| Sl. No. | Item Description |
| 1 | SUB-HEAD : EARTH WORKSupplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 2 | SUB-HEAD : CEMENT CONCRETE WORKProviding and laying cement concrete in retaining walls, return walls (any thick-ness) including attached pilasters, columns, piers, abutmets, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centring shuttering and finishing - |
| 3 | 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification |
| 5 | SUB-HEAD : RCC WORKReinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- |
| 6 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- |
| 8 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with |
| 10 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 12 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 15 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 18 | Stairs (excluding landings) except spiral-staircases with wooden plank |
| 19 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. |
| 20 | Edges of slabs and breaks in floors and walls under 20 cm. wide |
| 21 | Weather shade, Chajjas, corbels etc., including edges. |
| 22 | Providing and fixing in position 12mm thick bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound in expansion joints. |
| 23 | Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour /shade of wall treatment. |
| 24 | Aluminium fluted strips 3.15mm thick : 150 mm wide |
| 25 | Non-asbestos fibre cement board 6 mm thick as per IS: 14862 [150mm wide] |
| 26 | SUB-HEAD : BRICK WORKFirst class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:- |
| 27 | In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 28 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- |
| 29 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 30 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 6th course offull brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:- |
| 31 | In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 32 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course ofhalf brick masonry work including anchorage in joints of 75mm in each side in superstructure for all levelincluding cost of all materials as required complete:- |
| 33 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 34 | SUB-HEAD : CLADDING WORKProviding and fixing gangsawcutofapproved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels:- |
| 35 | 18 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:- - Area of slab upto 0.50 sqm. |
| 36 | Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge:- |
| 37 | 18 mm Marble work. |
| 38 | Providingandfixing stoneslabwith tablerubbed, edgesroundedand polishedofsize75x50cmdeepand approved thicknessfixedinurinal partitions by cutting a chase of appropriate width withchasecutter and embeddingthestoneinthechasewithepoxygroutorwithcement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 6 mm nominalsize)as perdirection ofEngineer-in-chargeandfinished smooth including rubbing, curing etc. complete at all levels as required (measurement should be of exposed finished work):- |
| 39 | White Agaria Marble Stone of approved shade of 14 mm thick (75 x 50 cm). |
| 40 | SUB-HEAD : WOOD & PVC WORKProviding wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : |
| 41 | Local Teak wood |
| 42 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for paneled or paneled and glazed shutters 25 to 40 mm thick. |
| 43 | Local Teak Wood 16mm. Thick |
| 44 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. |
| 45 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. |
| 47 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 48 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 49 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 50 | 300 x 16 mm |
| 51 | 250 x 16 mm |
| 52 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 53 | 300 x 10 mm |
| 54 | 250 x 10 mm |
| 55 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 56 | 125 mm |
| 57 | 100 mm |
| 58 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 59 | Single rubber stopper |
| 60 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality) |
| 61 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 62 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solventadhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 63 | Providing 50 × 50 × 50 mm Gamair wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement: 3 fine sand) and making good the walls etc. |
| 64 | Providing and Fixing Channeled Hi Density Fiber Board Wall Panel (woodworks) (WC01C28LUMW) perforated panels of width 128mm, thickness of 15mm and length 2440mm with minimum 830 kg/M3 density substrate with a laminated facing as per the approved shade/species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of4mm width and 28 mm visible panel each. The panels shall provide a fire reaction of Class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.55. The panels shall be mounted on special aluminium splines using clips. Install wooden battens of section 50 mm x 50 mm or approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600 mm centre-to-centre. |
| 65 | Screw the aluminium-extruded keel for channeled wood works (GTPT001) over the lowest and second wooden batten at an on-centre distance of 600 mm. Install the first set of wooden panels by inserting the clips for border channeled woodworks (GTPT002) and insert the grove of the panel into the projecting flange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channeled woodworks (GTPT003) into the next keel till the actual height is achieved. Use clips for borer channeled woodworks (GTPT002) to finish off the installation. Finish off the edges using wooden moulding of matching colour approved by the Architect, suitably fixed all complete as per drawings and specification and direction of the Engineer-in-Charge. |
| 66 | SUB-HEAD : STEEL WORKProviding and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys& with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings,including applying a priming coat of approved steel primer etc. complete as required. |
| 67 | Providing and fixingfan clamp type-Iof 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete. |
| 68 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- |
| 69 | In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete. |
| 70 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:- |
| 71 | M.S. tube |
| 72 | Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design. |
| 73 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 74 | SUB-HEAD : ALUMINIUM WORK & STRUCTURAL GLAZINGProvidingandfixingaluminiumworkfordoors,windows,ventilators and partitions withextrudedbuiltupstandardtubularsections/ appropriateZsectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawingandthedirectionofEngineerincharge.(Glazingand paneling and dash fasteners to be paid for separately) :- |
| 75 | For fixed portion of approved quality:- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 76 | For shutters of doors, windows & ventilatorsincluding providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 77 | Providing and fixing glazing of approved quality in aluminium doors,windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- |
| 78 | With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 79 | With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm ) |
| 80 | Providing and fixing stainless steel ( SS 304 grade ) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:- |
| 81 | 205 x 19 mm |
| 82 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality completeas per direction of Engineer-in-charge:- |
| 83 | Anodised aluminium of grade AC 15. |
| 84 | SUB-HEAD : FLOORING AND SKIRTING WORKProviding and fixingMarble stone in floors over 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishingcomplete. |
| 85 | 18mm thick Marble Stone - Rajnagar plain marble |
| 86 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 87 | 8mm thick Rajnagar marble tiles (polished) |
| 88 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
| 89 | Double charged Stainfree vitrified tiles - Size of tile 60x60 cm |
| 90 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete |
| 91 | Double charged Stainfree vitrified tiles - Size of tile 60x60 cm |
| 92 | Providing and fixing Kota stone in floors over 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishingcomplete. |
| 93 | Kota stone slab 25mm thick |
| 94 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1 : 3 ( 1 cement : 3 fine sand ) and joined with ordinary cement slurry mixed with pigment to match the shade of slabs, including rubbing and polishing complete. |
| 95 | Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete. |
| 96 | Mat Finish Tiles - Ceramic Tiles 1st quality 400 x 400mm in all shades and designs |
| 97 | Anti-Skid Tiles - Ceramic Tiles 1st quality 400 x 400mm in all shades and designs |
| 98 | Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shadesof any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
| 99 | Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer-in-Charge. |
| 100 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete. |
| 101 | 40 mm thick |
| 102 | Providing and fixing tactiles of standardized designs conforming to RNIB (The Royal National Institute for the Blind, UK), DETR (Department of the Environment, Transport and the Regions, UK) & ADA (Americans with Disabilities Act, USA) of size 300 x 300 mm in floors, (thickness to be specified by the manufacturer) specially designed to assist the visually impaired - “foot braille”, with water absorption less than 0.5%, of approved brand & manufacturer, laid on 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) including grouting of joints (Payment for grouting of joints to be made separately) |
| 103 | SUB-HEAD : ROOFING AND CEILING WORKProvidingcorrugatedG.S.sheetroofingincludingvertical/curved surface fixedwithpolymercoatedJorLhooks,bolts andnuts8mm diameterwithbitumenandG.I.limpetwashersorwithG.I.limpet washersfilledwithwhiteleadandincludingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheets complete(uptoanypitchinhorizontal/verticalorcurvedsurfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 104 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 105 | Providing and fixing thermal insulation of ceiling (under deck insulation) withResinBondedFibreglasswoolconformingtoIS:8193density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythenebags fixed to ceilingwithmetalliccleats(50x50x3 mm) @ 60cmandwiremesh of 12.5mm x 24g wire and mesh, for top most ceiling of building. |
| 106 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes (working pressure 4 kg/cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion: |
| 107 | Single socketed pipe - 110 mm OD |
| 108 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-Aincludingjointingwith sealringconformingtoIS : 5382 leaving 10 mm gap forthermalexpansion: |
| 109 | Coupler - 110mm |
| 110 | Single equal tee with door - 110 x 110 x 110 mm |
| 111 | Single equal tee without door - 110 x 110 x 110 mm |
| 112 | Bend 87.5 - 110mm |
| 113 | Plain shoe - 110 mm |
| 114 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVCrainwater pipesbymeansof50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work andfixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete. |
| 115 | 110mm |
| 116 | Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete. |
| 117 | 100mm |
| 118 | SUB-HEAD : FINISHING WORK12 mm cement plaster of mix |
| 119 | In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 120 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 121 | Cement mortar 1:6 (1 cement : 6 fine sand) |
| 122 | 6 mm cement plaster of mix: |
| 123 | In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) |
| 124 | Neat cement punning. |
| 125 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : |
| 126 | New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 127 | Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : |
| 128 | New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 129 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : |
| 130 | With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 131 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: |
| 132 | Two or more coats on new work |
| 133 | SUB-HEAD:WATER PROOFING WORKGrading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with : |
| 134 | Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 135 | Cement mortar 1:4 (1cement : 4 fine sand) |
| 136 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound, as directed by Engineer-in-Charge and consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 137 | SUB-HEAD : SANITARY WORKSProviding and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushingcisternwithmanuallycontrolleddevice(handlelever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 138 | White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 139 | Providingandfixingwhitevitreouschinapedestaltypewatercloset (Europeantype W.C.pan)withseatandlid,10litrelowlevelwhite P.V.C.flushing cistern withmanually controlled device (handlelever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 140 | W.C. pan with ISI marked white solid plastic seat and lid |
| 141 | ProvidingandFixingwhitevitreouschina flatbackorwallcornertype lipped front urinalbasinof430x260x350mmand340x410x265mmsizes respectively withautomaticflushingcisternwith standard flushpipe andC.P.brassspreaderswithbrassunionsandG.Iclamps complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : |
| 142 | Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. |
| 143 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 144 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: |
| 145 | Flat back wash basin of size 550x400mm. |
| 146 | Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: |
| 147 | Size 600x450x200 mm. |
| 148 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 149 | Semi rigid pipe - 32 mm dia |
| 150 | Flexible pipe - 32 mm dia |
| 151 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 152 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 153 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approvedquality and colour. |
| 154 | 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. |
| 155 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 156 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms. |
| 157 | ProvidingandfixingonwallfaceunplasticisedRigidPVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion: |
| 158 | Single socketed pipe - 110 mm OD |
| 159 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-Aincludingjointingwith sealringconformingtoIS : 5382 leaving 10 mm gap forthermalexpansion: |
| 160 | Coupler - 110mm |
| 161 | Single pushfit Coupler - 110 mm |
| 162 | Single equal tee with door - 110 x 110 x 110 mm |
| 163 | Single equal tee without door - 110 x 110 x 110 mm |
| 164 | Doubleequal junction of required degreewithout door - 110x110x110 x110 mm |
| 165 | Doubleequal junction of required degreewith door - 110x110x110 x110 mm |
| 166 | Bend 87.5 - 110mm |
| 167 | Plain shoe - 110 mm |
| 168 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVCrainwater, soil, waste & vent pipesbymeansof50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work andfixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete. |
| 169 | 110mm |
| 170 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand): |
| 171 | 100 mm dia. |
| 172 | SUB-HEAD : WATER SUPPLY Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. - Internal work - Exposed on wall. |
| 173 | 15 mm dia. nominal bore |
| 174 | 20 mm dia. nominal bore |
| 175 | 25 mm dia. nominal bore |
| 176 | 40 mm dia. nominal bore |
| 177 | 50 mm dia. nominal bore |
| 178 | Providing and fixing G.I pipesof medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including making good the walls/floor etc. concealed pipe includingpainting two coats or more with anticorrosive bitumastic paint, cutting chases and making good the same complete as per CPWD specification and direction of the Engineer - in - charge. |
| 179 | 15 mm dia. nominal bore |
| 180 | 20 mm dia. nominal bore |
| 181 | Making connection of G.I. distribution branch with G.I. mainfollowing sizes by providing and fixing tee, including cutting and threading the pipe etc. complete as per CPWD specification and direction of the Engineer - in - charge. |
| 182 | 25 to 40 mm nominal bore |
| 183 | Providing and fixing brass bib cock of approved quality : |
| 184 | 15 mm nominal bore |
| 185 | Providing and fixing brass stop cock of approved quality : |
| 186 | 15 mm dia nominal bore |
| 187 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): |
| 188 | 25 mm nominal bore |
| 189 | 40 mm nominal bore |
| 190 | Providing and fixing gun metal non-return valve of approved quality (screwed end): |
| 191 | 25 mm nominal bore - Vertical |
| 192 | 40 mm nominal bore - Vertical |
| 193 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 194 | Constructing masonryChamber 30x30x50 cm, inside , in brick workincement mortar1:4 (1 cement :4 fine sand) forstopcock, withC.I.surface box100x100x75mm (inside)with hingedcover fixedincement concreteslab1:2:4mix (1 cement:2 coarsesand:4gradedstoneaggregate20mmnominalsize) necessary excavation foundationconcrete 1:5:10 ( 1cement :5fine sand:10gradedstoneaggregate40mmnominalsize)andinside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finishedwithafloatingcoatofneatcementcompleteasper standard design : |
| 195 | With Second Class bricks |
| 196 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats overa ready mixed priming coat, both of approved quality for new work : |
| 197 | 15 mm diameter pipe. |
| 198 | 20 mm diameter pipe. |
| 199 | 25 mm diameter pipe. |
| 200 | 40 mm diameter pipe. |
| 201 | 50 mm diameter pipe. |
| 202 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 203 | 15 mm diameter pipe |
| 204 | 20 mm diameter pipe |
| 205 | 25 mm diameter pipe |
| 206 | 40 mm diameter pipe |
| 207 | 50 mm diameter pipe |
| 208 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 209 | 15 mm nominal bore. |
| 210 | 20 mm nominal bore. |
| 211 | 25 mm nominal bore. |
| 212 | 40 mm nominal bore. |
| 213 | 50 mm nominal bore. |
| 214 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: |
| 215 | 100 mm diameter |
| 216 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |