Tender For Special Repairs And Additional / Alternator To Bldg Or Md Accommodation Of Zone E At Mil Stn Agartala, agartala-Tripura

Military Engineer Services-MES has published Tender For Special Repairs And Additional / Alternator To Bldg Or Md Accommodation Of Zone E At Mil Stn Agartala. Submission Date for this Tender is 03-06-2023. Building Work Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

37759279
Tender For Special Repairs And Additional / Alternator To Bldg Or Md Accommodation Of Zone E At Mil Stn Agartala
Open Tender
Indian
Tripura
agartala
03-06-2023

Tender Details

Special Repairs And Additional / Alternator To Bldg Or Md Accommodation Of Zone E At Mil Stn Agartala

Key Value

Document Fees
INR 1000 /-
EMD
INR 122500.0 /-
Tender Value
INR 65 Lakhs /-

BOQ Items

NAME OF WORK:SPL REPAIRS AND ADDN/ALTN TO OR MD ACCN OF ZONE "E" AT MIL STN AGARTALA.
Sl. No. Item Description
1Material and labour for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. Note: Cutting of grooves will be carried out by using mechanical means like Groove cutter/ wall chaser.
2Material and labour for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 15mm thickin cement mortar 1:4 on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, applying one coat of cold bitumenous primer @ 0.25 lits per sqm conforming to IS 3384-1986, and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.50 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied overBitumenious primer (Application of polymerie memberane shall be by torch application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinaldirection) coved fillet in PCC (1:2:4) type B-0 of radius 75 mmshall be provided at the junction of roof & other vertical surfaces& surfaces shall be painted with hot paving bitumen of penetrationvalue 30/40 conforming to IS 73 @ 1.20 kg/sqm over a coat of bitumenous primer @ 0.30 ltrs per sqm & applying one coat of aluminium paint over the APP nmodified membrane @ 0.11 kg/sqm including taking down existing Roof Treatment of any descriptionand removing rubbish to a distance not exceeding 50m complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
3Dismantling of AC sheet corrugated / CGI corrugated sheets in roofing any gauge and any thickness including ridge, valley/gutter etc.
4Supply and fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified complete all as specified and as directed.
5Supply and fixing pre-painted galvalume aluminium zinc coating GI based plain steel sheet0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified complete all as specified and as directed.
6Material and labour for preparation of old steel surfaces over 10cm width or girth and applying one coats of syntheticenamel paint complete all as specified and directed.
7Dismantlingfloor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceabletiles to store and rubbish off the premises complete all as specified and as directed.
8Roughening surfaces of old concrete floor by picking, sweeping clean & washing down with water to remove dust etc and brushing neat cement slurry at the rate of 3 kg per sqm complete all as specified and as directed.
9Material and labour non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38 sqm in floors etc.set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
10Material and labour non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38 sqm on skiriting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over backing coat of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
11Material and labour non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc.set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
12Material & Labour glazed ceramic coloured tiles 450X 300X 7mm thick of premium quality on skiriting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over backing coat of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
13M & L for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
14Material & Labourmachine cut kota stone slab as in riser of steps, skirting, dado etc. using 20 to 25mm thick slabs laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including borders, margins in two or more shades of slabsover backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
15Material and labour 25mm thick forPCC 1:2:4 typeB-0, using 12.5 mm graded stone aggregate as infloor finished even and fair without using extra cement complete all as specified and directed.
16Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
17Material & Labour for providing 100 mm thick plain cement concrete 1:3:6 type C-2, using (40 mm graded brick aggregate) as in path or pavementfinished even and fair without using extra cement complete all as specified and directed.
18Material and labour for precast cement concrete chequered tiles of size 300 x 300 x 22 to 25 mm thick as in floor, set and jointed and pointed with neat cement slurry laid over and including 20 mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
19Material & Labour for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth without using extra cement and providing necessary joints 12mm wide to the full depth of PCC at every 3 meters and every change of directions and the joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
20Material and labour for PCC 1:3:6, Type C-1 [using 20 mm graded granite stone aggregate] in surface channels and drains including forming fair finished drain or channel of any inner girth using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
21Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.completeall as specified and as directed.
22Add or deduct for each 25 mm girth or part there of over or under 30cm from item No. 23 above. (For adjustment only)
23Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)and removal of rubbish from the site complete all as specified and as directed.
24M&L for RCC (nominal mix) 1:1.5:3 type A1 (Using 20 mm graded stone aggregate) as in slabs supported on wall / beams / columns in floors / roofs/ shelves and the likecomplete all as specified and as directed.(Note: Formwork and reinforcing bar shall be measured and paid separately in relevant items.)
25Material and labour for use and waste of form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar work, etc. not exceeding 200mm thick with rough finished surfaces of concrete flat complete all as specified and as directed.
26Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
27Material and labour for Cutting holes in brick walls built in cement mortar lime mortar & stone walls built in lime mortar incement mortar 1:3 or cement concrete 1:2:4 type B-1 as required superficial area not exc 150 Sq CM complete all as specified and directed.Note: Cutting of holes will be carried out by using mechanical means like Groove cutter/ wall chaser.
28Supply and fixing for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, window cills, cooking platforms and like etc and fixed over and including 15mm thick cement plasterin cement mortar (1:4) and pointing with white cement mixed with pigment to match the shade of granite (1:2)complete all as specified and as directed.
29Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed.
30Material and labour forbrick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
31Material and labour Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls, built incm 1:4 complete all as specified and directed.
32Taking down cement plaster on brick concrete surfaces including racking out joints hacking for key, scrubbing down with, water etc complete all as specified and directed.
33Material and labour for 15mm thick rendering in CM (1:4) on concrete surfaces mixed with integral water proofing compound @ 200ml per bag of cement/ as per manufacturer"s instructions and finish the surface even and fair complete all as specified and directed. (Note:Water proofing compound shall be measured & paid separately)
34Materials and labour for 10 mm thick rendering on other than fair faces of brick work or concrete surfacein cement mortar (1:6) andfinish the surface even and smooth without using extra cementcomplete all as specified and as directed.
35Material and labour for 5 mm thick rendering in CM (1:3) on fair face of concrete surfaces as in ceiling etc finished the surface even and smooth without using extra cement complete all as specified and directed.
36Material and labour for preparation of newly plastered wall / Ceiling surfaces and applying Two coats of Weather ProofPaint over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed.
37Material and labour for complete removal of existing treatment on wall surfaces and applying Two coats of Weather Proof Paint over a Coat of Exterior Primer of same manufacturer as that of paint over 1 mm thick Cement based Wall Care Putty including necessary preparation of surfaces complete all as specified and as directed.
38Material and labour for preparing newly plastered Wallsurfacesandapplying two coats of Oil Bound Distemper over a coat ofprimer over 2 mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed.
39Material and labour for Complete removal of existing treatment of any description on wallsurfaces and applying 3mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Oil Bound Distemper over one of primer on wallsurfaces complete all as specified and as directed.
40Material and labour for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
41Material and labour for preparation of old decorated plastered ceiling surfaces and applying one coat of white wash complete all as specified and directed.
42Material and labour for Writing letters or figures [Block, Roman, Italic or Indian] not exceeding 30 cm high with thick paint to stand out boldly and solidly without showing signs of brush marks complete all as specified and as directed.
43Supply only liquid water proofing compound complete all as specified and directed.
44Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
45Material and labour for preparation of new unplastered surfaces over ceiling and applyingtwo coats of oil bound distemper over a coat of primer on board complete all as specified and directed.
46Material and labour for 4mm thick asbestos cement plain building boards, fixed timber framework with screws complete all as specified and as directed.
47Supply and fixing Rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W (Gde-E- 250) quality- A etc complete all as specified and as directed .
48Material and labour for preparation of new steel surface over 10cm width or girth and applying two coats of syntheticenamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
49Taking down chowkat with shutter without taking off shutter from the frame exc 1.50 Sqm but n.exc 4.00 Sqm each complete all as specified and as directed.
50Supply and fixing 125x60mm size pressed steel, frames for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate, etc, complete all as specified and as directed.
51Supply and fixing 105x60mm size pressed steel, frames for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate, etc, complete all as specified and as directed.
52Material and labour Plain cement concrete in bed block and filling of door frame type C-1 1:3:6 (20 mm graded stone aggregate) complete all as specified .
53Supply and fixing for 30mm thick factory made flush door shutters solid core construction with block board core and ply wood face panels commercial type on both faces complete all as specified and as directed.
54Supply and fixing Factory made, 35mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [b] and fitted to Chowkats complete all as specified and as directed.
55Supply and fixing Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
56Cutting holes into brick wall for inserting hold fast & making good dismantled portion in cm (1:3) or PCC (1:2:4) type B1, depth of cutting exe half brick but not exe one brick complete all as specified and as directed. Note: Cutting of holes will be carried out by using mechanical means like Groove cutter/ wall chaser.
57Material and labour mild steel work as in holdfast and similar works conforming to Fe290 GDE E-165 complete all as specified and as directed.
58Supply and fixing 25 mm thick exterior grade prelaminated particle board (prelaminated on one side) with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work for cupboard shutters complete all as specified.
59Supply and fixing18/19 mm thick exterior grade prelaminated particle board (prelaminated on one side) with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work for Cupboard partition complete all as specified.
60Extra over rates for block board or veneered particle board for external teak wood lipping complete all as specified and directed.
61Material and labour well seasoned 2nd class hard wood plain fillets, square, rectangular in section, clean sawn secured with nails or brads, sectional area exc. 13 but not exc. 25 Sqcm complete all as specified and as directed.
62Taking down chowkat with shutter without taking off shutter from the frame n.exc 1.50 Sqm each complete all as specified and as directed.
63Supply and fixing Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
64Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with Particle Board Core, 28 to 30mm thick [Stiles], with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm plain colour PVC sheet on back face, termite proof, water proof and fire resistant, supplying & fixing in frame at site as per specification & drawing shown on Serial Page No. 181 of MES Schedule Part - II complete all as specified and as directed.
65Supply and fixing continious (Piano) hinges, mild steel, bright finish or electro galvanised of 30mm width (when open) complete all as specified and as directed.
66Supply and fixing Mild Steel Door Spring 300 mm, Ordinary Rat Rail Rod Pattern springs including roller and roller plate complete all as specified and as directed.
67Supply and fixing 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
68Supply and fixing 125mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
69Supply and fixing 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
70Supply and fixing 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
71Supply and fixing 100mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
72Supply and fixing mild steel sliding door bolts of size 250mm length of bolt, plate type, stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate & two on staple plate complete all as specified and directed.
73Supply and fixing 40mm dia copboard knobs fixed with nut, screw and washer of brass polished. complete all as specified and as directed
74Supply and fixing Hasp and Staple, safety type of aluminium anodised including bolt to hinge plate, fixed with screws of 100mm size complete all as specified and as directed.
75Supply and fixing in repairs 100 mm size, Butt hinges, Extruded Aluminium alloy with galvanised mild steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed.
76Supply and fixing in repairs 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
77Supply and fixing in repairs 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
78Dismantling timber boarding of any description fixed in any position complete all as specified and directed.
79Supply and fixing 2nd class Hard wood 20 mm thick boarding planed both side with butt joints fixed with nails in any situation complete all as specified and as directed
80Material and labour forpreparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and as directed.
81Material and labour for preparation of old decorated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
82Supply and fixing in repairs 25 mm dia Harrison Rails [Curtain Rails], mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
83S & F Aluminium Powder Coated Three Track (2 glazed & one gauze shutter) Sliding Window Frame (aluminium sections weighing not less than 1.67kg/m for frame) and Shutters (aluminium sections weighing not less than 0.55kg/m for shutter) including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [4 Nos], including glazing with 5.5 mm thick Tinted Glass and aluminium Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium beading and making good the surface complete all as specified . Note: (a)The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as locks, 5.5mm thick tinted glass and wire cloth etc.
84Supply and fixing Powder coated aluminium louvered ventilators of size 600X600mm with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazingcleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangementsand making good the surface complete all as specified . Note: (a)The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as locks, 5.5mm thick tinted glass etc.
85Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
86Supply and fixing mild steel work such as grills,gratings,guard bars etc and similar work conforming to Fe290 GDE E-165 complete all as specified and as directed.
87Material and labour for preparation of steel surface n.exc 10cm width or girth and applying two coats of syntheticenamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
88Demolition of Unreinforced Cement Concrete/ Lime concrete of sunken floor (ground or 1st) and removing rubbish to a distance exceeding 150M but not exceeding 250 M complete all as specified and as directed.
89Material and labour forPCC 1:5:10 type E2, using 40 mm graded stone aggregate as in sunken floor complete all as specified and directed.
90Material and labour for 20 mm thick cement plaster in CM 1:4 mixed with Water proofing Compound@ 200ml per bag of cement/ as per manufacturer"s instructions on sunken portion with acrylic based polymer modified cementitious composite compound as approved by GE/AGE(I) and applying cement slurry two layers i.e. 1st layer @ 0.488Kg/ Sqm mixed with composite compound @ 0.253 Kg/Sqm & 2nd layer @ 0.242Kg/ Sqm mixed with composite compound @ 0.126 Kg/Sqm and applying 200 micron polyfilm with adhesive complete all as specified and directed. Note: Minimum 4 hours gap for air curing will be maintained between 1st layer and 2nd layer.
91Supply and fixing in repairs Vitreous China squatting pan of‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding andconnection to trap, flushing pipe, antisyphonage pipe, etc. including making good the disturbed floor complete all as specified and as directed.
92Supply and fixing in repairs 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed by Engineer-in-Charge.
93Supply and fixing in repairs vitreous china WHB of size 450x300mm including waste fittings, brass, chromium plated with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed etc complete all as specified and directed.
94Supply and fixing in repair low density polythene (LDPE) pins of pressure rating 6 Kg/Sq cm bore of tube 32 mm for waste pipe of WHB or sinks etc complete all as specified directed.
95Supply and fix in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
96Supply and fix in repair pillar taps 15mm dia bore fancy typewith capstain heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified directed.
97Supply and fixing in repairs looking mirror ofsize 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and as directed.
98Supply and fixing in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long completeall as specified and as directed.
99Supply and fixing in repairs 15mm bore stop valve fancy type,chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
100Supply and fixing in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
101Supply and fixing in repairs 15mm bore fancy type chromium plated bib taps with crutch of butterfly handle screwed down for iron pipes complete all as specified and directed.
102Supply and fixing in repairs of size 125 mm brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe or union complete all as specified
103Supply and fixing in repairs 15mm bore brass chromium plated mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all specified and directed.
104Supply and fixing in repairs Soap dish, vitreous China white of approximate size 160 x 160 x 90 mm complete all as specified and as directed.
105Supply and fixing in repair 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified .
106Supply and fixing 50mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or innfloors etc complete all as specified .
107Taking up or down 20mm bore steel water tubing & connections complete all as specified and as directed.
108Taking up or down 15mm bore steel water tubing & connections complete all as specified and as directed.
109Fixing only galvanized steel tubing medium grade, 20mm bore with all fittings and fixed complete to walls and ceiling or laid in floor all as specified and as directed.
110Fixing onlygalvanized steel tubing medium grade, 15mm bore with all fittings and fixed complete to walls and ceiling or laid in floor all as specified and as directed.
111Supply and fixing 15 mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed.
112Supply and fixing 20 mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed.
113Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick wall complete all as specified and as directed. Note: Cutting of holes will be carried out by using mechanical means like Groove cutter/ wall chaser.
114Supply and fixing in repairs stainless steel (conforming to AISI-304 grade) plate rack of overall size 780mm x 900mm x 250mm made of 1mm thick stainless steel sheetfixed on CP cantilever brackets complete all as specified and as directed.
115Supply and fixing as in replacement stainless steel (conforming to AISI-304 grade) kitchen sink with drain board of overall size 915mm x 460mm and bowl size 410mm x 310mmx 160mm depth or equivalent made of 1mm thick stainless steel sheet with 32mm bore CP waste coupling, 32mm bore PVC waste pipe(heavy duty) 90 cm long,and bedded in cement mortar and fixed on CP cantilever brackets complete all as specified and as directed.
116Dismantling water tank of capacity exc. 250 litre but n.exc. 500 litre and removing from site complete all as specified and as direcetd.
117Supply and fixing500 ltrs capacity rotationalmoulded polythene three layer water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position complete all as specified directed.
118Supply and fixing 20 mm bore ball brass valve high pressure with polythene float & fly nut compelete screwed for iron pipe or brass ferrule complete all as specified directed.
119Supply & fixing in repairs gun metal gate valve 20mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
120Taking down PVC soil pipe with fittings from wall, treches of any description including fittings complete all as specified.
121Supply and fixing 75 mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring loints, fixed to walls complete all as specified and directed.
122Supply and fixing 110 mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring loints, fixed to walls complete all as specified and directed.
123Supply and fixing 75 mm bore PVC (SWR) bends in any types complete all as specified and directed.
124Supply and fixing 110 mm bore PVC (SWR) bends in any types complete all as specified and directed.
125Supply and fixing 75 mm bore PVC (SWR) bends in any types with acess door complete all as specified and directed.
126Supply and fixing 110 mm bore PVC (SWR) bends in any types with acess door complete all as specified and directed.
127Supply and fixing 110 mm bore PVC [SWR] Branch Piece, Single [Single "Y"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
128Supply and fixing 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
129Demolition and breaking up 100 mm dia internal dia bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
130Material and labour for 100mm thick concrete bed to drain pipe (100 mm bore) with PCC (1:4:8) type D2 using 40mm graded stone aggregate including packing under and haunching aginnst the sides of pipe after they are laid jointed and tested complete all as specified .
131Material and labour Salt- Glazed stoneware drain pipes 100mm borelaid in trenches and jointed complete all as specified .
132Material and labour for salt-glazed stoneware gully traps, square or round mouthed, type `P" 150x100mm complete all as specified.
133Material and labour for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
134Material and labour for Treatment of soil under existing floors using emulsion @ 01 litre / hole, 300mm apart including drilling minimum 300mm deep & plugging 12mm dia holes with CM(1:2) to match the existing floors complete all as specified and as directed.
135Taking down carefullyexisting copper/Aluminum point wiring (light,socket or power) complete includingfittings such as switches, ceiling roses, pendents, sockets, boxes, light fitting etc and removing from site and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
136Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessoriesand PVC rectangular boxes for mounting switch,bell push, socket and fan regulator etc complete all as specified and as directed. Note: (i) Wiring shall be done in proper colour coding using red , yellow, blue for phase, black for neutral and green for earth. (ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.
137.-Ditto- all as per item No 136.00 here-in-before butfor 3/5 pin 6 amps socket outlet on the same board with other switches .
138.-Ditto- all as per item No 136.00 here-in-before butfor 3/5 pin 6 amps socket outlet on the independant board .
139.-Ditto- all as per item No 136.00 here-in-before butfor 3/5 pin 6 amps socket outlet on the independant but below the switch board of light point in the same vertical plane wall.
140.-Ditto- all as per item No 136.00 here-in-before butfor one 3 pin 16 Amps socket outlet on independent boardwith 2.5 sqmmPVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor.
141Supply and fixing switch socketcombination multi purpose2 in 1, 5 pin, 5 and 15 Amps, 230 volt flush type complete all as specified and as directed.
142S & F Buzzer, Ding dong AC, 230 Volts, Single Pole complete all as specified and as directed.
143Supply and fixing piano bell push6 Amps, 230 volt flush type complete all as specified and as directed.
144Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
145Material and labour for switch socket combination 5 pin,6 amps flush type ISI marked complete all as specified & directed.
146Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
147Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 62.5mm x 50mm,ISI marked three terminals complete all as specified & directed.
148Supply and fixing electronic fan regulator (step rotary type), AC 240 voltcomplete all as specified and as directed.
149Supply and fixing MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including taking down of existing unserviceable DB with MCBs including making good disturbed surfaces complete all as specified and as directed.
150Supply and fixing MCB, single pole "B" series having braking capacity 10 KA, 6 to 32 Amp, 240 volts,complete all as specified & directed.
151Supply andfix MCB TPN 40 Amps, 415 volts, 10 KA, "B" series with all incoming / outgoing connections suitableforDB in double doorwith proper size of aluminium lugs completeall as specified as directed .
152S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door suitable with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including taking down of existing unserviceable DB with MCBs including making good disturbed surfaces complete all as specified and as directed.
153Supply and fixing MCB ,SPN, 6 to 32 amps, 240 volts, 10 KA, "B" series with all incoming / outgoing connections suitableforDB in double door with proper size of aluminium lugs completeall as specified as directed . Note for serial Item No. 149 to 153: MCB and MCB DB shall be of same make as approved by AGE (I).
154Supply and fixing in repairs LED street light fitting 35 Watt 230 V AC with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver, including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
155Material & Labour for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfaces complete all as specified as directed. Note : (i) 3 Runs of 2.5 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.
156Material & Labour for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfaces complete all as specified as directed. Note : (i) 3 Runs of 2.5 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.
157Supply and fixing in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of 20 W, 6500 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
158Supply and fixing in repairs Surface & wall mounted Energy efficientLED Mirror Tube Light Fitting, of 10 W, 6500 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
159Supply and fixing in repair Integrated LED Bulk head with luminaire of 10W, 6000 K with Pressure Die Cast Aluminium Housing, IP54 protection, heat resistant glass cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
160Supply and fixing in repair 7 Watt LED lamp (B22 Base type) complete all as specified and as directed.
161Taking down ceiling fan carefully of any size from its original position, kept in safe custody and refixing the fan in same position or at new place including cleaning complete all as specified and directed.
162Taking down KWH meter of any description, from its original position, kept in safe custody and refixing in thesame position or at new place including cleaning complete all as specified and directed.
163Taking down & refixing water heater with two nos connector of suitable dia of pipes and suitable size nut bolts for proper fixingcomplete all as specified and directed.
164Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
165Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Disclaimer :