Rural Engineering Services-RES has published Tender For Construction Of Science Lab And Art Craft Room At G.H.S. Singtali, Block-Narendranagar Tehri Garhwal. Submission Date for this Tender is 08-06-2023. Building Work Tenders in Tehri Garhwal Uttarakhand. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation in cutting in soil by manual means with lead up to 50 meter i/c all. |
2 | Excavation in foundation for retaining & breast walls in all types of soils and rocks including lead, lift and disposal of surplus material as per direction of engineer - in - charge |
3 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar.(As per PWD Uttarakhand specification |
4 | Random Rubble Masonary laid dry in breast cu.m wall,retaining wall, parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications |
5 | Hand Packed stone filling in back of wallls including cost of all materials,royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
6 | Earth work in excavation by mechanical means (Hydraulic Excavat in foundation trenches or drains (not exceeding 1.5 m in width or 1 including dressing of sides and ramming of bottoms, lift upto 1.5out the excavated soil and disposal of surplus excavated soil as dir of 50 m. All kinds of soil. |
7 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - -All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
8 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centring, shuttering,finishing and reinforcement - All work upto plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
9 | Random rubble masonry with hard stone in foundation and plinth i levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sandaggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) |
10 | Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in Cement mortar 1:6 ( 1 cement : 6 coarse sand ) |
11 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers,abutments, posts and struts etc. uptofloor five level excluding cost of centring, shuttering, finishing and reinforcement in1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
13 | Providing and fixing 30 mm th. ISI marked flush door shutters including stailness butt hinges with necessary screw conforming toIS: 2202 (Part I) non-decorative type, core of block board construction with frameof 1st class hard wood and well matched commercial 3 ply veneering with verticalgrains or cross bands and face veneers on both faces of shutters |
14 | Providing and fixing ISI marked oxidised M.S. tower bolt 150x10 mm black finish,(Barrel type) with necessary screws etc. complete |
15 | Providing and fixing ISI marked oxidised M.S. handles 125mm conforming to IS:4992 with necessary screws etc. complete |
16 | Providing and fixing ISI marked oxidised M.S. sliding door bolts 250mmwith nuts and screws etc. complete : |
17 | Providing and fixing M.S. Tubular frames for doors, ows, ventilatorsand cupboard with rectangular/ L-ypesections, made of 1.60 mm thickM.S. Sheet, joints mitred, welded and grinded finish, with profiles ofrequired size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
18 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer all complete. |
19 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shape and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
20 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.Cold Twisted Bars |
21 | 12 mm cement plaster of mix in 1:6 (1 cement : 6 fine sand) on smooth surface |
22 | 15 mm cement plaster on rough side of single or half brick wall of mix |
23 | Filling available excavatedearth (excluding rock)in trenches, plin sidesoffoundationsetc.inlayersnotexceeding20cminde consolidatingeachdepositedlayerbyramming andwatering, up to 50 m and lift upto 1.5 m. |
24 | Centring and shuttering including strutting,ropping etc. andremoval of form for Foundations, footings, bases of columns, etc. for mass concrete. |
25 | Centring and shuttering including strutting,ropping etc. andremoval of form for Suspendedfloors,roofs,landings,balconiesandaccess platform. |
26 | Centring and shuttering including strutting,ropping etc. andremoval of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
27 | Centring and shuttering including strutting,ropping etc. andremoval of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
28 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand |
29 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
30 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete |
31 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick |
32 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 grad finished with a floating coat of neat cement including cement slurry the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
33 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
34 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer |
35 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
36 | PaintingsteelworkwithDeluxeMultiSurfacePaintofrequired shade.Twoor more coat applied @0.90ltr/10sqmoveranundercoatofprimerapplied@0.75ltr/10sqm ofapproved brand or manufacture |
37 | PaintingwoodworkwithDeluxeMultiSurfacePaintofrequired shade.Twoor more coat applied @0.90ltr/10sqmoveranundercoatofprimerapplied@0.75ltr/10sqm ofapproved brand or manufacture |
38 | Renewing glass panes, with putty and nails wherever necessary includingracking out the old putty:14.5.1 Float glass panes of thickness 4 mm |
39 | Providing and laying cement concrete1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) in retaining walls, return walls, walls(any thickness) including attached pilasters, columns, piers, abutments,pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing |
40 | Providing and fixing on wall face unplasticised Rigid PVC 110 mm diameter rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single sockete |
41 | Lettering and painting of sign board i/c all |
42 | Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) with water proffing compound |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy