Tender For Internal Periodical Services And Repair To Flooring False Ceiling Plumbing Roof Treatment And Other Misc Works In Otm Accn Of Delhi Cantt Atc Esd And Fol Depot In Aor Of Age Br Ii Under Ge North Delhi Cantt 10, delhi-Delhi

Military Engineer Services-MES has published Tender For Internal Periodical Services And Repair To Flooring False Ceiling Plumbing Roof Treatment And Other Misc Works In Otm Accn Of Delhi Cantt Atc Esd And Fol Depot In Aor Of Age Br Ii Under Ge North Delhi Cantt 10. Submission Date for this Tender is 22-05-2023. Building Work Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37483305
Corrigendum : Tender For Internal Periodical Services And Repair To Flooring False Ceiling Plumbing Roof Treatment And Other Misc Works In Otm Accn Of Delhi Cantt Atc Esd And Fol Depot In Aor Of Age Br Ii Under Ge North Delhi Cantt 10
Open Tender
Indian
Delhi
delhi
22-05-2023

Tender Details

Internal Periodical Services And Repair To Flooring False Ceiling Plumbing Roof Treatment And Other Misc Works In Otm Accn Of Delhi Cantt Atc Esd And Fol Depot In Aor Of Age Br Ii Under Ge North Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-May-2023 Corrigendum 1 BOQ 22-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: INTERNAL PERIODICAL SERVICES AND REPAIR TO FLOORING, FALSE CEILING, PLUMBING, ROOF TREATMENT AND OTHER MISC WORKS IN OTM ACCN OF DELHI CANTT, ATC, ESD AND FOL DEPOT IN AOR OF AGE B/R-II UNDER GE ( NORTH ) DELHI CANTT-10
Sl. No. Item Description
1M & L for preparation of old surfaces of wall/ceiling with the help of mechaniser sander of Make Berger Paints express painting sanding machine or equivalent make (having mechanical vaccum machine with bag for dust collection) to make surface smooth and even complete all as specified and directed.
2M&L forapplying waterproof cement based putty @ 1kg (undiluted) per sq mtr of average thickness 1mm, over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete all as specified and directed. Step 1 : Mix the putty powder by adding 40-50% water and mix it withPutty mixer (Putty mixer with min 1400W power having mixer rod of industrial stell garde 45 with the mixing capacity of min 2.5kg putty per minute). Step 2 : apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application or equivalent having a DC electric motor of 3.3kW having flow speed of max 6 ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041". Step 3: Allow 6-8 hrs time to dry the putty surface. Step 4 : Sanding of the putty surface with Wall Sander: L-01/H-01(having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and as directed
3M&L for one coat of acrylic waterbased interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint applicationhaving an electric motor of min. 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subbsequent quotes.
4M&L for applyingtwo coats of smooth acrylicInterior Premium Emulsion with rich matt finish having voc less than 50 grams per ltr complying leed criteria @ 1ltrs (undiluted)/10Sqm diluted with water in 2:1 ratio applied over priming coatwith fully automatic airless spray machine of paint applicationhaving an electric motor of minimum 1HP with a flow speed of minimum 1ltr per minute having a pressure of 3300psi. Allow 6-8hrs to dry the surface for painting of subsequent quotes.
5M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
6Demolition of brick/stone masonry built in CM. all as specified and directed.
7M&L for brick work with sub class "B" bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6, complete all as specified and directed.
8M&L brick work with sub class B bricks straight or curved on plan to any radiusbuilt in CM 1:6 but except bricks complete all as specified and directed.
9Taking down cement or cement lime plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed.
10M&L for rendering 15mm thick Ready mix Cement Plaster on faces of brick work or concrete surfaces (External )finished even and smooth without using extra cement complete all as specified.
11M&L for preparation of new plastered surface of external wall and making the surface smooth with sand paper and priming the surface wih alkali resistance priming paint for external surface for our primed surface applying two coat of cement base paint including curing complete all as specified.
12M&L for rendering 10 mm thick Ready mix Cement Plaster on faces of brick work or concrete surfaces internal finished even and smooth without using extra cement complete all as specified.
13M&L prepartion of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer and 3mm thickof wall care putty all as specfied and directed.
14M&L for rendering 5mm thick Ready mix Cement Plaster onconcrete surface as in ceiling/chajja and reinforced cement concrect surfaces (Up to 6 mtr height )
15M&L for preparation of new plastered surfaces as on ceiling and applying two coats of white wash, complete all as specified and directed. (Up to 6 mtr height )
16Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level),complete all as specified and directed.
17M&L 40mm thickplain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in floors finished even and smooth using extra cement complete all as specified and directed.
18Supply only glass diving strips 3mm thick and 38mm width inserted in position, confirm to design, complete all as specified and directed.
19Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate, 75mm thick as in plinth protection/pavment and the like, finish the surfaces even and fair without using extra cement all as directed and specified
20Taking down chowkhats or frames with shutters n.exc 1.5 sqm each (without taking off shutters from the frame) complete all as specified and directed.
21Taking down chowkhats or frames with shuttersexc 1.5 sqm but n.exc 4sqm each (without taking off shutters from the frame) complete all as specified and directed.
22Taking downshutters exc 1sqm but not exc 2 sqm each complete all as specified and directed.
23S&F framed work as in doors or gates of angle or other section with gusset plates,rails,braces, etc.,complete drilled for fixing of steel sheeting in or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete all as specified and directed.
24S&F steel windows with side hung shutter including box type hinges with steel handle and steel peg stay complete with glazing/gauging bars, dovetailed or welded complete all as specified and directed.
25Taking downdoor shutters of any description exceeding 1 square metre and not exceeding 2 square metre each easing, and adjusting as required and re-fixing in same opening including renewal of screws complete all as specified and directed.
26S&FMS bars as in window guard bars welded to steel window frame or fixed to wooden frame all as specified and directed.
27Supply and fix 30mm thick, second class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etcwith rails and styles including cut and mitered beards for securing wire cloth etc, complete all as specified and directed.
28S&F 30mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
29Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) Frame worksfor doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief. Note - The rate includes the cost of the materials and labour involved in all the operations described above for fixing of frame/ partition.The cost of anchor bolts or screws for joining the frame is included in the rate. Only any other hardware( i. e. tower bolt, sliding door bolt, handle , Glass etc), which may be required, shall be paid for separately.
30Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and makingprovision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket requiredwithtruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Chief. Note - The rate includes the cost of the materials and labour involved in all the operations described above for fixing of shutters.The cost of anchor bolts or screws for joining the frame is also included in this rate. Only any other hardware ( i. e. tower bolt, sliding door bolt, handle , Glass etc), which may be required, shall be paid for separately.
31S&F in repairs for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in-charge.
32Supply and fix door closer hydraulically regulated,of aluminium(Die cast) body universal type suitable for door shutters851 to 1000mmin width and weight between 38 to 60kg of Hydraulic door closer complete all as specified and directed.
33S & F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
34Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. all as specified and directed.
35S&F glazing of tinted glass 5.5mm thick in aluminium door window shutters and partitions etc with PVC/neoprene gasket etc Complete all as per specified and directed.
36S&F aluminium anodized barrel tower bolts of extruded section of length 150mm , complete all as specified and directed.
37S&F aluminium handle cast type anodized 150mm, complete all as specified and directed.
38S&F 300 mm length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
39S&F 125mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and directed.
40Cutting holes in brick walls built in cement mortar for insertinghold fasts and making good dismentled portion in CM 1:3 or cement concrete 1:2:4 type B-I as required, Exc half brick but not exc one brick wall.
41Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing the serviceable tiles to store and rubbish off the premises etc complete all as specified and directed..
42M&L for glazed ceramic coloured tiles of size 450 X 300 X 7mm thick on vertical surface such as dado, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including layer 10mm thick in cement mortar 1:4 complete all as directed and specified
43"M&Lnon skid coloured ceramic tiles 7 to 8 mm thick (square/rectengular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, over 15mm thick screed bedding layer of mortar inCM 1:6 for laying floor finish complete all as specified and directed.
44M&L for Vetrified Ceramic light shade tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, over 15mm thick screed bedding layer of mortar inCM 1:6 for laying floor finish complete all as specified and directed..
45M&Lnon skid coloured ceramic tiles 7 to 8mm thick (square/rectengular) area in vertical surface as skirting/dado of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, and including layer 10mm thick in cement mortar 1:4 complete all as directed and specified
46M&L for Vetrified Ceramic light shade tiles 10mm thick (Square/rectangular) polished area in vertical surface as skirting/dado of each tile not exceeding 0.36 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, and including layer 10mm thick in cement mortar 1:4 complete all as directed and specified.
47Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories)E53:E54
48S&F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed.
49PVC (SWR) bends of 110mmradius complete all as specified and directed.
50S&F butt hinges med weight cold rolled MS, size 100mm complete all as specified and directed.
51S&F 150mm long mild steel barrel tower bolts, stove enamellled black, with bright bolt and fixed complete all as specified and directed.
52S&F 150mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
53S&F 300mm long mild steel sliding door bolts plate type, store enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
54S&F in repair 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls and ceiling or laid in floor including taking down all as specified.
55S&F in repairs 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls including taking downall as specified.
56M&L for Cutting chases, pinning in Brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and ctting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10cm girth complete all as specified and directed.
57M&L for prepration of old surfaces by Complete removal of existing treatment & levelling of wall surfaceand applying two coats of Oil Bound Distemper over a coat of primer over3 mm thick wall care puttyon surface of wall. complete all as specified and directed by Engr-in-Charge.
58M&L forpreparation of old decorated plastered orunplastered surfaces of wall and applying one coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds, moss,efflorancr salt , trading oil and greasy spot, filling gaps with wall care putty,complete all as specified and directed.
59M&L forpreparation of old decorated plastered orunplastered surfaces of wall and applying two coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds,filling gaps with wall care putty, complete all as specified and directed.
60M&L for preparation of old decorated previously treated surfaces of wall by brooming down scrapping down smoke and efflorescent salts etc and applying one coat of white wash on walls complete all as specified and directed.
61M&L for preparation of old decorated previously treated surfaces ofceiling by brooming down scrapping down smoke and efflorescent etc. completeand applying one coat of white wash complete all as specified and directed.
62S&F in repairsStainless Steel Curtain Rodsof 20mm dia including brackets , side stopcomplete all as specified and directed.
63M&L preparation of new wooden surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
64M&L preparation of old wooden surfaces of any description over 10cm width or girth and apply one coats of synthetic enamel paint complete all as specified and directed.
65M&L preparation of old steel surfaces of any description over 10cm width or girth and apply one coats of synthetic enamel paint .
66Material and labour preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
67Dismantaling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
68S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) ,round or square pipesincluding distance pieces etc.all as specified and direcred.
69Dismantling asbestos cement (corrugated, semicorrugated etc) sheetin roof coverings including ridges,valley gutters etc complete all as directed and specified.
70S&F 6mm thick AC corrugated or semi corrugated sheets in roofs, walls etc fixed with L type or J type or cranked hook bolts and washers in roof complete all as specified and directed.
71S&F6mm thick Asbestos cement two piece serrated ridge , suitable for corrugated or semi corrugated sheet
72Dismantaling plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering all as specified and directed..
73S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed.
74S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, ridges, velly guttersfixed with self tapping screwscomplete all asspecified and directed.
75S&F in repair 2mm thick fibre glass reinforced translucent plain/corrugated sheeting with two corrugation side lape fixed L type or J type or cranked hook bolts and washers in roof complete all as specified.
76Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets, Frame work etcall as specified and directed.
77S&F GI powder coated frame work of size 605 x 605 mm, forceling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre , hanging with 6 mm dia GI Hanger , complete all as specified and as directed.
78M&L 4 mm thick size non asbestos fibre cement building boards fixed or laid / inserted to timber/ GI / Aluminiumframe work with screws complete all as per manufacturers instructions and as directed.
79M&L prepartion of newly plastered surface of Ceilingand distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. Two or more coats on new work , all as specfied and directed.
80S&F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent and fixing at site on PVC frame all as specified and directed by Engineer-in-Charge.
81M&L for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as directed.
82Complete removal of old roof treatment including cement mortar bedding and removing debries out side MOD land ,( except mudfushka) ,complete all as specified and directed.
83M&L for 15mm thick cement plasterover the concrete / brick roof surfaces in cement mortar 1:4mixed with liquid water proofing compound@ 200ml per bag WPC (liquid type) , surface finished even and smooth without using extra cement all as specified and directed. Note :- Water proofing additive shall be measured and paid separately.
84M&L for preparation of roof top surfaces by cleaningall the dust and loose material by brush/blower/Grinder including removing of vegetation/plantation from the surface and providing and applying single component elastic cold applied polyurethane modified acrylic roofing system, co elastic technology (CET) based on modified polyurethane and fully fibre reinforced, having Sun Reflectivity index (SR) of 109 on top of concrete roof surfaces. All cracks up to 3 mm at corner joints, channel and parapets should be treated with crack seal. Applying three coatsincluding one coatof primer ofShaliUrethane BTD/ Sikalastic 560/ smart care damp proof-ultra or equivalent having coverage @ min 0.75kg/m2and dilution up to 10% andlaying reinforced fiber net and applying two coats (without dilution) of shaliUrethane BTD/Sikalastic 560/smart care damp proof ultraor equivalent @totalconsumption 2 kg/m2intwo coats for maintainingminimum dry filmthickness 1.5mm and elongation at breakof free film of approx 350%. The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge/Consultant (Note :6 Hrs interval between two coat will be maintained). All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system. Make: STP/Sika/Asian paint or equivalent as approved by GE. Note:- (i) Application of water proofing treatment will be done by Authorised Applicator duly approved by GE in writing. (ii) The water proofing treatment shall be carried out by the manufacturer or their authorized applicators (iii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However, contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor" risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor"s quoted rates for this item shall deemed to be inclusive of this aspect
85M&L for preparationof roof surfaces ( any type) includingremoval of grass, small trees by picking sweeping , cleaning and washing down with water to remove dust etcand fix the APP based polymeric water proofing membrane of minimum 3mm thickness & weighing not less than 3.6kg/sqm ofapprovedMake : (as approved by GE,) black finished reinforced with non-woven poleyster matt.With a thermofusible finish laid over hot bitumen 85/25 grade @ 1.2 Kg/Sqm over bitumenousprimer at the rate of 0.40 kg/sqm, torching overlaps with a propane or a butane gas torch with a overlap of 100 mm at the sides and 150 mm at the ends and sealing andApplying a coat of bituminous aluminium paint @ 100 Gm /Sqmover bituminous surface all as per manufacturers instructionscomplete all as directed and specified.
86Supply only Liquid integral water proofing compound complete all as specifiedand as directed.
87Racking out old joints of roof tiles andM&L flush pointing in cement mortar (1:3) mixed with modified styrene butadien rubber emulsion (SBR Latex)upto depth of 20mm complete including cutting / removing vegetation, complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy