Tender For Comprehensive Maintenance Of Fire Alarm Panel Detector And Allied Works And Repair And Maintenance Of Lt Distribution System With Allied Works In Camp I, Camp Ii And Sv Area At Kalaikunda Under Ge (Af) Kalaikunda, kalaikunda-West Bengal

Military Engineer Services-MES has published Tender For Comprehensive Maintenance Of Fire Alarm Panel Detector And Allied Works And Repair And Maintenance Of Lt Distribution System With Allied Works In Camp I, Camp Ii And Sv Area At Kalaikunda Under Ge (Af) Kalaikunda. Submission Date for this Tender is 27-06-2023. Fire Alarm Systems Tenders in kalaikunda West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37731289
Corrigendum : Tender For Comprehensive Maintenance Of Fire Alarm Panel Detector And Allied Works And Repair And Maintenance Of Lt Distribution System With Allied Works In Camp I, Camp Ii And Sv Area At Kalaikunda Under Ge (Af) Kalaikunda
Open Tender
Indian
West Bengal
kalaikunda
27-06-2023

Tender Details

Comprehensive Maintenance Of Fire Alarm Panel Detector And Allied Works And Repair And Maintenance Of Lt Distribution System With Allied Works In Camp I, Camp Ii And Sv Area At Kalaikunda Under Ge (Af) Kalaikunda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2023 AMENDMENT IN TENDER DOCUMENTS Financial Bid 08-06-2023
2 27-May-2023 REVISED BOQ BOQ 08-06-2023
3 31-May-2023 date extension corrigendum Date 15-06-2023
4 02-Jun-2023 REVISED BOQ,. BOQ 15-06-2023
5 15-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-06-2023
6 22-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVEMAINTENANCEOF FIRE ALARM PANEL DETECTOR AND ALLIED WORKS AND REPAIR AND MAINTENANCE OF LT DISTRIBUTION SYSTEM WITH ALLIED WORKSIN CAMP-I, CAMP-II AND SV AREA AT KALAIKUNDA UNDER GE (AF) KALAIKUNDA
Sl. No. Item Description
1Comprenesive maintenance and repair including renewal/replacement and installation of defective parts of all existing fire detection system complete consisting of addressable fire control panel 19 Nos., Conventional Fire Alarm Panel 11 Nos., Remote Terminal Unit panels 20 Nos., smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier 20 Nos, Loud speaker, Loop isolator, Zone monitor module, Modem etc. located in technical and domestic area ,to make them 100 % serviceable incl checking of fire detector, checking the batteries and its connections, alarm system and itsfunctions, functionallity of fire controlpanel and indicating eqpt all to be checked by the operation of trigger device in each zone as described. The system installed in Fire station and at other locationsto be inspected and checked for its functionality and to make functional in all respect and if any defect observed to rectify it by visiting every monththrough Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directedNote:- (i) Cost of new components shall be paid separately under relevant items. (ii) Contractor"s rep shall visit every month to check all fire panel and systemto check its functionility and to make them functional. if any defect observed. (iii) He shall take the serviceability certificate duly signed by the user and submit to the department. After obtaining / producing seviceability certificate of system payment will be made to contractor .(ii) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal runningincludes maintenance of all mechanical, electrical and electronic parts /sub-assemblies. Thepreventive maintenance report will be as per the Original Equipmentanufacturer"s instructions and Specification. The Contractor may claim payment on monthly basis.(iii) Breakdown Maintenance : The Authorised ServiceEngineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF kalaikunda)officials or their representatives, The OEM"s authorised service representative or OEM certified agencieswill carry out the required repairs of theunits and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period (iv)Each maintenance job shall be covered period of 01 Months. (v) All minor spares required for making the pump functional shall be provided by contractor without any extra cost
2(a) Station Fire section
3(b) WSA
4(c) Ration store
5(d) MT FSS
6(e) Logistics & Immols
7(f)ATC Building
8(g) Base Ops
9(h) Hawk Tech Flt (Hawk Tech Hanger)
10(j) Hawk Tech Flt FSS R1, R2, R3 (Hawk Tech Hanger)
11(k) OCU "B"
12(l) OCU "A"
13(m) MT POL Store AF
14(n) Logistics Aerolube Store
15(o) CEO Complex
16(p) BCR Buliding
17(q) GPU & Logs POL (MT Section)
18(r) HST & Compressor (MT Section)
19(s) CCR
20(t) 17 END ABH (17 ORP Hut)
21(u) 35 END ABH (35 ORP Hut)
22(v) HQ Signal Section
23(w) 771 SU Panel No.1
24(x) 771 SU Panel No.2
25(y) IT Cell Panel No.1
26(z) IT CellPanel No.2
27(aa) PAR Building
28(ab) MES MT POL store
29(ac) Main power House
30(ad) MES DG POL store
31(ae) 33 MRS
32(ae) Hawk simulator
33(ae) DWR sites
34Servicing of allmultisensor detector with heat and smoke combination photoelectric after taking down from its position and refixing after servicing as per OEM instructionsthrough Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE , checking and testing its functionality,tracing and clearing any fault observed including cleaning detectors through air blower on site complete all as specified and directed. Note : Cleaning of detector to be done in every three months.
35Testing offlamedectorsdevice, checking its functionality, rectifying any defects observed and testing themwithUVandIRdetectionat sitein hangers complete all as specified in OEM instructionsthrough Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE and directed by EIC. Note : Testing to be done in every six month. Make : CIMCON or equivalent make
36Supply and fixingof GSM SIM card with validity ofSMS packs for 12 monthssuitable forexistingalarm control panelsto pass the signals from fire alarm panels located in different sectionsto Main fire alarm panel located in Fire Brigade section through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE complete all as specified and directed by EIC. Note:- GSM service provider shall be choosen (as per network availability) by Engr-in-Charge.
37Supply only of 12 V, 100 AH batteryfor back up to all FACP and RTU panel as per OEM specification complete. Make: Exide/Amar Raja.
38Supply onlyof 12 V, 7 AH batteryfor back up to all FACP panel as per OEM specification complete. Make: Exide/Amar Raja.
39Supply only Indoor type detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric /optical with base with self built intelligence as per OEM specification complete all as specified and as directed.
40Supply onlyelectronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with following specifications as under:-Power- 24V, = 0.6 mA (Standby Current) =1.8mA (Alarm Current),Class A , Initiating Mode - Pressing the action plate manually,Resuming Mode-Manually Resumed by a special Key , Ingress ProtectionIP-43 & Material-ABS all as per IS : 2189 / 1988 as per OEM specification completeall as specified and as directed Make: GST/Morley/ Siemens/Bosch)
41Supply onlyintelligent loop isolator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, = 3 mA (Standby Current) =15mA (Action Current) b) Class A , c) Initiating Mode- Yellow flashes when polling, illuminates in action, d) Ingress ProtectionIP-30 & Material-ABS or as per OEM specification complete.Make: Make: GST/Morley/ Siemens/Bosch) or equivalent make
42Supply only the announcing device Remote response indicator as per OEM specification complete all as specified and directed.Make: GST/Morley/ Siemens/Bosch)
43Supply only fire alarm sounder/sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range as per OEM specification complete and directed. Make: GST/Morley/ Siemens/Bosch)
44Supply only Wireless modem suitable for GSM based communication system to be mounted in RTU enclosure shall be installed at all proposed buildings as per OEM specification all as specified and directed.Make: GST/Morley/ Siemens/Bosch)
45Supply onlyAmplifierssuitable 30-60Watts, 230VAC50Hzas per OEM specification completeallasspecifiedanddirected. Make: Ahuja.
46Supply onlyindoordetectorcomplyingwithandtypecertifiedtoEN -54AddressabletypeflamedectorswithUvandIRdetectioncapacity(addupcostofmoduleto beacompleteset,thetypeofmoduleshallberelaytypemodule)withselfbuiltintelligenceasperIS: 11360 as per OEM specification complete allasspecifiedanddirected. MAKE-AGNI or equivalent make
47Supply only Input Module for Fault and Alarm Monitoring, 24VDC required (Zone Monitor Module) as per OEM specification complete.Make: GST/Morley/ Siemens/Bosch)
48Supply only wall mounted horn type loudspeaker 15 watt 230V AC ,50Hz of sturdy design weather proof type re-entrant horn type loudspeaker for operating under rough conditions as per OEM specification complete.Make:- Ahuja/Morley/ Siemens/Bosch)
49Supply only 24 V DC Power Supply Unit of iRTU,as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
50Supply only 12/5 V DC Power Supply Unit of iRTU, as per OEM specification completeMake : CIMCON//Morley/ Siemens/Bosch
51Supply onlyARM7 based CPU card with 3 nos. serial Port, 1 ethernet Port and SD card slot of RTU as per OEM specification completeMake : CIMCON//Morley/ Siemens/Bosch
52Supply onlyAnalog and Digital I/O Card of RTU, as per OEM specification completeMake : CIMCON//Morley/ Siemens/Bosch
53Supply onlyDI/AI Termination PCB of RTU,as per OEM specification completeMake : CIMCON//Morley/ Siemens/Bosch
54Supply only Display and Keyboard of RTU,as per OEM specification completeMake : CIMCON//Morley/ Siemens/Bosch
55Supply only DO Termination PCB of RTU, as per OEM specification completeMake : CIMCON//Morley/ Siemens/Bosch
56Supply onlyMCB 6A SP, C curve , 10 KA as per OEM specification completeMake : / Siemens/Bosch/L&T
57Supply onlyLEDs (Red/Green) for RTU Panel.as per OEM specification completeMake : Safetek or equivalent make
58Supply onlyRelay card : 8 relay 1 c/o for RTU panel as per OEM specification complete Make :Connectwell/Brisk/Elmex.
59Supply only Isolation transformer-300 VA for RTU panel as per OEM specification complete Make :Safetek or equivalent make
60Supply only Push Button withNO/NC contact (BLACK) as per OEM specification complete Make: ESBEE or equivalent make
61Supply only GST200-2 Main Board F2.908.826a for FACP as per OEM specification complete Make: GST or equivalent make
62Supply onlyLCD Screen CGM12864 for FACPas per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
63Supply only GST200 Rubber Keypad F7.843.249for FACPas per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
64Supply onlyGST200 Loop Interface Board F2.908.828 (RoHS)for FACP as per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
65Supply onlyGST200 Power Supply Unit F2.932.069 (20100682)for FACPas per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
66Supply onlyTransformer 220V/27V-100W-R for FACPas per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
67Supply only Sine Wave Inverter Capacity : 850 VAUPS as per OEM specification completeMake: Luminous.
68Supply only copper conductor of size 1.5sqmm X 2 run FRLS flexible wire complete all as specified and directed.
69Supply only Optical conventional smoke detector 300 series,LPCB as per OEM specification complete Make:-Agni / System Sensor / GST.
70Supply only RoR conventional Thermal detector 300 series,LPCB as per OEM specification complete Make:-Agni / System Sensor / GST.
71Supply only two wire Plug in detector base series 300 LPCB as per OEM specification complete Make:-Agni / System Sensor / GST.
72Supply only conventional MCP ,Red colour with LED 470 ohms, with back box andsurface mouting box red colour as per OEM specification complete Make:-Agni / System Sensor / GST.
73Supply only conventional Horn cum trobe, wall mounted,red colour as per OEM specification complete, Make :- Honywell / Agni .
74Supply only conventional Remote response indicator ABS body with dual LEDas per OEM specification complete Make :- Honywell / Agni .
75Supply only step down transformer for convention fire alarm panel as per OEM specification complete of make Agni or equivalent make
76Supply only two zoneInterface card for fire panel of as per OEM specification complete make Agni or equivalent make
77Supply only Display card for fire panel of as per OEM specification completemake Agni or equivalent make
78Supply only Main Board (CPU) for fire panel as per OEM specification complete of make Agni or equivalent make
79Supply only Transistor with heat sinkfor fire panel as per OEM specification complete of make Agni or equivalent make
80Supply only 2 Zone conventional Fire Alarm Panel as per OEM specification complete Make: Agni/GST/Honeywell.
81Supply only GSM Auto dialer as per OEM specification complete Make: SECSDE.
82Supply only Addressable Fire alarm Control Panel with 2 Loop as per OEM specification complete Make: GST.
83Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final.
84Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
85Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting pointall as specified and directed.
86M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed. (Note: For payment purposes only punned down thickness of sand shall be measured )
87M & L for laying old size sub class ‘B’brick for PVC/ XLPE underground cable protection in trench,layedin the manner that width of brick to be peperndicular to the axis of cable ,over LT under ground cable
88Laying onlybricks for PVC/ XLPE underground cable protection in trench,layedin the manner that width of brick to be peperndicular to the axis of cable ,over LT under ground cable (retreived from taking out of old unsv cable) all as specified and directed.
89Repairs / Maint of LT Panel board/ feeder pillar box of various sizes including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,replacingburnt DMC insulator or bus bar supports as per exsiting one, removing old burn out wiringand re-wiring with new cable of exsiting size, includingreplacement of un-serviceable parts and hard ware,replacement of all rusted nut bolts with new steel nut bolts and washer, wrapping of existing incoming and out going cables whose PVC insulation gets detoriated,cableto bewraped with insulation tape (minimum three layers over one another on detoriated portion) with colour code (Red, yellow blue for phase and black for neutral) complete all as specified & directed. Note :- (i) Cost of unsheathed multistranded copper conductor for internal wiring like connection of CTsand DMC insulators are deemed to be included in quoted rate. (ii) Suitable size of cable lugs to be provided by contractor for fixing /jointing the cable in bus bar etc. (iii) Cable gland if required shall be provided and included in cost of repair. (iv) Existing cable to be removed from MCCB/MCB and to be refixed after providing suitable size lugs. Cost of lugs included in cost of repair.
90Supplyandfixing in repair 3 phasedigital voltmeter flush mounting 96X96mm of input voltage measurement range 50-520 VAC(P-P) , 5A,accuracy class 1.0 forLT panel board,aux supply 80-300VAC,CT secondary site selectable 1A/5A,flush mounting 96x96 mm with inbuilt selector switchincluding taking down old u/s complete all as specified and directed by Engr-in-Charge Make : AE/Siemens/Hager/L&T
91Supplyandfixing in repair3 phasedigital Ammeter flush mounting 96 x 96 mm ,CT secondary site selectable 1A/5A,accuracy class 1forLT panel board, aux supply 80-300VAC,CT secondary site selectable 1A/5A,flush mounting 96x96 mm with inbuilt selector switch including taking down old u/s . complete all as specified and directed by Engr-in-Charge Make : L&T Cat Part no. WL131010OOOO or equivalent in AE/Siemens/Hager
92Supply and fixingin repair Indoor type insulated ring type low tension current transformers of ratio 200/5A accuracy class 1.0for LT panel board, complete all as specified and directed by Engr-in-Charge including taking down unserviceable .
93Supply and Fix in repairs,LED Indicator 16 mm with power consumption < 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC, colour Red/Green/ Yellow/Amber/Blue/White, complete all as specified and directed. [Cat No. SIL of Make “L&T” or equivalent Model of Make HPL/ AE]
94Supply and fixingFRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size25 Sqmm single core including copper lugs complete all as specified and as directed.
95Supply and fixingFRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size50 Sqmm single core including providing copper lugs complete all as specified and as directed.
96Preparation of the old decorated existing external and internal steel surface of feeder pillar boxes/LT panels of any description, any size and in any positionby thoroughly cleaning of dirt, fluxing material, other foreign matter and sand papering the surface to remove all scale and rust,wiped finally with mineral turpentine to remove oil, grease and including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of synthetic enameled paintover a coat of red oxide primer by using spray machine on old prepared surface and writing MES serial No with approved colour code complete all as specified and dircted by engr in charg Note(i) Painting to be done after carrying out all the welding work for replacement of hinges, door lock etc. (ii) Painting shall be done by spray gun. (Approximate minimum area : 40 sqm)
97Preparation of the old decorated existing external and internal steel surface of feeder pillar boxes/LT panels of any description, any size and in any positionby thoroughly cleaning of dirt, fluxing material, other foreign matter and sand papering the surface to remove all scale and rust,wiped finally with mineral turpentine to remove oil, grease and including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of synthetic enameled paintover a coat of red oxide primer by using spray machine on old prepared surface and writing MES serial No with approved colour code complete all as specified and as directed. complete all as specified and dircted by engr in charg Note(i) Painting to be done after carrying out all the welding work for replacement of hinges, door lock etc. (ii) Painting shall be done by spray gun. (Approximate minimum area : 30 sqm)
98M&L for taking shut down including repairing of LT Panels (Indoor type) by providing connectors, copper lugs, nuts, bolts, etc of suitable sizes for incoming and outgoing UG cables includingproper LT insulation tapes to cables which are deteriorated and cleaning the internal area of panel, cleaning the rusted parts by WD-40 and replacing the damaged spare parts like nuts, bolts , screws etc with new steel nut bolts washersincluding repairing of panel doors by welding broken hinges and repairing the door locksall as specified and directed by Engr-in-charge. Note : (i) LT panelin which repairing of internal wiring, not requiredand not coveredunder respective item here-in-before shall be measured under this item. (ii) Excavation required and cost of lugs is deem to be included in rate of the item. (iii) Contractor shall arrange the Welding machine on site for welding ofdetached Panel doors by providingMS hinges heavy duty and providing tower bolt for locking arrangement
99M&L for taking shut down including repairing of feeder pillars out door typeby providing connectors, copper lugs, nuts, bolts, etc of suitable sizes for incoming and outgoing UG cables includingproper LT insulation tapes to cables which are deteriorated and cleaning the internal area of panel, cleaning the rusted parts by WD-40 and replacing the damaged spare parts like nuts, bolts , screws etc with new one including repairing of panel doors by welding broken hinges, providing new hinges where old hinge rusted and repairing the door locks / providing new locking arrangementincluding taking out incoming and out going cable burried in undergound cutting and providing new aluminium lugs and reconnected to bus bar/ MCCB`s/MCB`s all as specified and directed by Engr-in-charge. Note :(i) Feeder Pillar boxin which repairing of internal wiring,welding of doors not requiredand not coveredunder respective item here-in-before above shall be measured under this item. (ii) Excavation required and cost of lugs is deem to be included in rate of the item. (iii) Contractor shall arrange the Welding machine on site for welding ofdetached Panel doors by providingMS hinges heavy duty and providing tower bolt for locking arrangement
100M&L for Maintenceand cleaning of surrounding area of sub stations, near LT panels, feeder pillars, transformer etc by cutting seasonal grass, bushes etc,including spreading of strong herbicides in order to stop the fast growth of grass/bushes around the feeder pillars and panels by employing skilled mazdoor including using own T&P as required to do the job and taking all precaution while men on working in sub station being dange zone all as specified and directed by Engr-in-charge. Note : As vegitation growth is very high in the Stn due to humid climate,area cleaning of installations can be repeated and to be done twice/thrice as per the requirement and directed by Eng in Charge.
101Demolition of concrete of any description and in any position not otherwise specificallycomplete all as specified and directed.
102Materials and Labour for plain cement concrete (1:3:6) Type C-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
103Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered anglesthroating, as directed including necessary from work complete all as specified and directed.
104Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In,complete all as specified and directed. [Cat No.HHS101DR of Make “Hager” or equivalent Model of Make Siemens/ Legrand / ABB.]
105Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 125 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In,complete all as specified and directed. [Cat No.HHS126DR of Make “Hager” or equivalent Model of Make Siemens/ Legrand / ABB.]
106Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In,complete all as specified and directed.[Cat No.HHS161DR of Make “Hager”/Schneider Model : Easy Pact CVSCat Part No.LV516343 or equivalent Model of Make Legrand / ABB.]
107Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 200 Amps and minimum 36 KA breaking capacityIcu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In, complete all as specified and directed. [Cat No. HNT201DR of Make “Hager/Schneider Model : Easy Pact CVSCat Part No.LV525342 or equivalent Model of Make Legrand / ABB.] :
108Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 250 Amps and 40 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In, complete all as specified and directed. [Cat No. HNT251DR of Make “Hager /Schneider Model : Easy Pact CVSCat Part No.LV525343 or equivalent Model of Make Legrand / ABB.] :
109Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 400 Amps and Minimum 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In, complete all as specified and directed. [Cat No. HNJ401DR of Make “Hager /Schneider Model : Easy Pact CVSCat Part No.LV540309 or equivalent Model of Make Legrand / ABB.] :
110Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 630 Amps and 40 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In, complete all as specified and directed. [Cat No. HNJ631DE of Make “L&T/Schneider Model : Easy Pact CVSCat Part No.LV563309 or equivalent Model of Make Legrand / ABB.] :
111Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured,3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc with and including disconnecting and taking out unserviceable, U/G cables,old serviceable bricks, GI pipes complete all as specified and as directed.
112All as per Item No 79.00here-in-before but size of cable 95 sqmm3½ core, complete all as specified and as directed.
113All as per Item No 79.00here-in-before but size of cable 70 sqmm3½ core, complete all as specified and as directed.
114All as per Item No 79.00here-in-before but size of cable 50 sqmm3½ core, complete all as specified and as directed.
115All as per Item No 79.00here-in-before but size of cable 35 sqmm 4 core, complete all as specified and as directed.
116All as per Item No 79.00here-in-before but size of cable 25 sqmm4 core, complete all as specified and as directed.
117All as per Item No 79.00 here-in-before but size of cable 16 sqmm4 core, complete all as specified and as directed.
118All as per Item No 79.00here-in-before but size of cable 10 sqmm4 core, complete all as specified and as directed.
119M&L for detecting of fault in 1100V (E) LT cable of any size , 3½core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced &cost of Jointing kit shall be measured & paid separately.
120S& F SS enclosure for MCCBof rating 250 Amp In-built neutral Link for TPN system l IK08 and IP30 Protection having Louvers for better heat dissipation Suitable to accommodate upto 185 sq. mm. 3 1/2 core Aluminum armoured cable incl taking down unsv one and fixing serviceable/ new MCCB in enclosure and connectiing existing IC/OG cable with proper dimension lugs all as specified and directed. Make L &T Cat Part No. CM91003OOOO or equivalent in Havells /Hager.Note :New MCCB shall be measured and paid seperately.
121S& F SS enclosure for MCCB 125 Amp In-built neutral Link for TPN system l IK08 and IP30 Protection having Louvers for better heat dissipation Suitable to accommodate upto 70 sq. mm. 3 1/2 core Aluminum armoured cable incl taking down unsv one and refixing serviceable/ new MCCB in enclosure and connectiing existing IC/OG cable by providing lugs of suitabledimension all as specified and directed. Make L &T Cat Part No. CM90996OOOO or equivalent in Havells /CG/Hager.Note :New MCCB shall be measured and paid seperately.
122Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 6 sq. mm to 16 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0123 of Make "Raychem" or equivalent Model of Make M-Seal/3M]
123Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 25 sq. mm to 50 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0130 of Make "Raychem" or equivalent Model of Make M-Seal/3M]
124Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 70 sq. mm to 150 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0137 of Make "Raychem" or equivalent Model of Make M-Seal/3M]
125Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 150 sq. mm to 185 sq. mm, complete all as specified and directed. Make "Raychem" or equivalent Model of Make M-Seal/3M]
126Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 240 sq. mm to 300 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0144 of Make "Raychem" or equivalent Model of Make M-Seal/3M]
127Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 40 to100 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed.
128Material and labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc,including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
129Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc,including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
130Material and labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc,including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
131S & F in repair rotary handle for operating MCCB direct ROM typecomplete all as specified and directed by Engr in Charge. make: L&T Cat No. CM98040OOOO or equivalent of make: Hager/Schneider/siemens
132S & F in repair rotary handle for operating MCCB direct Extended ROM typeincluding taking downcomplete all as specified and directed by Engr in Charge. make: L&T Cat No. CM98041OOOO or equivqlent of make: Hager/Schneider/siemens
133M&Lfor fabricating door offeeder pillar box ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet , with anticorrosive coating and finally epoxy polyester power coatingwith pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 by providing hinges complete all as specified and directed by Eng in Charge.