Bids Are Invited For Custom Bid For Services - --Upkeeping Of Electrical, Fire Fighting And Utility System At Salempur Lpg Plant 1. Mcc Panels = Preventive Maintenance Quarterly, Half-Yearly, Yearly As Per The Schedule. All The Pms Sheets After Signing , hathras-Uttar Pradesh

Ministry Of Petroleum And Natural Gas-MOPNG has published Bids Are Invited For Custom Bid For Services - --Upkeeping Of Electrical, Fire Fighting And Utility System At Salempur Lpg Plant 1. Mcc Panels = Preventive Maintenance Quarterly, Half-Yearly, Yearly As Per The Schedule. All The Pms Sheets After Signing . Submission Date for this Tender is 03-06-2023. Fire Fighting Consumable Tenders in hathras Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37822508
Bids Are Invited For Custom Bid For Services - --Upkeeping Of Electrical, Fire Fighting And Utility System At Salempur Lpg Plant 1. Mcc Panels = Preventive Maintenance Quarterly, Half-Yearly, Yearly As Per The Schedule. All The Pms Sheets After Signing
Open Tender
Indian
Uttar Pradesh
hathras
03-06-2023

Tender Details

Bids Are Invited For Custom Bid For Services - --Upkeeping Of Electrical, Fire Fighting And Utility System At Salempur Lpg Plant 1. Mcc Panels = Preventive Maintenance Quarterly, Half-Yearly, Yearly As Per The Schedule. All The Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. Cleaning Of Panel To Be Done On Quarterly Basis, All Nuts And Bolts Of Conductor To Be Tighten After Taking Prior Shut Down. 2. Earth Pit Testing = Preventive Maintenance Monthly, Quarterly, Half-Yearly & Yearly As Per The Schedule To Be Done. All The Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. Testing Of Earth Pit On Half Yearly Basis To Be Done Religiously And Report To Be Submitted. 3. Transformer And Allied Equipment = Preventive Maintenance Monthly, Quarterly, Half Yearly & Yearly As Per The Schedule To Be Done. All The Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. Oil Testing To Be Arranged By Party On Yearly Basis 4. Air Circuit Breaker = Preventive Maintenance Yearly As Per The Schedule. All The Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. 5. Generator Engine ( 125Kva, 320 Kva And 380 Kva ) Preventive Maintenance Monthly, Quarterly, Half Yearly, Yearly As Per The Schedule. Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. Party Has To Do The Regular Routine Maintenance & Major Maintenance Will Be Done By The Oem As Arranged By The Company. 6. Dg Alternator & Control Panel = Preventive Maintenance Monthly, Quarterly, Half Yearly & Yearly As Per The Schedule. Checking Of Dg Tripping Report To Be Submitted On Quarterly Basis. 7. All Electrical Motors And Their Local Controls Panels, Push Buttons & Cables= Preventive Maintenance Monthly, Quarterly, Half Yearly, Yearly As Per The Schedule. Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. Motor Current To Be Note Down On Monthly Basis, Motor Winding Insulation And Cable Insulation To Be Checked On Half Yearly Basis And Report For Same To Be Submitted. 8. Cathodic Protection = Preventive Maintenance Monthly, Quarterly, Half Yearly & Yearly As Per The Schedule. . Pms Sheets After Signing Of The Officer Should Be Submitted With The Bill. Minor Maintenance Will Be Done By The Party & Major Maintenance Will Be Arranged By The Company From Oem. 9. All Critical Equipments And Their Control Panels. 10. Instrumentation Panel And Its Field Equipments. 11. Lighting System Of High Mast Tower, Building And Shed Lightings And Lighting In Admin Building. Lux Meter Reading To Be Noted Down On Quarterly Basis And Report For The Same To Be Submitted Along With The Bill. 12. Testing Of Relays And Making Proper Setting. 13. Checking And Resetting Of Relays In Starter Of Motors Of Each Motor Starter In Mcc Panel As Well As Panels Of Critical Machines. 14. Ensuring Proper Rating Hrc Fuses Are Put In Panels. 15. Ensure All Indicator Lamps Are In Working Condition And Are In Place. 16. Electrical Maintenance Of Equipments Not Given Above But Instructed By Officer. 17. Checking Of Capacitor Bank To Be Done On Monthly Basis. And Format Of Performance Of Capacitor To Be Submitted Along With Bill. 18. Checking Of Flp Glands To Be Done On Monthly Basis And Report To Be Submitted Along With The Bill. If Any Loose Gland Found Then It Should Be Attended Immediately. Any Oversize Gland To Be Replaced With New Flp Gland Provided By Bpcl 19. Updation Of Single Line Diagram On Yearly Basis To Be Done By Contractor Personally And Same Should Be Discussed With Plant Officer. 20. Updation Of Earth Pit Diagram On Yearly Basis To Be Done By Contractor Personally And Same Should Be Discussed With Plant Officer. Following Electronics Thing Needs To Be Checked 21. Ensure Proper Working And Power Supply To Cctv Cameras Nos. 22. Checking Of All Connection Of Kosan Connector And Cleaning The Same With Crc / Aerosol On Sunday / Holiday Or As Directed By Bpcl Officer. Frequency- Monthly 23. Checking Of Ups For Back-Up To Be Done On Sunday And Proper Records To Be Maintain On Monthly Basis. Frequency- Monthly 24. Checking Of Hand Held Metal Detector And Door Frame Metal Detector On Monthly Basis. Frequency- Monthly 25. Checking Of Battery For Its Proper Function--- Frequency- Daily 26. Checking Of Dragon Light For Its Proper Function- Frequency- Daily 27. Checking Of All Telephone Connection As Well As Instrument. Hand Receiver Coil If Found Damaged Same Needs To Be Replaced Immediately- Frequency- Monthly 28. Checking Of Automatic Switch On / Off Light Provided For Its Proper Workingfrequency- Monthly 29. Checking Of Timer Provided For High Mast Tower For Its Proper Functioning- Frequencymonthly 30. Checking Of Timer For Shed Light - Frequency- Monthly 31. Providing Solution For Electronic Card Safety- Frequency- Monthly 32. Checking Of Fire Engine Panel For Battery Charging - Frequency- Daily 33. Checking Of Led Light If It Is Not Working. Frequency- Monthly 34. Checking Of Vhf Battery Charger -- Frequency- Daily 35. Checking Of Gms Charger-- Frequency- Daily 36. Checking And Health Monitoring Of Iris System And Closing Of Alerts Within 1 Hour Of Alert Generation.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 27.80 Lakhs /-