Tender For Comprehensive Maint Of Ac Plant, Ac Split/Window And Other Connected Works Under Age E/M-Ii Of Ge Dehradun, dehradun-Uttarakhand

Military Engineer Services-MES has published Tender For Comprehensive Maint Of Ac Plant, Ac Split/Window And Other Connected Works Under Age E/M-Ii Of Ge Dehradun. Submission Date for this Tender is 27-06-2023. HVAC Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

37980389
Corrigendum : Tender For Comprehensive Maint Of Ac Plant, Ac Split/Window And Other Connected Works Under Age E/M-Ii Of Ge Dehradun
Open Tender
Indian
Uttarakhand
dehradun
27-06-2023

Tender Details

Comprehensive Maint Of Ac Plant, Ac Split/Window And Other Connected Works Under Age E/M-Ii Of Ge Dehradun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jun-2023 BOQ amendment BOQ 27-06-2023
2 16-Jun-2023 Date amendment Date 27-06-2023
3 17-Jun-2023 Page Revised Other 27-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 79800.0 /-
Tender Value
INR 39.90 Lakhs /-

BOQ Items

Name of Work : COMPREHENSIVE MAINT OF AC PLANT, AC SPLIT/WINDOW & OTHER CONNECTED WORKS UNDER AGE E/M-II OF GE DEHRADUN.
Sl. No. Item Description
1Comprehensive maintenance by OEM or auth service person once in each quarters including emergency visits during contract period as and when required for the diagnosis of trouble, adjustment, minor repair or re-setting of controlas well as maintenance of central air conditioning plant chiller unit of capacity 3x150 TR and other connected installed machineries & accessories (screw type compressor 3x150TR(Make-M/S Trane)
2single stage 3000 rpm 415 volt AC 50 Hz, semi hermetically sealed motor of capacity 235 KW,Hot water generator 180 KW 2 Nos, 60 KW 1 No & pumping sets, condensing pumping sets 3 Nos, FRP cooling tower, mono block pump sets -3 Nos, Air handling units -34 Nos with belt driven motor, FCU 27 Nos,air blower fittings, shaft assembly cooling coilexpansion valve water softening plant control panel LT panel Remote control panel of AHU"s etc) with and including chemicals required for de scaling of condenser and chillers, compressor and connected motors etccompletelycleaning, removing the dust particles, servicing, replacement of all minor parts (costing less than Rs 500/ each part) , greasing, oiling, changing of compressor oil, charging of refrigerant as per manufacturer"s recommendation through out contract period all required for the efficient, smooth & satisfactorily functioning as per manufacturer"s instruction complete.
3Notes:- (a) The tenderers shall have to submit the copy of MOU with OEM M/s Trane company through its authorizedservice provider as a proof to carry outannual/quarterly/preventive maintenance etc recommended by OEM immediately after commencement of work and strictly follow the company maintenance recommendations.The rates quoted shall be deem to include all such maintenance cost."
4"(b) The contractor shall submit the record of periodical /preventive /annual maintenance service carried out M/s Trane along with recommendation of necessary repairs and maintenance procedure along with documentary evidence for claiming payment. The contractor shall produce the ""purchase order"" issued to M/s Trane/auth service provider for Annual Maintenance.
5(c) Contractors quoted rates shall be deemed to be inclusive of any miscellaneous minor spares such as wires, toggle switch, lugs, nuts, cable gland, connector, thimbles, gland packing etc when required or as ordered by Engr in Charge for smooth and uninterrupted operation of the complete system except spares such as mentioned here in after in relevant items of this schedule.
6(d) The item rates incl compressor oil and descaling etc and including cleaning/washing filters at 34 AHUs and 27 FCUs every month failing which a of penalty @ Rs 1000/- per month will be charged."
7(e) Yearly once Oil sample analysis of chiller compressor oil from Trane Factory for testing of oil parameters as mentioned in Trane chiller servicemanual. As per the oil analysis report replacement of Oil & Oil Filter for smooth and efficient working of compressor.
8(f)In case of any major break down the additional manpower if required will be arranged by the contractor to re-start the plant without any additional cost.
9(g)The rates are included extra labour for repairing and N2 pressure testing including N2 gas required for checking of leakage or repairing of compressor and overhauling.Refrigerant gas will be measured in relevant items.
10(h) The rates quoted shall include checking of ducting & grill for leakages and repair the same, loose fitting /tightening of ducting etc to reduce vibration & noise and gland packing of pumps etc. make up water tank /expansion tank ofhot water circuitand chilled water circuit, installed atthe roof of the plant room & various locations of hospital building. "
11Supplying laying fixing testing and commissioning of insulation of following sizes of chilled water piping inside the building with closed cell elastomeric nitrile rubber of insulation applied by adhesive confirming to standards specification complete all as specified and directed
12(a) 19 mm
13(b)25 mm
14(c)32 mm
15M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminous compound and GI cladding with 26-gauge GI sheet complete of sizes as shown complete including taking down complete all as specified and directed.
16(a) 32 mm
17(b) 40 mm
18(c) 50 mm
19"Note :- The rates of following are deemed to be include in above quoted rate.
20(a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreignmaterials, taking special care so that all duct joints are sealedagainst any leakage.
21(b) M&L for applying rubber based adhesive CPRX compound.
22(c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof.
23(d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr. complete all as specified and directed.
24(e) M&L for removing the scrapping items from the side."
25S & F in replacement of cassette type PRE filter made out MS GI sheet and galvanized iron stainless steel/aluminium anodized SS 304, nonwoolen synthetic media HPDE media having efficiency 90% down to 10 micron complete of following sizes:-
26(a)485x461x25 mm
27(b) 485x552x25 mm
28(c)465x519x25 mm
29(d)465x730x25 mm
30(e)501x655x25 mm
31(f) 585x439x25 mm
32(g) 585x449x25 mm
33(h) 610x610x25 mm
34(j)610x305x50 mm
35S & F in replacement Hepa filter of suitable size 1067x250x77 mm of AHU rated flow (CMH)=1700.IPD (mm WG) less than 25 and efficiency more than 99.97 down to 0.3 micro complete all as specified and directed.
36S & F in replacement fine filter of suitable size 610x305x305 mmof AHUrated flow (CMH)=1700.IPD (mm WG) less than 25 and efficiency more than 99% down 1 to 5 microncomplete all as specified and directed.
37All as per item No 6.00 above but of size 610x610x305mm
38M & L for rewinding of electric motor of the following capacity, 3 phase 50 HZ 415 Volt with super enameled copper winding wire of suitable gauge including insulating material, varnishing, heating, etc and including dismantling, reassembling and refixing after rewinding to its original location including testing and commissioning to its satisfactory results all as specified & directed.
39(a)up to 2 HP
40(b)3 to 5 HP
41(c)7.5 HP
42(d)15HP
43(e)20/25 HP
44M&L for changing of AC plant system from cooling to heating mode during winter season and shifting heating to cooling during summer as per direction of Eng-in-charge within seven days by draining out complete water from system washing the line min three times to remove impurities from line and refilling complete plant with soft water, checking system for leakage & arrest same duly testing and commissioning of the system complete all as directed.
45Note:- a) Plant is to be filled with soft water only and same will tested after filling if found hardness above permissible limit no payment shall be made.
46(b) Necessary chemical/additives required for the same except NaCl 35% are included in item rate.
47(c)If breakdown will exceed beyond seven days proportional payment shall be deducted from item No 1&2. The decision of GE shall be final & binding in this respect."
48M & L for overhauling/repairing to water softening plant incl replacement of strainer-02 Nos, resin, inlet tank, ejector after draining out water and removing silt etc scrapping out rust/ algae and cleaning complete including connections of water inlet outlet etc and reassembling all the dismantled components and testing including commissioning complete to the entire satisfaction of EIC.
49M&L for cleaning all the components by removing the side of pipes, tanks etc and painting the with two coats of synthetic enamel paint outside and moisture resistance primer inside complete all as specified and directed.
50M&L for charging of refrigerant gas R-134(a) with required pressure including arresting of all leakage and testing on full load, gas charging, Nitrogen pressure test to find out leakage pressure testing & arresting of all leakage throughout the maintenance contract period will be measured and paid only once throughout contract period complete after repetitive leakage/topping complete all as specified and directed.
51Supply & fixing in replacement V belt of following size.
52All as per item No 28.00 her in before but 3-5 Amp
53All as per item No 28.00her in before but 3.5-7.5Amp
54Supply & Fixing in replacement electronic timer 0-30 sec complete all as specified & directed.
55Supply and fix in replacement direct on line starter MK1 up to 7.5 HP complete all as specified & directed.
56Supply and fix in replacement LED Indicating lamp complete all as specified & directed.
57Repairing, Overhauling and replacement of dual Filter Media and activated carbon filtration vessels of MBBR STP 0.4MLD including Performing the following:-
58Supply & fixing in replacement power contactor 3 pole type MNX 50 415 volt, 50 Amps complete all as specified and directed.
59Supply & Fixing in replacement power contactor 3 pole type MNX 25,415 volt, 25 Amps all as specified and as directed
60Supply & Fixing in replacement power contactor 3 pole type MNX 18 with415 volt 18Amps complete all as specified and directed.
61Supply & Fixing in replacement power contactor 3 pole type MNX 9 with 415 volt, 9 Amps complete all as specified and directed.
62Supply and fixing of magnetic coil suitable for MO 25/MO18 or as per existing make suitable for 230/415 Volts AC supply operation complete all as specified and directed.
63Supply and fixing of magnetic coil suitable for MNX 9 to MNX 40 or as per existing make suitable for 230/415 Volts AC supply operation complete all as specified and directed.
64Supply and fixing of magnetic coil suitable for MNX 50 or as per existing make suitable for 230/415 Volts AC supply operation complete all as specified and directed.
65Supply & Fixing in replacement auxiliary contactor 3 pole type MNX 9 to 50 with a front add mounting complete all as specified and directed.
66Supply & Fixing in replacement electronic timer 0-30 sec complete all as specified and directed.
67Supply & Fix in replacement power indicating led lamp with holder assembly (R,Y,B)230 Volt AC complete all as specified and directed.
68Supply and fixin replacement of LED ammeter 0-30/0-40/0-60 amp rangesquare type 240volt AC 50 hzcomplete all as specified and directed.
69Supply and fixin replacement of LED Voltmeter 0-500 voltage rangesquare type 240volt AC 50 hzcomplete all as specified and directed.
70Supply & fix in replacement over load relay range 14-23amp, MN2 typecomplete all as specified and directed.
71All as per item No 27.00 above but range of 9-15 Amp.
72All as per item No 27.00 above but range of20-33 Amp
73All as per item No 27.00 above but range 2-10 Amp.
74Supply andfixin replacement of Push button NO/NC contact as per existing typecomplete all as specified and directed.
75Supply and fixing in replacement of HRC fuse 80A 120kA-500V as per IEC 60269-2 corrosion proofcomplete all as specified and directed.
76Supply & fixing in replacement CI butterfly valve of dia 50mm, PN 1.6 conforming to IS 13095 with side handle operated complete including packing material complete all as specified and directed.
77All as per Item No-33 above but 65 mm dia
78All as per Item No-33 above but 125 mm dia.
79All as per Item No-33 above but 150 mm dia.
80S & F in replacement motorized valve 2 way/3 way 19 mm dia(DN20) any dia for chilled water pipe line with and incl actuator motor complete and all other accessories required as per site requirement including testing and commissioningcomplete all as specified and directed.
81All as per item No 36 above but 32 mm dia
82All as per item No 36 above but 40 mm dia
83All as per item No 36 above but 50 mm dia
84Supply andfixin replacement of NRV/Check valve150mm,complete as per existing make size and type including packing material/gasketnut bolts etccomplete all as specified and directed.
85All as per item No 40.00but size 125 mm.
86All as per item No 40.00but size 80 mm.
87Supply & fixing in replacement balancingvalve 32/40 mm as per existing type & size including packing material testing & commissioningcomplete all as specified and directed.
88Supply & fixing in replacementbalancingvalve 50 mm as per existing type & size including packing material testing & commissioningcomplete all as specified and directed.
89Supply & fixing in replacementbalancingvalve 80 mm as per existing type & size including packing material testing & commissioningcomplete all as specified and directed.
90Supply & fixing in replacement balancingvalve 125 mm as per existing type & size including packing material testing & commissioningcomplete all as specified and directed.
91Supply & fixing in replacement industrial type alcohol filled thermometer 0-50 degree as per existing make & size and typecomplete all as specified and directed.
92Supply & Fix in replacement three phase heating element of capacity 14 to 16 KW for hot water generatorcomplete all as specified and directed.
93All as per item No 48 here and above but 6 to 7.5 KWcomplete all as specified and directed.
94Supply and fixing in replacement of PVC cooling fins size of 150x300x600mm in bluish shedding having thickness 0.2 mm and in hexagon shape for suitable mihir cooling tower of central type AC plantcomplete all as specified and directed. .
95S & F in replacement PVC float valve assembly 20mm dia including fitting complete all as specified and as directed.
96S & F in replacement pressure gauge round type of 10 cm dia metal cased between pressure range 0-10 Kg/sqcm including siphon assembly with gun metal stop valve including knob complete all as specified and as directed.
97Supply only cleaned salt not less than 35% Nacl for softening of water as per sample all as specified and as directed.
98S&F in replacementpre-fine blower filter 10-20 Micron of size 540x640x50mm as per existing make & size for RIMC AC Plant complete all as specified and directed.
99S&F in replacement offine blower filter 5 Micron of as per existing size and make 610x610x150mm, for RIMC AC Plant complete all as specified & directed.
100S & F in replacement water flow switch WF S6000 150 PSI 100 C 1" NPT 15 Amp 250 Voltcomplete all as specified and directed.
101M&L for dismantling all parts of AHU 3000 CFMfixed on ceiling inside false ceiling of the Med Ward of MH buildingcomplete all as specified and directed.
102M&L for repairing the rotor of motor taken down from AHU under item No 60 for making sound free and vibration free of AHU including replacement of bearing, bush, greasing and any machining work required to arrest any vibration & soundcomplete all as specified and directed.
103M&L for refixing the AHU after reassembling the same at the same placecomplete all as specified and directed.
104M&L for dismantling of chilled water pump with bronze impeller capacity of 1361 LPM @ 30 Mtr head including three phase induction motor of 15 HP from the base plate fixed in AC Plant Room MH buildingcomplete all as specified and directed.
105M&L for repair of base for refixing the motor and pump mentioned in item No 63 through the welding, drilling/any other machinery requiredPCC work and alignment of the base for making vibrate free and sound free base for motor and pumpcomplete all as specified and directed.
106M&L for refixing the motor and pump mentioned in item No 63 at the same placecomplete all as specified and directed.
107Supply in replacement air strip heater 3 KW finned type suitable for AC Plants complete all as specified directed.
108Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from window type AC and S&F New compressor suitable for window AC of capacity 1.5 Toncomplete all as specified and directed.
109All as per Srlitem No.64 here in beforebut compressorsuitable for window AC ofcapacity2.0 Toncomplete all as specified and directed.
110Dismantling and taking out the existing old unserviceable compressor hermetically/rotarysealed unit of any make from split type AC and S&F New compressor suitable forSplitAC of capacity 1.5 Toncomplete all as specified and directed.
111All as per Srlitem No.66 here in beforebut compressorsuitable for Split AC ofcapacity2.0 Toncomplete all as specified and directed.
112M&L for testing leakage in systemSplit/Window type Air conditioner of any capacity by injecting nitrogen gas upto 300 PSI, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vacuumizing the system complete all as specified and directed.
113M&L for servicing of Air conditioning window/split type of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplasticized PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed.Note :- (i) Petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department complete all as specified and directed (ii).Spare parts costing more than Rs 100.00 each item."
114S&F Starting capacitor of capacity 80-100 MFD.
115S&F Starting capacitor of capacity 100-120 MFD.
116S&F Condenser capacity of5-6 MFD.
117S&F Condenser capacity of10 MFD.
118S&F Condenser capacity of36 MFD.
119S&F Condenser capacity of45 MFD.
120S&F Condenser capacity of50 MFD.
121S&F Condenser capacity of60 MFD.
122Supply & fixing reverse cycle valve for heating system in window/split type AC 1.5/2 Ton capacity including charging of refrigerant gas R-22 and arresting all leakage and testing on full load, complete all as specified and directed. Note: Charging of R-22 shall be paid under relevant item.
123S&F Swing motor suitable for 1.5 Ton Capacity Window ACcomplete all as specified and directed.
124S&F Swing motor suitable for 2.0 Ton CapacityWindow ACcomplete all as specified and directed.
125S&F Swing motor suitable for 1.5 Ton Capacity Split ACcomplete all as specified and directed.
126S&F Swing motor suitable for 2.0 Ton Capacity Split ACcomplete all as specified and directed.
127S&F Over load relay suitable for 1.5/2.0 Ton WindowACcomplete all as specified and directed.
128S&F Over load relay suitable for 1.5/2.0 Ton SplitACcomplete all as specified and directed.
129S&F Electric blower motor suitable for 1.5 Ton Capacity WindowACcomplete all as specified and directed.
130S&F electric blower motor suitable for 2.0 Ton Capacity WindowACcomplete all as specified and directed.
131S&F electric blower motor suitable for1.5 Ton Split AC (Evaporator/Condenser)complete all as specified and directed.
132S&F electric blower motor suitable for2.0 Ton Split AC (Evaporator/Condenser)complete all as specified and directed.
133S&F Blower motor fan blade suitable for 1.5/2.0 Window type ACcomplete all as specified and directed.
134S&F Blower motor fan blade suitable for 1.5/2.0 Split type ACcomplete all as specified and directed.
135M&L for rewinding of Condenser motor suitable for 1.5/2.0 Ton capacity Window type ACcomplete all as specified and directed.
136M&L for rewindingof Condenser motor suitable for 2.0Ton capacity Window type ACcomplete all as specified and directed.
137M&L for rewindingof Condenser motor with fan blade suitable for 1.5 Ton capacity Split type ACcomplete all as specified and directed.
138M&L for rewindingof Condenser motor with fan blade suitable for 2.0 Suitable for Split type ACcomplete all as specified and directed.
139S&F Air Filter Suitable for1.5/2.0 Ton Capacity Window/Split type Air conditionercomplete all as specified and directed.
140S&F Capillary tube length as per existing size suitable for 1.5/2 Ton Capacity Air conditionercomplete all as specified and directed.
141S&F PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC complete all as specified and directed.
142S&F PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 split type capacity Air Conditionercomplete all as specified and directed.
143S&F Metal top with bottomsuitable for 16 Amps Capacity1.5/2.0 Ton Capacity Air conditionerMake:Anchor/Havells/Philips/polycab and as persite requirement.
144M&L for Refrigerant gas R22/R-32 for topping upcomplete all as specified and directed.
145M&L for Refrigerant gas R 410(a) for topping upcomplete all as specified and directed.
146M&L for replacement of damagedInsulation of size 1/4" & 3/8" copper tubeforAC complete as per existing sitecomplete all as specified and directed.
147M&L for replacement of damaged Insulation of size 1/2" & 5/8" copper tube for Split AC as per existing sitecomplete all as specified and directed.
148M&L in servicing of inverter AC of capacity 1.5/2.0 Ton with pressure cleaning complete all as specified and directed.
149M&L for replacement of Copper Tube of size 1/4” suitable for any type and any capacity Air conditioner complete all as specified and directed.
150M&L for replacement of Copper Tube of size 3/8" suitable for any type and any capacity Air conditionercomplete all as specified and directed.
151M&L for replacement of Copper Tube of size 5/8" suitable for any type and any capacity Air conditioner complete all as specified and directed.
152Taking out and shifting new locationand refixingboth indoor and outdoor unit ofsplit type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0 Tonin wall with rowel plugs including making holes for inlet /outlet in the wallwith condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplasticized PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed.
153S&F bracket for fixing of AC"scomplete all as specified and directed.
154M&L for repairs to walk in cooler 1.5 Ton andrepair/replacement the compressor, filter including gas charging and general service complete all as specified and directed.
155Dismantling and taking out the existing old unserviceable compressor sealed unit from Water cooler and S&F newcompressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I,suitable for Water cooler of cooling capacity 40/80 ltrs/hrs andcomplete all as specified and directed.
156All as per item No.111 here in before but compressorsuitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed..
157M&L for carry out through check up of the unserviceable watercooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department. complete all as specified and directed
158S&F Blower fan motor SP,230V, 50 Hz suitable for 40/80, 60/120 capacitywater cooleras per existing sample complete all as specified and directed.
159S&F Over load Protector suitable for compressor of water cooler 60/120 and 40/80 capacitycomplete all as specified and directed.
160S&F thermostat switch with knobsuitable for compressor of water cooler 60/120 and 40/80 capacitycomplete all as specified and directed.
161S&F PVC float valve assembly along with ball with complete accessories for water cooler any capacity of size 15 mm dia complete all as specified and directed.
162S&F Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 60/120 and 40/80 capacitycomplete all as specified and directed.
163M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed
164M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unitcomplete all as specified and directed.
165All as per item No.120.00 here in beforebut compressorsuitable for refrigerator capacity of 280 to 320 Ltrs complete all as specified and directed..
166S&F Freezer suitable for165 to 200 ltrs capacity Refrigeratorcomplete all as specified and directed.
167S&F Freezer door suitable for 280 to 320 Ltrs capacity Refrigeratorcomplete all as specified and directed.
168S&F Relay current type and over load protector suitable for compressorcomplete all as specified and directed.
169S&F Thermostat auto defrost type suitable for any make and any capacity Refrigerator single door complete all as specified and directed.
170S&F Thermostat auto defrost type suitable for any make and any capacity Refrigerator doubledoorcomplete all as specified and directed.
171S&F suitable timer for any capacity complete all as specified and directed.
172S&F Electric blower motor suitable for 300 ltr refrigerator inverter typecomplete all as specified and directed.
173S&F PCB Circuit suitable for 280-320 ltr refrigerator inverter typecomplete all as specified and directed.
174S&F cooling sensor suitable for 280-320 ltr refrigerator inverter typecomplete all as specified and directed.
175S&F thermostat suitable for 300 ltr refrigerator inverter typecomplete all as specified and directed.
176M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity upto 350 Ltrs Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unitcomplete all as specified and directed.
177All as per item No 132.00 here in beforebut compressorsuitable for refrigerator capacity more than 350 to 600 Ltrs complete all as specified and directed.
178M&L carry out through check up the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc completeNote:- petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the departmentcomplete all as specified and directed.
179S&F Relay current type and over load protector suitable for compressorcomplete all as specified and directed..
180S&F Thermostat auto defrost type suitable for any make and any capacity Deep Freezercomplete all as specified and directed.
181S&F Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per samplecomplete all as specified and directed.
182S&F Capillary tube of suitable length as per existing size for Deep freezer any make and any capacitycomplete all as specified and directed.
183S&F Starting relay with overload suitable for 310/320 ltrs capacity Deep freezercomplete all as specified and directed.
184S&F Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer complete all as specified and directed.
185Labour only for charging refrigerant gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and splittype Air conditioner after duly rectifying leakagesby welding/brazing and testing by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas to be measured and paid separately under relevant items of this schedule
186Dismantling and taking out the existing old unserviceable fan motor with blade including mounting brackets from Desert coolers and S&F new3 speed fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable forD/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed.
187M&L for repair to desert cooler dismantling the unserviceable partsof desert coolers, checking the general servicing complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department. complete all as specified and directed (ii).Spare parts costing more than Rs 100/- each itemsshall be measured and paid separately.
188S&F Water circulating submersible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr complete all as specified and directed.
189S&F Filter pad made out of wooden wool suitable for Air grills of desert cooler as per existing size
190S&F Capacitor for 2.5 MFDcomplete all as specified and directed.
191S&F Capacitor for 4MFD complete all as specified and directed.
192S&F Capacitor for 6 MFDcomplete all as specified and directed.
193S&F Front panel repair of dimension as per existing size suitable for desert coolerof capacity 4000/5000/6000 Cum per hrscomplete all as specified and directed.
194S&F PVC Flexible hose pipe size 12 to 15 mm suitable for desert coolercomplete all as specified and directed.
195S&F PVC Fan Blade suitable for 3000/4000/5000/6000 as per samplecomplete all as specified and directed.
196S&F Selector switch as per existing model and sizecomplete all as specified and directed.
197S&F Bolt, nut with washers as per samplecomplete all as specified and directed.
198S&F PVC Connector i.e (Elbow, Tee,3 way etc)complete all as specified and directed.
199S&F 5 Amp Switch piano type complete all as specified and directed.
200S&F 5 Amp Plug Top 3 pin complete all as specified and directed.
201Taking down the evaporative type desert coolers of Capacity up to 5000 Cum/hour by disconnecting all the electrical connections cleaning all the components by removing the side panels and painting the coolers with two coats of synthetic enamel paint outside and moisture resistance primer inside with spray painting and fixing back the removed panel and reconnecting with electrical connections and writing the MES No complete all as specified and directed.
202"S&F plastic body material Desert Cooler of 54 Ltr tank capacity 4 star rating 230V AC in white color complete all as specified and directed.
203S&F plastic body material Desert Cooler of 60 Ltr tank capacity 230V AC in white color complete all as specified and directed.