| 1 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 2 | Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.1:1.5:3 (1cement, 1.5 coarse sand,3 graded stone aggregate of20mm & down size) |
| 3 | Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work, finishing and reinforcements.1:1.5:3 Mix (1cement, 1.5 coarse sand 3 graded stone aggregate 20mm and down nominal gauge) |
| 4 | Filler Joint: Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight |
| 5 | Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber) Foundation, footings, base of column etc for mass concrete. |
| 6 | Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber) Beam, lintels, girders, brersumers and cantilevers. |
| 7 | Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete. |
| 8 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement |
| 9 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 10 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. (Contech/Perma/Zydex/Chryso) |
| 12 | Providing and Laying 12mm thick cement plaster of specified mix with Recorn 3S having a fiber length of 4.8 mm ( 100 gm / bag of cement) in single coat including finishing even and smooth and curing complete - 1:4 mix. |
| 13 | Providing and Providing and painting with plastic Emulsion paints two or more coats on New surface of required shade to give an even shade including brushing the surface clean of all dirt dust and smoothened by sand paper etc complete. |
| 14 | Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering and filling the scratches complete on New surface. |
| 15 | PVC ceiling board with different size and pattern as approved by the Engineer- in-charge and as per manufacturer\"s specification. |
| 16 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 18 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 19 | Providing, fitting, fixing of 24 BWG Pre-painted HULAS sheet roofing with lapping of 150mm (two corrugation) with G.I. hooks, bolts and nut 8mm dia with bitumen, GI limpet washers filled with white bad including carriage all complete |
| 20 | Providing fitting fixing ridges or hips of 60cm overall width of plain 24 BWG Pre-painted HULAS Sheet fixed with G.I, J or L hooks bolts and nuts 8mm dia Limpets, Bitumen washers complete. |
| 21 | Providing and fixing 15cm wide 45cm overall semicircular G.P sheet (Class I) gutter with iron brackets 40x3mm size, bolts, nuts, washers etc including making, connection with rain water pipes. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter |
| 23 | Providing and Fixing the UPVC Door/window with frame (Fenseta/ EnCraft/ Aluplast Make or equivalent) of walnut (wooden finish)/ Rustic Oak/ Golden Oak comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), with 5mm single glazed toughened glass alongwith window slider/casement, fly proof mesh, uPVC extruded glazing beads of appropriate dimension, TPE/EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws, handles, tower bolts including all fittings etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. |