect liability period; including the fees for training programme, excluding the fee for statutory requirements and GRIHA certificationwhich will be paid by P.W. Dept. & Site visit piad by the contractor , including all related to the achivement of the GRIHA certification etc. complete and as directed by engineer-in-charge. (For total built up aera of project ) a) Payment Termsb) Feasibility study and First TrainingC) Simulation exerciseEnergy and Daylightd) Submission of Compliace of second site visitand second training for vosite) Submission of document of GRIHAf) Receipt of provisional GRIHA Certification |
| 668 | Engaged Computer Opreter for project work (SSR 2022-23 Pno 546 Sr No.81 Supply Item) |
| 669 | Engaged Assistant for project work (SSR 2022-23 Pno 546 Sr No.78 Supply Item) |
| 670 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete. |
| 671 | Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 672 | Dismantlingbrickmasonryinlimeorcementmortarandstackingthematerilsasdirected with all leads, lifts etc. |
| 673 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 674 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceableandunserviceablematerials,stackingthesameasandwheredirectedinthe compound including scaffolding etc. complete. |
| 675 | Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8 A boards etc and sacking the materials as directed with all leads andlifts complete. Including removing wood work below etc. complete. |
| 676 | Removinglimeorleancementconcreteincludingstackingthespoilsasdirectedwithall leads, lifts etc, complete. |
| 677 | Dismantling stone masonry in Mud including stacking the materials as directed with all leads, lifts etc. complete. |
| 678 | Removingbattensfromroofandstackingthemasdirectedwithallleadsandliftsetc. complete. |
| 679 | Removing purlins from roof including stackingas directed with all leads , lifts etc. complete. |
| 680 | Removingraftersfromroofincludingthematerials asdirectedwithallleads ,liftsetc. complete. |
| 681 | Removingothertype trussbelow5metresspanfromroofandstackingthematerialsas directed with all leads and lifts etc. complets |
| 682 | Removing cast iron or wrought iron or A.C. pipeand stacking them as directed with all leads, lifts etc. complete. |
| 683 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 684 | Providing Electrical Installation to New Building (Basement G 5) of District Court at BULDHANA. 11 K VV C.B., H.T. CABLES and TERMINATION KITS Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 1 way indoor/outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 VCBompliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA |
| 685 | Supplying and erecting HT CT multifunction DLMS compliance of accuracy of class 0.5 , 3x63.5V,50 Hz with optical & RS 232 port, backlit LCD, measures kWh, kVAh, V, I, kW, 6 months history of energy , load survey, & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box. |
| 686 | Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. |
| 687 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 688 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 689 | Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 690 | Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP |
| 691 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 400 kVA, natural ester oil and naturally cooled Indoor type, Copperwound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating, using type class B type insulation (thermally upgraded paper (TUP) with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2790 Watts at 50% load, 7700 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL |
| 692 | MAIN PANEL, BACKUP PANEL, DIESEL GENERATOR, APFC Supplying, installation, testing & commissioning of MAIN PANEL of Type Tested Assembly type as per specifications of IEC 61439 and as per provided SLD :-i) Incomer shall have Multifunction meter 0.5 Class with V,A,F,PF,kVA,kW,kVAr,kWh,kVAh,kVArh,all type hours, THD, events, Neutral current & RS 485 port. Incomer shall have type I S.P.D. with MCB and ELR with CBCT.ii) All CTs to be resin cast.iii) All Outgoings to have Digital Energy Meters.iv) Other details as mentioned in SLD.v) Incomer will have 630A 4P MCCB and additional CT for APFC and another additional CT for SVG + AHF.vi) Fixed capacitor of 3 kVAr with 7% detuned Copper reactor of 1.8 x Ir along with 16A TP C-class MCB.vii) Outgoings will be 400A TP 36kA MCCB -1 no., 315A TP 36kA MCCB -1 no., 250A TP 25kA MCCB -1 no., 200 TP 25kA MCCB -1 no., 160A TP 25kA MCCB -1 no., 125A TP 25kA MCCB -1 no., 100A TP 25kA MCCB -2 no. |
| 693 | Supplying, installation, testing & commissioning of MAIN BACKUP POWER PANEL of Type Tested Assembly type as per specifications of IEC 61439 and as per provided SLD :-i) Incomer shall have Multifunction meter 0.5 Class with V,A,F,PF,kVA,kW,kVAr,kWh,kVAh,kVArh,all type hours, THD, events, Neutral current & RS 485 port. Incomer shall have type I S.P.D. with MCB and ELR with CBCT. ii) All CTs to be resin cast.iii) All Outgoings to have Digital Energy Meters.iv) Other details as mentioned in SLD.v) Incomer will have 315A 4P MCCB.vi) Outgoings will be 315A TP 36kA MCCB -2 no., 200 TP 25kA MCCB -1 no., 160A TP 25kA MCCB -2 no., 125A TP 25kA MCCB -1 no., 100A TP 25kA MCCB -3 no. |
| 694 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 695 | Supplying and erecting 125 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC |
| 696 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 180 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 54.89 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/ cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 480 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG |
| 697 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 140 kVA up to 180 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 698 | ROOFTOP SOLAR PV SYSTEM Supplying, installing, testing and commissioning of 150 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG(Approx. 1125 Sq. Mtr. PV Module area). |
| 699 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 700 | Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 701 | Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 702 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 703 | Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP |
| 704 | POINT WIRING, LIGHTS & FANS FOR ELECTRICAL ROOMS, UPS, CAR CHARGER. Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 705 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 706 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 707 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 708 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 709 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 710 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 711 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 712 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 713 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 714 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 715 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 716 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 717 | Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 718 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 719 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 720 | Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 721 | Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 722 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 723 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 724 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 725 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 726 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 727 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 728 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 729 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 730 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 731 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 732 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 733 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW |
| 734 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW |
| 735 | Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW |
| 736 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW |
| 737 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 738 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 739 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 740 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 741 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 742 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 743 | Supplying and erecting double suspension pipe rod of 16 gauge 20mm.dia H.G. conduit duly threaded and painted with two coats of enamel paint for erection of fluo. tube light fitting with necessary check nuts and shielded copper flexible wire three core of 1 sq mm for connecting leads (for measurementshalfofthe actuallength bothpipes used) |
| 744 | Supplying and erecting ball suspension plate cast aluminium erected with spring on wooden block in position. |
| 745 | Supplying and erecting bakelite call bell with 6 cm / buzzer with double coil suitable for 230V complete erected on PVC block. |
| 746 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 747 | Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 748 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 749 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 750 | Supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kWh / 24 hour / 45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH |
| 751 | Providing fiber reinforced PVC flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. |
| 752 | Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of HALF hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 753 | Supplying, erecting, testing and commissioning of 6kVA capacity online pure sine wave with backup time of HALF hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 754 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 755 | Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehicle charger (suitable for 4 wheeler) having minimum IK08 & IP54 protection suitable for single phase, 230V AC, 50Hz, incoming and 1 nos. output having capacity of output current of 32A at 230V with Type two connector as per IEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cable length, 3.5\" TFT screen for human interface & LED light for status indication and metering for measurement of consumed energy having metering accuracy +/- 1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application /QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload, earth leakage ,Over temperature, surge protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification |
| 756 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 757 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 758 | Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 759 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 760 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 761 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 762 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. |
| 763 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 764 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 765 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 766 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 767 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB |
| 768 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 769 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 770 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 771 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 772 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 773 | Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 774 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 775 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 776 | Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 777 | Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 778 | Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 779 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 780 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 781 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 782 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 783 | AIR INSULATED BUS BAR TRUNKING SYSTEM Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification |
| 784 | Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 160A Capacity at 40oC ambient temperature Air Insulated type Bus Trunking Aluminium Conductor having purity not less than 99.6% with Tin plated at joints suitable for (3L+N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54 Protection, 15KA short circuit rating for 0.1sec, Insulation Class F (155 C), casing made of Galvanized/ powder coated steel sheet enclosure having Mechanical strength certification up to IK10, with required shade of paint & having cross sectional area not more than 0.0150 Sq m, complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with , outlet cover, plug in hole as per site requirement with Horizontal / Vertical G.I. Support at required interval with External Single Run 25x10mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification |
| 785 | Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 400A Capacity at 40C ambient temperature Air Insulated type Bus Trunking Aluminium Conductor having purity not less than 99.6% with Tin plated at joints suitable for (3L+N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosures as integral earth (PE) BBT Shall type tested as per IEC 61439-6 with IP 54 Protection, 25KA short circuit rating for 1sec, Insulation Class F (155 C), casing made of Galvanized / powder coated steel sheet enclosure having Mechanical strength certification up to IK10, with required shade of paint & having cross sectional area not more than 0.0270 Sq m, complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with , outlet cover , plug in hole as per site requirement with Horizontal / Vertical G.I. Support at required interval, with External Single Run 25x10mm Aluminium earthing strip or Internal Integral Earthcomplete confirming to IEC 61439-6 as per specification |
| 786 | Supplying, installation, testing and commissioning of Flange end as per design requirement & site condition suitable for Aluminium 160A, 3 phase 4 wire 415V, 50 Hz A.C ,15kA short circuit rating for 0.1 sec, for Air Insulated type BBT. With necessary accessories complete confirming to IEC 61439-6 as per specification |
| 787 | Supplying, installation, testing and commissioning of Flange end as per design requirement & site condition suitable for Aluminium 400A, 3 phase 4 wire 415V, 50 Hz A.C ,25kA short circuit rating for 1 sec for Air Insulated type BBT. With necessary accessories complete confirming to IEC 61439-6 as per specification |
| 788 | Supplying, installing & Commissioning Vertical or Horizontal 90 Degree/Tee Elbow for Air Insulated type bus trunking/ rising mains of capacity 160A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,15kA short circuit rating for 1 sec Made Galvanised sheet metal enclosure (IP54) duly powder coated with all necessary accessories completeconfirming to IEC 61439-6 as per specification. |
| 789 | Supplying, installing & Commissioning Vertical or Horizontal 90 Degree/Tee Elbow for Air Insulated type bus trunking/ rising mainsof capacity 400A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,25kA short circuit rating for 1 sec Made Galvanised sheet metal enclosure (IP54) duly powder coated with all necessary accessories completeconfirming to IEC 61439-6 as per specification. |
| 790 | EARTHING AND LIGHTNING PROTECTION Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/ CU [ for 2 nos. earthing each of Server Room, Security Room & CCTV Room ] |
| 791 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 792 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA (For Metering Cubicle Earthing). |
| 793 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP (For Metering Cubicle Earthing). |
| 794 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 795 | STREET LIGHTING POLES, DB & CABLING Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 796 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation. |
| 797 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 798 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 799 | Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPEarmouredcable on wall/poleas per specification no. CB-CE |
| 800 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 801 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 802 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 803 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 804 | MISCELLANEOUS ITEMS Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 |
| 805 | Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982 |
| 806 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. |
| 807 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete. |
| 808 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV |
| 809 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail