Tender For Repair Maint Of Lt Elect Installation Oh Line Lt Ug Cable And Fire Fighting Equipments At Map Area P 21 And Connected Works At Sevoke Mil Stn Under Ge Sevoke Road, Kalimpong-West Bengal

Military Engineer Services-MES has published Tender For Repair Maint Of Lt Elect Installation Oh Line Lt Ug Cable And Fire Fighting Equipments At Map Area P 21 And Connected Works At Sevoke Mil Stn Under Ge Sevoke Road. Submission Date for this Tender is 10-07-2023. Fire Fighting Consumable Tenders in Kalimpong West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37980415
Corrigendum : Tender For Repair Maint Of Lt Elect Installation Oh Line Lt Ug Cable And Fire Fighting Equipments At Map Area P 21 And Connected Works At Sevoke Mil Stn Under Ge Sevoke Road
Open Tender
Indian
West Bengal
Kalimpong
10-07-2023

Tender Details

Repair Maint Of Lt Elect Installation Oh Line Lt Ug Cable And Fire Fighting Equipments At Map Area P 21 And Connected Works At Sevoke Mil Stn Under Ge Sevoke Road

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jun-2023 PRODUCTCORRIGENDUM Other 24-06-2023
2 13-Jun-2023 BOQCORRIGENDUM BOQ 24-06-2023
3 15-Jun-2023 PRODUCTCORRIGENDUM1 Other 24-06-2023
4 24-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-07-2023
5 01-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-07-2023
6 06-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

Name of Work: REPAIR MAINT OF LT ELECT INSTALLATION OH LINE LT UG CABLE AND FIRE FIGHTING EQUIPMENTS AT MAP AREA P 21 AND CONNECTED WORKS AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
Sl. No. Item Description
1Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr deep for foundation, laying GI pipes and UG cables etc n exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed.
2Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil in getting out and levelling of bottom surface to required level for cable/stay all as directed.
3Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
4Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
5S & F 50 mm dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
6S & F 75 mm dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
7M & L GI tubing 80 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor complete all as specifed and directed.
8M & L GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor complete all as specifed and directed.
9M & L GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor complete all as specifed and directed.
10Supply, laying XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable withstranded aluminumconductor 1100 volt grade of size 185 Sqmm 3.5 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed including taking down old unserviceable XLPE cable with brick protection andcomplete all as specified and as directed.
11All as per item No 10 above but 150sqmm, 3.5 core all as specified.
12All as per item No 10 above but 120sqmm, 3.5 core all as specified.
13All as per item No 10 above but 95sqmm, 3.5 core all as specified.
14All as per item No 10 above but 70sqmm, 3.5 core all as specified.
15All as per item No 10 above but 60sqmm, 3.5 core all as specified.
16All as per item No 10 above but 25sqmm,4 core all as specified.
17All as per item No 10 above but 16sqmm,4 core all as specified.
18All as per item No 10 above but 10sqmm,4 core all as specified.
19All as per item No 10 above but 16sqmm,2 core all as specified.
20S&F Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31( 9 metre long) including taking down old unserviceable RCC poles complete all as specified and directed.
21S & F cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 to 185Sqmm, indoor/outdoor type including taking out & relaying damaged cable after repair complete all as specified and as directed. (Excavation and connected items will be measured and paid separately.)
22S&F cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 50Sqmm, indoor/outdoor type including taking out & relaying damaged cable after repair complete all as specified and as directed. (Excavation and connected items will be measured and paid separately.)
23S&F GI strip 32 x 6 mm as eath continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etcincluding dismantling old unserviceable strip complete all as specified and directed.
24M&L PCC (1:3:6) type C1 (using 20mm graded stone aggregates) as in coping of poles including demolition of old damaged concrete from pole formwork complete all as specified and as directed
25M&L PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in PCC/Road cutting /installation area and foundation of pole etccomplete all as specified and as directed.
26M&L for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
27S&F in repair Indicator lamp (AC/DC), LED, type for as per existing fitting.complete all as specified and as directed.
28S&F in repair 3 Phase LED Ammetercomplete all as specified and as directed.
29S&F in repair, 3 phase LED Voltmeter complete all as specified and as directed.
30Supply and fix as in repairsMCCB four pole , 415 Volt, 63 Amps,16 KA , fixed thermal &magnetic setting complete all as specified and directed .
31Supply and fix as in repairsMCCB four pole , 415 Volt, 100 Amps,16 KA , fixed thermal &magnetic setting complete all as specified and directed .
32Supply and fix as in repairsMCCB four pole , 415 Volt, 125 Amps,16 KA , fixed thermal &magnetic setting complete all as specified and directed
33S&F MCCB, 160 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed.
34S&F MCCB, 200 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed.
35S&F MCCB, 250 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed.
36S&F MCCB, 400 Amps, 4P, 36 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed
37M&L for pipe earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron strip of size 25x4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washers of galvanised iron including PCC (1:2:4) type B-1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia mediaum grade galvanised steel tube for watering with one and fix with cast iron funnel and wire-mesh, with protection pipe of 32mm dia light grade galvanised steel tubing upto 7.5 meters length for drawing earthlead with filling of bentonite in 600mm dia all around electrode etc, completeincluding testing on completion andincluding taking down old U/S earthing& testing complete all as specified and as directed.
38M&L for pipe earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron wire of size 4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washers of galvanised iron including PCC (1:2:4) type B-1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia mediaum grade galvanised steel tube for watering with one and fix with cast iron funnel and wire-mesh, with protection pipe of 32mm dia light grade galvanised steel tubing upto 7.5 meters length for drawing earthlead with filling of bentonite in 600mm dia all around electrode etc, completeincluding testing on completion andincluding taking down old U/S earthing& testing complete all as specified and as directed.
39M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
40Supply and fixing thermoplastic polycarbonate cable junstion box having protection IP 66"dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 16 sqmm and 155x210x92mm with terminals, brackets for street light pole mounting and provision of one 6A MCB SP all as specified and as directed.
41M & L painting LT Panel/feeder pillar by 2 coats of synthetic enamel paint after preparation of surfaces with sand paper complete all as specified and as directed.
42Servicing of LT Panel after shut downand removing all dust particles and proper layout of LT panel wlth gland packing including 2.5 sqmm copper single core copper cable including repairing/replacing door hinges/door lock etc for necessary connections complete all as specified and directed
43M & L for Preparation of metalic surface with sand paper for street light pole and other steel surface complete all as specified and as directed .
44M & L for red oxide zinc chrome of metalic surface for street light pole and other steel surface complete all as specified and as directed.
45M & L for aluminium paint 2 coats of metalic surface for street light pole and other steel surface complete all as specified and as directed .
46M & L for Yellow/black paint 2 coats of metalic surface complete all as specified and as directed.
47M & L for Preparation of Cement surface with sand paper forpole and other cement surface complete all as specified and as directed
48M & L for exterior priming paint plaster coat suitable for cement surface forpole and othersurfacecomplete all as specified and as directed.
49M & L for weather coat emulsion paint 2 coats of Cement surface forpole and othersurface complete all as specified and as directed.
50M & L for Yellow/black colour weather coat emulsion paint 2 coats of Cement surface forpole and othersurface complete all as specified and as directed.
51Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm). Incoming :- (i) Aluminium busbar rating 500 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitprotection having double insulation & positive insulation-01 No. Outgoing :-(i) MCCB 160 Amp 4 pole 02 Nos, MCCB 125 Amp 4 pole 01 No, MCCB 100 Amp 4 pole 01 No, MCCB 63 Amp 4 pole 01 No breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 200/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level.
52Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm). Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No. Outgoing :-(i) MCCB 40 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB SPN 20Amps - 03 Nos (ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level.
53S & F CPRI approvedstreet light panel of suitable dimension outdoor type, powder coated,dust and vermin proof IP-55,prewired , operates on three phase made with 1.6mm thick CRCA sheet with locking arrangement duly painted. having auto/manual selector switch, including MS flat iron clamp (Clamp shall be 40X 5mm ), nuts bolts & washers for fixing arrangement with pole and connecting incoming/outgoing cable with suitable size of lugs and comprising the following. (i)MCB , Four Pole of capacity 32 Amps ,C-curve of breaking capacity 10kA-2 Nos ( one for I/C and another for O/G) (ii) Astronomical timer(Astro mini ) 110-240VAC, 1 Phase . Cat Part No. T2DDT7 of L&T or equivalent in Havells/C &S (iii) 3 Pole contactor of Current rating AC1 50 Amps , with inbuilt surge protector and RoHS compliant. L& T Cat Part No: CS94568 or equivalent in Havells/ C&S (iv) LED type red indicator lamp (v) Auto/ Manual selector switch (vi) 63A, 4P, TERMINAL- 2 Nos (vii)2A, SP, 10kA MCB- 01 Nos (For timer protection)
54Taking down old servicable street light braket and refixing same after painting by surface preparationusing sand paper and applying two coats of aluminum paints over a coat of primer complete all as specified anddirected.
55S & F in repair 5 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consistingof sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangement complete all as specified anddirected Make: kakatiya energy system Pvt Ltd Cat No. Swadeep 66-02EC-5KW 3P or equivalent in Havells/GE
56S & F stainless steel 2 way Fire Brigade Inlet connection ISI marked with inbuilt Check Valve including taking down and removed from site complete all as specified and as directed.
57S & Fstainless steel 63 mm bore Heavy Duty Single Headed Fire Hydrant Landing valve As per IS:5290 type "A" ISI marked with ABS Blank capincluding taking down unserviceablve valve and removing from site complete all as specified and as directed.
58S & F Hose reinforced rubber lined fire Pipe ofSize 63 mm bore ( 15 Mtr Length ) WithBoth Side SS coupling ISI marked Male & Female connection type including taking down complete all as specified and as directed.
59S & FBranch Pipe with SS Nozzle as per IS 903 ISI marked including taking and removing from sitecomplete all as specified anddirected.
60S & F of Hosebox made of 18 gange MS sheet 800 mm x 600mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete including taking out old unservicebale Hose box and removing from site compelte all on specified and directed.
61S & F Hose reel Drum ( Wall Mounted) swingingtype as per IS : 884 includingHose pipe Length 30 Mtr Long of Size:- 20 mm bore thermo plastic hose as per IS 12585, ISI markedwith PVC ¾ “ Shutoff Nozzle (Hydraulically Crimped) including taking down and removing from site complete all as specified and as directed.
62S & F PVC Shut off Nozzle Size 20 mmbore ISI marked including taking down complete all as specified and as directed and removing from site.
63S & F Hose Clamp including taking down and removing from site complete all as specified and as directed.
64S & F 100mm Dual Plate Check Valve :- Cast Iron Body , D.I. Doors ,Nitrile /EPDM Seat ,Stainless Steel Shaft and springs P.N. 1.6 including taking down unserviceable and removing from site complete all as specified and as directed.
65Supply & Refilling of Carbon di Oxide Fire Extinguisher 4.5 Kg each complete all as specified and as directed.
66Supply & Refilling of ABC Powder Fire Extinguisher 6 Kg Each complete all as specified and as directed.
67Supply & Refilling of D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each complete all as specified and as directed.
68Supply & Refilling of Watermist baseFire Extinguisher 9 Ltr capacity each complete all as specified and as directed.
69Supply only Fire Extinguisher Hose Pipe ABC Type
70Supply only Fire Extinguisher Hose Pipe CO2 Type
71Supply only valve kit for Fire ExtinguisherABC Type
72Supply only Fire Extinguisher valve for foam type
73Supply only Fire Extinguisher valve forWatertype
74Supply only Pressure Meter
75Supply only Hanging Clip ( Hooke ) for Fire Extinguisher
76Supply only Carbon di Oxide Fire Extinguisher 4.5 Kg each
77Supply only ABC Powder Fire Extinguisher 6 Kg Each
78Supply only D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each
79Supply only Watermist baseFire Extinguisher 9 Ltr capacity each
80Labour only for Control Panel Fault Detection & Rectification by changing Necessary defective Components along with necessary copper wire, Lugs, Terminal etc. including testing complete all as specified and as directed. Note: Spare parts will be measured and paid separately under approprite item
81Supply only 3 Pole 32 A Power Contactor
82Supply only Thermal Overload Relay ,Relay Range 14-23 A
83Supply only Setof 3 Phase Indicating Lamps (Red Yellow & Blue )
84Supply only Push Button Assembly with auxiliary contact BlockStart & Stop
85Supply only 63 Amp TPN MCB10 KA
86Supply only 1 Pole 2 Way Rotary Cum Switch for Auto & Manual selection
87Supply only Single Phase Preventer
88Supply only Danfoss Make KP35 Pressure Switch
89Supply only Ball Valve 15 mm
90PVC Insulated & PVC Shethed Multi core bright Annealed bare Copper Conductor flexible Round Cables Size 1 Sq mm 2 core FRLSH
91Servicing of motor pump set by disassembling, (i)Motor Front over and back cover part by part dismantling, Internal Coil Heat Varnish, Insulation Testing & refixing. (ii) Pump Part by part Dismantling, ThroughServicing, replacement ofbearing & Gland Packing /Mechanical seal,re assembly with proper alignment complete all as specified and as directed.
92M & L for painting of motor pump set complete all as specified and as directed
93Supply, laying, jointing & testing MS tubing 100mm bore medium grade with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches or fixing complete with clips, wall hooks etc. complete all as specified and directed.