| 1 | Supply and fix in replacement detectors Complying with and type certified to EN - 45 addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and as directed. |
| 2 | Supply and fix in replacement detectors Complying with and type certified to EN - 45 addressable type heat detector with base with rate of rise cum fixed temperature as per lS:2175 complete all as specified and as directed. |
| 3 | Supply and fix in replacement detectors Complying with and type certified to EN - 45 addressable type multisensor detector with heat and smoke combination complete all as specified and as directed. |
| 4 | S & F in repairs LED High bay luminaires 1x195 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source complete all as specified and as directed. |
| 5 | S & F in repairs LED High bay luminaires 1x 200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source complete all as specified and as directed. |
| 6 | Supply and fixin repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED\"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole/high mast pole/wall by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection complete all as specified and as directed. |
| 7 | Supply and fixin repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED\"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole/high mast pole/wall by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connectioncomplete all as specified and as directed. |
| 8 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed. |
| 9 | M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLSCopper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigidPVC casing caping (double interlock type) of suitable width medium dutywith all accessories such as Tees, elbows,junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLSinsulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc all as specified and directed.Note for srl item No. 9 to 11 :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit |
| 10 | All as per item No 09 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor. |
| 11 | All as per item No 09 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor. |
| 12 | All as per item No 09 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor.Note for srl item No. 12 to 13 :- Four runs of cable, two runs of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit |
| 13 | All as per item No 09 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor. |
| 14 | S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connectionscomplete all as specified and as directed |
| 15 | S & F in repairs MCB TPN32 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and as directed |
| 16 | S & F in repairs MCB TPN40 to 63 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and as directed |
| 17 | S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed. |
| 18 | S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and as directed |
| 19 | S & F in repairsMCB SPN06 -32 amps 230 volts C curve, 50 HZ AC 10 KAcomplete all as specified and as directed |
| 20 | S & F in repairsMCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KAcomplete all as specified and as directed |
| 21 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed |
| 22 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed |
| 23 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed |
| 24 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed. |
| 25 | Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB\"s c complete all as specified and as directed. |
| 26 | Supply and fix in repairs MCCB of 63 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB\"s c complete all as specified and as directed. |
| 27 | Supply and Fixing Energy efficient surface Mounted LED Luminire 18/20 watts 4\" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr and removal of old unserviceable lightscomlete all as specified and as directed. |
| 28 | M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials complete all as specified and as directed. |
| 29 | M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. |
| 30 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed. |
| 31 | S & F copper strip 20x3 mm Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed. |
| 32 | S & F Perforatted cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified. |
| 33 | S&F in repair informatory sign boards/display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 mtr x 1 mtr) fixed on wall with screw. nuts and bolts etc. complete all as specified and as directed.Note :- wrightingmatters will be provided by departmaint as per requirment. |
| 34 | M & L for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out goining MCB/MCCBS complete all as specified and as directed. |
| 35 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deepgetting out in hard/dense soil and levelling of bottom surface to required level for laying UG cable / erection of poles complete all as specified and as directed. |
| 36 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep and getting outin soft/disintegrated rock getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 37 | Excavation in trenches by cutting of road crossing/ PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and as directed. |
| 38 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed. |
| 39 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and as directed. |
| 40 | Supplying & Laying in trenches river Sandfor cable cushioning for under ground cable 8 cm below and 15 cm above in level complete all as specified and as directed.Note: Punned thickness only will be measured and paid. |
| 41 | Supplying & Layingprecast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified and as directed. |
| 42 | M& L for cleaning all tanks such as Bar Screen/Chamber-01 Nos (Chamber as well as Bar Screen), Equalisation Tank-01 nos , Chlorine Contact Tank-01 Nos, Filter Feed tank & Sludge Holding Tank-01 Nos, Sludge Drying beds-1 Nos etc by mechanical or manual means including disposal of depositedsludge etconce in a year shall be carried out with water and chemical as applicable and dates of cleaning shall be marked on tank complete all as directed by Engineer-in-charge.Note 1 :-The rates as quoted by the contractor shall be for One times cleaning . |
| 43 | M & L for repair and cleaning of Compressed air networkwith the base of the tanks including welding/soldering, fixing of nuts, bolts,washer at Equalization tank , Sludge holding tank wherever required in existing SS Network complete all as specified and as directed. |
| 44 | M & L 40mm diagalvanised tubing in repairs light gradewith screwed and socket joints including all fittings ISI Marked, laid in trenches/ open as required for protection of of cable complete all as specified and as directed. |
| 45 | M & L 50mm diagalvanised tubing in repairs light grade ,with flanged joints including all fittings ISI Marked laid in trenches/ open as required for protection of of cable complete all as specified and as directed. |
| 46 | M & L 80mm dia galvanised tubing in repairs light grade dia with flanged joints including all fittings ISI Marked laid in trenches/ open as required for protection of of cable complete all as specified and as directed. |
| 47 | M/Lfor fixing in repairs CI specials such as Cast Iron bends (any type, radius and angle), tapers ( any type I.e straight, bend, increasing or decresing or double socket etc) Tee pieces single branch, \"Y\" junction, double branch, cross, collar, caps, connecting pieces up to 200 mm dia complete all as specified and as directed. |
| 48 | Taking out old free floating media and Supply and spread of new free floating fab (media as per existing type for existing FMR Tanksdesign having density less than water.Color of media : Black suitable for STP\"s of 2 MLD complete all as specified and as directed. |
| 49 | Taking out old Pebbles,Gravells ,fine silex , coarse silex and Silica Sand etcfrom the MGF & ACF as per existing media and Supply and spread properly suitable for STP\"s of 2 MLD and making it properly functioning all as specified and as directed |
| 50 | Taking out old carban filteretc from theACF as per existing media and Supply and spreadcarban filtersuitable for STP\"s of 2 MLD and making it properly functioning all as specified and as directed |
| 51 | Supply and Fix in repairs, cast iron double flanged long type,lever operated, butterfly valve,size 80-100 mm, PN 2.0, ISI Marked (IS-13095:1991), including provision of carbon steel nuts, bolts & washers, rubber gaskets etc, fixed to water mains, complete all as specified and as directed |
| 52 | Supply and Fix in repairs, cast iron double flanged long type,lever operated, butterfly valve,size 32-65 mm, PN 2.0, ISI Marked (IS-13095:1991),including provision of carbon steel nuts, bolts & washers, rubber gaskets etc, fixed to water mains, complete all as specified andasdirected |
| 53 | Taking down old unserviceable NRV, supply and installed, connecting and testing ,Non return valve cast iron flanged both end connectingin line with nut bolts, rubber packing etc as per existing type complete all as specified and directed by Engr- in charge |
| 54 | 80 mm bore |
| 55 | 50 to 65mm bore |
| 56 | Supply and fix PVC insulated, PVC sheathed 3 core 1100 volts grade, 2.5 sqmm copper stranded conductor as per IS 694 for providing street light connection complete all as specified and directed. |
| 57 | M & L rewinding of electricmotor 3 phase with suitable size of super enemalled PVC coated copper wire complete duly varnished, baking providing with insulation paper and V-belts etc includings taking out burnt winding wire and painting with two coat of super enamelled paint after one coat of primer complete all as specified and as directed |
| 58 | S & F in replacement of dosing pump of cap 0-55 IPH/0-6IPH, IP65 including connected items with new ones such as dosing pipe, nut, bolts, washer etc complete all as specified by Engineer in charge |
| 59 | M & L for servicing/overhauling of air blower/ compressor with 5-15 HP motor 3 phase including refilling of oil and lubrication of machinecomplete all as specified and directed. Note:- The cost of minor spares such as nut, bolt, washer, oil, lubricant is included in quoted rate by the contractor. |
| 60 | M & L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as per specified and directed. |
| 61 | M & L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate as in foundation, filling and mass concrete all as per specified and directed. |
| 62 | M & L for80mm bore Cast iron/Ductile iron pipe with spigot and socket end centrifugally cast class LA in any length conforming to IS-1536 of 1976 laid in trenches including taking down existing pipe complete and all as specified and directed the following sizes . Make: Kesoram spun pipe Ltd/ Eelectro steel casting Ltd / Kalinga.(Note- Excavation, earth work CI /DI fitting & lead joint shall be measured and paid for separately ) |
| 63 | Supply and fix in repair PVC/Polycarbonate made junction box having two incoming and one outgoing cable ways alongwith fixing arrangement complete including 01 Nos 6 Amp MCB SP for security light all as specified and directed. Make : Hensel/HPL/Sintex or equivalent make as approved by GE. |
| 64 | S & F in repairs Energy efficient LED street Light Luminaire 90 watts capacity comprises a die-cast aluminium housing including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded from LT over head line/junction box to the connector of fitting, (connection wires shall not be less than 2.5 metre in length duly run through GI bracket) complete all as specified and as directed. |
| 65 | S & F in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape of approx length 1.0mtr long suitable for security/street light fittings with necessary MS clamps - 02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed |
| 66 | S & F in repairs LT PanelCPRI Approved suitable for 1100 Volt gradeindoor type, doubledoor, pedestal mounted having copper busbar busof600 A capacity - 04 Nos with necessary hole for connection of LT cables mounted , dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheetsuitable for 3 Phase 4 wite system, duly insulated with heat shrinkable type coloured sleeve, supported on suitable size \"C\" Channel in the vertical position - 03 Nos , provision for Main incomming and Starters , LT danger notice board fixed on dooron both side, with independent plates at bottom for each out going and in coming cables in cable alley and painted with powder coatingin Siemens grey colour all as approved andas directed. |
| 67 | Incoming :- a)MCCB 4 Pole,250 Amp 16KA415V - 01 No.Outgoing :- b)MCCB 4 Pole 63 Amp - 02 Nos c)MCB TP 32 Amps - 09 Nosd) MCB SPN 32 Amps -01 Noe)Including DOL Starter 1-3 hp -06 Nos (Protection with single phase, Reversal ,and overload)f)Including DOL Starter 5-10 hp -02 Nos (Protection with single phase, Reversal ,and overload)g) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch - 01 Seth) Digital Amp Meter 0 - 100 Amp, size 96x96 mm square type with selector switch- 01 Set.i) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.j) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.k) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job |
| 68 | S & F in repairs UPVCTubings with all fitting and fixtures fixed on wall/floor/trench complete all as specified and directed of the 75/100 mm Bore sizes complete all as specified and as directed. |
| 69 | Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 70 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified. |
| 70 | Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 35 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified. |
| 71 | M& L for cleaning of diffuser by taking out etc by mechanical or manual and refixing of diffuser as per existing complete all as specified. |
| 72 | M &L brick/ stone work with burnt bricks/ stone best quality locally available old size laid staright or curved on planto any radius built in cement mortar 1:4 for e/m installation /vavle chambercomplete all as directed including dismantling old disturbed surfaces |
| 73 | M &L rendering in 10mm thick on fair faces of brick/ stone work in cement mortar 1:4 and finish the surface fair and even complete all as directed. |
| 74 | Material and lobour of iron work for making grill over sewage tank including welding making it suitable as per existing all as directed by engr-in-charge.(Note :- one coat of primer and two coat of synthetic enamell paint are includec in the quoted rate.) |
| 75 | M & L of pressure gauge for measurment of air flow pressure as per existing model complete all as specified and directed by engr-in-charge. |
| 76 | (a) 80 mm bore |
| 77 | (b) 32 to 65 mm bore |
| 78 | S & F of one HP Motor with pump suitable for pumping of treated water suitable for 50 hz 220 volts AC supply complete |
| 79 | S & F perforated cable tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, completeall asspecified and as directed. |