| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling. ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 3 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plint level:1:2:4 (1 Cement : 2 Coarse sand (Zone-III) : 4 graded stone aggregate 20mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement-all work up to plinth level. 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate) |
| 6 | Centering and shutteringincluding strutting, propping etc and removal of form for Foundations, Footings, bases of columns etc for mass concrete |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached plasters buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate) 20mm nominal size |
| 8 | Centering and shutteringincluding strutting, propping etc and removal of form for columns, pillars, piers,abutments, posts and struts |
| 9 | Providing designation 75 A brick work in C.M(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of Screening materials, scafolding, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15º landings, balconies, shelves, chajjas,lintels, bands, plain window sills, stair cases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate)20mm nominal size |
| 11 | Centering and shutteringincluding strutting, propping etc and removal of form for Lintels, beams, Plinth Beams, girders, bressumers and cantilevers |
| 12 | Prov Tor steel reinforcement of 8mm dia as per approved -do- TMT FE 500 (Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) |
| 13 | Prov Tor steel reinforcement of 10mm, 12mm and 16mm dia bars as per approved design and drawing -do-do-(b) 12mm (TMT Coil Fe 500)(Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 10mm |
| 14 | For 12mm |
| 15 | For 16mm |
| 16 | For 20mm |
| 17 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 18 | Providing designation 75A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 19 | Providing 12mm thick Cement Plaster (1:3) with 1.5mm cement punning in skirting/dado all complete as per direction of E/I |
| 20 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I |
| 21 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm M.S. square bars fitted on 25x25x6mm M.S. Angle frame of size 60x60x6mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I (when steel is not supplied by the deptt.) |
| 22 | Providing two coats of synthetic enamel paint & Providing primer one coat of red lead paint approved shade and made over steel surfaceincluding cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I |
| 23 | Supply of CA sheet and labour cost for fitting and fixing CA sheet |
| 24 | Providing and fixing ridges and hips in fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. |
| 25 | Supplying materials and labour for construction of 600x600x90mm stop cock chamber of brick masonry with 125 mm thick work of designation 75B in cement mortar (1:6) with 12mm thick cement plaster in C.M. (1:6) on inside only having 50 mm thick R.C.C. cover having 12 mm dia lifting rings, 2 nos. stop cock chamber will rest over 80mm thick P.C.C. (1:3:6) over one brick flat soling, including cost of earthwork, all complete job, as per approved design, specification and direction of E/I. |
| 26 | Carriage of materialsa) Sand Lead 22 Km |
| 27 | b) Stone Chips Lead 22 KM |
| 28 | c) Bricks Lead 6 Km |
| 29 | Finishing walls with Acrylic Smooth exterior paint of required shade :Two or more coat applied @ 1.67 ltr/ 10 sqm)on existing cement paint surface |
| 30 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.External portion 15 mm dia |
| 32 | 25 mm dia |
| 33 | 26 mm dia |
| 34 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required Including the costof EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 35 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . 4.0 mm(Cost of aluminium snap beading shall be paid in basic item): |
| 36 | Supply, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I (Where materials is not supplied by the deptt.) |
| 37 | Fly proof wire netting in door and windowventilation with fly proof screen of18SWG x 12 to 16 mesh per cm2 sal wood beads all complete as per specification and direction of E/I. |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 39 | Providing 150mm wide brick drain in cement mortar (1.6) with av. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain duly plastered in CM (1:3) with punning over exposed surface all complete as per building specification and direction of E/I |
| 40 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. ot finished welded type tubes |
| 41 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms |
| 42 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 43 | Providing and fixing brass ferrule with C.I. mouth cover includingboring and tapping the main : |
| 44 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approvedquality for new work |
| 45 | Wiring for light point/fan point/ Exhaust fan point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano typeswitch, modular,phenolic laminated sheet with suitable size PVC/MS box etc as required.Group C |
| 46 | Wiring for circuit/submain wiring along with earth wire with the following size of FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required.2x2.5 sq.mm +1x2.5 sq.mm earth wire |
| 47 | 2x4.0 sq.mm +1x4.0 sq.mm earth wire |
| 48 | Supplying, providing and fixing of suitable size PVC/GI boxwithmodular plate cover in front on surface or in recess including providing and fixing 6 pin 15/16 amp modular socket outlet with 15/16 amp modular switchas required. |
| 49 | Supplying & fixing of following modular type switch/socket on the existing modular plateand switch box including connection etc as required.a) 5/6 Amp switch |
| 50 | b)5/6 Amp3 pin socket outlet |
| 51 | Supplying and fixing of following way,single pole and neutral sheet steel ,MCB distribution board ,240 volt on surface/recess complete with tinned copper busbar ,neutral bar (but without MCB/RCCB/ISOLATOR)6 way ,single door |
| 52 | 2 way ,single door |
| 53 | Supplying and fixing following 240 volts C series ,miniature circuit breaker suitable for inductive loads of following poles in existing MCB DB complete with connection as required.6/32 amps,Single pole |
| 54 | 32amps ,DP |
| 55 | Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe (with charcoal Or coke and salt ) as required. |
| 56 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode ,including soldering etc as reqired. |
| 57 | S.I.T.C of following rating LED Flood lighting luminaries with pressure die cast housing and toughened glass cover,IP 66 protection, LUMINIOUS EFFICARY 110LM/W, with lens in existing pole/pipe for supply voltage100-270v AC, 50Hz Luminaries shall confirm to IS;10322 part- 5/section-5 and shall be complete with allnecessary accessories as required.50/60W LED Flood light |
| 58 | 90/100W LED Flood light |
| 59 | Supplying FR PVC insulated 3 core 4 sq.mm copper wire (for flood light & service line ) |
| 60 | Supplying and fixing of cable junction box comlete with connection as required. MAKE –Sintex or equivalent. |
| 61 | SITC of following rating surface mounted LED Tube light fitting suitable for 230 V 50Hz single phase supply etc complete as required.20/22 W LED Tube Light |
| 62 | Supplying and fixing of 450mm (18’’)metal body wall fan with speed regulator suitable for single phase 220 V,50Hz Ac supply |
| 63 | Labour welfare fund |
| 64 | GST @ 18 % |