Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-06-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-06-2023 |
| 2 | 20-05-2023 | Amdt to Tender | Other | 03-06-2023 |
| 3 | 20-05-2023 | Amendment to date | Date | 03-06-2023 |
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified and directed. |
| 2 | Taking down old shutters of any description exc. 1 sqm but not exc. 2 sqm eachcomplete all as specified and directed. |
| 3 | M&L for framed work as in doors of angle or other section complete drilled for fixing sheeting with all fitting and fixturecomplete all as specified and directed. |
| 4 | S&F, 35 mm thick, 2nd class hard wood,glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a)complete all as specified and directed. |
| 5 | S & F35 mm thick plain, framed, panelled shutterswith lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of the members of shutter are as per IS-1003 (Part-I) made of kiln seasoned & chemically pressure treated 2nd class hardwood rail and stylecomplete all as specified and directed. |
| 6 | S&F for 35mm thick flush shutters, solid core construction, with blockboard core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 7 | S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solventement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, all as per manufacturer\"s instructioncomplete all as specified all as specified. |
| 8 | S&F PVC door frame size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinf with MS square tube supplying& fixing in opening as per specificationn make Rajshree. |
| 9 | S&FAluminiumanodised powder coatingany colour minimum coating 50 microndoor/ windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frame offixiing with handles, tower bolts, rubber gasketand maruti lock ,complete all as specified and directedetc completeNote :-Floor door spring, sheet glass, wire cloth,etc shall be measured and paid seperately. |
| 10 | M&L for anodised aluminium powder coated door shutters, aluminium section weighting 0.55kg/m,incl necessary, 5 mm thick, black tinted glass panes with nano coating &glazing or PVC sheet joining with cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, handles, lock, 2 x aluminium handles 150mm, 3 x hinges, 2 x Aluminium tower bolts 150mm with each shutter of any type complete all as specified all as specified. |
| 11 | S & F anodised aluminium powder coated window and ventilator shutters, sliding/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary, 5 mm thick, black tinted glass panes with nano coating& glazing, aluminium joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 No.), rollers etc complete all as specified all as specified |
| 12 | M&L for powder coated aluminium window sliding type (Bombay pattern) with frame of 1.5mm thick aluminium sections including 5.00mm thick tinted glass fixed with & including anodized aluminium snap beading, glazing clips, joining clips, screws, standard rubber gasket, handles/ Knobstwo nos. for each window and MS rollers two nos. for each window shutter etc complete all as specified and directed with following specifications:-(a) Aluminium section for window frame =101.50x44.45x2mm(b) Aluminium ventilator frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed.Make of aluminium sections:-M/S JINDAL or M/SHINDALCO or M/S INDAL as approved by GE. (c) Aluminium window frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed.Make of aluminium sections:- |
| 13 | Material & labour for box type steel window 1.25 mm thick made of ERW tube P-Section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter(two gauged shutters and two glazed shutter) of ERW tube P-Section size 50 x 20 mm and 1mm thick one/two Nos openable leaf consisting of two Nos sash bar of T-Section 20x3mm welded to frame with one No Vertical mullion of ERW box type T-Section of size 60 x 25 mm and 1.25 mm thick and FI 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like Handle, Tower Bolt, stopper, cleat, pintal hinges, hold fast etc. (a) Hold Fast, 150mm long of 120mm x 3 mm made to shape -04 Nos per window. (b) Handle of Z sec 20mm x 25mm, 100 mm long -1 No per leaf (c) MS Tower bolt 150mm long - 2 No per leaf (d)Z Sec 20mm x 25 mm, 100 mm long stopper - 1 No per leaf (e)Cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge -1 No per leaf. (f)MS Pintal hinges of size 75mm x 12mm - 2 Nos per leaf(g) 10 mm square guard bar, 10 cm centre to centre.(h) 25x4 mm flat iron all around for joint of both frame.(j) One coat of Red oxide primer to MS window and guard bar.Note :complete all as specified and directed by Engineer-in-charge. |
| 14 | S &F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 15 | S&F in repair for3mm thick, sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.5 Sqm in each pane fixed with oil putty or beads and incl hacking out glass old complete all as specified and directed. |
| 16 | S&Fin repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main bodywith stainless steel cover,governing pivot made of brass, other parts made of mild steelheavy duty and fixed |
| 17 | S&F, stainless steel butt hinges of size 100mm complete all as specified and directed. |
| 18 | S&F mild steel cold rolled medium weight butt hinges 100mm size fixed screws to wooden frames or with welding to steel frames all as specified and directed by Engr-in-charge. |
| 19 | S & F aluminium handle cast type anoodised 150mm size ISI mark complete all as specified and directed. |
| 20 | S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed ISI marked complete all as specified and directed. |
| 21 | S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. |
| 22 | S&F in repairs 300mm long mild steel ordinary rat tail rod pattern spring with roller plateincluding fixing with nails/ bolts or welded complete all as specified and directed. |
| 23 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 24 | M & L for brick work with sub class \"B\" bricks in CM (1:6) straight or curved on plan exc 6 mtrs mean radius,complete all as specified and directed. |
| 25 | M&L for Brick work with old size, sub class \"B\" bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) but except bricks complete all as specified and directed. |
| 26 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls built in CM 1:4 complete all as specified and directed. |
| 27 | Taking down cement plaster on brick/stone/concrete walls incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc.500 mtrs where directed complete all as specified and directed. |
| 28 | M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick or concrete workand finishing the surface even and smooth (without using extMR cement) incl WPC @3% weight of cementetc.complete all as specified and directed. Note-WPC will be measured and paid separately under appropriate items |
| 29 | M&L for 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extMR cement) etc. complete all as specified and directed. |
| 30 | M&L for 10 mm thick cement plaster in CM (1:3) onconcrete surfaces of ceilingand finishing the surface even and smooth (without using extMR cement) etc complete all as specified and directed. |
| 31 | Supply only, integral water proofing compound. complete@ 3 % by weightcementroof and parapet/ vertical surfaces and like complete all as specified and directed. |
| 32 | M&L for Applying 1 mm thick wall care putty to achieve even and smooth surfaces on old scraped surfaces or new plasterd surfaces and obtain using sand paper complete all as specified and directed. Note-Entire spalashes in floor shall be cleaned immediately after completion of periodical services. |
| 33 | Material and labour for repairing of RCC projection, chajjas, facia,bands, shelves, beams, slab ,RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion RCC at any height and in any sitution floor (including provn of support,formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ fillingwith PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thickafter applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of wheater proof emulsion paint to match with existing surfaces complete all as specified and directed. |
| 34 | M & L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 35 | M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper complete all as specified and directed. |
| 36 | M&L fortwo coat ofweather proof exterior emulsion paint incl preparation of new plastered wall surface complete all as specified and directed. Note : Colour and make as approved by GE |
| 37 | M&L forOne coat ofweather proof exterior emulsion paint incl preparation of old wall surface complete all as specified and directed. Note : Colour and make as approved by GE |
| 38 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 39 | Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer. |
| 40 | M&Lfor preparation of old woodensurfaces of exceeding 10cm width or girth and applying one coat of synthetic enamell paint complete all asspecified and directed. |
| 41 | M&L for preparation of old steel surfaces of exceeding 10cm width or girth and applying one coat of synthetic enamell paint complete all asspecified and directed. |
| 42 | M&L for applying two coat of cement base paint on walls, pillars cornices etc surface incl preparation of old plastered surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and incl filling necessary where required with putty as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed. |
| 43 | M&L for applying one coat of oil bound distemper on walls, pillars cornices etc surface incl preparation of old plastered surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and incl filling necessary where required with putty as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed. |
| 44 | M&L for Prepration of old surfaces of ceiling includinng scrapping down smoke ,soot,and efflorescent salts and treatings oil and gresy spots, brooming down or steel wire brushing removing nails making good holescracks etc on plastered or unplastered surfaces and applying two coat of white wash on ceiling surfacecomplete all as specified |
| 45 | M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge,inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as requiredat site complete all as specified and directed |
| 46 | M&L for marble Green/white/black colour or any shadeshade of thickness 17-20 mm thick in slab laid over 15mm thick screed bed in cement mortar 1:6 as in floor, steps, riser & treads and jointed in neat cement slurry and pointed in white or coloured cement to match incl dismantling / demolition and rubbish off the primisesand rounding to edges of stone slabs one edge such as in counter type WHB platform etc. to the entire satsfaction of Engineer-in-Charge.. etc complete all as specified and directed. Note-size of slab will be decided by Engr-in-Charge. |
| 47 | M&L for Granite 15-20 mm thick (table rubbed and polished)in steps, jambs, pillars, window cills, cooking platforms, wash basin platform, treads, risers and like laid in cement 15 mm thick cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite rounding to edges of granite stone slabs one edge such as in counter type WHB platform etc. incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 48 | M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 09 sqm but not exceeding 0.11 sqm, in floors etc. laid over 15mm thick screed bed in cement mortar 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 49 | M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc. laid over 15mm thick screed bed in cement mortar 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 50 | M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 7mm thick verticale tiles with highlighter any colour on vertical surface such as skirting, dados, risers to steps etc set &jointed in neat cementslurry and pointed inwhite or coloured cementto matchincl dismantling / demolitionand e colour oftiles,incl dismantling / demolitionover and includingrendering10mm thick in cement mortar (1:4), complete all as specified and directed. |
| 51 | M&L vetrified ceremic tiles 8 to 10 mm thick, in(Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to matchincl dismantling / demolition, coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed. |
| 52 | M&L for Vitriefied ceramic tiles 8 to 10mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqmas in vertical surfaces such as dados/skirting etc set and jointedin neat cement slury and in coloured cement to matchincl dismantling / demolition, Coloured on incl plaster (backing coat) 1:4 CM 10mm thick |
| 53 | M&L for 25mm thick cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in sub baseto receive floor finishes complete all as specified and directed. |
| 54 | M & L machine pressed coloured chequered tiles of size 300 x 300 x 25 mm thick laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurryincl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 55 | S&F machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade over 25mm thick sand cushioning and joint filled with dry sand mortar 1:4, incl dismantling of stone slab and tiles of any description of thickness in floors/aprons etccomplete all as specified and directed. |
| 56 | M&L for 50mm thick PCC 1:3:6, Type C-1 (using 20mm graded aggregate) as in Plinth protection, making even and smooth surface without using extMR cementincl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 57 | M & L forPlain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concreteincluding dismantiling PCC complete all as specified and directed. |
| 58 | S&F 15mm bore tubing medium grade galvanised steel tubing with all fittings and fixed to walls, ceiling and in floor incl cutting, chasing in wall, floor or ceiling and making goodin CM 1:3 incl taking down old pipe complete all as specified and directed. |
| 59 | S&F 20 mm bore tubing medium grade galvanised steel tubing with all fittings and fixed to walls, ceiling and in floor incl cutting, floor or ceiling and making goodin CM 1:3incl taking down old pipe complete all as specified and directed. |
| 60 | Supplying , fixing & Hoisting and fixingin position and connecting, in repairs, 500 litres capacity rotational moulded polyethylene water storage tank triple layer (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I including 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixedcomplete all as specified and directed. |
| 61 | Supplying , fixing & Hoisting and fixingin position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank triple layer (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixedcomplete all as specified and directed. |
| 62 | Dismantling brick tiles or terracing single layer as in roofing complete all as specified and directed. |
| 63 | Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. |
| 64 | M & L for 40 mm avarage thicknessPCC 1:2:4type B1 (using 20 mm graded stone aggregate as roof padding ,hunching, sub base floor complete all as specified and directed. |
| 65 | M&L for water proofing treatment to non-accessible /accessible roofslabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.30 Ltr/Sqm and applying of one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm and laying of actetic polypropylene (APP) modified membrane pre-fabricated, reinforced with non-woven polyester of 3.50Kg/Sqm (minimum), 3mm thick (minimum), with minimum 75mm side overlaps and 100mmend overlaps and applying one coat of bituminous aluminium paint over APP membrane complete all as specified and as directed. |
| 66 | M&L, 40 mm thick brick tiles laid and joints in cement mortar (1:6) over 15mm thickand jointed grouted flush pointing in cement Motar (1:3) completed all as specified and directed. |
| 67 | Description all as per Srl item No 66.00 above but except bricks tiles complete all as specified and directed. |
| 68 | M&L of 25mm plain Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in levelling courseincluding dismantiling of old PCC complete all as specified. |
| 69 | M & L for applying two coat of undiluted thick coat of acrlic reinforcement liquid applied elastorneric water proofing membrane with UV resistance properties and solar refective properties over one coat of primer (1:3, Dilution:water) Note: Every each coat gap between 6 hrs) complete all as specified and directed. Make : Asian paint, Sika, Fosroc |
| 70 | S& F, in repair vitreous china urinals, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement incl flush pipe, grating, waste coupling and union for discharge pipe complete all as specified and directed by Engr-in-charge. |
| 71 | S & F in repairvitreous china warecounter ovel wash hand basin, any colour, size 570 x 450 mm sizefixing in slab including fixing waste pipe , CP waste coupling all as specified and approved by Enger-in-Charge |
| 72 | S & F in repair for viterous china wash hand basin white flat back size 550 x 400 mm incl CP waste coupling, waste pipe & plug and porclain stopper brackets and cutting for and pinning in ends of brackets or erceting stand fixed complete all as specified and directed. |
| 73 | S & F in repairfor viterous china squating pan of (Orrissa Pattern) size 580 mm white with \"P\" or \"S\" trap front or back inlet and integral foot rest ,including joining, filling and provision of cement concrete bedding 1:5:10, type E2 (excluding flushing cisteern and flush pipe) fixed inclcement concrete bedding as required set complete all as specified and directed. |
| 74 | S & F in repair for viterous china wash down water closet pan (pedestal pattern) coloured including\"P\" or \"S\" trap with flush pipe of chromium plated brass 32 mm dia for low levelflushing cistern incl plastic seat cover white closed pattern with float bottom and cover and jet connection and mild steel chrominum plate or aluminized hanging device fixed in repairs complete all as specified and directed. |
| 75 | S&F in repair10 ltrs capacity PVC valveless. Syphonic action type, flushing cistern, lowlevel, with inlet, ball valve, float, and handle and bracketsincluding 32mm dia flush pipe of polyethylene ofhigh density for low level cistern complete all as specified and directed by Engr-in-charge. |
| 76 | S&Fin repair 450mm long PVC connections with PTMT nuts of suitable for 15mm bore dia pipe complete all as specified and directed. |
| 77 | S&F in repair central hole basin mixer cast copper alloy chromium, plated fancy type with regular spout without pop up waste system with 450 mm long braided hosescomplete all as specified and directed |
| 78 | S&F, in repair, vitreous china full padestalwall hung basin white with fixing accessories of size 610 mmx 480mm X 1950mm , counter top basin,grouted in cement mortar 1:2 complete all as specified and directedNote :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately. |
| 79 | S & F in repairbrass Chromium plated shower rose 125 mm size with or without swivel joints, any size with arms , including fixing to steel pipe or union complete all as specified and directed |
| 80 | S&F in repair, overhead shower 150mm x150mm square shape single flow (ABS body chrome plated with gray face plate ) incl shower arm 190mm long with rubit cleaning system complete all as specified and directed. |
| 81 | S&F in repairs, brass chromium plated single lever wall mixer3 in 1 system with provision of both over head showerand hand shower with 115 mm long bend pipe connecting legs and wall flange(wihout hand and over head showercomplete all as specifed and directed. |
| 82 | S&F, in repairs, brass, chromium plated tubular towel rack20mm dia 60cm long between flanges complete all as specifed and directed. |
| 83 | S&F, in repair, chromium plated, Toilet paper holder complete all as specified and directed. |
| 84 | S&F in repairTowel ring round with round flangecomplete |
| 85 | S&F, in repair, CP, soap dish holder complete all as specified and directed. |
| 86 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified. |
| 87 | S&F, in repair, chromium plated glass corner (Corse) size 300mmx300mm complete all as specified and directed. |
| 88 | S&F in repair, 1600mm x 1100mm plain edge mirror of selected quality glass not less than 5.5mm thick, mounted on wall fixed with stainless steel studany sizecomplete all as specified and directed. |
| 89 | S & F in repair 15mm bore dia cast copper alloy chromium, plated fancy type long body bib tap with crutch or buttewrfly handle screwed down to iron pipe with all fittings complete all as specified and directed. |
| 90 | S & F in repair 15 bore dia cast copper alloy chromium, plated fancy type Stop cock/Angle cockscrewed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed. |
| 91 | S& F for in repair swan neck pillar cock chromium plated fancy type screw with iron pipe incl all fittings complete all as specified and directed. |
| 92 | S&F in repairs chromium plated Urinal spreader for fixing with 15 mm dia bore pipe complete all as specified and directed by Engr-in-charge. |
| 93 | S&F, in repair, 25 mm dia, 1 mm wall thickness stainless steel fancy type, decorative curtain rod with decorative ball type side brackets (As per Sample) fix with wooden gutties complete all as specified and directed. |
| 94 | S & F 75 mm bore PVC (SWR)pipes single socketed in any length with rubber ring joints and necessary fittings laid in floors/Wall or trenches incl taking down old pipe complete all as specified and directed. |
| 95 | S & F 110 mm bore PVC (SWR)pipes single socketed in any length with rubber ring joints and necessary fittings laid in floors/wall or trenches incl taking down old pipe complete all as specified and directed. |
| 96 | S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed. |
| 97 | S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed. |
| 98 | S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 99 | S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 100 | S&F 75mm bore PVC (SWR) vent cowlcomplete all as specified and directed. |
| 101 | S&F 110 mm bore PVC (SWR) vent cowlcomplete all as specified and directed. |
| 102 | S&F, in repair Health Faucet/hand shower with 8mm dia 1mtr long easy flexible tube with chrome finish & wall hook complete all as specified and directed. |
| 103 | S&F in repair for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour profile AZ-150 with side lap as in roof covering/ cladding to wall, fixed with \"L \"or \"J\" hooks / self tapping screws and incldismantling of plain or corrugated steel sheeting in roof covering all as specified and directed by EIC. |
| 104 | Material & labour for gypsum board panel 12 mm thick as in ceiling including T section accessory of galvenised mild steel, GIsuspender all as per manufacturer design confirming to IS 2095 and IS 2542 – 1981. Weight of board not less than 7 Kg per Sqm including two coat of Oil bound distemper over a coat of plaster of pariscomplete all as specified and directed. Note: - Rate quoted shall be deemed to be inclusive of gypsum board, frame work and suspender. |
| 105 | S&F ornamental stainless steeltubular pipes/sheets, pieces suchas pipe caps globe at top 18 guage and grade304 as in staircase railing including welding , moulding riveting nut and bolt with all necessary fittingcomplete as shown directedby Engineer-in-Charge |
| 106 | S&F, in repair, single action spring hinges, mild steel with steel wire spring, stove enameled black, size of spring hinge 150mm all as specified and directed. |
| 107 | Mechanized cleaning and disinfection of Water Storage Tank : 1. Mechanized Dewatering of water storage tank. 2.Removal of sluge laying on the bottom ofwater storage tankthrough special sludge pumps. 3.Cleaning of internal walls of water storage tank through High Pressure rotary Jets 4.Vaccum cleaning of the floor of water storage tank through industrial vaccum cleaners.5.Spray of H2 O2 inside the tanks as an antibecterial agent.6. UV radiation of the tank. 7.Spray of bleaching powder in prescribed quantity after final cleaning of the tank.Notewriting the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed. |
| 108 | 500 ltr capacity |
| 109 | 1000 ltr capacity |
| 110 | S&F in repair Mortice lock,vertical type, size 100 mmdoor lock 4 lever baras complete all as specified and directed. |
| 111 | Refixing of shutter including taking downeasening and adjusting and also refixing handware as required including renewal of unservicebale screws etc of any description exc 1.0 sqm but n exc 2.0 sqm each in same opening all as specified and directed |
| 112 | Taking down aluminium door shutter of any sizesincluding floor door closer, removing galss with beading before taking down and refixing of glass, beading and floor door closer after replacing broken parts of aluminium shutter including easing of shutter complete all as specified. |
| 113 | M&L, in repair,75 /100 mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement all as specified and directed. |
| 114 | M&L, in repair,PVC (SWR) gully trap , square or round mounthed, any type of size 125 x 100mm, setting and jointing with tting and jointing with solvent cement cement (1:1) complete all as specified and directed. |
| 115 | M&L for plain cement concrete (1:5:10) type D-2 using 40 mm graded stone aggregate as in filling in sunken floors including demolition of cement concrete (unreinforced) in ground floor and pavings any thickness (below or above ground level) complete as specified and directed. |
| 116 | M&L for 15MM thick rendering in CM (1:3) on brick or concrete surfaces in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick, finishing the surfaces with even and smooth withusing extra cement complete all as specified and directed. ( Note:- WPC measured separately) |
| 117 | M&L for Bitumen blown any grade , applied hot, two coats to concrete surfaces at the rate of 1.5Kg sqm per coat. Including polythene film, black , 50 micron laid in floors. all as specified and directed. ( Note:- WPC measured separately) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail