Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-06-2023 | DATES AND TENDER DOCUMENTS CORRIGENDUM | Date | 27-06-2023 |
| 2 | 16-06-2023 | BOQ | BOQ | 27-06-2023 |
| 3 | 12-06-2023 | DATE CORRIGENDUM | Date | 26-06-2023 |
| 4 | 06-06-2023 | CRITICAL DATES | Date | 20-06-2023 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tilling including cement mortar bedding ( but not backing), removing serviveable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness ( below or above ground level).complete all as specified and directed. |
| 3 | M&L PCC type B2 ,1:2:4(40mm graded aggregate) , 50mm thick as in floor complete all as specified and directed. |
| 4 | M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laidand jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed or bedding layer in CM 1:6 for laying kota stone slab complete all as specified and directed. |
| 5 | M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed and provision of 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 6 | S&F Vitrified Ceramic tiles double charged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match15 mm thick screed bed in CM 1:4.(Shade of tile shall be approved by GE) complete all as specified and directed. |
| 7 | S&F Vitrified Ceramic tiles double charged 8-9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, as in skirtings/dados etc. and jointed in neat cement slurry and pointed inwhite cement to match the colour over 10 mm thick rendering in CM 1:4.(Shade of tile shall be approved by GE).complete all as specified and directed. |
| 8 | M&L non skid ceramic tiles coloured7 to 8mm thick (square or rectangular) area of each tile exc. 0.11 Sqm but not exc 0.16 Sqm in floors set and jointed in neat cement slurry and pointed inwhite cement to match the colour over 20 mm thick screed bed in CM 1:6.complete all as specified and directed. |
| 9 | M&L glazed ceramiccoloured tiles (450x300)x7 mm thickmm in skirting/dado set and jointed in neat cement slurry and pointed in white cement to match the surface over 10 mm thick screed in CM 1:4 .complete all as specified and directed. |
| 10 | Taking down cement motarplaster on brick or stone wall etc, including raking out joints, hacking for key, scrubbingdown with water etc. complete all as specified and directed. |
| 11 | M&L for rendering 10 mm thick on other than fair faces of brick work or other side of lathing in cement mortar 1:6 , surface finished even and smooth without using extra cement complete as directed. |
| 12 | M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in two coats (first coat 10 mm thick incm 1:4 and second coat 5 mm thick cement mortar 1:4, using liquid water proofing compound, finished fair & evenw/o using extra cement ( WPL shall be measured and paid seaperatly )etc. complete as directed. |
| 13 | M&L rendering 5 mm thick cement plaster in cement mortar (1:3) on brick/concrete surfaces on ceiling finishedeven & smoorhcomplete all as specified and directed. |
| 14 | Supply only liquid water proofing compound |
| 15 | M&L granite (of any type) 18 to 20mm thick as in floor bedded and jointed in cement slurry over 20mm screed in CM 1:4 and pointed in cement with pigment to match the shade of granite.complete all as specified and directed. |
| 16 | M&L granite (of any type) 18 to 20mm thick as in skirting/ dado laid over cement screed and jointed within cement slurry over 10mm plaster in CM 1:4 and pointed in cement with pigment to match the shade of granite complete all as specified and directed. |
| 17 | Demolition of stone slabs and tiles of any description or thickness in floors, skirting, dado etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 18 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of graniteincluding 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 19 | M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 20 | M&L for Providing edge moulding on Granite stone to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed. |
| 21 | Taking down chowkat or frame with shuters ( without taking off shutter from the frame) area n.exc 1.50 Sqm each complete all as specified and directed. |
| 22 | Taking down chowkat or frame with shuters ( without taking off shutter from the frame) area exc 1.5 Sqmand n. exc 4.00 Sqm each complete all as specified and directed. |
| 23 | S&F IInd Class Hardwood plain solid stright chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 24 | M & L pressed steel frame 1.25 mm thick (size of frame 105 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate ,hold fastetc complete all as specified incl. |
| 25 | M&L for plain cement concrete Type C1, 1:3:6 ( using 20 mm graded aggregate) for filling of hollowpressed steel frame complete all as specified and directed. |
| 26 | S & F 25 x 3mmF1 hold fast conforming to Fe 290, Gde -E-165 complete all as specified and directed. |
| 27 | M&L for plain cement concrete Type B-0 1:2:4 ( using 12.5 mm graded stone aggregates) for fixing hold fast including repairing of disturbed plaster (while taking down Door/window,ventilator frame) and matching the repaired surface with existing one complete all as specified and directed. |
| 28 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube all as specified and directed. |
| 29 | S&F anodised aluminium frame with poweder coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators/Partationswith one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 30 | S&F anodised aluminium window (three track) and ventilator shutters poweder coated with poweder coating (minimum thickness of powder coating 50 micron) without sash bar including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 31 | S&F Sheet glass 4.80mm ordinary qualit and glazing with oil putty in square exc 0.5 sq. m in each pane fixed to window shutter including rubber bubber packing complete all as specified and directed. |
| 32 | S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 33 | S&F Figured glass, pin head type 4mm thickand glazing with oil putty in squares n exc 0.5 sq. m in each pane including rubber bubber packing complete all as specified and directed. |
| 34 | S&F Factory made solid panel PVCdoor shutter 30mm thick (Style) consisting of frame made out of ms Tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" chanel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading,and jointed together with solvent cement, supplying and fixing in the frame at site.complete all as specified and directed. |
| 35 | S&F 100mm butt hinges extruded aluminum alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed.. |
| 36 | S&F 150mm size extruded alluminium alloy handle fabricated type anodaised complete all as specified and directed. |
| 37 | S&F 150mm long alluminium anodaised barrel tower bolt of extruded section complete all as specified and directed. |
| 38 | S&F 200 mmsize Length alluminium alloy anodised sliding door bolt with hasp & staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast alluminium alloy complete all as specified and directed. |
| 39 | Dismantling boarding, any description, fixed any position with nails complete all as specified and directed. |
| 40 | S & F5.5 mm thick sheet glass tinted in squres exc 0.5 sqm each pane complete all as specified and directed. |
| 41 | S & F12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 42 | S & F brass bodydoor stopper of size140 mm long double legged fixed to bottom rail of door shutter provided with rubber bushing at one end to stop the door at floor and other end provided with aluminium plate base fixed with door shutter with screws at appropriate height complete all as specified and directed. |
| 43 | S&F 35mm thick factory made flush shutters, solid, core construction with black board core and plywood face panals commercial type on both sides covered with decorative face veneer with lipping / frame to matchcomplete all as specified and directed. |
| 44 | Taking down shutter of any description areaexc. 1 Sqm and n.exc. 2 Sqm complete all as specified and directed. |
| 45 | Taking down shutters of any description exc 2 sq. m each complete all as specified and directed. |
| 46 | S&F collapsible steel gates, top hung, consisting of channel pickets, pivot flat bars, top and bottom runners, brass handles etc as specified erected in position and securing with holdfasts and brackets complete all as specified and directed. |
| 47 | S&F powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screwsetc.complete all as specified and directed. |
| 48 | S&F For 100 mm butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 etc. complete all as specified and as directed. |
| 49 | S & F For 150Extruded brass handles, fabricated type polished etc. complete as directed. |
| 50 | S & F For 150 mm brass barrel tower bolts, with cast or sheet barrel and rolled or cast boltsetc. complete as directed. |
| 51 | S & F in repair 300 mm length brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts etc. complete all as specified and directed. |
| 52 | Dismanintling wall and ceiling boards ( fibre, pulp, insulations, etc. ) or insulation boards/ siabs/ blankets, any thinkes, including cover fillets etc. complete as directed. |
