Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-06-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-06-2023 |
| 2 | 09-06-2023 | Amd BOQ | BOQ | 20-06-2023 |
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part-I (B/R itmes)Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover filletsand false ceilingframe work of any size/ description complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | S & FGI metal suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, for all heights as per specifications, including4mm thick HPSC pre-primenon asbestos fiber cement building board (E-classic or eqivalvent) decorative finish fixed to frame work with holdingdown clips in false ceiling complete all as specified and as directed by the Engineer-in-Charge |
| 3 | S & F 5mm PVC hollow sheet (the thicknees of inner wall 0.7 to 1.00mm) panelling inclusive of solvent cement and fixing at site with U clip or PVC frame as per specifications and drawing complete all as specified and as directed by the Engr-in-charge. |
| 4 | Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches,pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge. |
| 5 | M&L for brick work with sub class \"B\" old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge. |
| 6 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge. |
| 7 | Material and labour rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 andfinishedeven and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge. |
| 8 | M&L rendering 05 mm thick on fairfaces of brick work or concrete ceiling surfaces in cement mortar 1:3 andfinishedeven and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. |
| 9 | M & L rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4including mixing water proofing compound @ 2% by weight of cement or as per manufacturer\"s instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately) |
| 10 | Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge. |
| 11 | M & L preparation of exposed brick wall surface with brushes to remove all dirt / loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (Dilution ratio of 1:50) three times in a day for two days. After acid wash surface should be allowed to be air dried for one day. Carrying out efflorescence treatment to exposed and prepared wall surfacein the following sequence :–(a) Prime the prepared surface with one of the following product mixed with cement in 1:1ratio as bonding agent :–(i)Pidicrete URP of M/S Pidilite(ii) Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC(b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied \"BY HAND\" while the primer is tacky.PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturer\"s instructions :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC (c) PMM surface should be allowed to dry for one day.After that it should be painted with two coats of one of the following compounds mixed with cement only in ratio of one part of selected compound and one point five part of cement :–(i) Pidicrete URP of M/S Pidilite (ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC Contd... |
| 12 | item No. 11 (contd....)(d)Now apply two coats of one of the following compound over the surface.These compounds are to be used as per manufacturer instructions :–(i) Pidifin 2K of M/S Pidilite (ii)Brush Coat of M/s Sika(iii) Brush Bond of M/s FOSROCNote : Both coats should be perpendicular to each other and gap of application between two coats shall be minimum 6 hours.(e) Sprinkle loose coarse sand after second coat while surface is tacky.Note: (i) Item will be executed by authorised applicator of the selected /approved company only. (ii) Every stage of work will be approved by GE, then only next layer will be executed by contractor |
| 13 | M&Lpreparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the Engineer-in-Charge. |
| 14 | M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemperwith painting roller over a coat of alkali resistant primercomplete all as specified and as directed by the Engineer-in-Charge. |
| 15 | M&L preparation of newly plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge. |
| 16 | M & L complete removal of existing treatment on wall by scrappers or any other means and washing , rubbing down and stoppingand applying two coats of cement base paint on the walls, pillars, cornices etc.complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | M & L complete removal of existing treatment on wall by scrappers or any other means and washing , rubbing down and stoppingand applying two coats of oil bound distemper with paintingroller over a coat of alkali resistant primer on walls, pillars, cornices etc.complete all as specified and as directed by the Engineer-in-Charge. |
| 18 | M&L preparation of new/old plastered surfaces of wall andapplying2 to3mm thick wall care putty white cement based in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge. |
| 19 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge. |
| 20 | M&LNon-skid ceramic coloured tiles joint free premium/1st quality(square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in colouredcement to match the surface over and including screed bed 15 mm thick in cement mortar 1:6complete all as specified and as directed by the Engineer-in-Charge. |
| 21 | M&LNon Skid coloured ceramic tiles joint free premium/1st quality of same description as of floor tiles in serial item No20 abovebut 100mm to 200mm heightas in skirting, set and jointed in neat cement slurry and pointed in white or colouredcement mixed with pigmentto match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4complete all as specified and as directed by the Engineer-in-Charge. |
| 22 | Material and labour glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/ skirtings/dados of size 450x300x7mm thick/300 x 600 x 7 mm thickor nearest size as required , set and jointed in neat cement slurry and pointed in white or colouredcement mixed with pigmentto match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4complete all as specified and as directed by the Engineer-in-Charge. |
| 23 | Material and labour vitrified ceramic light shade tilespremium/1st quality 10mm thick (square/rectangular) area of each tile exceeding 0.42 sqm and notexceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick cement screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge. |
| 24 | Material and labour vitrified ceramic light shade tiles premium/1st quality 10mm thick of same description as of floor tiles as in serial item No 23 abovebut 100 mm to200mm heightas in skirting, set and jointed in neat cement slurry and pointed in white or colouredcement mixed with pigmentto match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4complete all as specified and as directed by the Engineer-in-Charge. |
| 25 | M & L rounding to edges of stone slabboth edge such as in steps, cooking plateformand other similar situtaions withgrinder complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge. |
| 27 | M & L25 mm thick PCC 1:2:4, type B0 as insub baseof floor (using 12.50mm gradedcrushed stone aggregate), finished even & fair without using extra cement complete all as specified and as directed by the Engr-in-charge. |
| 28 | M &L 10mm thick out doorcoloured paver tiles heavy duty of size 300 x 300mm in floors etc set and jointed in neat cment slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in C.M 1 :4 ,complete all as specified and as directed by the Engineer-in-Charge. |
| 29 | Cuttingchases to brick wall built in cement mortar, pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge. |
| 30 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge. |
| 31 | M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floorscomplete all as specified and as directed by the Engineer-in-Charge. |
| 32 | M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floorscomplete all as specified and as directed by the Engineer-in-Charge. |
| 33 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | S & F15mm bore cast copper alloy chromium plated angular stop valveswith capstan head, screwed down, high pressure scrwed both ends for iron pipe or for unions as in repaircomplete all as specified and as directed by the Engineer-in-Charge. |
| 35 | S&F bib taps 15mm bore fancy type brass chromium plated with long body,wall flanges and capstan head,screwed down,screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | S&F brass chromium plated single lever exposed parts kit of Hi–flow diverter consisting of operating lever, cartridge sleeve, wall flange (with seals) includingbutton assembly sleeve & button of Jaquar cat part No.OPP–15079NKPM orequivalent in Kohler /Cera/ Hindware including concealed body for single lever high flow diverter with button assembly of Jaquar cat part No. ALD–065N orequivalent in Kohler /Cera/ Hindware, bathtub spout with button attachment for hand shower with wall flangeof Jaquar cat part No. SPJ–15463PM orequivalent in Kohler /Cera/ Hindware, hand shower 140mm round shape sngle flow with air effect (ABS body & face plate chrome plated) with rubit cleaning system of Jaquar cat part No. HSH–1727 orequivalent in Kohler /Cera/ Hindware with flexible tube 8 /12mm dia & 1.5M long with nuts, overhead shower 190mm round shape single flow (ABS body chrome plated with gray face plate) with rubit cleaning system of Jaquar cat part No.OHS–497N orequivalent in Kohler /Cera/ Hindware andshower arm 600X25X25mm square shape for wall mounted showers with flange of Jaquar cat part No.SHA–455L600 orequivalent in Kohler /Cera/ Hindware withall connecting fittings as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 37 | S&F as in repair brass chromium plated exposedbody for single Lever basin mixer, wall Mounted consisting of operating lever, cartridge sleeve, wall flange, nipple & spout for 15mm dia pipe including brass chromium plated conceled of make:- Jaquar Cat Part No FUS–29233NK and ALD–233N/235N respectively orequivalent in Kohler /Cera/ Hindware withall connecting fittings complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | S & FPVC connections 15 mm sizewith PTMT nuts of length 600 mmas in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | S & Fvitreous chinatable top wash hand basin white,of size 565mmx420mmx140mm fixed on and including cast iron cantilever bracket,32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing ofwaste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 40 | S&F cabinet type looking mirror size 450 mm x 600 mm box typeincluding all as necessary items as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 41 | S&F as in repair brass chromium plated shower rose 250 to 300mm diaswivel type with arm600mm long with bend 45 degree as per site complete all as specified and as direced by the Engineer-in-charge. |
| 42 | S & F single piece vitreous china water closet wtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern& cistern fittings, S or P Trap complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No SLS -WHT-6855S / CERA Cat part No.S10131095 /Hindware Cat Part No.92099 (S-30) |
| 43 | S & F brass chromium plated hand shower ( health faucut)suitable for 15mm bore pipewith 8 mm dia 1.2 mtr long flexible tube and wall hook with NRV ( back flow preverntor )complete fixed to wall, fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 44 | Supply and fixing as in repairgrating doom125mm dia of PTMT (minimum weight 50gm)complete all as specified and directed by Engineer-in-Charge. |
| 45 | S & F corner Glass shelf 300 mm(with brassbracket)including fixing with brass screwsto wall complete, fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 46 | Supply & fixingas in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide and 60cm long with chromium plated guard and railing ,complete all as specified and as directed by the Engineer-in-Charge. |
| 47 | S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws as in repair complete all as specified and as directed by the Engineer-in-Charge |
| 48 | S&Ftoilet paper holder with flat recessed type stainless steelcomplete fixed to wallwith brass chromium plated screws as in repaircomplete all as specified and as directed by the Engineer-in-Charge. |
| 49 | S & F stainless steel304 grade wall mounted towel rack of size600 mm x 250mm with lower hanger including brackets,fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 50 | S & F brass CP Towel ring roundbetween flanges including fixing with brass screwscomplete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | S&F as in repair stainless steel tumbler holder and fixing with stainless screws to wall complete all as specified and as directed by the Engineer–in–Charge. |
| 52 | S & F 20 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for ironpipe as in repaircomplete all as specified and as directed by the Engineer-in-Charge. |
| 53 | Supply and fixing as in repairwater storage tank, 1000 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm diahigh pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore, complete all as specified and as directed by the Engineer-in-Charge.. |
| 54 | M & L 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 55 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified & directed by the Engr-in-Charge. |
| 56 | S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and as directed by the Engineer-in-Charge |
| 57 | S&FPVC(SWR)bends of any radius, for 110mm bore pipes, with access doors, complete all as specified and as directed by the Engineer-in-Charge. |
| 58 | S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal with acces doorcomplete all as specified and as directed by the Engineer-in-Charge. |
| 59 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors or fixed to wallscomplete all as specified and as directed by the Engineer-in-Charge |
| 60 | M & L PVC (SWR) gully trap, 125/110mm having pressure rating 6 Kg per sqcm and jointed with solvent cement as in repaircomplete all as specified and as directed by the Engineer-in-Charge. |
| 61 | Taking down chowkats or frames areanot exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge. |
| 62 | Taking down chowkats or frames area exceeding 1.50 Square meter andnot exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge. |
| 63 | S&F powder coated aluminium section (minimum thickness of powder coating 50 micron)work fordoors,windows & ventilatorsframes with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screwscomplete all as specified and as directed by the Engineer-in-Charge.Note : (a). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (b). The rates quoted shall be inclusive of neoprene beading,jointing clips, screws, etc as required and the sameshall not be measured for arriving the weight; |
| 64 | S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) fordoors,windows & ventilatorsshuttersincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screwscomplete all as specified and as directed by the Engineer-in-Charge.Note : (a). Glazing shall be measured and paid separately;(b).Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (c). The rates quoted shall be inclusive of neoprene beading, glazing clips, jointing clips, screws, etc as required and the sameshall not be measured for arriving the weight;(d). The rates shall be inclusive of locking arrangement including complete packing with silicon gel alround contacting surface of aluminium framework andincluding matching the existing surface area complete all as specified and directed. |
| 65 | S & F anodised aluminium grill (anodized transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to thewindow frame with C.P brass/ stainless steel screws @ 200 mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodized aluminium standard section around the opening, complete all as specified and as directed by the Engineer-in-Charge. |
| 66 | M & LPCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in holdfasts complete all as specified and as directed by the Engineer-in-Charge. |
| 67 | S&F 200 mm long aluminium powder coatedbarrel tower boltsof extruded section and fixed complete all as specified and asdirected by the Engineer-in-Charge. |
| 68 | S&F 150 mm long aluminium powder coated barrel tower boltsof extruded section and fixed complete all as specified and asdirected by the Engineer-in-Charge. |
| 69 | S&F 150 mm long aluminium handle casttype powder coated complete all as specified and as directed by the Engineer-in-Charge. |
| 70 | Supply and fixing 300mm long aluminum alloy, powder coated sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge. |
| 71 | M & L sheet glass 4.8mm thick ordinary quality and glazing with aluminium snap beading, rubber gasketin square not exc 0.5 sqm in each panecomplete all as specified and as directed by the Engineer-in-Charge. |
| 72 | M & L4.8mm thick frosted sheet glass ordinary quality and glazing with aluminium snap beading, rubber gasketin square not exc 0.5 sqm in each panecomplete all as specified and as directed by the Engineer-in-Charge. |
| 73 | Supplyand fixingstainless steelwire cloths0.36 mm nominal dia of wire and averagewidth of aperature 1.40 mm and fixed with stainless steelwire staple complete all as specified and as directed by the Engineer-in-Charge. |
| 74 | S & Ffloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 140mm complete all as specified and as directed by the Engineer-in-Charge |
| 75 | S&F aluminium (Diecast) body hydraulically door closer regulated,designation No.3, universal type,suitable for door shutters of 851 mm to 1000 mm in width and weight between 61 to 80 Kg complete all as specified and as directed by the Engr-in-charge. |
| 76 | S & F as in repairstainlesssteel curtain rod 25mm dia having wall thickness 1.00mmwith and including stainless steeldecorative brackets,two lotto for each rod length at both endetc fixed with stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. |
| 77 | S & F stainless steel fancy type peg setof 06 (06 Nos of hook in each) including fixing with steel screw and PVC rawel plugcomplete all as specified and as directed by the Engineer-in-Charge. |
| 78 | M & Lmild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders,walk ways, railingsconforming to Fe.290.Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge. |
| 79 | M&Lpreparation of new steelsurfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge. |
| 80 | M & LPCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge. |
| 81 | M & L providing and laying 60mm thick factory made chamfered edge cement concrete paverblock of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using platevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by the Engineer-in-Charge. |
| 82 | M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge. |
| 83 | S & F100 mm long type B-22, butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, powder coatedand fixed, complete all as specified and as directed by the Engineer-in-Charge. |
| 84 | S & F75 mm long type C-22, butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, powder coatedand fixed, complete all as specified and as directed by the Engineer-in-Charge. |
| 85 | S&F 100 mm long aluminium handle casttype powder coated complete all as specified and as directed by the Engineer-in-Charge. |
| 86 | M & L 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge. |
| 87 | Schedule \"A\" Part-II (E/M itmes)Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators,socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etccomplete all as specified and as directed by the Engineer-in-Charge. |
| 88 | Disconnecting electrical connection, taking down ceiling fans/exhaust fans of any sweep of any make with down rods, blades canopy etckept in safe cousdy of contractor \"s storetillcompletion of civil works and after completion of civil works cleaning the fan motor assembly body, blade of ceiling/ exhust fan, filling the cavity, rubbing with sand paper, taking off old paint with the help of chemicals & painting the ceiling fan/exhaust fans with one coat of superior quality synthetic enamel paint including writing the MES numberon the ceiling fans/exhaust fanswithsynthetic enamel paint, reassembling the ceiling fan/exhaust fans and refixingon the same loction, making electrical connection with 3 core copper condctorflexible cable of size 1.5sqm, testing complete all as specified and as directed by the Engr-in-charge. |
| 89 | Disconnecting electrical connection, taking down single/ three phase electric meter, kept in safe cousdy of contractor \"s storetillcompletion of civil works and after completion of civil works cleaning the electric meter and refixingon the same loction, making electrical connection, testing complete all as specified and as directed by the Engr-in-charge. |
| 90 | Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfacesand incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly(boxesshall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally) including provision of new covered plate over sunken box for housing themodular switches , modular socket outlets,modularfan regulators etc.for one light/fan/exhaust fan point controlledby one way switch,complete all as specified and as directedby Engineer-in-Charge. Note :-a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid forseparately . |
| 91 | Description same allas per item No. 90 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board,complete all as specified and as directedby Engineer-in-Charge. |
| 92 | Description same all as per item No.90but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board,complete all as specified and as directedby Engineer-in-Charge. |
| 93 | Description same all as per srl item No 90 here-in-before but for one socket outlet 15 Amp with 2.50 sq mm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge. |
| 94 | Description same all as per srl item No 90 here-in-before but for one socket outlet 15 Amp with 4 sq mm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge. |
| 95 | Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. |
| 96 | Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. |
| 97 | S&F modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge. |
| 98 | Supply& fixmodular socket outlet2/3 pin combined,6 Amp, one way, two module, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. |
| 99 | Supply& fixmodular socket outlet3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. |
| 100 | S&F electronic Fan regulator modular 100 watt, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge. |
| 101 | Supply and fix ceiling rose surface type 2/3 terminalpolycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge. |
| 102 | Supply & fixcalling bell ding dong 230 volt including removing unserviceable bell, complete all as specified and as directed by the Engr-in-charge. |
| 103 | Supply and fixing indoor decorative LED tube light fitting box type 18/20 wattwith electronic driver, opal diffuser, high efficient PVC housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hzincluding 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sinkand connecting with copper conductor flexible cablefrom ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directedby Engineer-in-Charge. |
| 104 | Supply and fixingLED flat panel 2\" x 2\" size fully difused surface/ recess mounted fitting (grid/ gypsum type)36-40 watt , 5700K, warm/cool whitewith powder coating and CRCA front cover including frame and driver with provision ofPVC flexible copper conductor cableto light fitting as in repair complete all as specified and as directed by the Engr-in-charge. |
| 105 | Supply and fixing LED batten fitting 10-12 watt, 2 feet, aluminium housing with electronic driver including tube rod 10/12 watt cool/warm typeindustrial model complete,connecting with copper conductor flexible cablefrom ceiling rose to connector of the lightas in repaircomplete all as specified and as directed by the Engineer-in-Charge. |
| 106 | S&F asin repair 3/5 watt LED light fitting wall mounting fixture (bed side lamp) in wooden housing including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete including removing unserviceable light fittings all as specified and as directed by the Engineer-in-Charge. |
| 107 | S&FLED Bldg Security Light Fittings of capacity 25 watt made up of die castaluminiumhousing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver, service bracketof mild steelpipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats ofsynthetic enamel paintoverone coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge. |
| 108 | S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp with top complete with and including one single pole MCB.20 Amp, 10 KA,\"C\" curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. |
| 109 | Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral withdouble door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. |
| 110 | Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA ,\"C\" curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. |
| 111 | Supply and fix MCB SPN, 6/32 Amps, 240 volt,10 KA ,\"C\" curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. |
| 112 | Taking down carefully existing electric water storage heaters of capacity 25lts and refixing the same after cleaning, including replacement of defective PVC connection etc complete all as specified and as directedby Engineer-in-Charge |
| 113 | Supply and fix sheet metal enclosure triple pole & neutral, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door with and including fixed type MCCB 63 Amp, 4 pole, 415 volts, 16 KAduly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connectionincluding making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. |
| 114 | S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium gradeISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. |
| 115 | Material & labourfor earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earthwire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test pointas directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/cboth ways with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testingas in repair complete all as directed by Engineer-in-Charge and earth testing on completion . |
| 116 | Supply and fixing modular TV socket complete all as specified and as directed by the Engr-in-charge. |
| 117 | M & L one run of coaxoalcopper wire cable suitable for TV connection drawn through and including concealedPVC conduit 15mm bore medium gradeISI markedwith all accessories such as bend, tee, sockets etc complete all as specified and as directed by the Engr-in-charge. |
| 118 | S&F asin repair 9/12 watt LED light fitting wall mounting fixture (sketch type) including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete including removing unserviceable light fittings all as specified and as directed by the Engineer-in-Charge. |
| 119 | Note:-Amount of credit ofRs. 87,738.80 for retrieved materials is mentioned in Schedule of Credit Page No. 40 & 41 of tender documents in pdf form which will be deducted offline while acceptance of tender. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail