Public Health Engineering Department-PHED has published Tender For Fixing Of Rate Contract For Repairs/ Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara (District Anantnag And Kulgam) For The Financial Year 2023-24. Submission Date for this Tender is 02-05-2023. Electrical Products Tenders in bijbehara Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 01-May-2023 | Corrigendum | Technical Bid | 02-05-2023 |
Sl. No. | Item Description |
1 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: |
2 | Private car, auto-rickshaw or similar with 1.0 km lead |
3 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
4 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
5 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
6 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
7 | Load carrier auto, mini van or similar with 1.0 km lead |
8 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
9 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
10 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
11 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
12 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
13 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
14 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
15 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
16 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
17 | VOLTAGE STABILIZERS Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. |
18 | upto 50 kVA |
19 | >50 upto 100kVA |
20 | >100kVA upto 250 kVA |
21 | Greater than 250 kVA |
22 | Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil |
23 | upto 50 kVA |
24 | >50 upto 100kVA |
25 | >100kVA upto 250 kVA |
26 | Greater than 250 kVA |
27 | Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. |
28 | >60 upto 200 HP |
29 | Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) |
30 | Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc) (Process loss maximum of 5% allowed) |
31 | Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). |
32 | 10kVA rating |
33 | 30kVA rating |
34 | 50kVA rating |
35 | 75kVA rating |
36 | 100kVA rating |
37 | 150kVA rating |
38 | 175kVA rating |
39 | 200kVA rating |
40 | 250kVA rating |
41 | Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work |
42 | 10kVA rating |
43 | 30kVA rating |
44 | 50kVA rating |
45 | 75kVA rating |
46 | 100kVA rating |
47 | 150kVA rating |
48 | 175kVA rating |
49 | 200kVA rating |
50 | 250kVA rating |
51 | Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature. |
52 | 10kVA rating |
53 | 30kVA rating |
54 | 50kVA rating |
55 | 75kVA rating |
56 | 100kVA rating |
57 | 150kVA rating |
58 | 175kVA rating |
59 | 200kVA rating |
60 | 250kVA rating |
61 | Removing of damaged copper connection terminal bolt with washer and nut from3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. |
62 | 10kVA rating |
63 | 30kVA rating |
64 | 50kVA rating |
65 | 75kVA rating |
66 | 100kVA rating |
67 | 150kVA rating |
68 | 175kVA rating |
69 | 200kVA rating |
70 | 250kVA rating |
71 | 500kVA rating |
72 | Hiring of portable welding set /soldering equipment etc. excluding power charges |
73 | Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch) |
74 | Providing and replacement of copper contact points on regulator plate |
75 | Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) |
76 | STARTER Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. |
77 | upto 60 HP rating |
78 | >60 upto 200 HP |
79 | >200 HP upto 350 HP |
80 | greater than 350 HP |
81 | Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. |
82 | upto 60 HP rating |
83 | >60 upto 200 HP |
84 | >200 HP upto 350 HP |
85 | greater than 350 HP |
86 | CONTACTORS Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: |
87 | L&T ML 1.5 |
88 | L&T ML 2 |
89 | L&T ML 3 |
90 | L&T ML 4 |
91 | L&T ML 6 |
92 | L&T ML 12 |
93 | L&T MNX 50 |
94 | L&T MNX 70 |
95 | L&T MNX 80 |
96 | L&T MNX 95 |
97 | L&T MNX 110 |
98 | L&T MNX 140 |
99 | L&T MNX 185 |
100 | L&T MNX 225 |
101 | L&T MNX 250 |
102 | MK1 |
103 | MK2 |
104 | MU1 |
105 | MU1H |
106 | MU2 |
107 | MU3 |
108 | ML2W |
109 | ML3W |
110 | ML4W |
111 | ML6W |
112 | Schneider Electric LC1F265 (without coil) |
113 | Schneider Electric LC1F330 (without coil) |
114 | Schneider Electric LC1F400 (without coil) |
115 | Schneider Electric LC1F630 (without coil) |
116 | 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) |
117 | 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) |
118 | Providing and fitting of new AC coil with specified coil voltage for contactors: |
119 | 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) |
120 | L&T ML 2/ 3 |
121 | L&T ML 4/ 6 |
122 | L&T ML 10/ 12 |
123 | L&T MNX 50/ 70/ 80 |
124 | L&T MNX 95/ 110/ 140 |
125 | L&T MNX 185/ 225/ 250 |
126 | L&T MNX 300/ 400 |
127 | L&T MNX 550/ 650 |
128 | Schneider Electric LC1F185/ LC1F225 |
129 | Schneider Electric LC1F265/ LC1F330 |
130 | Schneider Electric LC1F400 |
131 | Schneider Electric LC1F630 |
132 | Providing and fitting of new Contact kit set for contactors |
133 | 32A AC-3 rating (Siemens 3TF/equivalent) |
134 | L&T ML 2 |
135 | L&T ML 3 |
136 | L&T ML 4 |
137 | L&T ML 6 |
138 | L&T ML 10 |
139 | L&T ML 12 |
140 | Providing and fitting of auxillary contactors/ control relay |
141 | L&T MX0 having 04 contacts (all combinations) for AC control |
142 | L&T MX0 having 04 contacts (all combinations) for DC control |
143 | L&T ML (1NO+1NC) side mounting auxillary contact block |
144 | L&T MNX/MCX front mounting type having 04 contacts (all combinations) |
145 | TIMING RELAYS Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) |
146 | Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . |
147 | (2NO + 2NC) double block; ON delay |
148 | (2NO + 2NC) double block; ON & OFF delay |
149 | Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) |
150 | (2NO + 2NC) contact block |
151 | Magnetic coil 415V AC |
152 | Magnet frame assembly without coil |
153 | Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make) |
154 | Star Delta (range from 3s - 120s)240V AC |
155 | Star Delta (range from 3s - 30s)240 - 415V AC |
156 | ON delay (0.3s - 30hrs) 240V AC |
157 | THERMAL OVERLOAD RELAY Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) |
158 | Relay range in between 0.2A to 15A |
159 | 14-23A |
160 | 20-33A |
161 | 24-40A |
162 | Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) |
163 | 20-33A |
164 | 30-50A |
165 | 36-60A |
166 | 45-75A |
167 | 66-110A |
168 | Providing, fitting and setting of thermal overload relay of specified relay range |
169 | L&T ML1 (Relay range in between 0.15A to 16A) |
170 | L&T ML2/3 (Relay ranges in between 9A to 42A) |
171 | MISCELLANEOUS |
172 | Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots |
173 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. |
174 | Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. |
175 | OIL IMMERSED STARTER SPARES Providing and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP |
176 | Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts), upto 40 HP |
177 | Spares for oil immersed manual starters |
178 | Fixed finger contact |
179 | Moving tip contact |
180 | No volt coil |
181 | Moving drum contact (starters upto 40HP) |
182 | Moving drum contact (starters > 40HP) |
183 | Base plate Bakelite/ DMC (starters upto 40HP) |
184 | Base plate Bakelite/ DMC (starters > 40HP) |
185 | Steam carrier assembly (starters upto 40HP) |
186 | Steam carrier assembly (starters > 40HP) |
187 | Sequence shaft (starters upto 40HP) |
188 | Sequence shaft (starters > 40HP) |
189 | Bakelite tube for Sequence shaft (starters upto 40HP) |
190 | Bakelite tube for Sequence shaft (starters > 40HP) |
191 | Trip rod assembly (starters upto 40HP) |
192 | Trip rod assembly (starters > 40HP) |
193 | Lock lever |
194 | Cam assembly |
195 | Oil dashpot assembly |
196 | Overload coil (set of 03 nos.) upto 20HP |
197 | Overload coil (set of 03 nos.) 30- 40HP |
198 | Overload coil (set of 03 nos.) 50- 60HP |
199 | Overload coil (set of 03 nos.) 70- 80HP |
200 | Overload coil (set of 03 nos.) 90- 100HP |
201 | L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARES Volt-Ammeter 500V, |
202 | Electronic Star-Delta Timer 3-30s |
203 | Providing and fitting of Terminal Block |
204 | 60A - 3 way |
205 | 100A - 3 way |
206 | Single phase preventing relay Sz5 type |
207 | Single phase preventing relay SDz5 type |
208 | Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T) |
209 | MK1 (all ranges) |
210 | MU1 (all ranges) |
211 | MU2 relays of following ranges |
212 | 6 -10 A, 9 - 14A |
213 | 13 - 21A |
214 | 15 - 25A |
215 | 20 - 32A |
216 | 24 - 38A |
217 | 28 - 42A |
218 | Providing and fitting of standard operating coil for following contactors |
219 | MK1/ MK2 |
220 | MU1/ MU2/ MU3 |
221 | Providing and fitting of contact bridge without contact of following contactors |
222 | MK1/ MK2 |
223 | MU1/ MU2/ MU3 |
224 | Providing and fitting of single moving contact of following contactors |
225 | MK1 |
226 | MK2 |
227 | MU1 |
228 | MU2 |
229 | MU3 |
230 | Indicating lamps |
231 | Rocker switch |
232 | Rocker switch (MUG-G6 to MUG G20) |
233 | Rocker switch (MUG-G30 to MUG G75) |
234 | Voltage Selector switch |
235 | 30A Ammeter Spare for MR-G Controller |
236 | Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec. |
237 | Electronic star -Delta timer for MUG Starters |
238 | Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec. |
239 | Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter |
240 | Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge |
241 | Providing and fitting of MU1/MU2 Relay extension job to MUG submersible starter |
242 | Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter |
243 | Providingand fitting of New MUG after removing old damaged ones |
244 | MUG 6, 6-10 Amp relay |
245 | MUG 6, 9-14 Amp relay |
246 | MUG 10, 13-21 Amp relay |
247 | MUG 10, 20-32 Amp relay |
248 | MUG 10, 28-42 Amp relay |
249 | MUG 15, 11-18 Amp relay |
250 | MUG 15, 13-22 Amp relay |
251 | MUG 20, 9-14 Amp relay |
252 | MUG 20H, 20-32 Amp relay |
253 | MUG 20H, 28-42 Amp relay |
254 | MUG 30, 20-33 Amp relay |
255 | MUG 30, 30-50 Amp relay |
256 | MUG 40, 30-50 Amp relay |
257 | MUG 40, 36-60 Amp relay |
258 | MUG 50,36-50 Amp relay |
259 | MUG 50, 45-75 Amp relay |
260 | MUG 75, 45-75 Amp relay |
261 | MUG 75, 66-110 Amp relay |
262 | MCCB Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: |
263 | upto and including 100A (Ics= 50% Icu) |
264 | 125A |
265 | 160A |
266 | 200A |
267 | 250A |
268 | 400A |
269 | Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under: |
270 | 125A |
271 | 160A |
272 | 200A |
273 | 250A |
274 | 400A |
275 | 630A |
276 | Providing of set of spreader terminals for above 3-pole MCCBs |
277 | 100A |
278 | 125A |
279 | 250A |
280 | 400A |
281 | 630A |
282 | Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: |
283 | 125A |
284 | 160A |
285 | 200A |
286 | 250A |
287 | 400A |
288 | 630A |
289 | SPARES FOR ACB (L&T C-POWER) Providing and fitting of pole assembly for draw out type ACB (L&T C-power) |
290 | upto 1250A |
291 | 2000A |
292 | Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) |
293 | upto 1250A |
294 | 1600 - 2000A |
295 | Providing and fitting of Jaw contact for ACB (L&T C-power) |
296 | 630-1000A |
297 | 1250A |
298 | 1600A/ 2000A |
299 | Providing and fitting of Fixed arcing contact for ACB (L&T C-power) |
300 | 800- 1600A |
301 | 2000A |
302 | Providing and fitting of Moving arcing contact for ACB (L&T C-power) |
303 | 800- 2000A |
304 | Providing and fitting of Shunt release for ACB (L&T C-power) |
305 | Providing and fitting of Under Voltage Release for ACB (L&T C-power) |
306 | Providing and fitting of Moving arcing contact for ACB (L&T C-power) |
307 | Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: |
308 | upto 800 - 1250A |
309 | 1600 - 2000A |
310 | Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB |
311 | Providing and fitting of CT for DN1 type L&T C-power ACB |
312 | 800/ 1000A |
313 | 1250/ 1600A |
314 | 2000A |
315 | Providing and fitting of main spring for 3-pole ACB (L&T C-power) |
316 | 800- 1600A |
317 | 2000A |
318 | Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A |
319 | Providing and replacement of spring charging motor (AC/ DC) |
320 | Providing and replacement of motor limit switch |
321 | INSTRUMENTATION AND PANEL ACCESSORIES Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) |
322 | Providing and fitting of flush type analog moving iron AC meter as under: (Make: Rishabh/ AE/ C&S/ BCH) |
323 | 48x48mm 500V voltmeter |
324 | 96x96mm 500V voltmeter |
325 | 144x144mm 500V voltmeter |
326 | 96x96mm ammeter (5A CT operated) |
327 | Providing and fitting of flush type frequency meter with range 45-55Hz: (Make: Rishabh/ AE/ L&T/ Schneider/ BCH) |
328 | Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) |
329 | Providing and fitting of 10A voltmeter selector switch with OFF (Make: L&T/ Rishabh/ AE/ Teknic) |
330 | Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: |
331 | 100/5A or 150/5A - Class 1 - Burden 5VA |
332 | 200/5A - Class 1 - Burden 10VA |
333 | 400/5A - Class 1 - Burden 15VA |
334 | 600/5A - Class 1 - Burden 15VA |
335 | 800/5A - Class 1 - Burden 15VA |
336 | 1000/5A - Class 1 - Burden 15VA |
337 | 2000/5A - Class 1 - Burden 15VA |
338 | Extra for 1A secondary upto 600/1A over corresponding rate |
339 | Providing and fitting of analog VAC hour meter (Make: L&T or equivalent make) |
340 | DIN mounting type |
341 | Flush mounting type |
342 | Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
343 | Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
344 | Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) |
345 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) |
346 | 50V or less unbalance & 1 C/ODIN mounted |
347 | 50V or less unbalance & 1 C/OPanel wall mounted |
348 | 70V or less unbalance & 2 C/ODIN mounted |
349 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) |
350 | Providing of HRC fuses (2A - 32A) ratings |
351 | Providing and fitting of Fuse holders for fuses upto 32A rating |
352 | Providing and fixing uPVC panel trunking with cover |
353 | 15x15mm |
354 | 25x25mm |
355 | TERMINALS/LUGS Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
356 | 16 sq. mm |
357 | 25 sq. mm |
358 | 35 sq. mm |
359 | 50 sq. mm |
360 | 70 sq. mm |
361 | 95 sq. mm |
362 | 120 sq. mm |
363 | 150 sq. mm |
364 | 185 sq. mm |
365 | 225 sq. mm |
366 | 240 sq. mm |
367 | 300 sq. mm |
368 | Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
369 | 16 sq. mm |
370 | 25 sq. mm |
371 | 35 sq. mm |
372 | 50 sq. mm |
373 | 70 sq. mm |
374 | 95 sq. mm |
375 | 120 sq. mm |
376 | 150 sq. mm |
377 | 185 sq. mm |
378 | 225 sq. mm |
379 | 240 sq. mm |
380 | 300 sq. mm |
381 | CABLES Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) |
382 | 1.5 sqmm |
383 | 2.5 sqmm |
384 | 4.0 sqmm |
385 | 6.0 sqmm |
386 | 10.0 sqmm |
387 | 16.0 sqmm |
388 | 25.0 sqmm |
389 | 35.0 sqmm |
390 | Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
391 | 16.0 sqmm |
392 | 25 sqmm |
393 | 35 sqmm |
394 | 50 sqmm |
395 | 70 sqmm |
396 | 95 sqmm |
397 | 120 sqmm |
398 | 150 sqmm |
399 | 185 sqmm |
400 | 240 sqmm |
401 | 300 sqmm |
402 | 400 sqmm |
403 | Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
404 | 16 sqmm |
405 | 25 sqmm |
406 | 35 sqmm |
407 | 50 sqmm |
408 | 70 sqmm |
409 | 95 sqmm |
410 | 120 sqmm |
411 | 150 sqmm |
412 | 185 sqmm |
413 | 240 sqmm |
414 | 300 sqmm |
415 | Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
416 | 25 sqmm |
417 | 35 sqmm |
418 | 50 sqmm |
419 | 70 sqmm |
420 | 95 sqmm |
421 | 120 sqmm |
422 | 150 sqmm |
423 | 185 sqmm |
424 | 240 sqmm |
425 | 300 sqmm |
426 | WIRING Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) |
427 | 1.0 sqmm |
428 | 1.5 sqmm |
429 | 2.5 sqmm |
430 | 4.0 sqmm |
431 | 6.0 sqmm |
432 | 10.0 sqmm |
433 | 16.0 sqmm |
434 | 2x1.5 sqmm |
435 | 2x2.5 sqmm |
436 | 2x6 sqmm (Aluminium unarmoured) |
437 | CONDUITS |
438 | Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings |
439 | Providing and fixing uPVC trunking 25x16mm with allied fittings |
440 | Providing and fixing Polypropylene Corrugated flexible conduit |
441 | 25mm |
442 | 32mm |
443 | Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. |
444 | 100 x 50 x 1.6mm |
445 | 150 x 50 x 1.6mm |
446 | ELECTRICAL FITINGS Providing and fitting of various electrical fittings as under (Preferred makes: Anchor/ SSK/ Havells) |
447 | Switch-6A-SP-1way, 240V, 50 Hz, AC. |
448 | Switch-6A-SP-2way, 240V, 50 Hz, AC. |
449 | Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. |
450 | Bell push 240V, 50 Hz, AC. |
451 | 6A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC. |
452 | Neon indicator |
453 | Mini telephone jack |
454 | Fan regulator (Mini) with rotary step |
455 | Fan regulator (Deluxe) with rotary step |
456 | Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC. |
457 | Plug Top 15/16A 3 Pin (ISI Marked) |
458 | 32A TP switch 415V with neon |
459 | 32A DP switch 240V with neon |
460 | Surface mounting box for switches as follows: |
461 | 1 Gang box |
462 | 2 Gang box |
463 | 3 Gang box |
464 | 4 Gang box |
465 | 5 Gang box |
466 | 6 Gang box |
467 | 7 Gang box |
468 | 4 Gang box (double domestic) |
469 | Providing, Fixing, Testing of 6A ceiling rose |
470 | Providing and installation of Pendant/ angle/ batten holders 6A 240V |
471 | Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) |
472 | 4 way |
473 | 8 way |
474 | 12 way |
475 | 16 way |
476 | Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) |
477 | 6-32A SP |
478 | 40A SP |
479 | 6-32A DP |
480 | 40A DP |
481 | 100A 4P isolator |
482 | Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) |
483 | 2-pole 16A 415V |
484 | 2-pole 32A 415V |
485 | 4-pole 32A 415V |
486 | 4-pole 63A 415V |
487 | 4-pole 100A 415V |
488 | Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T) |
489 | 63A 415V |
490 | 100A 415V |
491 | 200A 415V |
492 | MANPOWER |
493 | Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): |
494 | Hiring charges of Labourer for support of electrician |
495 | Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m |
496 | Pipes, cables etc, not exceeding 80 mm dia. |
497 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
498 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia |
499 | Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia |
500 | Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). |
501 | Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) |