| 53 | Providing & Fixing of Armstrong Soft Fibre Acoustical Suspended Ceiling System with fine fisuured bev 600x600x16mmamtwith suprafine 15mm grid With Armstrong 15mmExposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance =85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW & 74% RW. The tile shall be laid on ArmstrongSuprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.5Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system complete all as specified and directed.The Tile & Grid system used together should carry a 10 year warranty. |
| 54 | S&F For 75 mm, rim latch two levers of brass body stove enamelled finish, with brass knob or lever handle etc. complete all as specified and directed. |
| 55 | S&F 65 mm ,mortice latch with two levers (vertical type),brassbody complete all as specified and directed. |
| 56 | Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 57 | Taking up or down 20 mm bore steel water tubing & connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 58 | S&F 15mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified and directed. |
| 59 | S&F 20 mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified and directed. |
| 60 | Cutting chases, pinning in, making good to facings where required & plastering in cement mortar 1:3 for concealed water tubing or concealed conduit wiring, etc.& making good, cutting n.exc 10 cm grithin brick/ concrete surfaces.complete all as specified and directed. |
| 61 | Dismantling existing tanks and removing to store of capacity exc 250 ltr n.exc 500 ltrs complete all as specified and directed. |
| 62 | S&F rotational moulded polyethylene water storage tanks (cylindrical verticla with closed top) hoised and fixed in position all as specified in SSR Part I of capacity 500 ltrs complete all as specified and directed. |
| 63 | S&F 20mm bore ball brass valve, high pressure with polythene float & fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 64 | S&F in repair 20 mm dia. Gun metal, globe or gate valves, with iron wheel head, both ends for pipe etc. complet as directed. |
| 65 | S&F in repair 15 mm dia. Gun metal, globe or gate valves, with iron wheel head, both ends for pipe etc. complet as directed. |
| 66 | S&F vitreous china wash down water closet pan (pedestal pattern) white including conection to flush pipe and out going pipe and plastic watercloset seat cover closed pattern with flat bottom and mild steel CP hinging device complete fixed in repairs.complete all as specified and directed. |
| 67 | S/F in repairPVC valveless, syphonic action type, flushing cistern HDPE Dual flush 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 68 | S&F in repairwash hand basin, Vitreous China oval shaped, first quality, white colour, of size 580 mm x 450mm x 175mm, including cutting for and pinning in ends of brackets or erecting stand, with and includingCI brackets, PVC flexible pipe with both side brass nuts to joint and 750mm long PVC waste pipe 32mm dia, CP waste coupling with long screwed shanks and fly nuts, fixed in repairs, complete all as specified and directed. |
| 69 | S/F 32mm bore waste fittings, brass chromium plated for glazed sinks, WHBs etc, with long screwed shanks and forming flange and bedded in red lead cement and other end fixed complete all as specified and directed. |
| 70 | S/F LDPE pipe 32mm bore of pressure rating 6 Kgs/Sqcm fixed complete to walls, ceiling or in floors complete all as specified and directed. |
| 71 | S&Fin repairstopvalves, cast copper alloy, chromium plated, screwed down, high pressure, with cruth or butter fly handle, screwed both ends for iron pipe orfor unions, 15mm bore.complete all as specified and directed. |
| 72 | S&F in repairs 15mm bore fancy type chromium plated bib taps with crutch or butterfly handle screwed down for iron pipes complete all as specified and directed. |
| 73 | S&F in repairs vitreous china urinal, Half stall type white, with grating and union etc complete all as specified and directed. |
| 74 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 75 | S&F Forin repair 15 mm concussive push button taps of cast copper alloy, screwed for iron pipe complete all as specified and directed. |
| 76 | S&F in repair 15mm borefancy type, pillar taps, castcopper alloy, with capstain heads, chromium plated, screwed down high pressure with long screwed shanks, and flynuts, screwed for iron pipe complete all as specified and directed. |
| 77 | S&F in repair600mm x 450mmmirror of selected quality glass, mounted on PVC white frameor6mm thick AC building board or commercial plywood and fixed to wooden plugs withchromium plated brass screws and cup washersas directed by Engr in Charge. |
| 78 | S&F For in repairPVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 79 | S&F For sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with stain steelbracket guard and railing 60 cm long etc. complete all as specified and as directed. |
| 80 | S&F towel rail \"D\" type 600mm long of stainless steel.complete all as specified and directed. |
| 81 | Dismantling and breakingup drain pipes AC /CI /PVC set in cement mortar 100mm/75mmbore complete all as specified and directed. |
| 82 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed. |
| 83 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or floor75mm bore complete all as specified and directed. |
| 84 | S/F 110mm bore P.V.C (S.W.R) bend complete all as specified and directed. |
| 85 | S&F in repair 110 mm PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 86 | S&F in repair 110mm bore PVC (SWR) branch piece, single `Y’ equal or un equal with access door complete all as specified and directed. |
| 87 | S/F in repair 110mm bore P.V.C vent cowl complete all as specified and directed. |
| 88 | S/F in repair 75mm bore P.V.C (S.W.R) bend with access door complete all as specified and directed. |
| 89 | S&F in repair 75 mm PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 90 | S&F in repair 75 mm bore PVC (SWR) branch piece, single `Y’ equal or un equal with access door complete all as specified and directed. |
| 91 | S&F For framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 etc. complete all as specified and as directed by Engr - in - Charge. |
| 92 | Demolition of cement concrete (un-reinforced)in roof/floors other than ground level beam, stair case, landing, chajjas and similar itemsin cluding water proofing treatment in any layersand removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed. |
| 93 | Demolition of RCCof any description specifically provided for complete all as specified and directed. |
| 94 | Material and labour for mechanical cleaning of surface to make it free from any bituminous residue/ dirt, oil , Greece or similar material. Thereafter crack treatment by cutting open cracks and cleaning based sealant including application of Pu based primer all as directed Garrison Engineer/Engr-in-Charge. |
| 95 | Material and labour for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of epoxy primer @ 0.15 Kg per Sqm followed by two coats of polyurethane coating with 1.5 Kg per sqm in two coats etc complete per manufacturer specification and as directed by Garrison Engineer/Engr-in-Charge. |
| 96 | Notes : For sr item no 94 & 95. Properties of Polyurethane based chemical shall confirm to following Technical Parameters:- (i) Highly Elastic and shall have crack bridging ability of upto 3mm as per AS NZ 4548 (ii) UV Resistance. (iii) Adhesion to concrete and shall resist 7 bars of hydrostatic pressure. (iv) Tensile strength should not less than 2.0 N/sq.mm for free film & 60 % solid content as per ASTM C 1250 (v) Elongation should not less than 300% as per ASTM D2370 (vi) Solid content by weight should not less than 60%. (vii) Air/water permeability BSEN 12390 AT 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm. (viii) Accelerated weathering (ASTM453) should Pass 1000 hours. (ix) Reaction to fire – non inflammable. 2. The work shall be executed thru auth applicator of manufacturer only. Contractor has to provide manufacturer test certificates for the above mentioned technical parameters and PVs 3. The contractor has to submit the guarantee for 10 Years against the water proofing treatment. |
| 97 | M&L for PCC M-20 grade (1:1.5:3) with slope 1:100 ( using 12.5 mm gdd agg) as in levelling course using liquid water proofing compound. ( WPL shall be measured and paid seaperatly )etc. complete as directed |
| 98 | M&L 75 mm thick PCC type C2 1:3:6 in plinth protection all as specified cement concrete even and smooth without using extra cement complete all as specified and directed. |
| 99 | M&L for preparation of newly plasteredsurfaces and applying twocoat of distemper oil emulsionover and includund and a coat of primer on wall complete all as specified and as directed by Engr -in- Charge. |
| 100 | M&L fornewly plastered surface ofwall and applying two coat of exterior emulsion over a coat of primer after preparation of surfaces at any height including necessary scafolding etc complete all as specified and as directed by Engr in charge. |
| 101 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash.complete all as specified and directed. |
| 102 | M&L Complete removal of existing treatment on walls and applying two coat of plastic emulsion with roller finish over a coat of primercompleteall as specified and directed. |
| 103 | M&L for complete removal of existing treatment on wall and applying two coat of exterior emulsion over a coat of primer after preparation of surfaces at any height including necessary scafolding etc complete all as specified and as directed by Engr in charge. |
| 104 | M&L for preparation of surfaces on old surface ofceilingand applying two coatswhite washandcomplete all as specified and directed. |
| 105 | Taking down old unservicable rolling shutter compelete all as specified and directed. |
| 106 | S&F in repair 1.0mm thick steel rolling shutters, gear perated type with bevel gear box and crank handle including ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete: includingSafety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 107 | S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 108 | S&F ball bearing for rolling shutters complete all as specified and directed. |
| 109 | M&L for painting, two coats with synthetic enamel painton old steel surfaces of any description over 10cm width or girth and including preparation of surfaces complete all as specified and directed. |
| 110 | M&L for PCC 1:4:8 type D2, 75mm thick using 40mm graded aggregate as in sub base complete all as specified and directed. |
| 111 | M&L for PCC 1:2:4 type B-2, 100 mm thick using 40mm graded aggregate as infloor finish, surface finished even and broom finsh without using extra cement etc complete all as specified and directed. |
| 112 | S &F glass dividing strips, 3mm thick and 22 mm width, inserted in position, conform to design etc. complete all as specified and as directed. |
| 113 | M&L for cement concrete type D2 (1:4:8) (Using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all specifed and directed. |
| 114 | M&L for grit cushioningbelowinterlocking paver block incl spreading and levelling complete all as specified and directed. |
| 115 | M&L 60 mm thick rubber moulded glossy finish machine pressed precast concrete interlocking paver blockwith grey cement and pigment any shape and size confirming to IS 15658-2006 of M-35 gradecomplete all as specified and directed. |
| 116 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to steel trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165etc. complete all as specified and as directed by Engr - in - Charge. |
| 117 | S&F For mild 5 to 10 mm dia. of neck ,steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long etc. complete all as specified and as directed by Engr - in - Charge. |
| 118 | S&F For Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 119 | Excavation in trenches n exc 1.5 m wide and n exc 1.5 m depth for foundation and getting out soft/disintegrated rock complete all as specified and directed. |
| 120 | M&L PCC (1:3:6) type C-2 using 40 mm graded stone agg as in fdn filling mass concrete complete all as specified and directed. |
| 121 | M&L for walling of random rubble, brought upto course, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and directed. |
| 122 | Extra over stone walling granite of trap stonefor hammer dressing with maximum depression not exc 40 mm from face from strainght edge to face stones and dressing of face beds and joints as specified of random rubble walling uncoursed or brought upto course complete all as specified and directed. |
| 123 | M&L for Keyed pointing in CM 1:4 to random or polygonal rubble, uncoursed or brought upto course complete all as specified and directed. |
| 124 | M&L forold size bricks with fly ash bricks straight orcurved on plan exc. 6m mean radiusand setting in cement mortar 1:6 etc complete all as specified as directed. |
| 125 | M&L 20 mm tick damp proof course to horizontal or vertical surfaces including necessary formwork in CM 1:2 with using WPC (WPC shall be measured and paid separately) complete all as specified and directed. |
| 126 | M & L 10mm thick rendering in cm(1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 127 | Rendering 15mm thick in two layers on fair faces of brick work or concrete surfaces 10mm in CM 1:6 and top layer in CM 1:4 mixed with integral water proofing compound finished as sand plaster complete all as specified and directed. |
| 128 | Excavating over areas, n exc 1.5 m deep and getting out soft/disintegrated soil complete all as specified and directed. |
| 129 | M&L for removing excavated material exc. 250 m but n exc. 500 m and depositing where directed |
| 130 | M&L for forming embarkment including raising (or lowering) earth spreading in layer n .exc 30 cm thick watering, ramming/rolling and finishing to required size and slope etc n exc 1.5 mtr highfrom base complete all as specified and directed. |
| 131 | Removing excavated material soft/disintegrated rock n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 132 | Returning filling including sperading, levelling watering and well raming in layer n exc 25 cm complete all as specified and directed. |
| 133 | M&L Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base 75mm thick all as specified and directed. |
| 134 | M&L 100 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) and finishing cement concrete surface even and smooth with using extra cement complete all as specified and directed. |
| 135 | M&L PCC 1:3:6 type C-2 75 mm thick as using 40mm graded aggregate asin plinth protection /pavement even and smooth with using extra cement complete all as specified and directed. |
| 136 | S&F Roof trusses (framed), trussed, purlins, post, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats Fe-410 W (Gde-E-250) quality A complete all as specified and directed. |
| 137 | S&F For Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 138 | Preparation of newly steel surfaces exc 10 cm width or grith and applying 2 coats of synthetic enamel paint over red oxide. includings preparation of new surface complete all as specified and directed. |
| 139 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 140 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 141 | Dismantling fencing wire mesh, any type and ay description.complete all as specified and directed. |
| 142 | Excavating in post holes (or similar holes) and getting out softany type of soil, each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 143 | S &FMS angle, as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe - 290, Gde E- 165 etc. complete all as specified and as directed.by Engr. - in - Charge. |
| 144 | S&F in repair galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured) |
| 145 | Supply only rust proof PVC coated chain link fencingof any size and guage approved by GE conforming to IS 2721 complete all as specified and directed |
| 146 | Fixing only chain link fencing including line wires, any mesh, size and type to anytype of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 147 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. complete all as specified and as directed by Engr - in -Charge. |
| 148 | M&L for painting, two coats with synthetic enamel paint Surfaces of any description, n.exc 10cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 149 | Taking down point wiring light / fan / plug / bell / power point on teakwood batten / in surface conduit / in PVC casing and capping along with batten / conduit / casing caping with all accessories and all fittings / fixtures such as switches, socket out lets, bell push, lamp holder, ceiling roses, regulators and making goodthe disturbed surfaces of walls / ceilings including colour wash to match the existing surface complete all as specified and directed. |
| 150 | Taking down HPSV/ MH /FTL fittings any watt any size and kept safe custody for further disposal as directed by Engineer - in - Charge |
| 151 | Taking down main switches & DBs etc and making good to the disturbed surfaces all as directed by Engineer-in-Charge. |
| 152 | Taking down ceiling fans / exhaust fan of 1200/1400 mm sweep, with dismantaling fan blades and serviceing of ceiling fan / Exhaust fan cleaning, oiling, greasing & painting External body with blades including refixing at the same location after completion of work complete all as specified and directed. |
| 153 | M&L point wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand FRLS copper conductor cable concealed in wall including PVC conduit of suitable size with all fittings and accessories for mounting fittings like switches, sockets and fan regulators etc at any height including one continous run of PVC insulated green colour 1.5 sqmmmulti stranded FRLS copper conductor cable earth wire and connected to common earth dolly including chasses cutting and switch/ sockets/ Bell push any type, MS sunken box and board of hylam sheet complete all as specified and directed for the following, |
| 154 | (a) one light/fan point controlled by one, one way switch. |
| 155 | (b) one Bell point controlled by one bell push switch |
| 156 | (c) one 3 pin socket outlet 5 Amp (independent) point controlled by one, one way switch. |
| 157 | (d)one 3 pin socket out let 5 Amp point on the same board with other switches. |
| 158 | Ditto-All as per item No-152 above but with 2.5Sqmm wire for 15 Amp socket outlet and one run of green colour for earth wire 2.5 sqmm as specified and directed. |
| 159 | S&F ceiling rose 3 terminal 240 volts, 5 Amps. Make Anchor / Vinay / Leader |
| 160 | Supply & fix MCB DB, double door,8 way, TPN with 250 Amp rated busbar, 415 V with provision for Incomer MCCB up to 125 Amps complete all as specified and directed. |
| 161 | S&F MCCB 4 pole, 125 Amps36 KA ,440 Volts as Incomer complete all as specifed and directed |
| 162 | Supply & fix MCB DB, double door,4 way, TPN with 200 Amp rated busbar, 415 V.complete all as specified and directed. |
| 163 | Supply and fix MCB DB, double door, 6 way, SPN with 200 Amp rated busbar, 240V.complete all as specified and directed. |
| 164 | Supply and fix MCB DB, double door, 8 way, SPN with 200 Amp rated busbar, 240V.complete all as specified and directed. |
| 165 | S&Fin repairs MCB, SPN16 to 40 Amps10 KA, 240 with of C curve characteristicsseparate termination provision of cable and busbar both and DIN facility at both ends |
| 166 | S&Fin repairs MCB triple pole and nuetral 415 volts, 32 to 63 Amps, rupturing capacity 10KAof C curve characteristics with separate termination provision of cable and busbar both and DIN facility at both ends complete all as specified and directed by Engineer-in-Charge. |
| 167 | S&F in repairs MCB, SP, 6 to 32 Amps of C curve characteristics with separate termination provision of cable and busbar both and DIN facility at both ends complete all as specified and directed. |
| 168 | M&L for sub main wiring complete with2 single core cable4 sqmmPVC insulatedFRLS stranded copper conductor cable 1100 volts grade drawn through PVC conduit / PVC casing caping with one run of PVC insulated FRLS cable 4 sqmm copper conductor cable ( green in colour ) for earth continuity conductor connected to main earth dollyincluding taking down existing sub mainwiring complete all as specified and directed. |
| 169 | M&L for sub main wiring complete with2 single core cable6 sqmmPVC insulatedFRLS stranded copper conductor cable 1100 volts grade drawn through PVC conduit / PVC casing caping with one run of PVC insulated FRLS cable 6 sqmm copper conductor cable ( green in colour ) for earth continuity conductor connected to main earth dollyincluding taking down existing sub mainwiring complete all as specified and directed. |
| 170 | M&L for sub main wiring complete with4 single core cable10 sqmmPVC insulatedFRLS stranded copper conductor cable 1100 volts grade drawn through PVC conduit/ casing caping with two run of PVC insulated FRLS cable 6.0 sqmm copper conductor cable ( green in colour ) for earth continuity conductor connected to main earth dollyincluding taking down existing sub mainwiring complete all as specified and directed. |
| 171 | S&F in repairs LEDtube light fitting 2X18 W,4 feet long wall mounted anodized aluminum extrudedheat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessoriesincluding suitable polycarbonate rod at any height, internally prewired& including up with twin core twisted flexible copper cable of suitable size all as specified and as directed |
| 172 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose at any height complete all as specified and directed..Make : Havells Cat No LUMILINEPLUSNEOBS20WLED865SPCSS or equivalent in Philips/Crompton/Wipro |
| 173 | Supply & fix LED edge lit Luminaire suitable for recess mounting2\"x2\", 36 Wattwith polycarbonate housing integrated electronic driver complete at any height with all accessories including internally prewired all as specified and as directed. Make : Havells Cat No PLANO2X2PLR36WLED865 or equivalent in Philips/Crompton/Wipro |
| 174 | S&F LED lights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size at any height complete all as specified and directed.Make :Havells LUMILINE+BS10WLED865SPCSS |
| 175 | S&F new generationenergy saving and enviromental freindly LEDstreet light25 watt made up ofpressure die cast aluminum housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK 07completeincluding 25/40mm suitable size GI pipe bracke with nut, bolts and washers etc at any height all as specified and as directed. Make :Havells cat no ENDURASUNDOWNS25LED765PASYBOPCIHD |
| 176 | S&F Rigidconduit welded of external dia 20 mm dia includingjunction box with cover and outlets |
| 177 | Earthing complete with galvanised steel earth plate electrode 60 × 60cm.× 6mm thick, burieddirectly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all including charcoal/ coke and salt as specified or indicated including testing on completion |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy