Tender For Repair And Maintenance Of Various Electrical Appliances And Other Misc E/M Works Under Ge (Af) Srinagar, srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Various Electrical Appliances And Other Misc E/M Works Under Ge (Af) Srinagar. Submission Date for this Tender is 19-06-2023. Electrical Products Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37797214
Corrigendum : Tender For Repair And Maintenance Of Various Electrical Appliances And Other Misc E/M Works Under Ge (Af) Srinagar
Open Tender
Indian
Jammu And Kashmir
srinagar
19-06-2023

Tender Details

Repair And Maintenance Of Various Electrical Appliances And Other Misc E/M Works Under Ge (Af) Srinagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 66000.0 /-
Tender Value
INR 33 Lakhs /-

BOQ Items

NAME OF WORK:REPAIR & MAINTENANCE OF VARIOUS ELECTRICAL APPLIANCES AND OTHER MISC E/M WORKS UNDER GE (AF) SRINAGAR.
Sl. No. Item Description
1Taking down ceiling fans of any size any sweep from site and removing to MES store for servicing like cleaning, lubricating, greasing and replacement of split pin, bearing, bush, capacitor, connection wire and refixing the fans at same location after spray painting to complete fan including blade by applying one coat of synthetic enamel paint andtesting complete all as specified and directed by Engr-in-Charge. Note :- (a) Contractor will provide one electrician and one helper for removing the faulty fan and refixing the serviced ceiling fan (b)Contractor team will report to AGE E/M Sub Div daily except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. (c)Spare parts as required will be measured & paid seperatly.
2All as per Item No 01 but Exhaust fans of any size (metal body)
3All as per Item No 01 but Exhaust fans of any size (PVC body)
4All as per Item No 01 but wall mounting / air circulator fan of any size and type
5M & L for replacement of burnt out coil of copper and aluminium winded of Ceiling fan 1200 / 1400 mm sweep working on 230 volts AC supply and rewinding complete with super enamelled copper wire of same guage and weight including, insulation paper and varnishing andtesting complete upto satisfaction of Engr-in-Charge. Note :- 1. Rewinding work shall be carried out at AGE E/M store yard or any place decided by Engineer-in-Charge.
6All as per Item No 05 but Exhaust fan 600 mm sweep working on 230 volts AC supply (metal body)
7All as per Item No 05 but Exhaust fan 400 mm sweep working on 230 volts AC supply (metal body)
8All as per Item No 05 but Exhaust fans 300 mm sweep working on 230 volts AC supply (PVC body)
9All as per Item No 05 but Wall mounting / air circulator fan of any sweep working on 230 volts AC supply
10S & F in repair fan hanging hook any type or size suitable to hang on wooden block, MS bar etc with rubber reel, nuts, bolts, split pin etc suitable for ceiling fan complete all as specified and as directed by Engr-in-Charge.
11S&F in replacement down rod made out of GI pipe medium grade 15 mm & 40 cm length with fan clamps incl drilling, cutting threading & white painting etc for ceiling fans 1200 / 1400mm sweep all as specified and directed by Engr-in-Charge.
12S & F in repairs canopyfor ceiling fans upper and bottom (Set of two) complete all as specified and directed.
13Supply and fixing in replacement by cutting sizes water proof plywood ISI Marked, 12mm thick,of required size incl necessary provisions for mounting in walls, openings and securing using fasteners 10 cms long and 8 mm dia for mounting of exhaust fans in various locations and sizes as directed.
14Taking down old unserviceable PVC ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fix ventilation / exhaust fan made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed.
15Taking down old unserviceable PVC ventilation / exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fix ventilation / exhaust fan made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed.
16Taking down old unserviceable ceiling fans after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed.
17S&F in replacement louver shutter of exhaust fan upto 400 mm size round or square as per site condition including fixing arrangement with fixing material complete all as specifed and directed.
18Supply and fix in replacement terminal connector 3 way complete all as specified and directed.
19Supply and fix in replacement capacitor 2.5 mfd 230 volts complete all as specified and directed.
20Supply and fix in replacement capacitor3.5/ 4 mfd 230 volts complete all as specified and directed.
21S&F MS screw for fixing of ceiling fan blade of any size and type complete all as specified and directed.
22S&F in replacement of fan blade suitable for 1200 mm dia ceiling fan complete all as specified and directed. Note : Blade shall be suitable for Bajaj / Crompton / Usha / Havells / Polar make fans.
23S&F in replacement of fan blade suitable for 1400mm dia ceiling fan complete all as specified and directed. Note : Blade shall be suitable for Bajaj / Crompton / Usha / Havells / Polar make fans.
24S&F in replacement of fan blade suitable for 300 mm dia PVC exhaust fan complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
25S&F in replacement ofPVC fan blade suitable for wall mounted fan 400 mm dia complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
26S&F in replacement ofPVC fan blade suitable for wall mounted fan 600 mm dia complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
27S&F in replacement ofwall mounted fan blade guard of size 600 mm diacomplete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
28Taking down and refixingceiling fan of any size after replacement of fan rod with anti suicide fan rod (12") white, MS pipe zinc plated, 19mm OD, 1.8+/-0.05mm thick, spring set grade 3 carbon steel material zinc plated, MSME tested for performance test and opening at impact load of 22 Kgf and above and spring hidden in the pipe will expand to about 1 mtr or more complete all as specified and directed. Make Safe solution industries or equivalent of make approved by GE
29Supply only ball bearing of ceiling fan of size 1200 / 1400mm sweep exactly similar as existing in fan complete all as specified and directed.
30Supply only ball bearing of exhaust fan of size 300 / 400 / 450mm sweep exactly similar as existing in fan complete all as specified and directed.
31Supply only gun metal bush of ceiling fan of size 1200 / 1400mm sweep exactly similar as existing in fan complete all as specified and directed.
32Supply only gun metal bush exhaust fan of size 300 / 400 / 450mm sweep exactly similar as existing in fan complete all as specified and directed.
33Disconnecting & taking down unserviceable geyser of 25 / 50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering / brazing /gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares,including replacement of required number ofstainless steel screws, nuts & bolts, assembling the the same after repair work and fixing inits orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified andas directed by Engineer-in-charge. Note: Spare parts and glass wool shall be measured and paidsepartaly under respective items of BOQ.
34Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
35Supply only glass wool of good quality as approved for 50 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
36S&F replacement of unserviceable Stain lesssteel inner tank of 25 liter capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.
37S&F replacement of unserviceable Stain lesssteel inner tank of 50 liter capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.
38Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 1500 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.
39All as per above item No 38 here-in-before but 2000 watt ISI marked complete and all as specified
40All as per above item No 38 here-in-before but 3000 watt 415 volts AC three phase ISI marked complete and all as specified
41All as per above item No 38 here-in-before but 4000 watt 415 volts AC three phase ISI marked complete and all as specified
42Replacement of unserviceable Geyser thermostat switch with new thermostat switch ISI marked 230 Volts 50 Hz AC of range 0-100, degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etccomplete and all as specified
43Replacement of unserviceable Geyser thermostat switch with new thermostat switch ISI marked 415 Volts(Three phase)AC of range 0-100, degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etccomplete and all as specified
44Supply and fix in repairs06 / 08 hole Assembly for water heater of cap 25 Ltr ISI Marked complate all as specified and as directed. MAKE:-Crampton / Havells / Venus.
45Supply and fix in repairs06/08 hole Assembly for water heater of cap 50 Ltr ISI Marked complate all as specified and as directed. MAKE:-Crampton/Havells/ Venus.
46S&F in replacement of safety valve ISI marked for any make and capacity complete all as specified by EIC.
47Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified
48Replacement of unserviceable 23 to 30 cm long ,10 mm boreC.P Connection with brass union
49S&F in replacement of unserviceable Gun metal non return valve ,15 mm bore
50S&F in Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe
51S&F in Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litregyser
52S&F in Replacement of unserviceable Apparatus plate for Syphon Assy for 50 litregyser
53S&F in Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.
54S&F sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt includingMCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge.
55S&F in repair metal clad industrial plug and socket 3 pole+ earth 415 Volts 40 Amp etc complete all as specified and directed by Engr-in-Charge.
56S&F in repair MCB single pole 240 Volts ISI marked of capacity 25 Amps B series complete all as specified and directed by Engr-in-Charge.
57S&F in repair MCB single pole and neutral 240 Volts ISI marked of capacity 40 to 63 Amps B series complete all as specified and directed by Engr-in-Charge.
58S&F in replacement stepped type, electronic fan regulator flush type on the existing phenolic laminated sheet etc.suitable for 1200 mm sweep ceiling fan all as specified and directed.
59S&F in replacement of 6 Amp Modular switch complete all as specified and directed.
60S&F in repair Modular switch flush type single pole one way 16 Amps, ISI marked or 240 Volts 50Hz AC complete all as specified and directed by Engr-in-Charge
61S&F in replacement of 6 Amp piano switch complete all as specified and directed.
62S&F in replacement PVC copper cable flexible 3 core round heavy duty of size 40/0.0076 suitable for fan connection of any capacity complete all as specified and directed by Engr-in-Charge.
63S&F in repair switch socket combination 5 in 1, 16 Amp flush type ISI marked 240 Volts complete all as specified and directed by Engr-in-Charge.
64S&F in repair three pin plug top ISI marked 15 / 16 Amp suitable for 240 Volts 50Hz AC complete all as specified and directed by Engr-in-Charge.
65S&F in repair socket outlet 2 in 1 5 pin 16 Amp Flush type ISI marked suitable for 240 Volts 50Hz AC complete all as specified and directed by Engr-in-Charge.
66S&F in repair socket outlet 2 in 1 5 pin 16 Amp modular type ISI marked suitable for 240 Volts 50Hz AC complete all as specified and directed by Engr-in-Charge
67S&F in repair piano switch flush type single pole one way 16 Amps, ISI marked or 240 Volts 50Hz AC complete all as specified and directed by Engr-in-Charge
68S&F in repair PVC gang box with 2 in 1 5 pin 16 Amps switch socket combination, ISI marked or 240 Volts 50Hz AC complete all as specified and directed by Engr-in-Charge
69Supply and fixing 1100 Volts grade heavy duty cable pvc insulated stranded aluminium conductor served with inner sheathing of pvc tape and used for cservice connections suspended by insulating hangers not more than 1 mtr apart of size 10 sqmm 2 core.
70S&F in repair of Rubber O ring /gaskit having suitable holes to suit the hole of base plate of geyser of cap 25 ltrs.
71S&F in repair of Rubber O ring /gaskit having suitable holes to suit the hole of base plate of geyser of cap 50 ltrs.
72M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applyingsynthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
73M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
74S&F heavy duty pin type fastner 4"" long (GI nuts and volts and washer of suitable sizes) suitable for any capacity of geyser as per site complete all as specified and directed by Engr-in-charge.
75S&F in repair storage type water heater 5 star rated50 ltrs capacity vertical wall mounting type made out of CRCA sheet outer body, stainless steel storage tank, titanium enamalled heatinh element, thermostate , thermal cutout, glass wool, incl 15 mm 450 mm long pvc connnectons etc making necessary all electric and water connections with 2.5 sqmm 3 core copper, multistranded cable with top indiacator plug top 15 Amp from geyser connection to socket incl hold fast for fixing of new geyser and writing the MES No and unserviceable geysers will be deposited in MES store yard etc complete all as specified and directed by Engr-in-Charge.
76S&F in repair storage type water heater 5 star rated 25 ltrs capacity vertical wall mounting type made out of CRCA sheet outer body, stainless steel storage tank, titanium enamalled heatinh element, thermostate , thermal cutout, glass wool, incl 15mm 450 mm long pvc connnectons etc making necessary all electric and water connections with 2.5 sqmm 3 core copper, multistranded cable with top indiacator plug top 15 Amp from geyser connection to socket incl hold fast for fixing of new geyser and writing the MES No and unserviceable geysers will be deposited in MES store yard etc complete all as specified and directed by Engr-in-Charge.
77Cutting chasing inbrick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
78S&F in repair for 15mm size long shank stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
79S&F in repairfor 20mm size stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
80S&F in repair for 20mm size stop valve cast copper alloy chromium plated fancy type, long shank cup concealed high pressure with cutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
81S&F in repairfor 15 mm borestop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
82S & F in repair for 15mm bore steel water tubingmedium grade, galvanised with all fittings and fixturefixed & concealed inwall/ceiling or laid in floors including taking out unserviceable pipe complete all as specified and directed by Engineer-in-charge.
83S & F in repair for 20 mm bore steel water tubingmedium grade, galvanised with all fittings and fixturefixed & concealed inwall/ceiling or laid in floors including taking out unserviceable pipe complete all as specified and directed by Engineer-in-charge.
84S&F in repair of outer bodyISI marked for cap 25 Ltr capacity gyser complete as specified and directed by Engr-in-Charge.
85S&F in repair of outer bodyISI marked for cap 50 Ltr capacity gyser complete as specified and directed by Engr-in-Charge.
86Taking down carefully u/s point wiring and M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etcall as specified and as directed for one switch socket outlet 15 Amps on independent board complete all as specified and as directed by Engineer-in-charge.(for Geysers connection only)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail