}

Design Supply Installation Testing Commissioning Of Intelligent Analogue Addressable Fire Alarm System-Multi State

Reserve Bank Of India has published Design Supply Installation Testing Commissioning Of Intelligent Analogue Addressable Fire Alarm System. Submission Date for this Tender is 17-05-2023. Alarm Systems Tenders in Multi State. Bidders can get complete Tender details and download the document.




Tender Notice

37510019
Design Supply Installation Testing Commissioning Of Intelligent Analogue Addressable Fire Alarm System
Tender
Indian
Multi State
17-05-2023

Tender Details

Design Supply Installation Testing Commissioning Of Intelligent Analogue Addressable Fire Alarm System Of Microprocessor Based 03 Loops, Networkable Analogue Addressable Facp. The Panel Shall Have Minimum 640-Character Lcd / Led Display Or Touchscreen. Each Loop Shall Have A Capacity Of Minimum 250 Analog Addressable Detectors / Devices. It Shall Have Multi Access Levels, Flash Eprom And Should Be Operated On 240 Volts Ac Power Supply, ( Ups Supply Will Be Given By The Bank ) . Automatic Battery Charger, 24 Volts Sealed Lead Acid Batteries Sufficient For 60 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During An Emergency Condition. Fire Alarm Control Panel Shall Also Be Supplied With All The Required Gateways Like Modbus Bacnet, Etc., And The Required Hardware, Software, Application Program Interface ( Api ) , Sdk, Etc., To Communicate On Open Protocol Such As Modbus / Bacnet Etc. For Connectivity With The Command And Control Centre. Cost Of Fas Panel Shall Include All The Loop Cards, Interface Cards, Control Cards, Power Control Cards, Etc. 2 2 Sitc Of Networked Graphic Software Sitc Of The Networked Graphic Software / Ncs For Control And Monitoring Of The Fire Alarm Network. Fire Graphic Software With Real-Time Fire System Status And System Control Options. The Software Shall Interface Directly To The Fire System Network Gateway. Fire Graphic Software Must Be Capable Of Graphically Representing Each Facility Being Monitored With Floor Plans And Icons Depicting The Actual Locations Of Various Systems And / Or Sensors? Locations. ( A ) Supply Of Computer / Workstation / Pc With Intel� I3 ( 11 Gen ) - 2.0 Ghz, 8Gb Ram, 512 Gb, Sdd Hard Disk, Dvd-Rom / Cdrw, Sound Card, Mouse, Speakers, Keyboard, Ethernet Card, Pci Slot, Rs-232 Serial Com Port, Windows Os, Laser Jet Printer And 32 Flat Screen Led Monitor ( B ) Cost Shall Include All Programming Charges, Interface Modules With Other Fire Alarm System And Its Components, Bms System, Etc. ( C ) It Shall Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender. 3 3 Sitc Of Repeater Panel Supply, Installation, Testing And Commissioning Of Repeater Panel Complete With Minimum Suitable Display Or Touchscreen To Indicate The Status Of System And Location Of Incident, Etc., Back-Box And Control Function. It Shall Be Ul / En 54 Listed And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender 4 4 Sitc Of Iaa Floating Sensitivity Type Multi Sensor Detector Below False Ceiling Multi Sensor Detector Below False Ceiling: Supply, Installation, Testing And Commissioning ( Sitc ) Of Intelligent Analogue Addressable, Floating Sensitivity Type Multi Sensor Detector Below False Ceiling ( Photo + Fixed Temp. + Rate Of Rise Temp. ) With Base For Use As Heat Or Smoke Or Combined Both, Electronic Addressable, Microprocessor Type With Operating Temperature From -20 C To + 60 C. Detector Shall Have Auto Learn, Drift Compensation, Etc. It Shall Be Ul / En 54 Approved And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender. Works Include Providing Mounting Boxes, Flash Leds, Addressable Switches To Program, Complete As Required For Below False Ceiling. 5 5 Sitc Of Iaa Floating Sensitivity Type Multi Sensor Detector Above False Ceiling Multi Sensor Detector Above False Ceiling: Supply, Installation, Testing And Commissioning ( Sitc ) Of Intelligent Analogue Addressable, Floating Sensitivity Type Multi Sensor Detector Above False Ceiling, I.E., In The True Ceiling ( Photo + Fixed Tempt. + Rate Of Rise Tempt. ) With Base For Use As Heat Or Smoke Or Combined Both, Electronic Addressable, Microprocessor Type With Operating Temperature From -20 C To + 60 C. Detector Shall Have Auto Learn, Drift Compensation, Etc. It Shall Be Ul / En 54 Approved And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender. Works Include Providing Mounting Boxes, Flash Leds, Addressable Switches To Program, Complete As Required For Above False Ceiling / True Ceiling, Etc. 6 6 Sitc Of Analog Addressable Rate Of Rise Cum Fixed Temperature Detector Supply, Installation, Testing And Commissioning Of Analog Addressable Rate Of Rise Cum Fixed Temperature Detector With Mounting Base, Led, Addressable Switch To Programme The Detectors Complete As Required Below False Ceiling / True Ceiling. It Shall Be Ul / En 54 Approved And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender. Works Include Providing Mounting Boxes, Mounting Box Leds, Addressable Switch To Program, Complete As Required For Above False Ceiling / True Ceiling, Etc. 7 7 Sitc Of Addressable Dual Action Manual Call Station Supply, Installation, Testing And Commissioning Of Addressable Dual Action Manual Call Station. Cost Of All The Accessories Required For Fixing Of Detectors On Concrete Wall / Wall Panels, Termination Of Cable, Required Back Boxes, Required Modules At Fas Panels, Required Accessories, Etc., Complete Have To Be Included In The Rate Quoted And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender 8 8 Sitc Of Addressable Hooter Cum Strobe Lights Supply, Installation, Testing And Commissioning Of Addressable Hooter Cum Strobe Lights With 110 Cd Complete With Modules. Cost Of All The Accessories Including Back Boxes, Required Modules At Fas Panels, Etc., Required For Fixing Of Hooter On Concrete Roof / False Ceiling, Termination Of Cable, Required Accessories, Etc., Complete Have To Be Included In The Rate Quoted And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender. 9 9 Sitc Of Response Indicator ( Ri ) Supply, Installation, Testing And Commissioning Of Response Indicator ( Ri ) With Dual Leds. Cost Of All The Accessories Required Like Boxes, Back Plate, For Fixing Of Ri On Concrete Roof / False Ceiling Termination Of Cable, Etc., Required Accessories, Etc., Complete Have To Be Included In The Rate Quoted And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender . 10 10 Sitc Of Addressable Control Modules For Ahus Modules: Addressable Relay Modules: Supply, Installation, Testing And Commissioning Of Addressable Control Modules For Ahus And Control Dampers, Lift System, Etc., Cost Must Include All The Accessories, Control / Monitor / Interface Cards, Interoperability Relays, Control Relays, Contactors, Etc., In Complete Operable Condition And Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender 11 11 Supply And Laying Of 2 X 1.5 Sq.Mm Armoured Red Coloured Frls Supply And Laying Of 2 X 1.5 Sq.Mm Armoured Red Coloured Frls Strandard Copper Conductor Cable For Fire Alarm Loop ( A Type ) , Etc., On Ceiling / Walls / Trays Including Concealed Drops With All Accessories Hardware, ( E.G., Clamps, Lugs, Cable Numbering Plates, Saddles, Spacers, Glands, Etc. ) And Fixing Materials And As Directed By The Bank?S Engineer And As Per The Site Requirements. Further, It Shall Comply Fully With The Detailed Specifications Set Out In Part I Of The Tender. 12 12 Supply And Laying Of 2 X 1.5 Sq.Mm Armoured Red Coloured Frls Same As Item No 11, But In Underground Manner By Excavation At Minimum Three Feet Below Soil, Providing 2 Inch ( 50 Mm ) Gi B Class Pipe, Connectors, L Bend, Couplers, Etc., And Other Required Accessories Shall Be Included.. 13 13 Rebate For Dismantling And Taking Away Old Fire Alarm System ( Bosch Make ) Rebate For Dismantling And Taking Away Old Fire Alarm System ( Bosch Make ) Including Detectors, Main Panel, Repeater Panels, Hooters, Mcps, Etc., Excluding Fire Alarm Cables After Commissioning And Stabilization Of New Fire Alarm System. 14 14 Comprehensive Annual Maintenance Service ( Camc ) Charges Comprehensive Annual Maintenance Service ( Camc ) Charges For The Entire Fire Alarm System Including Main Panel, Devices And Cabling, Spares, Labour, Upgradation Of Software, Etc. The Rate Shall Be Valid For First Year After Initial Guarantee Period Of One Year.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail