Tender For Special Repairs/ Replacement Of Ber Ac Plant Installed At Scme And Related Works Under Ge(Utility) Ambala Cantt, ambala-Haryana

Military Engineer Services-MES has published Tender For Special Repairs/ Replacement Of Ber Ac Plant Installed At Scme And Related Works Under Ge(Utility) Ambala Cantt. Submission Date for this Tender is 14-06-2023. HVAC Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37797162
Corrigendum : Tender For Special Repairs/ Replacement Of Ber Ac Plant Installed At Scme And Related Works Under Ge(Utility) Ambala Cantt
Open Tender
Indian
Haryana
ambala
14-06-2023

Tender Details

Special Repairs/ Replacement Of Ber Ac Plant Installed At Scme And Related Works Under Ge(Utility) Ambala Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2023 Amendments to tender documents Other 07-06-2023
2 27-May-2023 Date 1 Date 07-06-2023
3 27-May-2023 Amendments to BoQ BOQ 07-06-2023
4 07-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 69600.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIRS/ REPLACEMENT OF BER AC PLANT INSTALLED AT SCME AND RELATED WORKS UNDER GE(UTILITY) AMBALA CANTT (Retender)
Sl. No. Item Description
1SCHEDULE A PART I (BER AC PLANT) Supply, installation, testing & commissioning of central AC Plant having Nominal Capacity not less than 22 TR(2 x 11 TR + 1 x 11 TR Stand By) water cooled, scroll type, chiller units with Hemetically Sealed Scroll Compressors and other accessories of AC Plant, complete as per detailed specifications in particular specifications here-in-after, complete all as specified and directed. Note:-(i) The Unit shall have Compressor mounting arrangement on Rubber Grommets with metal sleeves, water cooled shell & tube type condenser, Dx type Evaporatorduly insulated, thermostatic expansion valve with Extl. Equalizer. Unit shall have filter dryer, pressure switch i.e HP/LP, Electronic, thermostat, flow switch at chiller, integral Refrigerant piping & wiring, accessories as required and called for Automatic and safety control mounted in central console electronic, microprocessor with internal overload protector. (ii) The central AC Plant shall comprises all the accessories/equipments as specified in Particular Specification here-in-after for making plant functional and quoted rate shall be deemed to be included for the same.
2SCHEDULE A PART II (INTERNAL ELECT WORKS) Taking down carefully any type of point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, tube light fittings with all accessories etc., and/or drawing out from existing conduit/batten and removal of materials from site and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
3Material and labour for point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 Volts grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25mm dia with accessories, concealed on wall/ ceiling and including1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 Volts grade stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with and including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal confirming to IS-5139 (Pt-I) of 1969 and IS: 14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including new 3mm thick plastic laminated sheet top cover extended up to 25mm over sunken box all around for housing the switches, socket outlet, fan regulator etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/ fan point controlled by one switch complete all as specified and directed. Notes :- (i) Switch, socket, lamp holder, ceiling rose and fan regulators to be measured and paid for separately. (ii) PVC Conduit shall conform to IS 9537 part I & III. (iii) All chases will be cut by chase cutter only.(iv) The concealed conduits and MS boxes shall be verified by Engineer-in-Charge before making good the surfaces by plastering and other finishes.
4Description all as per Srl item No. 3.00 here in before but for one 3 pin socket outletpoint 5 Amp on Independent board.
5Description all as per Srl item No. 3.00 here in before but for one 3 pin socket outlet point 5 Amp on same board.
6Description all as per serial item No.3.00 above, but for one socket point 3 pin 16 and 6 Amps (independent) power point, with 2.5 SqmmPVC, FRLS-H, unsheathed, multistranded cable, 1100 volts grade, ISI marked, including 2.5 Sq mm size, green colour, PVC insulated FRLS-H, continuous copper earth wire and connected to common earth dolly complete all as specified and as directed.
7Supply and fixing of switch piano, 5 Amps, flush type, single pole, one way,230 volt, AC supply, ISI Marked complete all as specified and directed.
8Supply and fixing of switch piano, 15 Amps, flush type, single pole, one way,230 volt, AC supply, ISI Marked complete all as specified and directed.
9Supply and fixing of socket outlet, 3 pin, single pole, 5 amps, 230 volts, flush type, ISI Marked complete all as specified and directed.
10Supply and fixing of socket outlet, 2/3 pin, single pole, 15 amps, 230 volts, flush type, ISI Marked complete all as specified and directed.
11Supply and fixing of ceiling rose surface bakelite 65x50mm, three terminals complete all as specified and as directed.
12Supply and fixing in replacement LED tube light channel for 18-20 watt tube light fitting, 4 ft, aluminium housing body, with and including 18-20 watt LED tube rod , with drivers, 220-240 Volt, 50 Hz connecting up with 2/3 core 1.5 sq mm flexible copper conductor cable from ceiling rose to connector block of light fitting including disconnecting complete all as specified and directed.
13M&L for sheet metal enclosure MCB DB, SPN, 240 volts, 4 way, double door IP-43 protection IK-09 with metal door with neutral bar, earth bar and cables ties for cable management fully insulated bus bar, grouting in wall in CM, making good of disturbed surfaces and matching with existing and electrical connections complete all as specified and directed.
14S&F MCB SPN, 220 volt , 50 Hzs, 20 Amp, 10 KA , "B" series for AC complete all as specified and directed.
15S&F MCB SP, 220 volt , 50 Hzs, 6 to 40 Amp, 10 KA , "B" series complete all as specified and directed.
16Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers including making opening in existing wall suitable for fixing in exhoust fan and grouting of bolts of suitable size complete all as specified and directed.
17Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
18Material and labour for new earthingwith galvanised earth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 4.00 mm GI wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire and thimbles protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in Electrical Plate No.3 of SSR Part-I & including necessary excavation and earth work in any type of strata, PCC (1:3:6) type C1 in pit, RCC cover slab 50mm thick in 1:2:4 type B-1 using 8mm dia TMT bars @10cm c/c both way with one 8mm dia bar as handle for lifting, 20mm dia GImedium grade watering pipe, funnel, wire wesh, charcoal or coke & salt in alternate layers, etc.all as indicated including testing on completion complete all as specified and directed. Note:- The new earthing shall be provided adjecent to old earthing site on the locations as directed by engineer in charge.
19SCHEDULE A PART III (B/R WORKS) Dismantlingof Brickworkor stone masonary ,precast cement concrete walling built in cement mortar including all quioins, arches, pillars etc including removal of debries and stacking of servicable bricks complete all as specified and as directed.
20M & L for brickwork with subclass `B’ old size bricks (except bricks), in straight or curved on plan exc 6m mean radius, built in cement sand mortar 1:6 complete all as specified and as directed. Note: Old bricks obtained from item No. 19 here-in-above shall be reused after cleaning and washing.
21Taking down chowkats or frames with shutter, areanot exceeding 1.50 Sqm(w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs andadjoining surfacesin CM (1:3) and finishing the surfaces to match with existing finish including removal of serviceable/unserviceable material from site complete all as specified and directed.
22Taking down chowkats or frames with shutter, areaexceeding 1.50 Sqmbut not exceeding 4.00 Sqm (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs andadjoining surfacesin CM (1:3) and finishing the surfaces to match with existing finish including removal of serviceable/unserviceable material from site complete all as specified and directed.
23M & L for PCC 1:2:4 type B1 (using 20 mm graded aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth, string, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
24Supply and fixing for aluminium alloy anodized (powder coated) door frame and shutters with hollow aluminium anodized sections as specified including aluminium alloy anodized snap type beads, dish type door handles of suitable size as per door, glazed clip joints cleats,rubber gasket ,dead lock 4 levers,two numbers of aluminium alloy anodized tower bolts 150mm to each leaf etc, hinges including fixing frame to wall/RCC members with rawl plugs complete all as specified and directed. Sections of doors shall be aluminium hollow sections as follows:- (a) Door frame single groove 101.6 mmx 2.15 mm thick, (b) Shutter top 47.62 mm x 44.45 mm x 1.95 thick, (c) Shutter bottom 114.30 mm x 44.45mm x 2.15 mm thick, (d) Shutter vertical 85 mm x 44.45 mmx 1.80 mm thick, (e) Shutter middle 83.5 mm x 44.45 mm x 2.40 mm thick, (f) Gauging clip weighing not less than 0.097 kg/metre. Note:- Sheet glass, sheet panel and door closer shall be measured and paid separetely.
25Supply and fixing for aluminium alloy anodized (powder coated) window frame with double shutters (gauzed and wire gauge) openable type, with aluminium sections as per of "Jindal" section numbers for casement windows with double shutters including aluminium alloy anodized snap type beads, aluminium handles 150mm 02 nos on each leaf ,aluminium anodized barrel tower bolts 150mm 02 nos on each leafand glazing clip, jointcleats,rubber gaskets,etc, complete all as specified for series-B " Jindal" section number of casementincluding hinges including fixing frame to wall/RCC members with rawl plugs complete all as specified and directed. Sections of doors shall be aluminium hollow sections as follows:- (a) frame of section 101.6mm x 44.45mm x 2.10 mm thick and section for shutter 47.62x44.45x1.95 mm thick, (b) Mullion 52 mm x 52mm x 2mm thick not less than 1.065 kg/mtr, (c) Glazing clip weighing 0.259 kg/mtr, (d) Windows shall be provided with 02 Nos of tower bolt for single leaf and 03 Nos. of tower bolts for double leaf of size 150mm. Tower bolts shall be aluminium alloy anodized weighing 0.302 kg/mtr. Note:- Sheet glass & wire guage shall be measured and paid separetely.
26Supply and fixing aluminium alloy anodized (powder coated) parttition (area of each panel not exceeding 1.5 Sqm each) with frame of size less 100 mm x 44.4mm x 2mm complete packing with rubber gasket, standard aluminium beading, etc around both sides including 6 mm thick plain coloured bakelite sheet oracrylic boards, prelaminated both side with one one side decorative choice lamination for fixing in panels of aluminium partition as required complete all as specified and directed.
27Supply and fixing aluminium anodized grill 5.5mm thick weight not less than 2.5 kg per square metre (in the shape of Sqm expanded metal aluminium xpm jalli) opening size length of expansion (60 mm) and width expansion 45 mm fixed in aluminium anodized window with "F" channnel of handle section with screw, complete all as specified and directed.
28Supply and fixing 6 mm thick plain coloured bakelite sheet pre laminated both side with decorative choice lamination or acrylic boards for fixing in panels of aluminium doors,complete all as specified and directed.
29S &F sheet glass 5.5mm thick, ordinary quality fixed in aluminium door/window complete all as directed
30S & Fhydraulically regulated door closer,aluminium body, designation No. 1, universal type, suitable for shuttersof weight more than 35 kg complete all as specified and as directed.
31S & F in repair steel rolling shutters without ball bearing of push pull or manual type as specified, including top cover, anchoring rod, hasp & staple and one shop coat of primer; erected in position as indicated complete all as specified and as directed.
32M & L for two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer including preparation of new steel surfaces of any description not other wise described over 10cm width or girth complete all as specified and as directed
33M & L preparing surface of wood and wood based materials,new steel surface,iron surface treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats etc., area n exc 0.1 sqm each and treated with coal tar black paint, complete all as specified
34M & L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
35Material and labour for premium quality, joint free, printed glazed coloured designer ceramic tiles of size 300 x 450 x 7mm thick on vertical surfaces of walls over and including 10mm thick rough finished plaster in cement mortar (1:4), and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface complete all as specified and directed.
36M & L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified
37M & L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded mechanically crushed stone aggregate) as in sub base to floor, complete all as specified and as directed
38M & L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in bedding layer under floor surface finished even and fair complete all as specified and as directed.
39M & L for machine cut kota stone slab flooring 18-20 mm thick (of size not less than 55cm x 55cm) laid in glooring and jointed & pointed with grey cement sluurymixed with pigment to match the shade of the slab including cutting waste,rubbing and polishing(Granite finish) over and including cement screen bed15 mm thick in cement mortar (1:4) base, complete all as specified
40M & L for 50 mm thick PCC1:3:6 type C-1 (using 20mm graded mechanically crushed stone aggregate) as in plinth protection/PCC path, and paving, finished the surface even and smooth without using extra cement, joint filled with bitumen and sand mixture applied hot complete all as specified and directed.
41M & L for taking down cement of cement lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
42M & L for rendering 15mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed .
43Material and labour for rough cast plastering over and including 10mm thick rendering in CM 1:4 mixed with WPC complete all as specifiedin Clause14.22 of MES Schedule Part-I and as directed. Note: 1.Rough cast finish shall be provided as under:- After applying under coat of CM 1:3 and while it is still in plactic state the rough cast mixture consisting of crushed stone or fine aggregate (which is generally of size between 4 to 8 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall be made slightly loose/wetter than normal for rendering to ensure that larger aggregates are thoroughly covered.2. Contractor"s quoted rate shall include all above provisions and no extra shall be admissible on this account. 3. WPC shall be measured and paid separately.
44Supply only Integral water proofing compound complete all as specified.
45M & L for preparation of new plastered surfaces and applying three coats of white wash on wall complete al as specified.
46M & L for two coats of cement base paint over newly plastered surface including preparation of surface complete all as specified and directed.
47M & L for two coat of white washing on old plastered surface ofceilings including preparation of ceiling surface complete all as specified and as directed
48Note:-Amount of credit ofRs. 3450.00 for retrieved materials is mentioned in Schedule of Credit Page No. 16 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Disclaimer :