Tender For Repair Replacement Of Roof Sheets False Ceiling Eaves Board Roof Treatment Plastering Etc And Cleaning To Service Water Tanks Including Other Connected Water Supply Lines Tank Staging Concrete Platform Etc At Masimpur Military Station Unde, masimpur-Assam

Military Engineer Services-MES has published Tender For Repair Replacement Of Roof Sheets False Ceiling Eaves Board Roof Treatment Plastering Etc And Cleaning To Service Water Tanks Including Other Connected Water Supply Lines Tank Staging Concrete Platform Etc At Masimpur Military Station Unde. Submission Date for this Tender is 03-06-2023. Shed Construction Tenders in masimpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

37562746
Corrigendum : Tender For Repair Replacement Of Roof Sheets False Ceiling Eaves Board Roof Treatment Plastering Etc And Cleaning To Service Water Tanks Including Other Connected Water Supply Lines Tank Staging Concrete Platform Etc At Masimpur Military Station Unde
Open Tender
Indian
Assam
masimpur
03-06-2023

Tender Details

Repair / Replacement Of Roof Sheets, False Ceiling, Eaves Board, Roof Treatment, Plastering, Etc. And Cleaning To Service Water Tanks Including Other Connected Water Supply Lines, Tank Staging, Concrete Platform, Etc. At Masimpur Military Station Under Ge Silchar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-May-2023 BOQ CORRIGENDUM BOQ 27-05-2023
2 27-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF ROOF SHEETS, FALSE CEILING, EAVES BOARD, ROOF TREATMENT, PLASTERING, ETC. AND CLEANING TO SERVICE WATER TANKS INCLUDING OTHER CONNECTED WATER SUPPLY LINES, TANK STAGING, CONCRETE PLATFORM, ETC. AT MASIMPUR MILITARY STATION UNDER GE SILCHAR
Sl. No. Item Description
1Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
2Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
3Dismantling asbestos cement / PVC pipe 50/75/100mm dia including clamps from any position or any location and disposing off complete all as specified and as directed
4Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed
5Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering /wall cladding complete all as specified and as directed
6Dismantling asbestos cement (corrugated/semi corrugated) in roof coverings, etc including ridges, claddings, etc. and disposing offincluding all necessary staging / scaffolding, etc. as required complete all as specified and as directed
7Dismantling wooden boarding (eaves board, rafter, etc.) of any description fixed in any position with nails complete all as specified and as directed
8Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed
9Dismantling of timber fillets rails, posts, rafters, purlins, etc. under 40sqcm in section, in any position in unframed works complete all as specified and as directed
10Dismantling wall and ceiling boards (fibre,pulp, insulation, etc. or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. complete all as specified and as directed
11Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
12Taking down cement or cement lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
13Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
14Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
15Taking up or down 25mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
16M&L for disconnecting existing tanks of capacity exceeding 500litres to 1000litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required and reconnecting and re-fixing in position complete all as specified and as directed
17M&L for cleaning surfaces of RCC accessable roofs, walls, chajjas, etc. by removing unwanted growth of plants, weeds, shrubs, small trees, etc. brooming off and removing rubbish to a distance not excceeding 50m complete all as specified and as directed
18S&F mild steel works as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, plate washers and similar small articles conforming to Fe-290 grade-E-165 complete all as specified and as directed
19S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed
20M&L for framed works as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering conforming to Fe 410-W (grade E-250) quality-A complete all as specified and as directed
21S&F of mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins, brackets for fixing of eaves board, posts, etc. where connected to common rafters and other miscellaneous brackets fixed with angle cleats or other connecting plates conforming to Fe-290, grade E-165 complete all as specified and as directed
22M&L for mild steel TMT bars grade Fe-500D, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
23M&L for mild steel TMT bars grade Fe-500D, 8mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
24M&L for brickwork with sub-class "B" bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
25M&L for brickwork with sub-class "B" bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
26M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, landings and similar works, not exceeding 200mm thick (horizontal or sloping), for rough finished flat surfaces of concrete complete all as specified and as directed
27M&L for reinforced cement concrete M-25 (design mix) using 20mm graded stone aggregates as in slabs supported on walls, beams,column in floors, roof, landing, balconies, canopies, deck slabs, shelves and similar works comlpete all as specified and as directed
28M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and smooth, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed
29M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub-bases for floors, complete all as specified and as directed
30M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in surface channels, drains, etc. complete all as specified and as directed
31M&L for 100mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregates) as in path, hard standing, etc. finished making impression of expanded metal, whilst the concrete greenincluding necessary formwork, etc. complete all as specified and as directed
32M&L for 40mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregates) as in roof padding, haunching, roof kerb or similar works including applying 3kg/sqm neat cement slurry complete all as specified and as directed
33M&L for plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregates) as in benching, kerbs, levelling courses, etc. complete all as specified and as directed
34M&L for plain cement concrete 1:2:4 type B1 with 20mm graded aggregate as in coping over walls, benching including neccessary formwork complete all as specified and as directed
35M&L for laying pre-polished 60mm thick rubber moulded, double glossy, coloured, designer, interlocking tiles made of M-35 design mix concrete of approved design and shape with the crushing strength not less than 350kg/sqcm conforming to IS: 15658-2006, pointed in grey cement complete all as specified and as directed
36M&L for fine dry river sand bedding under floors, pavings, etc. then punning down to its consolidated thickness, 50mm thick complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
37Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed Note: Inner girth shall only be measured
38M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
39M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
40M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished fair and even without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
41Supply only integral water proofing compound all as specified
42S&F 2nd class hard wood 20mm thick boarding, plained one side. fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and as directed
43S&F 2nd class hard wood 50mm thick boarding, wraught, fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and as directed
44M&L for 2nd class hard wood timber scantling wrought in section, timber framed & fixed complete all as specified and as directed
45M&L for 2nd class hard wood timber scantling clean sawn in section, timber framed & fixed complete all as specified and as directed
46M&L for 2nd class hardwood fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 6sqcm and not exceeding 13sqcm in section complete all as specified and as directed
47M&L for 2nd class hardwood fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 13sqcm and not exceeding 25sqcm in section complete all as specified and as directed
48M&L for 2nd class hardwood fillets square, rectangular or tringular in section wrought screwed with nails exceeding 6sqcm and not exceeding 13sqcm in section complete all as specified and as directed
49M&L for 2nd class hardwood fillets square, rectangular or tringular in section wrought screwed with nails exceeding 13sqcm and not exceeding 25sqcm in section complete all as specified and as directed
50M&L for 2nd class hard wood plain fillets, square, rectangular and triangular in section, wrought, bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exceeding 6sqcm but not exceeding 13sqcm complete all as specified and as directed
51S&F 4mm thick asbestos cement plain building boards, fixed to timber framework with screws complete all as specified and as directed
52S&F in repairs wire netting of galvanized steel wire 0.71mm dia and 12mm mesh fixed with tinned tacks of wire complete all as specified and as directed
53S&F 6mm thick asbestos cement corrugated / semi-corrugated sheets in roof / walls fixed with "L" or "J" hooks or cranked hook bolts, and bituminous washers, etc. and joints suitably sealed, complete all as specified and as directed
54S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
55S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
56S&F 0.63mm thick corrugated galvanised steel sheetings, with grade of zinc coating 275gm/sqm and with two corrugation side lap fixed with‘L’ type or ‘J’ type cranked hook bolts, nuts, washers, etc. as in roof, wall, etc. complete all as specified and as directed
57--ditto-- all as per item No. 56 hereinabove but except sheets
58S&F 0.63mm thick corrugated galvanised steel sheetings, with grade of zinc coating 275gm/sqm, plain, fixed with cranked hook bolts, nuts, washers, etc. as in ridges, hips, valley gutters, drip and straight flashings (length or girth as fixed) complete all as specified and as directed
59--ditto-- all as per item No. 58 hereinabove but except sheets
60S&F 0.63mm thick plain plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed
61M&L for preparation of new masonry / concrete ceiling surfaces and applying three coats of white wash including all necessary staging, etc. as required complete all as specified and as directed
62M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
63M&L for preparing of new plastered or unplastered surfaces of walls and applying two coats of cement based paint (of approved tint) over a coat of wall primer complete all as specified and as directed
64M&L for cleaning and applying one coat of cold bituminous primer (as approved by GE) @0.25litre/sqm over dried up surfaces of concrete / plastered surfaces conforming to IS 3384-1986 complete all as specified and as directed
65Supply and laying APP based polymeric membrane 3mm thick (minimum), weighting not less than 3.5 kg/sqm reinforced with polyester non woven fabric (weighting not less than 160gms/sqm) applied over primed surfaces by torching application as per manufacturer"s instructions with overlaps minium 100mm on the transverse directions and 75mm in longitudinal directions complete all as specified and as directed
66M&L for repairing of damaged RCC chajja, fascia, fins, roof projections, ceiling and balcony railings, etc. at any height by rendering 10 to 30mm thick in one or two layers as per site requirements in CM 1:3 including mixing with liquid polymer (mixed as per manufacturer"s instructions) and making surfaces even and smooth without using extra cement includin all necessary scaffolding, staging, etc. as required complete all as specified and as directed
67M&L for preparation of new plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed
68M&L for preparation of complete removal of existing treatment and preparing plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of rapproved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed
69M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure non-asbestos fiber cement decorative board (E-Board Classic) in grid of GI system duly suspended from 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from roof with adjustment clips, providing positions for light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detectors, etc., cnforming to IS 14862, the main runners duly secured to structural soffits by hanger @1220mm c/c (maximum) with the last hanger at the end of each main runner not interlocked between main runners @610mm c/c so as to form 600x600mm grid complete all as specified and as directed
70Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm in girth complete all as specified and as directed
71S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores:
7215mm bore
7320mm bore
7425mm bore
75Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling herein before will be reused under this item
7615mm bore
7720mm bore
7825mm bore
79S&F in repairs gun metal globe or gate valve, 20mm dia, with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed
80S&F in repairs gun metal globe or gate valve, 25mm dia, with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed
81S&F in repairs 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
82S&F 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
83S&F in repairs 25mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
84S&F 25mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
85M&L for cleaning of internal surfaces of PVC overhead water tank including staging to a height required, etc. by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / siltinside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed of the following sizes:
86500litres
871000litres
882000litres
89Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed of the following capacities:
90500litres
911000litres
922000litres
93S&F PVC lids including PVC hinges and suitable PVC locking (both sides) to water tanks at any height or location / position complete all as specified and as directed suitable for the following capacities of water tanks:
94500litres
951000litres
962000litres
97S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
98S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
99S&F 110mm bore PVC (SWR) bend of any radius complete all as specified and as directed
100S&F 75mm bore PVC (SWR) bend of any radius with oval access door complete all as specified and as directed
101S&F 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed
102S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with or without door access complete all as specified and as directed
103S&F PVC (SWR) reducers any radius 110mm bore complete all as specified and as directed
104S&F PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified as directed