| 1 | Electrical Works. |
| 2 | Supply & fixing90W LED Street light having die cast aluminium body and diffuser with driver set suitable for 90 Watt confirming to IP 66 protection complete in all respect including cost of material,men and T&P. Minimum CAT AA(Crompton/Bajaj/Wipro /Philips make with 5 Year Warrenty against defects at site,declareation issued issued by OEM/Contractor. |
| 3 | Dismantling of existing sodium street lights including PVC cable,bend pipe, clamp etc. from ST pole including cost of men and T&P. |
| 4 | Supply & fixing 32mm dia,1.20M long GI bend pipe with 02 nos. clamp of 50x6mm MS Flat suitable for fixing street light on ST pole. |
| 5 | Supply & fixing Supply & fixing of street light junction box made of SMC material complete with 4 way terminal block,cable gland etc. |
| 6 | Supply & fixing0.5Amp to 6.0Amp SP MCB in M.S Box complete in all respect.(CAT B) |
| 7 | Supply & erection of \"D\" clamps of 38 mm x 6 mm flat iron for wall /roof type service bracket with bolts, nuts etc. complete in all respects including painting with aluminum paint . |
| 8 | Supply ,laying & drawing of 3x1.5 sq.mm PVC insulated copper cable for street/flood light connection in existing pipe/surface/airincluding cost of all material, men andT&P as (Havell\"s/Polycab/Grandlay /Glostar) |
| 9 | Supply & fixing 40 TPN capacity of automatic street light cubical panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors,HRC fuses, isolating switch metering instrument & instrument box with CT\"s etc. |
| 10 | Providing & fixing 25mm x5mm G.I. earth strip on surface or in recess including cost of GI saddle/Al. Alloy/cadmium/PVC fastener etc.plated iron screw etc. as required for connections. |
| 11 | S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect as per drawing. |
| 12 | Supply and erection of steel tubular pole 410 SP-44 10.0 M long. 168 Kg complete inclusive hardware and ordinary pole fittings with Painting of two coats of aluminum and one coat of red oxide paint including foundation work with 1/6th of overall length of pole below ground level with 45cm dia cement concrete with 45cm above the ground leval. The foundation of underground will not be less than 20cm thick layers of cement concrete in the ration of 1:3:6 (Cement :coarse sand : over burnt brick ballast/stone ballast), The brick ballast/stone ballast will be used of 1.25cm size with stone pad of 30x30x7.5cm at the base. as per direction of E/I of work/site including all T&P, men and material for proper completion of work. The bottom of pole should be galvanised as per PVVNL. |
| 13 | Supply and erection of stay of existing LT lines for ST pole with GI anchor plate (152x152x6mm) stay rod (16mm dia x 1.85 m long) GI stay below (16mm dia rod , thriple, double stay tightener, stay insulator, clampas & stay wire (GS 7/3 .15mm) including grouting in 1:4:8 ratio of cement corcente using coars sand, over burnt brick ballast as per direction of engineer in charg complete in all respect. |
| 14 | Supply, sagging & tensioning of overhead line with insulated ACSR Weasal conductor including cost of material,men and T&P. |
| 15 | Supply & fixing pole fitting suitable for single phase three wire line in vertical configuration of two numbers 50x6mm clamp of MS flat with two numbers 100x115mm shackle insulator and one number 50x6mm M.S. clamp for earth wire. |
| 16 | Supply & fixing LT extera angle/Section pole fitting suitable for single phase three wire line of two numbers shackle insulator of 100x115mm size and with four numbers 250 x 40 x 3 mm with 18mm dia hole including cost of nut & bolt,washers,men and T&P. |
| 17 | Supply & fixingLT shackle insulator including cost ofmaterial ,men and T&P. |
| 18 | Supply and fixing of MS/GI clamp as per design suitable for fixing shackle insulator/earth wire, made out for 50x6mm M.S. Flat including nut, bolt & washer. |
| 19 | Providing & Fixing PVC Spacer suitable for LT line including cost of material, men and T&P. |
| 20 | Supply, sagging & tensioning of 6 SWG GI earth wire including cost of material,men and T&P. |
| 21 | Supply and laying of 16 sq.mm 2 core aluminium conductor PVC insulated, unarmoured, served, sheathed cable 1100 V grade in existing pipe/Surface/pole etc. (Havells/Polycab/Grandley) |
| 22 | Supply and laying of 25 sq.mm 3.5 core. size aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade in existing pipe/Surface/pole etc.(Havells/Polycab/Grandley) |
| 23 | Supply and laying of 50 sq.mm 3.5 core size aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade in existing pipe/Surface/pole etc.(Havells/Polycab/Grandley) |
| 24 | Supply & Laying of63 mm HDPE/DWC pipe ISI marked including cost of all material, men and T&P.along with all accessories like socket,bend,couple etc. confirming to IS 14930 Part II complete with fitting and cutting,jointing etc direct in ground (750-1000mm below ground level) including excavation and refilling the treanch. including cost of material,labour and T&P. |
| 25 | Supply & Laying of63 mm HDPE/DWC pipe ISI marked including cost of all material, men and T&P.along with all accessories like socket,bend,couple etc. confirming to IS 14930 Part II complete with fitting and cutting,jointing etc direct in ground (750-1000mm below ground level) through horizontal boring(trenchless) by making pit at regular interval and refilling the pit after work as before on road crossing including cost of all material, men and T&P. |
| 26 | Supply & Laying of90 mm HDPE/DWC pipe ISI marked including cost of all material, men and T&P.along with all accessories like socket,bend,couple etc. confirming to IS 14930 Part II complete with fitting and cutting,jointing etc direct in ground (750-1000mm below ground level) including excavation and refilling the treanch. including cost of material,labour and T&P. |
| 27 | Supply & Laying of90 mm HDPE/DWC pipe ISI marked including cost of all material, men and T&P.along with all accessories like socket,bend,couple etc. confirming to IS 14930 Part II complete with fitting and cutting,jointing etc direct in ground (750-1000mm below ground level) through horizontal boring(trenchless) by making pit at regular interval and refilling the pit after work as before on road crossing including cost of all material, men and T&P. |
| 28 | Supply & fixing of 50 mm dia GI pipe B classfor climbing up the cable from ground to over head line LT pole complete withGI fitting including material,labour and T&P |
| 29 | Supply & fixing MS clamp made out from 50x6mm MS flat for securing 50mm GI Pipe/HDPE with ST pole. |
| 30 | Painting letters (Pole No.) 2.5cm up to 8.0 cm size complete on Street light Pole/Panel/Other electrical properties under UPSIDA including cost of all material, men and T&P. |
| 31 | Providing new street lights pole earthling of an existing pole by inserting MS Rod 20x2500mm in vertically ground level and connecting the pole with the help of 6 SWG GI wire including cost of all material, men and T&P. |
| 32 | Cleaning & spray painting of ST bend pole and power ST pole (up to 7.0 Mtr height in case of shut down)with one coat of red oxide primer and two coat of alum. paint/PU paint as per direction of Engineer incharge including cost of all material, men and Hydraulic crane, other T&P. (Burger/Nerolac/Asian make) |
| 33 | Strengthen of ST pole foundation by providing new concreting including broken of weak foundation,excavation, surface finishing and painting ,cost of all material,men and T&P. |
| 34 | Supply & fixing 3-Phase Power Contractor ML-3 type or equel for Automatic Street & High Mast Control Panel in cluding cost of Connection, men and T&P.(Only for AMC) |
| 35 | Supply & fixing Astronomical time switch L&T/Siemens/C&S or equel brand including cost of connection, material, men and T&P. Only for AMC |
| 36 | S&F of 63 amp. 4 pole MCB (10KA cat B) for control panel complete in all respects.(Only for AMC) |
| 37 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 25/35/50 sq.mm 3.5 core cable of 1100 v grade complete. |
| 38 | Trimming of tree branch around the street light pole/ST pole/Central Varge for proper illumination& proper disposal of tree branch collecting on trolly or similer moving item including cost of men, trolly, T&P etc. |
| 39 | Dismantling of damaged ST pole which cause to any accident of men and UPSIDA property. in industrial area including cost of men and T&P and shifting to store charge. |
| 40 | Dismantling & re-grouting of street light/Steel tubler (upto 12 Mtr long) Tilt/sick bend pole in 1:3:6 ratio cement concrete with stone pad includingstrengthening of pole by providing additional 04 Nos. support of65x65x6mm or higher sizeMS angle in suitable length with the help of welding/cutting as per technicalspecification. |
| 41 | Hiring Charge of 80-100 feet expandable street light repairing hydraulic lift, capacity 300 Kg including cost of operator, mounting vehicle and fuel etc. (Only for AMC) |
| 42 | Cost of material spares, wire, fuses, small accessories, alum. Lug up to 16 sq.mm , small cable gland , insulation tap,plastic tie, screw, nut & bolts, old cloth, cleaning spray and other small associated required for up-gradation work etc. (Only for AMC) |
| 43 | Providing operating cum maintenance staff of the entire street light networkfor routine maintenance of road lighting system,administrative,site offic and staff colony etc. including dismantling & re-fixing of other street lights of UPSIDA with there travelling expenses etc.(Only for AMC) |
| 44 | Fabrication, supply and fixing of work information board in M.S. frame made by 50mm dia Square Pipe of Stainless steel grade SS-304 & 16 mm thick base plate with back supporting of bracing by MS flat of 25x6mm and 2.85 Mtr long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green color with white letters as required and shall be fixed at a height of 1.2 Meter from ground by providing 0.45x0.45x0.60 Mtr cement concrete stone pad as per drawing enclosed. |
| 45 | Buy back of old/defective/damaged 150W sodium lights fitting as is as where condition. |
| 46 | Buy back of damaged ST pole as scrap as is as where condition. |