| 1 | 11 KVFEEDER RELACEMENT WITH 99 SQMM COVERED CONDUCTOR |
| 2 | 11.0 Mtr. Long Steel Lattice Structure with (65 x 65 x 6 mm) M.S. angle suitable for Covered 99sqmm Conductor including all nuts & bolts complete without arms. |
| 3 | 11 KV Class Polymeric Pin Insulator for covered conductor with GI Pin, Nuts & Bolts |
| 4 | Metallic Ties (Top / Side) for 11 KV Class Polymeric Insulator |
| 5 | 11 KV Polymeric Tension Insulator, 70 KN with Clamps, Nuts & Bolts |
| 6 | 11 KV Class Polymeric Tension Hardware with Clamps, Nuts & Bolts |
| 7 | Insulating Piercing Connector |
| 8 | \"T\" joint tap off with Busbar |
| 9 | NDS-Silicon / Surge Arrestor |
| 10 | 11 KV Tension Mid Span Jointing Kit for Covered Conductor |
| 11 | 11 KV Termination Kit for Covered Conductor |
| 12 | Covered conductor 99 Sq. mm. |
| 13 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 14 | PG Clamp for 99sqmm Conductor |
| 15 | M.S.channel 75X40X6mmX2.2 m long for DP. |
| 16 | Back clamps of 75x8mm M.S. flat for holdingchannel. |
| 17 | M.S. nuts & bolts of 16mm dia.X 40mm length. |
| 18 | M.S. channel 75X 40X 6mm 1.8 m long for S.P.structure. |
| 19 | Pole top channel 75X40X 6mmX0.3m long S.P. structure. |
| 20 | Structure Earthing: 25x3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination etc. |
| 21 | Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate |
| 22 | Red oxide paint @ 2 ltr/ pole |
| 23 | Aluminium paint @ 1.5 ltr / pole |
| 24 | G.I. Barbed Wire |
| 25 | 11 kV Caution Board |
| 26 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 27 | 11 KVFEEDER RELACEMENT WITH 70 SQMM COVERED CONDUCTOR |
| 28 | 11.0 Mtr. Long Steel Lattice Structure with (65 x 65 x 6 mm) M.S. angle suitable for Covered 70 sqmmConductor including all nuts & bolts complete without arms. |
| 29 | 11 KV Class Polymeric Pin Insulator for covered conductor with GI Pin, Nuts & Bolts |
| 30 | Metallic Ties (Top / Side) for 11 KV Class Polymeric Insulator |
| 31 | 11 KV Polymeric Tension Insulator, 70 KN with Clamps, Nuts & Bolts |
| 32 | 11 KV Class Polymeric Tension Hardware with Clamps, Nuts & Bolts |
| 33 | Insulating Piercing Connector |
| 34 | \"T\" joint tap off with Busbar |
| 35 | NDS-Silicon / Surge Arrestor |
| 36 | 11 KV Tension Mid Span Jointing Kit for Covered Conductor |
| 37 | 11 KV Termination Kit for Covered Conductor |
| 38 | Covered conductor 70 Sq. mm. |
| 39 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 40 | PG Clamp for 70 sqmm Conductor |
| 41 | M.S.channel 75X40X6mmX2.2 m long for DP. |
| 42 | Back clamps of 75x8mm M.S. flat for holdingchannel. |
| 43 | M.S. nuts & bolts of 16mm dia.X 40mm length. |
| 44 | M.S. channel 75X 40X 6mm 1.8 m long for S.P.structure. |
| 45 | Pole top channel 75X40X 6mmX0.3m long S.P. structure. |
| 46 | Structure Earthing: 25x3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination etc. |
| 47 | Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate |
| 48 | Red oxide paint @ 2 ltr/ pole |
| 49 | Aluminium paint @ 1.5 ltr / pole |
| 50 | G.I. Barbed Wire |
| 51 | 11 kV Caution Board |
| 52 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 53 | 11 KVFEEDER RELACEMENT WITH 50 SQMM COVERED CONDUCTOR |
| 54 | 11.0 Mtr. Long Steel Lattice Structure with (65 x 65 x 6 mm) M.S. angle suitable for Covered 50 sqmm Conductor including all nuts & bolts complete without arms. |
| 55 | 11 KV Class Polymeric Pin Insulator for covered conductor with GI Pin, Nuts & Bolts |
| 56 | Metallic Ties (Top / Side) for 11 KV Class Polymeric Insulator |
| 57 | 11 KV Polymeric Tension Insulator, 70 KN with Clamps, Nuts & Bolts |
| 58 | 11 KV Class Polymeric Tension Hardware with Clamps, Nuts & Bolts |
| 59 | Insulating Piercing Connector |
| 60 | \"T\" joint tap off with Busbar |
| 61 | NDS-Silicon / Surge Arrestor |
| 62 | 11 KV Tension Mid Span Jointing Kit for Covered Conductor |
| 63 | 11 KV Termination Kit for Covered Conductor |
| 64 | Covered conductor 50 Sq. mm. |
| 65 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 66 | PG Clamp for 50sqmm Conductor |
| 67 | M.S.channel 75X40X6mmX2.2 m long for DP. |
| 68 | Back clamps of 75x8mm M.S. flat for holdingchannel. |
| 69 | M.S. nuts & bolts of 16mm dia.X 40mm length. |
| 70 | M.S. channel 75X 40X 6mm 1.8 m long for S.P.structure. |
| 71 | Pole top channel 75X40X 6mmX0.3m long S.P. structure. |
| 72 | Structure Earthing: 25x3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination etc. |
| 73 | Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate |
| 74 | Red oxide paint @ 2 ltr/ pole |
| 75 | Aluminium paint @ 1.5 ltr / pole |
| 76 | G.I. Barbed Wire |
| 77 | 11 kV Caution Board |
| 78 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 79 | LT Bare TO LT ABC (3X95+1X50+1X16)SQ.MM |
| 80 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 81 | Tension Clamp for Dead End for L.T A B Cable |
| 82 | Suspension Clamp for L.T A B Cable |
| 83 | Tension Clamp for Dead End with Attachment |
| 84 | Clamps for Neutral |
| 85 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 86 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 87 | LTAir Bunched Cable 3 x 95 Sqmm + 1 x 50 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 88 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 89 | Back Clamps 75 x 8 mm flat |
| 90 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 91 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 92 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 93 | Red Oxide Paint |
| 94 | Aluminium Paint |
| 95 | Anti Climbing Device (Barbed Wire) |
| 96 | 440 Volt Caution Board |
| 97 | LT Bare TO LT ABC(3X70+1X50+1X16)SQ.MM |
| 98 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 99 | Tension Clamp for Dead End for L.T A B Cable |
| 100 | Suspension Clamp for L.T A B Cable |
| 101 | Tension Clamp for Dead End with Attachment |
| 102 | Clamps for Neutral |
| 103 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 104 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 105 | LTAir Bunched Cable 3 x 70 Sqmm + 1 x 50 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 106 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 107 | Back Clamps 75 x 8 mm flat |
| 108 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 109 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 110 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 111 | Red Oxide Paint |
| 112 | Aluminium Paint |
| 113 | Anti Climbing Device (Barbed Wire) |
| 114 | 440 Volt Caution Board |
| 115 | LT Bare TO LT ABC(3X50+1X35+1X16)SQ.MM |
| 116 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 117 | Tension Clamp for Dead End for L.T A B Cable |
| 118 | Suspension Clamp for L.T A B Cable |
| 119 | Tension Clamp for Dead End with Attachment |
| 120 | Clamps for Neutral |
| 121 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 122 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 123 | LTAir Bunched Cable 3 x 50 Sqmm + 1 x 35 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 124 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 125 | Back Clamps 75 x 8 mm flat |
| 126 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 127 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 128 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 129 | Red Oxide Paint |
| 130 | Aluminium Paint |
| 131 | Anti Climbing Device (Barbed Wire) |
| 132 | 440 Volt Caution Board |
| 133 | LT BARE TO LT ABC(3X35+1X35+1X16)SQMM |
| 134 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 135 | Tension Clamp for Dead End for L.T A B Cable |
| 136 | Suspension Clamp for L.T A B Cable |
| 137 | Tension Clamp for Dead End with Attachment |
| 138 | Clamps for Neutral |
| 139 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 140 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 141 | LTAir Bunched Cable 3 x 35 Sqmm + 1 x 35 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 142 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 143 | Back Clamps 75 x 8 mm flat |
| 144 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 145 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 146 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 147 | Red Oxide Paint |
| 148 | Aluminium Paint |
| 149 | Anti Climbing Device (Barbed Wire) |
| 150 | 440 Volt Caution Board |
| 151 | LT BARE TO LT ABC(3X25+1X16)SQMM |
| 152 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 153 | Tension Clamp for Dead End for L.T A B Cable |
| 154 | Suspension Clamp for L.T A B Cable |
| 155 | Tension Clamp for Dead End with Attachment |
| 156 | Clamps for Neutral |
| 157 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 158 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 159 | LTAir Bunched Cable 3 x 25 Sqmm +1 x 16 sqmm insulated neutral cum Messenger |
| 160 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 161 | Back Clamps 75 x 8 mm flat |
| 162 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 163 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 164 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 165 | Red Oxide Paint |
| 166 | Aluminium Paint |
| 167 | Anti Climbing Device (Barbed Wire) |
| 168 | 440 Volt Caution Board |
| 169 | LT BARE TO LT BARE(3-PH 5 WIRE AAC ANT 50 SQMM) |
| 170 | 8.5 mtr. steel latticed structure of 35x35x6 mm complete with nuts & bolts. |
| 171 | LT shackle insulator 3\"x3 1/2\". |
| 172 | \"D\" clamp complete with pin, washers, nuts & bolts. |
| 173 | Guy assembly complete with 7/12 SWG GI stay wire, 110x75 mm LT guy insulator, 16mm dia stay rod,1.8 mtrs. long withbow thimble, turn buckle and 150x150x6mm |
| 174 | AAC ANTconductor 50 sq.mm. |
| 175 | No. 12 SWG G.Iwire for continuous earth wire |
| 176 | Safe Earthing model T-19 short current 20KA rms for 1 sec(LV / MV) application. 50 mm diameter x 3 Mtrs. Electrode & two bags backfill chemical compound. |
| 177 | Danger Board 440 Volts. |
| 178 | Painting of poles with Red Oxide paint @1.5 Ltr./pole. |
| 179 | Painting of poles with Aluminium paint @1 Ltr./pole. |
| 180 | G.I Barbed wire @ 2Kg/pole. |
| 181 | LT BARE TO LT BARE(1-PH 2 WIRE AAC GNAT 25 SQMM) |
| 182 | 8.5 mtr. steel latticed structure of 35x35x6 mm complete with nuts & bolts. |
| 183 | LT shackle insulator 3\"x3 1/2\". |
| 184 | D\" clamp complete with pin, washers, nuts & bolts. |
| 185 | Guy assembly complete with 7/12 SWG GI stay wire, 110x75 mm LT guy insulator, 16mm dia stay rod,1.8 mtrs. long withbow thimble, turn buckle and 150x150x6mm anchor plate. |
| 186 | AAC GNATconductor 25 sq.mm. |
| 187 | Safe Earthing model T-19 short current 20KA rms for 1 sec(LV / MV) application. 50 mm diameter x 3 Mtrs. Electrode & two bags backfill chemical compound. |
| 188 | Danger Board 440 Volts. |
| 189 | Painting of poles with Red Oxide paint @1.5 Ltr./pole. |
| 190 | Painting of poles with Aluminium paint @1 Ltr./pole. |
| 191 | G.I Barbed wire @ 2Kg/pole. |
| 192 | LT BARE TO LT BARE(3-PH 4 WIRE AAC GNAT 25 SQMM) |
| 193 | 8.5 mtr. steel latticed structure of 35x35x6 mm complete with nuts & bolts. |
| 194 | LT shackle insulator 3\"x3 1/2\". |
| 195 | D\" clamp complete with pin, washers, nuts & bolts. |
| 196 | Guy assembly complete with 7/12 SWG GI stay wire, 110x75 mm LT guy insulator, 16mm dia stay rod,1.8 mtrs. long withbow thimble, turn buckle and 150x150x6mm anchor plate. |
| 197 | AAC GNATconductor 25 sq.mm. |
| 198 | No. 12 SWG G.Iwire for continuous earth wire |
| 199 | Safe Earthing model T-19 short current 20KA rms for 1 sec(LV / MV) application. 50 mm diameter x 3 Mtrs. Electrode & two bags backfill chemical compound. |
| 200 | Danger Board 440 Volts. |
| 201 | Painting of poles with Red Oxide paint @1.5 Ltr./pole. |
| 202 | Painting of poles with Aluminium paint @1 Ltr./pole. |
| 203 | G.I Barbed wire @ 2Kg/pole. |