Northern Coalfields Limited-NCL has published Tender For Repair And Maintenance Of Indus-Trial Buildings And Water Supply Distribution System And Horticulture Works In Mines Area At Bina Project For Two Years. Submission Date for this Tender is 02-06-2023. Building Repair Tenders in sonebhadra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37699147
Tender For Repair And Maintenance Of Indus-Trial Buildings And Water Supply Distribution System And Horticulture Works In Mines Area At Bina Project For Two Years
Open Tender
Indian
Uttar Pradesh
sonebhadra
02-06-2023

Tender Details

Repair And Maintenance Of Indus-Trial Buildings And Water Supply Distribution System And Horticulture Works In Mines Area At Bina Project For Two Years

Key Value

Document Fees
Refer document
EMD
INR 161700.0 /-
Tender Value
INR 1.29 Crore /-

BOQ Items

NAME OF WORK:-Repair and maintenance of industrial buildings and water supply distribution system and horticulture works in mines areaat Bina projectfor two years
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
3Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil
4Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
5Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatlydressed. All kinds of soil
6Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size)
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
11Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns, etc. for mass concrete
12Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13Providing, hoisting and fixing up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size).
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars
15Brick work with non modular FALG bricks confirming to IS: 12894, class designation 7.5 foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
16Brick work with non modular FALG bricks confirming to IS: 12894, class designation 7.5 in insuperstructure above plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
17Half brick masonry with non modular FALG bricks of class designation 7.5 in superstructure above plinth level up to floor V level.:Cement mortar 1:4 (1 cement : 4 coarse sand)
18Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
19Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated hollock wood
20Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position : Kiln seasoned and chemically treated hollock wood
21Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.Kiln seasoned and chemically treated hollock wood30 mm thick shutters
22Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Kiln seasoned and chemically treated hollock wood
23Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
24Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood
25Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 12 mm thick
26Providing and fixing 4mm thick coir veneer board, ISI marked IS : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete.
27Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
28Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm
29Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 100x58x1.90 mm
30Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 50x37x1.50 mm
31Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm
32Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm
33Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 100x10 mm
34Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm
35Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :100 mm
36Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 115 mm
37Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
38Providing and fixing plywood 4 mm thick, one side decorative veneer conformingto IS: 1328 (type-1), for plain lining / cladding with necessary screws, includingpriming coat on unexposed surface with :Decorative veneer facings of approved manufacture
39Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
40Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece
41Supplying of bolts and nuts 20 mm dia 80 mm long
42Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
43Welding by gas or electric plant including transportation of plant at site etc. complete.
44Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
45Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
46Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
47Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m²
48Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J, or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : 1.60 mm thick with zinc coating not less than 350 gm/m²
49Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
50Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend
51Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dashastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, tob which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to all/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing withinting compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
52Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated "J" or "L" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc.2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.
5312 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
5412 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
55Neat cement punning
56Colour washing such as green, blue or buff to give an even shade :(one or more coats)
57Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of whiting
58Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
59Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
60Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
61Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :C Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
62Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:glass panes weighing 10kg/sqm
63White washing with lime to give an even shade : Old work (one or more coats)
64Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats)
65Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one or more coats)
66Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
67Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
68Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
69Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
70Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats
71Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
72Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore
73Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : Above 40 mm nominal bore
74Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
75Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Up to 150 mm diameter
76Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
77Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
78Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :upto 10 mm thick
79Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
80Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
81Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
82Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :Flat back wash basin of size 550x400 mm
83Providing and fixing white vitreous china water closet squatting pan (Indian type) : Long pattern W.C. pan of size 580 mm
84Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet : 250x125x25 mm
85Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
86Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
87Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
88Providing and fixing 100 mm sand cast Iron grating for gully trap.
89Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
90Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
91Providing and fixing soil, waste and vent pipes :100 mm dia Sand cast iron S&S pipe as per IS: 1729
92Providing and fixing soil, waste and vent pipes :75 mm diameter :Sand cast iron S&S pipe as per IS: 1729
93Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989
94Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
95Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
96Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15 mm dia nominal bore
97Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore
98Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore
99Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 32 mm dia nominal bore
100Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore
101Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore
102Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore
103Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore
104Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore
105Providing and fixing brass stop cock of approved quality :15 mm nominal bore
106Providing and fixing brass stop cock of approved quality :20 mm nominal bore
107Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
108Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore
109Providing and fixing gun metal non- return valve of approved quality (screwed end) :50 mm nominal boreHorizontal
110Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal boreHorizontal
111Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore
112Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 150 mm diameter pipe
113Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 200 mm diameter pipe
114Supplying pig lead at site of work.
115Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter Class I
116Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :150 mm diameter Class I
117Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):15 mm nominal bore
118Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):20 mm nominal bore
119Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):25 mm nominal bore
120Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):50 mm nominal bore
121Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 15 mm nominal bore
122Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal bore
123Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 25 mm nominal bore
124Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
125Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms
126Providing and fixing PTMT pillar cock of approved quality and colour . 15 mm nominal bore, 107 mm long, weighing not less than 110 gms
127Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
128Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
129Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 80 mm long, weighing not less than 46 gms
130Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
131Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length 20 mm nominal bore
132Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter
133Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or peasized gravel spread at 6 cubic diameter per square metre including preparation of surface but excluding grading complete with :Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322
134Labour charges forstructural steel work
135Labour charges for fixing C.G.I. sheet
136Labour charges for laying & fixing of G.I. pipe line complete 15mm dia internal
137Labour charges for laying & fixing of G.I. pipe line complete 20 mm dia internal
138Labour charges for laying & fixing of G.I. pipe line complete 25 mm dia internal
139Labour charges for laying & fixing of G.I. pipe line complete 40 mm dia external
140Labour charges for laying & fixing of G.I. pipe line complete 50 mm dia external
141Labour charges for laying & fixing of G.I. pipe line complete 80 mm dia external
142Labour charges for laying & fixing of G.I. pipe line complete 100 mm dia
143Repairing of sluice valve spindle by breezing, machining etc. all complete job including material and labours as per instruction of EIC 100 mm
144Repairing of sluice valve spindle by breezing, machining etc. all complete job including material and labours as per instruction of EIC150 mm dia
145Repairing of sluice valve including replacement of all material such as MS spindle with chucknut,rubber insertion/packing nut bolts after dismantling the valve and refitting the same in position as per instruction of EIC .200 mm dia
146Repairing of sluice valve including replacement of all material such as MS spindle with chucknut,rubber insertion/packing nut bolts after dismantling the valve and refitting the same in position as per instruction of EIC .50 mm dia
147Repairing of sluice valve including replacement of all material such as MS spindle with chucknut,rubber insertion/packing nut bolts after dismantling the valve and refitting the same in position as per instruction of EIC .80 mm dia
148Repairing of bib cock 15 mm dia
149Cleaning of roof top water tank,including draining out water,cleaning,disinfecting the tank by bleaching powder etc. and washing the tanks with fresh water, writing of cleaning date with paint on the outer face of the tank all complete with tools,tackles and consumables as per instruction of EIC.
150Operation of valve & pump and water supply in industrial area at different location as per direction of EIC.
151Providing& fixing of G.I. pipecomplete with G.I. fitting including trenching & refilling etc. complete (external work ) 100 mm dia nominal bore.
152Earth work in excavation in all kind of soil/silt all operationmechanically witth all lifts,complete as per instruction of EIC within a lead of 50 m.
153Providing and fixing M-seal of approved quality as and where required as per instruction of EIC.
154Supply of GI nipple:15mm
155Supply of GI nipple:20mm
156Supply of GI nipple:25mm
157Supply of GI nipple:40mm
158Supply of GI nipple:50mm
159Supply of G.I. socket:15mm
160Supply of G.I. socket:20mm
161Supply of G.I. socket:25mm
162Supply of G.I. socket:50mm
163Supply of G.I. elbow:15mm
164Supply of G.I. elbow:20mm
165Supply of G.I. elbow:25mm
166Supply of G.I. elbow:40mm
167Supply of G.I. elbow:50mm
168Supply of G.I. Tee : 15mm
169Supply of G.I. Tee : 20mm
170Supply of G.I. Tee : 50mm
171Supply of G.I. Plug : 15mm
172Supply of G.I. Plug : 20mm
173Supply of G.I. Plug : 25mm
174Supply of G.I. Plug : 40mm
175Supply of PVC water tank cover
176Supply of bib cock/pillar cock washer
177Supply of float valve for low level cistern
178Supply of syphon for low level cistern
179Supply of syphon washer forcistern
180Supply of handle and lever for low level cistern
181Supply of steel jaali:100mm dia
182Supply of G.I. flange :50 mm dia
183Supply of G.I. flange :80 mm dia
184Supply of G.I. flange :100 mm dia
185Supply of G.I. reducer : 50 *25 mm dia
186Supply of G.I. reducer : 80 *25 mm dia
187Supply of G.I. bend :50 mm dia
188Supply of G.I. bend :80 mm dia
189Supply of G.I. bend :100 mm dia
190Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :Old work (one or more coats)
191Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. Old work (one or more coats applied @ 0.83 ltr/10 sqm).
192Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
193Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
194Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness
195Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
196Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
197Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
198Rough dressing the trenched ground including breaking clods.
199Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation
200Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately)
201Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.
202Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide will be provided by the Department & lawn mover and brush cutter with fuel , other T & P material/articles shall be provided by the contractor.) Play grounds / Public parks (as per yard stick 1Mali =2.00Acre).
203Maintenance of potted plant Earthen pot in displayed at ground floor only in bungalow,office complex including application of good earth, manure, insecticide, pesticide and fertilizer, removing of dry parts by pruning, cleaning dry leaves and displaying in appropriate place and replacement of broken pots coloring of pots and change of location of pots and replacing with fresh plants as and when required ( Materials shall be provided by the epartment) as per direction of officer in charge (For Earthen pot 750 Nos)
204Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately)
205Supply of Plants- Winter season (1 Tray) Marigold Inca hybrid
206Supply of Plants- Winter season (1 Tray) Gazania hybrid
207Supply of Plants- Winter season (1 Tray) Salviya
208Supply of Plants- Winter season (1 Tray) Rose
209Supply of Plants- Winter season (1 Tray) Dahelia
210Supply of Plants- Winter season (1 Tray) Panzy
211Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarses and: 4 graded stone aggregate 6mm nominal size), reinforced with 7 Nos (3 nos horizontal & 4 nos vertical “U“ shape) M.S. wires of 3.5 mm dia as per design, including required formwork, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge. Top inside dia35cm, outer bottom dia 25cm, total height 35cm with wall thickness of 25.4 mm
212Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC Urea
213Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC DAP
214Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC BoneMeal
215Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC NPK
216Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC NeemKhali
217Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC SarsoKhali
218Supply of insecticides/fungicides, pesticides and fertilizers from authorised dealers at site as per instruction of EIC Indocell
219Supply of Plants in summer season Kochia
220Supply of Plants in summer season Sunflower
221Supply of Plants in summer season Bulsum
222Supply of Plants in summer season Zinnia
223Total impact of GST for the purpose of CTC