| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-05-2023 | Revised Tender Opnening Date | Date | 24-05-2023 |
| Sl. No. | Item Description |
| 1 | Earthwork excavation and depositing on banks with as initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stoney earth, earth mixed with small sized boulders and hard gravelly soil to a depth of 1.05m and 0.75m width as per SS 20 B-for pipeline and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. - For 100mm dia DI Pipes |
| 2 | Earthwork excavation and depositing on banks with as initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stoney earth, earth mixed with small sized boulders and hard gravelly soil to a depth of 1.20m and 0.80m width as per SS 20 B-for pipeline and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. For 250mm dia DI Pipe |
| 3 | Earthwork excavation and depositing on banks with as initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stoney earth, earth mixed with small sized boulders and hard gravelly soil to a depth of 1.35m and 0.80m width as per SS 20 B-for pipeline and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. For 300mm dia DI Pipe |
| 4 | Supplying and conveying of 100mm dia in size of DI K7 Class pipes to site confirming to specifications as per IS 8329:2000 for standard length including cost of pipe, testing charges at factory, labour charges for loading, unloading and stacking at site but excluding the excise duty and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 5 | Supplying and conveying of 250mm dia in size of DI K7 Class pipes to site confirming to specifications as per IS 8329:2000 for standard length including cost of pipe, testing charges at factory, labour charges for loading, unloading and stacking at site but excluding the excise duty and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 6 | Supplying and conveying of 300mm dia 2.50m length in size of Ductile Iron Class PN10 Flanged Pipes to site confirming to specifications as per IS 8329:2000 for standard length including cost of pipe, testing charges at factory, labour charges for loading, unloading and stacking at site and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 7 | Lowering of 100mm dia DI pipes and specials in the trenches and laying to proper grade and alignment and as directed by the officers. |
| 8 | Lowering of 250mm dia DI pipes and specials in the trenches and laying to proper grade and alignment and as directed by the officers. |
| 9 | Lowering of 300mm dia DI pipes and specials in the trenches and laying to proper grade and alignment and as directed by the officers. |
| 10 | Jointing the 100mm dia DI pipes and specials with Socket & Spigot ends (tyton rubber joints) including cost of jointing materials such as lubricants, rubber gaskets and testing to the required pressure including conveyance of water for filling during testing, labour charges and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 11 | Jointing the 100mm dia C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) and testing to the required pressure including conveyance of water for filling during testing, labour charges and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 12 | Jointing 100mm dia C.I/ D.I double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete including charges for special tools and plants such as air compressor and helmets and sheet piles. etc (including cost of jointing materials) and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 13 | Jointing the 250mm dia DI pipes and specials with Socket & Spigot ends (tyton rubber joints) including cost of jointing materials such as lubricants, rubber gaskets and testing to the required pressure including conveyance of water for filling during testing, labour charges and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 14 | Jointing the 250mm dia C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) and testing to the required pressure including conveyance of water for filling during testing, labour charges and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 15 | Jointing 250mm dia C.I/ D.I double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete including charges for special tools and plants such as air compressor and helmets and sheet piles. etc (including cost of jointing materials) and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 16 | Jointing 300mm dia C.I/ D.I double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete including charges for special tools and plants such as air compressor and helmets and sheet piles. etc (including cost of jointing materials) and all other incidental charges etc., complete as per standard specifications and as directed by the Engineer. |
| 17 | Refilling the pipeline trenches with excavated earth for 100mm dia DI Pipe complying with standard specifications. |
| 18 | Refilling the pipeline trenches with excavated earth for 250mm dia DI Pipe complying with standard specifications. |
| 19 | Refilling the pipeline trenches with excavated earth for 300mm dia DI Pipe complying with standard specifications. |
| 20 | Supply and delivery of CI D/F sluice valves with cap along with specials of the 100mm dia in size confirming to IS 14846 / 2000 (PN1) including flanged tail piece and other specials as required, loading, unloading, transportation charges and stacking and jointing including cost of jointing materials but excluding excise duty etc, complete as per standard Specification. |
| 21 | Supply and delivery of CI D/F sluice valves with cap along with specials of the 250mm dia in size confirming to IS 14846 / 2000 (PN1) including flanged tail piece and other specials as required, loading, unloading, transportation charges and stacking and jointing including cost of jointing materials but excluding excise duty etc, complete as per standard Specification. |
| 22 | Supply and delivery of CI D/F sluice valves with cap along with specials of the 300mm dia in size confirming to IS 14846 / 2000 (PN1) including flanged tail piece and other specials as required, loading, unloading, transportation charges and stacking and jointing including cost of jointing materials but excluding excise duty etc, complete as per standard Specification. |
| 23 | Supply and delivery of CI D/F Scour valves with cap along with specials of the 125mm dia in size confirming to IS 14846 / 2000 (PN1) including flanged tail piece and other specials as required, loading, unloading, transportation charges and stacking and jointing including cost of jointing materials but excluding excise duty etc, complete as per standard Specification. |
| 24 | Manufacture, supply and delivery of 50mm dia Double Air Valve as per ISI 14845/2000 of flanged type with screw down valves combined as per G.K. catelogue Fig. No. H40 and tested to a minimum test pressure of 120m of head of water including loading freight, unloading, insurance all taxes stacking at site but excluding excise duty etc., complete and as directed by the departmental officers. |
| 25 | Supplying and delivery of DIS/S and D/F pipes and specials at site of work for pipeline works as per IS 9523/2000 and labour charges including loading freight, unloading, insurance all taxes stacking at site but excluding excise duty etc., complete and as directed by the departmental officers. |
| 26 | Constructing masonry chamber of inside dimensions as mentioned below with Country Brick, brick work in CM 1:5 (1 cement : 5 M - sand) for sluice valve, with CI Surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and top RCC Precast slab in M20 with necessary earth work excavation including refilling the sides of foundation, foundation concrete 1:4:8 (1 cement : 4 M - sand : 8 grade stone aggregate 40mm nominal size) and inside plastering with CM 1:5 (1 cement : 5 P- sand) 12mm thick finished with a floating coat of neat cement, complete as per standard design and shown in the drawings. 1500 x900 x 1500mm clear inside dimensions. |
| 27 | Testing of 100mm dia D.I pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretchesand attending thebursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete |
| 28 | Testing of 250mm dia D.I pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretchesand attending thebursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete |
| 29 | Labour for cutting open BT or Maccadam roads for laying water distribution lines etc complete as per standard specifications and as directed by the Departmental Engineer. |
| 30 | Conducting Geophysical survey, quality and quantity test and transportation charges etc, (This includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist) |
| 31 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc.By first taking a pilot bore of 140 mm/150mm dia and then enlarging to 200mm dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site including construction of mud pit. - Upto 60m Depth. |
| 32 | Supply and delivery of unplasticised ribbed screen PVC casing pipe of the 200mm dia with screwed and socket end and centering guide for every 15m length of pipes as per IS / 12818 / 92 and as amended from time to time to suit the borewell upto 80m depth (C.M) with ISI marking including, loading, unloading, freight, stacking and transit insurance charges etc, complete. |
| 33 | Labour Charges for inserting PVC casing pipes of 200 mm OD PVC Casing Pipes Assemblyassembly (with slots or without slots) in the drilled hole including the jointing the pipes with PVC couplers with cement paste etc. complete. |
| 34 | Reaming140/150mm dia pilot bore to 300mm dia bore as directed by the Departmental Board Officer. |
| 35 | Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by Departmental Officers and conducting yield test by \"V\" notch method. |
| 36 | Supply and fixing of G.I. pipes (Medium)of 100mm dia in size as per IS 1239 / Part I / 90 for submersible pump in Bore well . The rate shall inclusive of all labour charges and freight charges etc, complete. |
| 37 | Supply and delivery of Bore well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging 300LPM X 40m Head of following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump is suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. |
| 38 | Supply and laying of PVC insulated and sheathed 3 core 16 sq.mm Flat type copper cable confirming to IS 694/ 1990 etc complete as per standard specification. |
| 39 | Supply and laying of L.T. cables 3 core 35 sq.mm 1.1KV grade armoured aluminium conductor cable confirming to IS 1554 part I with ISI markingetc complete as per standard specification. |
| 40 | Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging 300LPM X 40m Head of following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump is suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. |
| 41 | Labour charges for the erection of 5.0Hp submersible pump set in bore well/open well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventer, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. |
| 42 | Supply and delivery of Fully Automatic Auto Transformer Starter suitable for 5.0HP the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components etc. under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. |
| 43 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil,wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depthwith intiallead and lifts and cleaning and levelling the site and refilling etc.,complete - Narrow Foundations- Upto 2.00m Depth |
| 44 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil,wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depthwith intiallead and lifts and cleaning and levelling the site and refilling etc.,complete - Open Earth work Excavations - Upto 2.00m Depth |
| 45 | Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted, including cost and conveyance of sand to site incluidng labour charges etc., complete complying with standard specification. |
| 46 | Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 47 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plain SurfacesBelow GL |
| 48 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For Curved surfaces such as RCC floor slab, roof slab, beams, etc. |
| 49 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For Vertical Surfaces, etc. |
| 50 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. |
| 51 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For Circular RCC columns,etc. |
| 52 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. |
| 53 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of crushed stone sand (M - Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards. - Upto Basement |
| 54 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of crushed stone sand (M - Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials) - Ground Floor |
| 55 | Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification |
| 56 | Fabrication,supply, delivery and fixing of outside M.S. Ladder of 45cm clear wide made out of 50mm x 50 mm x 6mm M.S. angle for sides and steps in 16mm MS plain rods fixed at 30 cm C/C welded jointed etc., providing with suitable side supports, clamps and locking arrangements provided with two coats of approved enamel paint over one coat of redoxide paint, for providing access to roof top of OHT of suitable inclined length, including bottom anchorage and transportation and as directed by TWAD Board Officers. The rate inludes concrete bed block in CC 1:2:4 using 20mm HBGS at top and bottom of suitable size with necessary anchor bolts. |
| 57 | Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 60 X 60cm in size in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), of best approved quality and as per standard specifications etc.,complete. |
| 58 | Providing Fusion Bonded Epoxy coating not less than 175microns thickness and upto 300 microns to reinforcement of all diameters as per IS 13620/1993 including testing of coating at plant.The cost is inclusive of cost on account of careful handling, PVC coated binding wires, touchup material supplied by coating agency, repair work, loading, unloading and strengthening of bent rods etc., complete as per specification and as directed by the Engineer in charge. (inclusive of all taxes) -For 8mm to 16mm |
| 59 | Providing PVC ventilating arrangements mosqutio proof nylon net with 110mm PVC pipes and cowl and as directed by Municipal Officers. |
| 60 | Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M- Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 61 | Providing and fixing of RCC inner access ladder in RCC M20 Grade Concrete Mix as per the standard specifications for OHT including grill in position, centering, shuttering charges, mixing concrete curing etc, to required height and clear width of 45cm consisting of two nos of vertical post of 10cm X 15cm and step salb of 25mm X 25mm etc,complete and as directed by Municipal Officers. |
| 62 | Providing Cut stone set in CM 1:3 (one cement and three sand) using well dressed cut stone supporting inlet pipe of size 0.30 x 0.30 x 0.15m for service reservoir etc., complete as per standard specifications and as directed by Engineer-in-charge. |
| 63 | R.C.C.Jolly by a new of followingsize in R.C.C. 1:1.5:3 using 20mm gauge hard broken granite stone jelly and crushed sand (M- Sand) excluding cost of reinforcement but including charges, fabrication chargescuring neat finishing and labour charges for fixing the jolly in position with standard specification |
| 64 | Plain Cement Concrete 1:2:4 (one part of cement, Two part of Crushed Stone Sand (M- Sand) and Four part of coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 65 | Supplying and filling the basement with Good Earth filling in layers of not more than 15cmthick well rammed watered and compacted - etc., complete complying with standard specification. |
| 66 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) - Upto Basement |
| 67 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost)- Ground Floor |
| 68 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) - First Floor |
| 69 | Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three plastering sand (P- Sand)) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 70 | Plastering with cement mortar 1:5 (One cement and five plastering sand (P- Sand)) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications |
| 71 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness 80mm as directed by the departmental officers.etc., complete. |
| 72 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three plastering sand (P- Sand)) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 73 | Supply and Delivery Fabrication of MS doors with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete - 0.90 X 2.10m |
| 74 | Supply and Delivery Fabrication of MS windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete - 1.20 X 0.90m |
| 75 | Painting two coats of newly plastered wall surface with approved Emulsion paint over cement plastered wall surface, ceiling andincluding preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required and cost of painting materials, brushes, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer |
| 76 | Painting the new iron work with two coats of best pproved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. |
| 77 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 78 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23 |
| 79 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38 |
| 80 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. SD 54 |
| 81 | Supply and fixing of single box type 4\"36 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting SD 87 |
| 82 | Supplying and fixing of 1200mm ( 48\"\" ) sweep AC ceiling fan complete with regulator with 1M down rod including S & F of fan clamp with side plates and cross arm SD 107 |
| 83 | Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work.SD 234 |
| 84 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (lik standard make) SD. 179 |
| 85 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m SD.75 |
| 86 | Supply and run of 4 X 6 sq.mm (84/0.3) 7/20sqmm PVC unshealed copper cable in suitable PVC rigid pipe concealed on wall and ceiling withcontinuos earth wire connection of 14 SWG TCwire with painting of suitable colour SD 68 |
| 87 | Wiring with 2 x 4sqmm (56 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for15A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC power plug point.SD 40 |
| 88 | Supply and fixing of TNEB Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2\" x 1 1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units(500V) 1 No. Neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete.SD 129 |
| 89 | Supply and fixing of 32 A TPN MC switch on incoming and 3 Nos 32 A DPMC Switch (Front Handle) as outgoing with suitable adoptor box with suitable MS cable entry box trunking boxes and internal connections on internal connections on suitable AI frame work with earth connection etc,complete.SD 172 |
| 90 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry . SD 233 |
| 91 | Providing and fixing in position of PVC water bar 150mm wide with single bulb for horizontal joints necessary holders fabrication, the rate inclusive of cost of water bar, holders fabrication and fixing in position etc complete as per standard specification and as directed by the Engineer. |
| 92 | Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging 1500LPM X 80m Head of following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump is suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. |
| 93 | Labour charges for the erection of 40.0Hp submersible pump set in bore well/open well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventer, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. |
| 94 | Supply and delivery of Fully Automatic Auto Transformer Starter suitable for 40.0 HP the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components etc. under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. |
| 95 | Supply and laying of L.T. cables 3 core 70 sq.mm 1.1KV grade armoured aluminium conductor cable confirming to IS 1554 part I with ISI markingetc complete as per standard specification. |
| 96 | Add GST. 18%(CGST-9%,SGST-9%) |