Tender For Construction Of Art And Cultural Center At Village Naikansol In Panchyat Balijudi Under Block Gudabandaha East Singhbhum, jamshedpur-Jharkhand

Rural Development Department has published Tender For Construction Of Art And Cultural Center At Village Naikansol In Panchyat Balijudi Under Block Gudabandaha East Singhbhum. Submission Date for this Tender is 13-05-2023. Building Work Tenders in jamshedpur Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

37523406
Tender For Construction Of Art And Cultural Center At Village Naikansol In Panchyat Balijudi Under Block Gudabandaha East Singhbhum
Open Tender
Indian
Jharkhand
jamshedpur
13-05-2023

Tender Details

Construction Of Art And Cultural Center At Village Naikansol In Panchyat Balijudi Under Block Gudabandaha East Singhbhum

Key Value

Document Fees
INR 10000 /-
EMD
INR 153000.0 /-
Tender Value
INR 76.09 Lakhs /-

BOQ Items

Name of Work: CONSTRUCTION OF ART AND CULTURAL CENTER AT VILLAGE NAIKANSOL IN PANCHYAT BALIJUDI UNDER BLOCK GUDABANDAHA EAST SINGHBHUM
Sl. No. Item Description
1Earthwork in excavation in foundation trenches in ordinary soil(videclassificationofsoilitem-A0anddisposalof excavated earth as obtained to a distance upto 50M includingallliftslevelling,rammingthefoundation trenches,removingrootsoftrees,shurbsallcompleteas per approved design, building specification and direction of E/I.
2Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
3Providing coarse clean Sand in Filling in foundation trenches orinplinthincludingrammingandwateringinlayersnot exceeding150mmthickwithallleadsandliftsincluding cost of all materials, labour, royalty and taxes all complete as per building specificationand direction of E/I. (Mode of measurement compacted volume).
4Providing designation75Bone brick flat soling joints fitted withlocalsandincludingcostofwateringtaxesroyaltyall complete as per building specification and direction of E/I.
5Providing and laying in position cement concrete of specifiedgradeexcludingthecost ofcenteringand shuttering - All work up to plinth level :
61:4:8(1 Cement : 4coarse sand (zone-III) : 8gradedstone aggregate 40 mm nominal size)
71:2:4(1 Cement : 2coarse sand (zone-III) : 4gradedstone aggregate 40 mm nominal size)
8Providingandlayinginpositionspecifiedgradeof reinforcedcementconcrete,excludingthecostof centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3(1cement:1.5coarsesand(zone-III):3graded stone aggregate 20 mm nominal size) Foundation
9Reinforcedcementconcreteworkinwalls(anythickness), includingattachedpilasters,buttresses,plinthandstring courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost ofcentering, shuttering,finishing andreinforcement :
10Reinforcedcementconcreteworkinbeams,suspended floors,roofshavingslopeupto15°landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases andspiralstaircasesaboveplinthleveluptofloorfive level,excludingthecostofcentering,shuttering,finishing and reinforcementwith 1:1.5:3(1 cement:1.5coarse sand(zone-III):3gradedstoneaggregate20mmnominal size). Beam
11Providing Toe steel reinforcement of 8mm dia rods as approved
12ProvidingToesteelreinforcementof10mmdiarodsas approved
13Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved
14Centeringandshutteringincludingstrutting,proppingetc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
15Columns, Pillars, Piers, Abutments, Posts and Struts
16Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Suspended floors, roofs, landings, balconies and access platform
18Providingandfixingcircular/HexagonalcastironorM.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, toplid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia roundheadedscrews, one lock at the corners. Clamp shall bemadeof12mmdiaM.S.barbenttoshapeasper standard drawing.
19Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and liftof1.5Mallcompleteasperbuildingspecificationand directionofE/I.(Modeofmeasurementcompacted volume)
20Providing designation 75A brick work in C.M. (1:6) in foundationandplinthapprovedqualityofcleancoarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
21Providing25mmthickDampProofCoursewithcement concreteM-200withnominalmixof(1:1.5:3)with approvedqualityofstonechipsof20mmto6mmsize gradedandcleancoursesandofF.M.2.5to3including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compoundandplacinginposition,striking,curing,taxes androyaltyallcompleteasperbuildingspecificationand direction of E/I.
22Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
23Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
24Providing6mmthickcementplaster(1:4)inceilingwith cleanofF.M. 1.5includingscreening,curingwithallleads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
25Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leadsandliftsofwater,scaffoldingtaxesandroyaltyall complete as per building specification and direction of E/I.
26Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.
27ProvidingandlayingrectifiedGlazedCeramicfloortilesof size 300x300 mm or more (thickness to be specified by the manufacturer),of1stqualityconformingtoIS:15622,of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar1:4(1Cement:4Coarsesand),jointingwithgrey cementslurry@3.3kg/sqmincludingpointingthejoints with white cement and matching pigments etc., complete.
28Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour
29Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with coat of neat cement in skirting including rounding of junctions with floor, curing, taxes royalty all complete as per building specification and direction of E/I
30Supplying, fitting and fixing 20 M.S. Grill made of size 20 x 6mm MS flat as per approved design and drawing, properly fabricatedwithjointscontinousfilletweldedandfinished smooth, carriage of grills towork site, hoisting as per building specification and direction of E/I.
31Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
32Providingandfixingglazinginaluminiumdoor,window, ventilator shuttersandpartitionsetc.withEPDMrubber/neoprene gasket etc.completeasperthearchitecturaldrawingsandthe directions ofEngineer-in-charge.(Costofaluminiumsnapbeading shall be paid in basic item): With float glass panels of 4.00 mm thickness
33Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works
34Providingprimeronecoatofredleadpaintofapproved make over new steel surface including preparing the surfaceaftercleaning,removingdust,dirt,scalessmokes andgreaseandcleaningthesurfacethoroughlyincluding costofscaffoldingandtaxesallcompleteasperbuilding specificationanddirectionofE/I.(Modeofmeasurement Areashallbemultipliedbytheco-efficientasindicatedin building specificatio).
35Providing two coats of synthetic enamel paint of apporoved shadeandmakeoversteelsurfacethoroughlyscaffolding andtaxesallcompleteasperbuildingspecificationand direction of E/I.
36Water proofing for Old and Now Roof Slab • Providing and layingwaterproofingtreatmentonroofslabbyapplying twoComponent,factorydesigned,readytouse,acrylic modified flexible material applied wth brush, roller or spray for water proofing coating as Per Mier specificatIons with followingsteps(a)surfacepreparation-Providingand cleaningo1concrete...leceleremovedust, oil,grease includingremovalofexistingloosepaintrcoating,and cement laitance bycleaning with comer..ed air 8 water let including all materials, labour, tools complete Ponding test tobedoneafterpluggingalloutletsandtobe checkedtrodentify seepage eakage On identification of seeps cem t be done with non shrink expanding admixt e a Ind,t1MYKcg/DrFout/Fosrocorequiveteemssuchas thosebetwebechamferedwith15141admixedwithac Fixit or equivalent slum, of acrylic concretein baserovtartg and repaving of all c arapet wall and the roof slab et 50 mm filletofmortar(CementsandmerofSika/Fosroc/MYK SchomberglDr chamfering a prime coat shall be given with theRepairingsurfaceirregularities,damagedadcracksif any, withanacrylic polymer modifiedrepair moile, including a coat of bonding agent of the same with cement slurryinctC01;allmaterial,labour,toolscomplete(b)1st Coat-APOrlitcoatoftwocomponentacrylicmodified, ready to use. flexible come s material on surface saturated
37CoveringoftreatedsurfacewithPCC.-Providing25mm thickCementAlf,ConcreteM201:1.:3)maintainingslope in alternate 2 mt x 2 mt panels with aaprove. of stone chips of20mmto6mmsizegradedandcleanedsand 2.5to 3 including screening,shuttering,and mixing cement concret . fixer with admixture of integral water proofing and placing inposi.ingcuring,taxesandroyalityallcompleteasper building specifi nd direction of Ell. Panels that has been left shoul be casted next dysThere should be 6 mm gap betweenPanels.BrandSika_PlastocrateAus,MYKproof WP10, Fosroc- Conplast X421 lc& Dr Fixit Pidiproof LW+
38Providing and filling of 6 mm thick Groove between 25 mm PCC PanelswithPolysulphideSealant (PoringGrade)as Per drawingsandtechnicalspecificationsanddirectionofEin Charge(with18%GSTPolysulphicleFosroc-Thoflex600.Dr Fixit Pidiseal PS(42P) !MraYndK -Seikaal PS or Euivalent
39Providing and fixing on wall face unplasticised - PVC mouldedfittings/accessoriesforunplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointingwithsealringconformingtoIS:5382,leaving10 mm gap for thermal expansion.
40Bend 87.5° 110 mm bend
41Shoe (Plain) 110 mm Shoe
42Providing150mmwidebrickdrainincementmortar(1:6) withav.150mmcleardepthand125mmapronincluding costofearthworkinvolvedwith75mmcementconcrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
43Makingplinthprotection50mmthickofcementconcrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidatedandgroutedwithfinesand,including necessaryexcavation,levelling&dressing&finishingthe top smooth.
44Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge
45Providing12mmcementplaster(1:3)withcleancoarsesandof F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
46Providing1.5mmcementpunningincludingcuring,carriageof waterwithallleadsandliftsasperbuildingspecificationand direction of E/I.
47Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brickhoneycombshaftwithbricksandS.W.drainpipe100mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
48CARRIAGE OF MATERIAL
49CEMENT (10 KM)
50SAND (25 KM)
51CHIPS (60KM)
52BRICK (10 KM)
53STEEL (10 KM)
54Supplying,fittingandfixingviterouswhiteglazedearthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved makewith100mmH.C.I., "p"trap15litresC.I.. orC.pull and let go flushing cistern of names or other I.S.S. equivalentmake,completewithall fittings,C.I. orC.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about2MlongwithonebrasscouplingandclampsG.I. chain and pull including supplying and fixing a pair of viterouswhiteglazedearthenwarewherefootresttobe fixedinfloor15mmC.I.bodybrassspindlestopcockof weightnotlessthan50grms.15mmP.V.C.connection pipe450mmlongandtheexposedpipeandcisternwith two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 580mm. long - with 10 litre low level PVC cistern
55Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 : 15 mm nominal bore
56Providing and fixing PTMT Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, Weighing not less then 106 gms.
57ProvidingandfixingC.P.brassanglevalveforbasinmixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
58Providing and fixing C.P. extentsion Nipples 15mm size with 12”BSPthreads,70mmlengthand30mmbredthand weight not less than 18gms
59ProvidingandfixingwashbasinwithC.I.brackets,15mm C.P.brasspillartaps,32mmC.P.brasswasteofstandard pattern,includingpaintingoffittingsandbrackets,cutting andmakinggoodthewallswhereverrequire:Faltback wash basin size 630X450 mm with a single 15mm C. P. pillar tap.
60Providing andfixing PTMTgratingof approvedquality and colour. 125 mm nominal dia with 25 mm waste hole
61ProvidingandfixingunplasticisedP.V.C.connectionpipe withPTMTNuts,collarandbushofapprovedqualityand colour. 15 mm nominal bore with 45 cm length
62ProvidingAndfixing32mmwastepipeforsinkorwash basin including P.V.C. waste fittings complete.
63ProvidingandfixingChlorinatedPolyvinylChloride(CPVC) pipes, having thermal stability for hot & coldwater supply including all CPVCplain&brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the wall etc. 15mm dia
64ProvidingandfixingChlorinatedPolyvinylChloride(CPVC) pipes, having thermal stability for hot & coldwater supply including all CPVC plain & brass threaded fittings This includesjointingofpipes&fittingswithonestepCPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
6525mm dia
6632 mm dia.
6740mm dia
68Supllyingandmatarialswithlobourforconstruction inspectionchamberofdesignationclass75bbrickdeep 600x450 internal diamention having 250mm wall thickness in cementmorter(1:6)including 12mm cement plaster (1:4)withpunningoninsideandcementplaster(1:6)with 600x450mmG.I.coverwithframe(weightnotlessthan 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
69ProvidingandfixingC.P.brassStopCock(concealed)of standarddesignandofapprovedmakeconformingtoIS 8931 15mm nominal bore, approved brand C.P. fittings.
70Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri ) with cover & locking system
71Providing and fixing PTMT towel rail trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approvedqualityandcolour,weighingnotlessthan88 gms.
72Providingandfixingc.p.towelringcomplitewith brackets fixedtowoodencleatswithc.p.brassscrewswith concealedfittingarangementofapprovedqualitecolour and make.
73ProvidingandfixingPTMT/C.P.swivellingshower,15mm nominalsize,95mmlong,65mmdia.ofapprovedquality, color & make weighing not less than 40 gms with approximate 80 holes of 1.2 mm dia.
74provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.
75provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.
76Point wiringinPVCconduit,with piano type switch - Wiringforlight point/exhaustfanpoint/callbellpoint with 1.5 sq.mm.FRPVCinsulated copperconductorsinglecorecablein surface/recessedPVCconduit,with pianotypeswitch,phenoliclaminated sheet,suitablesizePVC/G.I.boxetc. as required Group A Gr-A
77S/F light plug point with piano type accessories- Supplyingandfixing suitable size G.I./PVCboxonsurface or inrecesswithphenolicliminatedsheet coverinfrontincludingprovidingand fixing 5 pin, 5/6 amps socket outlet and 5/6 amps piano tyep switch connection, painting etc. as required.
78S/Fpowerplugpointwithpianotype accessories- Supplyingandfixing suitable size G.I./PVCboxonsurface or inrecesswithphenolicliminatedsheet coverinfrontincludingprovidingand fixing6pin,15/16ampssocketoutlet and 15/16 amps piano type switch connection, painting etc. as requird.
79Power plug wiring in PVC conduit (2 x 4 sq.mm)- Wiringforlight/powerplug with2 x4 sq.mm.FR PVC insulated copperconductorsinglecorecablefor loop earthing as required.
80Circuit/submain wiringin PVCconduit - WiringforCircuit/submain wiringalong withearthwirethefollowingsizes PVC insulatedcopperconductor,singlecore cableinsurface/recessedPVCconduit as required.
812x1.5sq.mm.+1x1.5sq.mm.Earth wire
822x2.5sq.mm.+1x2.5sq.mm.Earth wire
832 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire
844x6.0sq.mm.+2x6.0sq.mm.Earth wire
85Wiringinexistingconduit-Supplying anddrawingfollowingsizesofFRPVC insulatedcopperconductor,singlecore cable inthe existing surface/recessed steel/PVC conduit as required. 2 x 4 sq.mm.
86S/FfourpoleMCBisolator- Supplying andfixingfollowingrating,fourpole, 415volts,isolatorintheexistingMCB DBcompletewithconnections,testing and commissioining etc. as required
8740 amps
8880/100 amps
89S/FS.P.MCB DB- Supplyingand fixing following way single pole netural, sheet, MCBdistributionboard,240volts,on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powderpaintedincludingearthingetc. as required (Butwithout MCB/RCCB/Isolator) 8 way, double door
90S/FT.P.MCB DB- Supplyingand fixing followingway,threepoleandnetural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powderpaintedincludingearthingetc. as required. (But without MCB/RCCB/Isolator)
914 way (4 + 12), Double door, Horizontal type
926 way (4 + 18), Double door, Horizontal type
93S/F "C" series, MCB -Supplying and fixing following 240 volts, "C" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection,testingandcommossioning etc. as required.
946/32 amps, Single Pole
9540 amps, TPN
9640 amps, DP
9750/63 amps, DP
98S/F ceiling rose -Supplying and fixing 2 pin5ampceilingroseontheexisting junction box/wooden block including connection etc. as required.
99ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compactfluorescent fittingofall type,completewithallaccessoriesand tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.
100ITC Fluorescent fitting with down rods - Installation,testingandcommissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete withallaccessoriesandtubeetc. includingsupplyingandfixingballand socket arrangement, 2 no. down rods of 20mm dia stee.
101S/Fpianotypeswitch/socket- Supplying and fixing following piano tyepswitch/socketontheexisting switchbox/coverincludingconnections etc. as required.
1025/6 amps, one way switch
1033 pin 5/6 amps, socket outlet
104S/F PVC /G.I. boxes -Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenoliclaminatedsheetcoverinfront including painting etc. as required. 75mm x 75mm x 50mm deep/(4" x 4")
105ITCexhaustfanupto450mmsweep- Installation of exhaust fan upto 450mm sweep in the existing opening, including makingtheholetosuitthesizeofthe abovefan,makinggoodthedamage, connection,testingcommissioningetc. as required.
106S/FPVCconduit- Supplyingandfixing of following sizes PVC conduit along with accessories in surface/recess includingcuttingthewallandmaking good the same in case recessed conduit as required. 20mm
107S/F Batten holder -Supplying and fixing batten/angle holderincluding connection etc. as required.
108Copper earth plate elecrtode -Earthing with copper earth plate 600mmx 600mmx3mmthickincluding accessoriesandprovidingmasonary enclosurewithcoverplatehaving lockingarrangementandwateringpipe etc.asrequired(Butwithcharcoalor coke and salt)
109S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at0.50metrebelowgroundlevelfor conductor earth, including soldering etc. as required
110P/FGIlightningconductorfinal- Providing and fixing of GIlightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copperbaseplatebaseincludingholes etc. complete as required.
111P/F G.I. lightning conductor tape in horizontal run -Providing and fixing G.I. tape20mmx3mmthickonparapet or surfaceofwallforlightningconductor complete as required. (For horizontal run)
112P/F G.I. lightning conductor tape in verticalrun- ProvdingandfixingG.I. tape20mmx3mmthickonparapet or surfaceofwallforlightningconductor complete as required. (For vertical run)
113MV Cable :-Supply ofISI marked aluminium cable conductor XLPE PVC Insulated Cable as per I.S :7098 armoured , served shaelthed 1100V gradewithTerminationandlayingof cable . Make :- Finolex , Polycab , Havells , Universal - 50 sqmm X 3.5 Core armoured AL Cable for JSEB supply
114Supplyingandmakingendtermination withbrasscompressionglandand aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminiumconductorcableof1.1KV grade as required. 3½ X 50 sq. mm (35mm)
115MV cable laying upto 120 sq.mm. in ground without sand and cover -Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
116Supply of Exhaust Fan :- Supply and fitting of 230mm, 230V AC metal exhaust fan in the existing opening including making good the damage, connectiontestingcommisioningetcas required
117Led bulb 9W/10W :- Supplying and fixing ofLED9W/10W bulband acessoriesasrequired.
118Supplyofceilingfan:-Supplyingand fitting of 1400mm sweep regular/standared model AC fan, including connectionwith1.5sqmmcopperwire downrodofstanderedlength(upto 30cm)withallacessoriesasrequired
119Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
120(a) From 0.00 M to 50.00 M below G.L.
121(b) From 51.0 M to 100.00 M
122Supplying, assembling, lowering and fixing in vertical position in borewell,unplasticizedPVCmediumwellcasing(CM)pipeof required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
123Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
124Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
125Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
126Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
127FR PVC Insulated 3 Core 4 Sqmm copper wire
128GI Pipes ( Tata Mark or Equivalent ) as per IS -1239 ( Part -01) 2004 ISI Marked / Medium Quality 40 mm dia
129GST - 18%
130Labour Cess - @ 1%