| 1 | M&L for prepartion of old decorated plastered or unplastered surfaces of wall including filling of holes, cracks and undulating surface with cement base wall care putty making surface even and smooth and applying one coat of distemper oil emulsion paint (OBD)complete all as specified and directed by Engineer-in-Charge |
| 2 | Complete removal of existing treatment from brickwalls or concretesurfacesincluding scraping down smoke soots, moulds, moss and trading oil and greasy spots etc |
| 3 | M&L Providing and applying wall care putty of one coat over plastered surface to prepare the surface even and smooth complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for application of two coats oil bound distemper over one coat primer on putty surface of walls / surface obtain after complete removal of existing treatment complete all as specified and directed by Engineer-in-charge. |
| 5 | M&L for two coat of weather proof exterior emulsion paint over one coat of primer, colour and tintas approved on wall surface obtain after complete removal of existing treatment upto 15 metres height, including roof projection, fascias, parapets etc,complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for two coat of weather proof exterior emulsion paint over one coat of primer, colour and tint as approved in CCD pattern on new plastered wall surface / surface obtain after complete removal of existing treatment upto 15 metres height, including roof projection, fascias, parapets etc,complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for preparation of old painted ceiling surface and applying one coats of distemper oil emulsion (OBD) complete all as specified and as directed by Engineer-in-Charge |
| 8 | M&L for preparation of old decorated or unplastered surfaces of ceiling including cornices, pilasters and applying one coat of white washing complete all as specified and directed by Engineer-in-Charge |
| 9 | M&L for preparation of old decorated or unplastered surfaces of walls including cornices, pilasters and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge |
| 10 | M&L for preparation of old decorated or unplastered surfaces of walls including cornices, pilasters and applying two coat of white wash complete all as specified and directed by Engineer-in-Charge |
| 11 | M&L for preparation of old painted steel and iron surfaces and applying one coat of synthetic enamel paintof any description over 10cm width or girth complete all as specified and directed by Engineer-in-Charge |
| 12 | M&L for preparation of old painted wood and wood based surfaces and applying one coat of synthetic enamel paintof any description over 10cm width or girth complete all as specified and directed by Engineer-in-Charge |
| 13 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge |
| 14 | M & L for rendering 15 mm thick on fair faces of brick wall finished fair & even in CM 1:4 complete all as specified and directed. |
| 15 | M&L Preparing of new surface of wall and applying two coats of cement based paint over one coat of primer. |
| 16 | M&L Preparing of new surface of wall and applying two coats of cement based paint over one coat of primer,colour and tintas ordered in CCD pattern up to 15m height, complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for applying french polishing one or more coats on surfaces of any description, width or girth including filling of crack/cavity with wood filler after cleaning and preparing old polishied surfaces, complete all as specified and directed by Engineer-in-Charge |
| 18 | Preparation ofold plastered/unplastered old decoratedsurfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds, moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of cement base paint complete all as specified and as directed by Engineer-in-Charge |
| 19 | M&L for Writing letters or figures including dashes etc (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and as directed by Engineer-in-Charge |
| 20 | M&Lpreparation of old painted steel and iron surfaces of any description by brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots of roof /CGI Sheets, steel gates, steel doors, steel rolling shutters, steel eves boards etc,exc 10cm width or girth applying one coat of synthetic enamel paint in colour and tintas ordered OR in CCD pattern upto 15 metres height, complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L preparation of old painted wooden surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint colour and tintas ordered in CCD pattern upto 15 metres height, complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L forpreparation ofold painted surfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds, moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of weather proof, exterior emulsion paint colour and tintas ordered in CCD pattern upto 15 metres height including fascias, parapets etc, complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L forpreparation ofold painted surfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds, moss and efflorescence salts, trading oil greasy spots etc. and applyingtwo coat of cement base paint colour and tintas ordered in CCD pattern as approved upto 15 metres height, complete all as specified and directed by Engineer-in-Charge |
| 24 | M&Lpreparation ofold plastered / unplastered old decoratedsurfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds, moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of cement base paint colour and tintas ordered in CCD pattern complete all as specified and as directed by Engineer-in-Charge |
| 25 | S&F in repair second class soft wood weather boarding, clean sawn, thickness 20 mm and rebated on thick edge to give 20 mm laps and fixed in eaves board etc upto 15 metres height, complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for Preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat ofpink primer, complete all as specified and directed by Engineer-In-Charge. |
| 27 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-Charge |
| 28 | S & F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts in lieu of screws, in roofs, walls etc. with grade of zinc coating, complete all as specified and directed by Engineer-in-Charge. |
| 29 | All as per item No 28 but except Sheets, complete all as specified and directed by Engineer-in-Charge. |
| 30 | S & F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating, complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for Preparing new zinc (or galvanised) surfaces to receive painting, by coating with mordant solution including washing and cleaning, etc steel and iron surfaces and applying two coat of synthetic enamel paintof any description over 10cm width or girth in CCD pattern as approved complete all as specified and directed by Engineer-in-Charge |