Tender For Fixing Of Rate Contract For Repairs/ Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara (District Anantnag And Kulgam) For The Financial Year 2023-24, bijbehara-Jammu And Kashmir

Public Health Engineering Department-PHED has published Tender For Fixing Of Rate Contract For Repairs/ Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara (District Anantnag And Kulgam) For The Financial Year 2023-24. Submission Date for this Tender is 02-05-2023. Electrical Products Tenders in bijbehara Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37326294
Corrigendum : Tender For Fixing Of Rate Contract For Repairs/ Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara (District Anantnag And Kulgam) For The Financial Year 2023-24
Open Tender
Indian
Jammu And Kashmir
bijbehara
02-05-2023

Tender Details

Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara ( District Anantnag And Kulgam ) For The Financial Year 2023-24- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 8 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 9 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 10 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 11 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 12 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 13 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 14 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 15 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 16 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 17 Voltage Stabilizersdismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 18 Upto 50 Kva 19 >50 Upto 100Kva 20 >100Kva Upto 250 Kva 21 Greater Than 250 Kva 22 Assembling Of All Parts Of 3-Ph Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 23 Upto 50 Kva 24 >50 Upto 100Kva 25 >100Kva Upto 250 Kva 26 Greater Than 250 Kva 27 Isolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 28 >60 Upto 200 Hp 29 Providing Of Transformer Oil Conforming To Is 335 ( Preferred Make: Power Oil / Indian Oil Servo / Hpcl ) 30 Filtration Of Existing / Reclaimed T-Oil At Suitable Temperature ( Inclusive Of All Logistics And Charges For Filtration Plant, Etc ) ( Process Loss Maximum Of 5% Allowed ) 31 Rewinding Burnt / Damaged Windings Of Voltage Stabilizer Coil Assembly ( Comprising Of Three Limbs ) Using Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 32 10Kva Rating 33 30Kva Rating 34 50Kva Rating 35 75Kva Rating 36 100Kva Rating 37 150Kva Rating 38 175Kva Rating 39 200Kva Rating 40 250Kva Rating 41 Removing Of Damagedplate Type Voltage Regulator Switch From 3 Phase , 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Plate Type Voltage Regulator Switch Having Copper Contact Points With 6 Steps. The Job Includes Cost On Account Of Skilled / Semi-Skilled Labour Required For Work 42 10Kva Rating 43 30Kva Rating 44 50Kva Rating 45 75Kva Rating 46 100Kva Rating 47 150Kva Rating 48 175Kva Rating 49 200Kva Rating 50 250Kva Rating 51 Impregnation / Heat Treatment Ofwinding Assembly Of 3 Phase, 415 ±15 % Volt Voltage Stabilizerby Way Of Keeping It In An Electric Oven For About 24 Hours And At Approperate Temperature. 52 10Kva Rating 53 30Kva Rating 54 50Kva Rating 55 75Kva Rating 56 100Kva Rating 57 150Kva Rating 58 175Kva Rating 59 200Kva Rating 60 250Kva Rating 61 Removing Of Damaged Copper Connection Terminal Bolt With Washer And Nut From3 Phase, 415 ±15 % Volt Voltage Stabilizer And Providing And Fitting Of New Copper Connection Terminal Bolt With Nut And Washer. 62 10Kva Rating 63 30Kva Rating 64 50Kva Rating 65 75Kva Rating 66 100Kva Rating 67 150Kva Rating 68 175Kva Rating 69 200Kva Rating 70 250Kva Rating 71 500Kva Rating 72 Hiring Of Portable Welding Set / Soldering Equipment Etc. Excluding Power Charges 73 Arresting Of Leakage In, 3 Phase , 415 ±15 % Volt Voltage Stabilizer Tank Along With Radiator Fins / Tubesby Way Of Soldering / Welding At The Cracked Spot ( Average Length Of Spot = 1 Inch ) 74 Providing And Replacement Of Copper Contact Points On Regulator Plate 75 Providing And Fitting Of Lv Copper Terminal Connectors With Allied Insulation _ ( For Finished Weight Of The Connector ) 76 Starterisolating And Disconnecting Of All Incoming And Outgoing Leads From Autotransformer Starter. Draining Out Transformer Oil From The Oil Tank And Collecting In A Suitable Vessel. Taking Out The Damaged Autotransformer Coil Assembly From Oil Tank. 77 Upto 60 Hp Rating 78 >60 Upto 200 Hp 79 >200 Hp Upto 350 Hp 80 Greater Than 350 Hp 81 Fitting Of Autotransformer Coil Assembly In The Starter Oil Tank, Filling Of T.Oil In The Tank, Connecting All Leads And Load Testing Of The Starter. 82 Upto 60 Hp Rating 83 >60 Upto 200 Hp 84 >200 Hp Upto 350 Hp 85 Greater Than 350 Hp 86 Contactorsproviding And Fitting Of 3-Pole Contactor ( Ac-3 Duty ) With Specified Coil Voltage: 87 L&T Ml 1.5 88 L&T Ml 2 89 L&T Ml 3 90 L&T Ml 4 91 L&T Ml 6 92 L&T Ml 12 93 L&T Mnx 50 94 L&T Mnx 70 95 L&T Mnx 80 96 L&T Mnx 95 97 L&T Mnx 110 98 L&T Mnx 140 99 L&T Mnx 185 100 L&T Mnx 225 101 L&T Mnx 250 102 Mk1 103 Mk2 104 Mu1 105 Mu1h 106 Mu2 107 Mu3 108 Ml2w 109 Ml3w 110 Ml4w 111 Ml6w 112 Schneider Electric Lc1f265 ( Without Coil ) 113 Schneider Electric Lc1f330 ( Without Coil ) 114 Schneider Electric Lc1f400 ( Without Coil ) 115 Schneider Electric Lc1f630 ( Without Coil ) 116 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 117 45A Ac-3 Rating With 2No + 2Nc Auxillary Contacts ( Siemens 3Tf / L&T Type Mo / Schneider ) 118 Providing And Fitting Of New Ac Coil With Specified Coil Voltage For Contactors: 119 9A To 45A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 120 L&T Ml 2 / 3 121 L&T Ml 4 / 6 122 L&T Ml 10 / 12 123 L&T Mnx 50 / 70 / 80 124 L&T Mnx 95 / 110 / 140 125 L&T Mnx 185 / 225 / 250 126 L&T Mnx 300 / 400 127 L&T Mnx 550 / 650 128 Schneider Electric Lc1f185 / Lc1f225 129 Schneider Electric Lc1f265 / Lc1f330 130 Schneider Electric Lc1f400 131 Schneider Electric Lc1f630 132 Providing And Fitting Of New Contact Kit Set For Contactors 133 32A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 134 L&T Ml 2 135 L&T Ml 3 136 L&T Ml 4 137 L&T Ml 6 138 L&T Ml 10 139 L&T Ml 12 140 Providing And Fitting Of Auxillary Contactors / Control Relay 141 L&T Mx0 Having 04 Contacts ( All Combinations ) For Ac Control 142 L&T Mx0 Having 04 Contacts ( All Combinations ) For Dc Control 143 L&T Ml ( 1No+1Nc ) Side Mounting Auxillary Contact Block 144 L&T Mnx / Mcx Front Mounting Type Having 04 Contacts ( All Combinations ) 145 Timing Relaysproviding, Fitting And Setting Up Of Single Range Auto Reset Synchronous On Delay Timer ( L&T Or Equivalent Make ) 146 Providing, Fitting And Setting Of Electropneumatic Timing Relay With Timing Range Upto 60S; Coil Voltage 415V Ac ( Bch Or Equivalent Make ) . 147 ( 2No + 2Nc ) Double Block; On Delay 148 ( 2No + 2Nc ) Double Block; On & Off Delay 149 Providing And Fitting Of Spares For Electropneumatic Timing Relay ( Bch Make Or Equivalent ) 150 ( 2No + 2Nc ) Contact Block 151 Magnetic Coil 415V Ac 152 Magnet Frame Assembly Without Coil 153 Providing, Fitting And Setting Of Din Mounted Electronic Timer ( L&T Gic Or Equivalent Make ) 154 Star Delta ( Range From 3S - 120S ) 240V Ac 155 Star Delta ( Range From 3S - 30S ) 240 - 415V Ac 156 On Delay ( 0.3S - 30Hrs ) 240V Ac 157 Thermal Overload Relayproviding, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn2 ) 158 Relay Range In Between 0.2A To 15A 159 14-23A 160 20-33A 161 24-40A 162 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn5 ) 163 20-33A 164 30-50A 165 36-60A 166 45-75A 167 66-110A 168 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range 169 L&T Ml1 ( Relay Range In Between 0.15A To 16A ) 170 L&T Ml2 / 3 ( Relay Ranges In Between 9A To 42A ) 171 Miscellaneous 172 Providing And Fitting Of Bakelite Connection Plate Minimum 10Mm Thick As Per Given Size For Autotransformer With Holes For Connection Studs Drilled At Requisite Spots 173 Complete Servicing Of Control Wiring Of Ats Including Checking, Tightening Of Connections, Tapping And Insulation As Per Requirement. 174 Complete Replacement Of Suitable Copper Control Wiring Of Ats Including Cable Ties, Connections, Tapping And Insulation As Per Requirement. 175 Oil Immersed Starter Sparesproviding And Replacement Of Operating Coil For Oil Immersed Semi-Automatic Starter, Upto 40Hp 176 Providing And Fitting Of Heavy Duty Contact Kit Set For Semi-Automatic / Fully Automatic Sd Oil Immersed Starters ( Set Of 03 Moving And 06 Stationary Contacts ) , Upto 40 Hp 177 Spares For Oil Immersed Manual Starters 178 Fixed Finger Contact 179 Moving Tip Contact 180 No Volt Coil 181 Moving Drum Contact ( Starters Upto 40Hp ) 182 Moving Drum Contact ( Starters > 40Hp ) 183 Base Plate Bakelite / Dmc ( Starters Upto 40Hp ) 184 Base Plate Bakelite / Dmc ( Starters > 40Hp ) 185 Steam Carrier Assembly ( Starters Upto 40Hp ) 186 Steam Carrier Assembly ( Starters > 40Hp ) 187 Sequence Shaft ( Starters Upto 40Hp ) 188 Sequence Shaft ( Starters > 40Hp ) 189 Bakelite Tube For Sequence Shaft ( Starters Upto 40Hp ) 190 Bakelite Tube For Sequence Shaft ( Starters > 40Hp ) 191 Trip Rod Assembly ( Starters Upto 40Hp ) 192 Trip Rod Assembly ( Starters > 40Hp ) 193 Lock Lever 194 Cam Assembly 195 Oil Dashpot Assembly 196 Overload Coil ( Set Of 03 Nos. ) Upto 20Hp 197 Overload Coil ( Set Of 03 Nos. ) 30- 40Hp 198 Overload Coil ( Set Of 03 Nos. ) 50- 60Hp 199 Overload Coil ( Set Of 03 Nos. ) 70- 80Hp 200 Overload Coil ( Set Of 03 Nos. ) 90- 100Hp 201 L&T Mu-G Submersible Pump Controller Sparesvolt-Ammeter 500V, 202 Electronic Star-Delta Timer 3-30S 203 Providing And Fitting Of Terminal Block 204 60A - 3 Way 205 100A - 3 Way 206 Single Phase Preventing Relay Sz5 Type 207 Single Phase Preventing Relay Sdz5 Type 208 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T ) 209 Mk1 ( All Ranges ) 210 Mu1 ( All Ranges ) 211 Mu2 Relays Of Following Ranges 212 6 -10 A, 9 - 14A 213 13 - 21A 214 15 - 25A 215 20 - 32A 216 24 - 38A 217 28 - 42A 218 Providing And Fitting Of Standard Operating Coil For Following Contactors 219 Mk1 / Mk2 220 Mu1 / Mu2 / Mu3 221 Providing And Fitting Of Contact Bridge Without Contact Of Following Contactors 222 Mk1 / Mk2 223 Mu1 / Mu2 / Mu3 224 Providing And Fitting Of Single Moving Contact Of Following Contactors 225 Mk1 226 Mk2 227 Mu1 228 Mu2 229 Mu3 230 Indicating Lamps 231 Rocker Switch 232 Rocker Switch ( Mug-G6 To Mug G20 ) 233 Rocker Switch ( Mug-G30 To Mug G75 ) 234 Voltage Selector Switch 235 30A Ammeter Spare For Mr-G Controller 236 Volt Ammeter ( 30A, 300V Ac ) For 3-30 Sec Or 12-20 Sec. 237 Electronic Star -Delta Timer For Mug Starters 238 Electronic Star -Delta Timer Type St100, 160 - 500V, For 3-30 Sec Or 12-20 Sec. 239 Providing And Fitting Of Mu Coil 240 / 360 / 415 V To Mug Submersible Starter 240 Providing And Fitting Of Mu1 / Mu1h / Mu2 / Mu3 Contact Bridge 241 Providing And Fitting Of Mu1 / Mu2 Relay Extension Job To Mug Submersible Starter 242 Providing And Fitting Of Mu1 / M, U1h / Mu2 / Mu3housing To Mug Submersible Starter 243 Providingand Fitting Of New Mug After Removing Old Damaged Ones 244 Mug 6, 6-10 Amp Relay 245 Mug 6, 9-14 Amp Relay 246 Mug 10, 13-21 Amp Relay 247 Mug 10, 20-32 Amp Relay 248 Mug 10, 28-42 Amp Relay 249 Mug 15, 11-18 Amp Relay 250 Mug 15, 13-22 Amp Relay 251 Mug 20, 9-14 Amp Relay 252 Mug 20H, 20-32 Amp Relay 253 Mug 20H, 28-42 Amp Relay 254 Mug 30, 20-33 Amp Relay 255 Mug 30, 30-50 Amp Relay 256 Mug 40, 30-50 Amp Relay 257 Mug 40, 36-60 Amp Relay 258 Mug 50, 36-50 Amp Relay 259 Mug 50, 45-75 Amp Relay 260 Mug 75, 45-75 Amp Relay 261 Mug 75, 66-110 Amp Relay 262 Mccbproviding And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 36Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 263 Upto And Including 100A ( Ics= 50% Icu ) 264 125A 265 160A 266 200A 267 250A 268 400A 269 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 270 125A 271 160A 272 200A 273 250A 274 400A 275 630A 276 Providing Of Set Of Spreader Terminals For Above 3-Pole Mccbs 277 100A 278 125A 279 250A 280 400A 281 630A 282 Providing And Fitting Of 4-Pole 415V Mccb With Thermal Magnetic Release Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Similar ) Having Max. Of Thermal Release Range As Under: 283 125A 284 160A 285 200A 286 250A 287 400A 288 630A 289 Spares For Acb ( L&T C-Power ) Providing And Fitting Of Pole Assembly For Draw Out Type Acb ( L&T C-Power ) 290 Upto 1250A 291 2000A 292 Providing And Fitting Of Arc Chute ( 440V ) For Acb ( L&T C-Power ) 293 Upto 1250A 294 1600 - 2000A 295 Providing And Fitting Of Jaw Contact For Acb ( L&T C-Power ) 296 630-1000A 297 1250A 298 1600A / 2000A 299 Providing And Fitting Of Fixed Arcing Contact For Acb ( L&T C-Power ) 300 800- 1600A 301 2000A 302 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 303 800- 2000A 304 Providing And Fitting Of Shunt Release For Acb ( L&T C-Power ) 305 Providing And Fitting Of Under Voltage Release For Acb ( L&T C-Power ) 306 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 307 Providing And Fitting Of Terminal Adaptor For Draw Out L&T C-Power Acb Of Ratings As Under: 308 Upto 800 - 1250A 309 1600 - 2000A 310 Providing And Fitting Of Thermal-Magnetic Release ( Type Dn1 ) For L&T C-Power Acb 311 Providing And Fitting Of Ct For Dn1 Type L&T C-Power Acb 312 800 / 1000A 313 1250 / 1600A 314 2000A 315 Providing And Fitting Of Main Spring For 3-Pole Acb ( L&T C-Power ) 316 800- 1600A 317 2000A 318 Providing Of Racking Handle For Draw-Out Type Acbs ( L&T C-Power ) Rating Upto 2000A 319 Providing And Replacement Of Spring Charging Motor ( Ac / Dc ) 320 Providing And Replacement Of Motor Limit Switch 321 Instrumentation And Panel Accessoriesproviding And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 322 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 323 48X48mm 500V Voltmeter 324 96X96mm 500V Voltmeter 325 144X144mm 500V Voltmeter 326 96X96mm Ammeter ( 5A Ct Operated ) 327 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 328 Providing And Fitting Of 10A Line Current Ammeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 329 Providing And Fitting Of 10A Voltmeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 330 Providing And Fitting Of Tape Insulated Ring Type Metering Current Transformers ( Ae / Rishabh / Crompton / Kilburn ) As Under: 331 100 / 5A Or 150 / 5A - Class 1 - Burden 5Va 332 200 / 5A - Class 1 - Burden 10Va 333 400 / 5A - Class 1 - Burden 15Va 334 600 / 5A - Class 1 - Burden 15Va 335 800 / 5A - Class 1 - Burden 15Va 336 1000 / 5A - Class 1 - Burden 15Va 337 2000 / 5A - Class 1 - Burden 15Va 338 Extra For 1A Secondary Upto 600 / 1A Over Corresponding Rate 339 Providing And Fitting Of Analog Vac Hour Meter ( Make: L&T Or Equivalent Make ) 340 Din Mounting Type 341 Flush Mounting Type 342 Providing And Fitting Of Flush Or Projecting Head Push Button With Contact Block ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 343 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 344 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 345 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 346 50V Or Less Unbalance & 1 C / Odin Mounted 347 50V Or Less Unbalance & 1 C / Opanel Wall Mounted 348 70V Or Less Unbalance & 2 C / Odin Mounted 349 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 350 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 351 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 352 Providing And Fixing Upvc Panel Trunking With Cover 353 15X15mm 354 25X25mm 355 Terminals / Lugsproviding And Crimping Of Various Aluminium Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 356 16 Sq. Mm 357 25 Sq. Mm 358 35 Sq. Mm 359 50 Sq. Mm 360 70 Sq. Mm 361 95 Sq. Mm 362 120 Sq. Mm 363 150 Sq. Mm 364 185 Sq. Mm 365 225 Sq. Mm 366 240 Sq. Mm 367 300 Sq. Mm 368 Providing And Crimping Of Various Copper Tube Lugs ( Dowells / Action / Or Any Other Reputed Make ) With Tapping, Insulation As Under: 369 16 Sq. Mm 370 25 Sq. Mm 371 35 Sq. Mm 372 50 Sq. Mm 373 70 Sq. Mm 374 95 Sq. Mm 375 120 Sq. Mm 376 150 Sq. Mm 377 185 Sq. Mm 378 225 Sq. Mm 379 240 Sq. Mm 380 300 Sq. Mm 381 Cablesproviding And Fitting Of Pvc Insulated 1100V Flat 3-Core Industrial Copper Cable For Submersible Pump Motors ( Preferred Makes: Finolex / L&T / Havells / Kei / Polycab ) 382 1.5 Sqmm 383 2.5 Sqmm 384 4.0 Sqmm 385 6.0 Sqmm 386 10.0 Sqmm 387 16.0 Sqmm 388 25.0 Sqmm 389 35.0 Sqmm 390 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Armoured Industrial Copper Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 391 16.0 Sqmm 392 25 Sqmm 393 35 Sqmm 394 50 Sqmm 395 70 Sqmm 396 95 Sqmm 397 120 Sqmm 398 150 Sqmm 399 185 Sqmm 400 240 Sqmm 401 300 Sqmm 402 400 Sqmm 403 Providing And Fitting Of Xlpe Insulated, 1100V Single Core Industrial Armoured Aluminium Cable As Under ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 404 16 Sqmm 405 25 Sqmm 406 35 Sqmm 407 50 Sqmm 408 70 Sqmm 409 95 Sqmm 410 120 Sqmm 411 150 Sqmm 412 185 Sqmm 413 240 Sqmm 414 300 Sqmm 415 Providing And Fitting Of Xlpe Insulated, 1100V 3.5-Core Industrial Armoured Aluminium Cable As Per Is 7098 ( Preferred Make: Finolex / Gloster / Havells / Kei / Polycab ) 416 25 Sqmm 417 35 Sqmm 418 50 Sqmm 419 70 Sqmm 420 95 Sqmm 421 120 Sqmm 422 150 Sqmm 423 185 Sqmm 424 240 Sqmm 425 300 Sqmm 426 Wiringproviding And Fitting Of Pvc Insulated 1100V Flexible Copper Cable ( Frls ) For Electrical Installations As Under ( Preferred Makes: Finolex / Anchor / L&T / Havells / Kei / Polycab ) 427 1.0 Sqmm 428 1.5 Sqmm 429 2.5 Sqmm 430 4.0 Sqmm 431 6.0 Sqmm 432 10.0 Sqmm 433 16.0 Sqmm 434 2X1.5 Sqmm 435 2X2.5 Sqmm 436 2X6 Sqmm ( Aluminium Unarmoured ) 437 Conduits 438 Providing And Fixing 25Mm Pvc Round Conduit ( Medium ) With Allied Pvc Fittings 439 Providing And Fixing Upvc Trunking 25X16mm With Allied Fittings 440 Providing And Fixing Polypropylene Corrugated Flexible Conduit 441 25Mm 442 32Mm 443 Providing And Fitting Perforated Ms Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Ms Suspenders Or Fixing On Cantilever Supports And Including Painting Etc As Required. 444 100 X 50 X 1.6Mm 445 150 X 50 X 1.6Mm 446 Electrical Fitingsproviding And Fitting Of Various Electrical Fittings As Under ( Preferred Makes: Anchor / Ssk / Havells ) 447 Switch-6A-Sp-1Way, 240V, 50 Hz, Ac. 448 Switch-6A-Sp-2Way, 240V, 50 Hz, Ac. 449 Cord Switches:- Providing And Fitting Of Cord Switch-6A-Sp-1Way, 240V, 50 Hz, Ac / Hanging Bell Push. 450 Bell Push 240V, 50 Hz, Ac. 451 6A Socket:- Providing And Fitting Of6a-2 / 3 Pin-Universal Socket, 240V, 50 Hz, Ac. 452 Neon Indicator 453 Mini Telephone Jack 454 Fan Regulator ( Mini ) With Rotary Step 455 Fan Regulator ( Deluxe ) With Rotary Step 456 Shuttered-3 Pin Socket And Switch ( Box / Recessed ) - 20A-Sp-1 Way, 230V 50 Hz, Ac. 457 Plug Top 15 / 16A 3 Pin ( Isi Marked ) 458 32A Tp Switch 415V With Neon 459 32A Dp Switch 240V With Neon 460 Surface Mounting Box For Switches As Follows: 461 1 Gang Box 462 2 Gang Box 463 3 Gang Box 464 4 Gang Box 465 5 Gang Box 466 6 Gang Box 467 7 Gang Box 468 4 Gang Box ( Double Domestic ) 469 Providing, Fixing, Testing Of 6A Ceiling Rose 470 Providing And Installation Of Pendant / Angle / Batten Holders 6A 240V 471 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door ( Make: L&T / Legrand / Hager / Havells / Benlo ) 472 4 Way 473 8 Way 474 12 Way 475 16 Way 476 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads ( Preferred Make: L&T / Legrand / Hager / Havells / Schneider ) 477 6-32A Sp 478 40A Sp 479 6-32A Dp 480 40A Dp 481 100A 4P Isolator 482 Providing And Installation Of Change Over Switches Of Metal Enclosure 240V 50Hz ( Preferred Make: Anchor / Ssk / Havells / L&T ) 483 2-Pole 16A 415V 484 2-Pole 32A 415V 485 4-Pole 32A 415V 486 4-Pole 63A 415V 487 4-Pole 100A 415V 488 Providing And Installation Of Busbar Chamber 3-Ph 4 Bar Heavy Duty Copper Strips With Rating As Under ( Preferred Make: Havells / Ssk / L&T ) 489 63A 415V 490 100A 415V 491 200A 415V 492 Manpower 493 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 494 Hiring Charges Of Labourer For Support Of Electrician 495 Excavating Trenches Of Required Width For Pipes, Cables, Etc In All Kinds Of Soil Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M 496 Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 497 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 498 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm Dia 499 Pipes, Cables Etc. Exceeding 600 Mm Dia But Not Exceeding 1200 Mm Dia 500 Extra For Excavating Trenches For Pipes, Cables Etc. In All Kinds Of Soil For Depth Exceeding 1.5 M, But Not Exceeding 3M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre ) . 501 Extra For Excavating Trenches For Pipes, Cables, Etc, In All Kinds Of Soil For Depth Exceeding 3 M In Depth, But Not Exceeding 4.5 M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre. )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2023 Corrigendum Technical Bid 02-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 11000.0 /-
Tender Value
INR 5.50 Lakhs /-

BOQ Items

Name of Work:Fixing of rate contract for repairs/replacement to electrical equipments installed at different Water Supply Schemes of Jal Shakti (PHE) Mechanical Sub-Division Bijbehara (District Anantnag) for the financial year 2023-24.
Sl. No. Item Description
1Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under:
2Private car, auto-rickshaw or similar with 1.0 km lead
3Extra per kilometer for lead >1.0 kms upto 5.0 kms
4Extra per kilometer for lead >5.0 kms upto 10.0 kms
5Extra per kilometer for lead >10.0 kms upto 20.0 kms
6Extra per kilometer for lead >20.0 kms upto 30.0 kms
7Load carrier auto, mini van or similar with 1.0 km lead
8Extra per kilometer for lead >1.0 kms upto 5.0 kms
9Extra per kilometer for lead >5.0 kms upto 10.0 kms
10Extra per kilometer for lead >10.0 kms upto 20.0 kms
11Extra per kilometer for lead >20.0 kms upto 30.0 kms
12Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead
13Extra per kilometer for lead >1.0 kms upto 5.0 kms
14Extra per kilometer for lead >5.0 kms upto 10.0 kms
15Extra per kilometer for lead >10.0 kms upto 20.0 kms
16Extra per kilometer for lead >20.0 kms upto 30.0 kms
17VOLTAGE STABILIZERS Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling.
18upto 50 kVA
19>50 upto 100kVA
20>100kVA upto 250 kVA
21Greater than 250 kVA
22Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil
23upto 50 kVA
24>50 upto 100kVA
25>100kVA upto 250 kVA
26Greater than 250 kVA
27Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank.
28>60 upto 200 HP
29Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL)
30Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc) (Process loss maximum of 5% allowed)
31Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates).
3210kVA rating
3330kVA rating
3450kVA rating
3575kVA rating
36100kVA rating
37150kVA rating
38175kVA rating
39200kVA rating
40250kVA rating
41Removing of damagedplate type voltage regulator switch from 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work
4210kVA rating
4330kVA rating
4450kVA rating
4575kVA rating
46100kVA rating
47150kVA rating
48175kVA rating
49200kVA rating
50250kVA rating
51Impregnation/heat treatment ofwinding assembly of 3 phase, 415 ±15 % Volt voltage stabilizerby way of keeping it in an electric oven for about 24 hours and at approperate temperature.
5210kVA rating
5330kVA rating
5450kVA rating
5575kVA rating
56100kVA rating
57150kVA rating
58175kVA rating
59200kVA rating
60250kVA rating
61Removing of damaged copper connection terminal bolt with washer and nut from3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer.
6210kVA rating
6330kVA rating
6450kVA rating
6575kVA rating
66100kVA rating
67150kVA rating
68175kVA rating
69200kVA rating
70250kVA rating
71500kVA rating
72Hiring of portable welding set /soldering equipment etc. excluding power charges
73Arresting of leakage in, 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubesby way of soldering/ welding at the cracked spot (average length of spot = 1 inch)
74Providing and replacement of copper contact points on regulator plate
75Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector)
76STARTER Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank.
77upto 60 HP rating
78>60 upto 200 HP
79>200 HP upto 350 HP
80greater than 350 HP
81Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter.
82upto 60 HP rating
83>60 upto 200 HP
84>200 HP upto 350 HP
85greater than 350 HP
86CONTACTORS Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage:
87L&T ML 1.5
88L&T ML 2
89L&T ML 3
90L&T ML 4
91L&T ML 6
92L&T ML 12
93L&T MNX 50
94L&T MNX 70
95L&T MNX 80
96L&T MNX 95
97L&T MNX 110
98L&T MNX 140
99L&T MNX 185
100L&T MNX 225
101L&T MNX 250
102MK1
103MK2
104MU1
105MU1H
106MU2
107MU3
108ML2W
109ML3W
110ML4W
111ML6W
112Schneider Electric LC1F265 (without coil)
113Schneider Electric LC1F330 (without coil)
114Schneider Electric LC1F400 (without coil)
115Schneider Electric LC1F630 (without coil)
11632A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider)
11745A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider)
118Providing and fitting of new AC coil with specified coil voltage for contactors:
1199A to 45A AC-3 rating (Siemens 3TF/ equivalent)
120L&T ML 2/ 3
121L&T ML 4/ 6
122L&T ML 10/ 12
123L&T MNX 50/ 70/ 80
124L&T MNX 95/ 110/ 140
125L&T MNX 185/ 225/ 250
126L&T MNX 300/ 400
127L&T MNX 550/ 650
128Schneider Electric LC1F185/ LC1F225
129Schneider Electric LC1F265/ LC1F330
130Schneider Electric LC1F400
131Schneider Electric LC1F630
132Providing and fitting of new Contact kit set for contactors
13332A AC-3 rating (Siemens 3TF/equivalent)
134L&T ML 2
135L&T ML 3
136L&T ML 4
137L&T ML 6
138L&T ML 10
139L&T ML 12
140Providing and fitting of auxillary contactors/ control relay
141L&T MX0 having 04 contacts (all combinations) for AC control
142L&T MX0 having 04 contacts (all combinations) for DC control
143L&T ML (1NO+1NC) side mounting auxillary contact block
144L&T MNX/MCX front mounting type having 04 contacts (all combinations)
145TIMING RELAYS Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make)
146Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) .
147(2NO + 2NC) double block; ON delay
148(2NO + 2NC) double block; ON & OFF delay
149Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent)
150(2NO + 2NC) contact block
151Magnetic coil 415V AC
152Magnet frame assembly without coil
153Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make)
154Star Delta (range from 3s - 120s)240V AC
155Star Delta (range from 3s - 30s)240 - 415V AC
156ON delay (0.3s - 30hrs) 240V AC
157THERMAL OVERLOAD RELAY Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2)
158Relay range in between 0.2A to 15A
15914-23A
16020-33A
16124-40A
162Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5)
16320-33A
16430-50A
16536-60A
16645-75A
16766-110A
168Providing, fitting and setting of thermal overload relay of specified relay range
169L&T ML1 (Relay range in between 0.15A to 16A)
170L&T ML2/3 (Relay ranges in between 9A to 42A)
171MISCELLANEOUS
172Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots
173Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement.
174Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement.
175OIL IMMERSED STARTER SPARES Providing and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP
176Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts), upto 40 HP
177Spares for oil immersed manual starters
178Fixed finger contact
179Moving tip contact
180No volt coil
181Moving drum contact (starters upto 40HP)
182Moving drum contact (starters > 40HP)
183Base plate Bakelite/ DMC (starters upto 40HP)
184Base plate Bakelite/ DMC (starters > 40HP)
185Steam carrier assembly (starters upto 40HP)
186Steam carrier assembly (starters > 40HP)
187Sequence shaft (starters upto 40HP)
188Sequence shaft (starters > 40HP)
189Bakelite tube for Sequence shaft (starters upto 40HP)
190Bakelite tube for Sequence shaft (starters > 40HP)
191Trip rod assembly (starters upto 40HP)
192Trip rod assembly (starters > 40HP)
193Lock lever
194Cam assembly
195Oil dashpot assembly
196Overload coil (set of 03 nos.) upto 20HP
197Overload coil (set of 03 nos.) 30- 40HP
198Overload coil (set of 03 nos.) 50- 60HP
199Overload coil (set of 03 nos.) 70- 80HP
200Overload coil (set of 03 nos.) 90- 100HP
201L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARES Volt-Ammeter 500V,
202Electronic Star-Delta Timer 3-30s
203Providing and fitting of Terminal Block
20460A - 3 way
205100A - 3 way
206Single phase preventing relay Sz5 type
207Single phase preventing relay SDz5 type
208Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T)
209MK1 (all ranges)
210MU1 (all ranges)
211MU2 relays of following ranges
2126 -10 A, 9 - 14A
21313 - 21A
21415 - 25A
21520 - 32A
21624 - 38A
21728 - 42A
218Providing and fitting of standard operating coil for following contactors
219MK1/ MK2
220MU1/ MU2/ MU3
221Providing and fitting of contact bridge without contact of following contactors
222MK1/ MK2
223MU1/ MU2/ MU3
224Providing and fitting of single moving contact of following contactors
225MK1
226MK2
227MU1
228MU2
229MU3
230Indicating lamps
231Rocker switch
232Rocker switch (MUG-G6 to MUG G20)
233Rocker switch (MUG-G30 to MUG G75)
234Voltage Selector switch
23530A Ammeter Spare for MR-G Controller
236Volt Ammeter (30A, 300V AC) for 3-30 sec or 12-20 sec.
237Electronic star -Delta timer for MUG Starters
238Electronic star -Delta timer type ST100, 160 - 500V, for 3-30 sec or 12-20 sec.
239Providing and fitting of MU Coil 240/360/415 V to MUG submersible Starter
240Providing and fitting of MU1/MU1H/MU2/MU3 contact bridge
241Providing and fitting of MU1/MU2 Relay extension job to MUG submersible starter
242Providing and fitting of MU1/M,U1H/MU2/MU3housing To MUG submersible starter
243Providingand fitting of New MUG after removing old damaged ones
244MUG 6, 6-10 Amp relay
245MUG 6, 9-14 Amp relay
246MUG 10, 13-21 Amp relay
247MUG 10, 20-32 Amp relay
248MUG 10, 28-42 Amp relay
249MUG 15, 11-18 Amp relay
250MUG 15, 13-22 Amp relay
251MUG 20, 9-14 Amp relay
252MUG 20H, 20-32 Amp relay
253MUG 20H, 28-42 Amp relay
254MUG 30, 20-33 Amp relay
255MUG 30, 30-50 Amp relay
256MUG 40, 30-50 Amp relay
257MUG 40, 36-60 Amp relay
258MUG 50,36-50 Amp relay
259MUG 50, 45-75 Amp relay
260MUG 75, 45-75 Amp relay
261MUG 75, 66-110 Amp relay
262MCCB Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under:
263upto and including 100A (Ics= 50% Icu)
264125A
265160A
266200A
267250A
268400A
269Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under:
270125A
271160A
272200A
273250A
274400A
275630A
276Providing of set of spreader terminals for above 3-pole MCCBs
277100A
278125A
279250A
280400A
281630A
282Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under:
283125A
284160A
285200A
286250A
287400A
288630A
289SPARES FOR ACB (L&T C-POWER) Providing and fitting of pole assembly for draw out type ACB (L&T C-power)
290upto 1250A
2912000A
292Providing and fitting of Arc Chute (440V) for ACB (L&T C-power)
293upto 1250A
2941600 - 2000A
295Providing and fitting of Jaw contact for ACB (L&T C-power)
296630-1000A
2971250A
2981600A/ 2000A
299Providing and fitting of Fixed arcing contact for ACB (L&T C-power)
300800- 1600A
3012000A
302Providing and fitting of Moving arcing contact for ACB (L&T C-power)
303800- 2000A
304Providing and fitting of Shunt release for ACB (L&T C-power)
305Providing and fitting of Under Voltage Release for ACB (L&T C-power)
306Providing and fitting of Moving arcing contact for ACB (L&T C-power)
307Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under:
308upto 800 - 1250A
3091600 - 2000A
310Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB
311Providing and fitting of CT for DN1 type L&T C-power ACB
312800/ 1000A
3131250/ 1600A
3142000A
315Providing and fitting of main spring for 3-pole ACB (L&T C-power)
316800- 1600A
3172000A
318Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A
319Providing and replacement of spring charging motor (AC/ DC)
320Providing and replacement of motor limit switch
321INSTRUMENTATION AND PANEL ACCESSORIES Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE)
322Providing and fitting of flush type analog moving iron AC meter as under: (Make: Rishabh/ AE/ C&S/ BCH)
32348x48mm 500V voltmeter
32496x96mm 500V voltmeter
325144x144mm 500V voltmeter
32696x96mm ammeter (5A CT operated)
327Providing and fitting of flush type frequency meter with range 45-55Hz: (Make: Rishabh/ AE/ L&T/ Schneider/ BCH)
328Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic)
329Providing and fitting of 10A voltmeter selector switch with OFF (Make: L&T/ Rishabh/ AE/ Teknic)
330Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under:
331100/5A or 150/5A - Class 1 - Burden 5VA
332200/5A - Class 1 - Burden 10VA
333400/5A - Class 1 - Burden 15VA
334600/5A - Class 1 - Burden 15VA
335800/5A - Class 1 - Burden 15VA
3361000/5A - Class 1 - Burden 15VA
3372000/5A - Class 1 - Burden 15VA
338Extra for 1A secondary upto 600/1A over corresponding rate
339Providing and fitting of analog VAC hour meter (Make: L&T or equivalent make)
340DIN mounting type
341Flush mounting type
342Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make)
343Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make)
344Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent)
345Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make)
34650V or less unbalance & 1 C/ODIN mounted
34750V or less unbalance & 1 C/OPanel wall mounted
34870V or less unbalance & 2 C/ODIN mounted
349Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make)
350Providing of HRC fuses (2A - 32A) ratings
351Providing and fitting of Fuse holders for fuses upto 32A rating
352Providing and fixing uPVC panel trunking with cover
35315x15mm
35425x25mm
355TERMINALS/LUGS Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:
35616 sq. mm
35725 sq. mm
35835 sq. mm
35950 sq. mm
36070 sq. mm
36195 sq. mm
362120 sq. mm
363150 sq. mm
364185 sq. mm
365225 sq. mm
366240 sq. mm
367300 sq. mm
368Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:
36916 sq. mm
37025 sq. mm
37135 sq. mm
37250 sq. mm
37370 sq. mm
37495 sq. mm
375120 sq. mm
376150 sq. mm
377185 sq. mm
378225 sq. mm
379240 sq. mm
380300 sq. mm
381CABLES Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab)
3821.5 sqmm
3832.5 sqmm
3844.0 sqmm
3856.0 sqmm
38610.0 sqmm
38716.0 sqmm
38825.0 sqmm
38935.0 sqmm
390Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)
39116.0 sqmm
39225 sqmm
39335 sqmm
39450 sqmm
39570 sqmm
39695 sqmm
397120 sqmm
398150 sqmm
399185 sqmm
400240 sqmm
401300 sqmm
402400 sqmm
403Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)
40416 sqmm
40525 sqmm
40635 sqmm
40750 sqmm
40870 sqmm
40995 sqmm
410120 sqmm
411150 sqmm
412185 sqmm
413240 sqmm
414300 sqmm
415Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)
41625 sqmm
41735 sqmm
41850 sqmm
41970 sqmm
42095 sqmm
421120 sqmm
422150 sqmm
423185 sqmm
424240 sqmm
425300 sqmm
426WIRING Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab)
4271.0 sqmm
4281.5 sqmm
4292.5 sqmm
4304.0 sqmm
4316.0 sqmm
43210.0 sqmm
43316.0 sqmm
4342x1.5 sqmm
4352x2.5 sqmm
4362x6 sqmm (Aluminium unarmoured)
437CONDUITS
438Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings
439Providing and fixing uPVC trunking 25x16mm with allied fittings
440Providing and fixing Polypropylene Corrugated flexible conduit
44125mm
44232mm
443Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required.
444100 x 50 x 1.6mm
445150 x 50 x 1.6mm
446ELECTRICAL FITINGS Providing and fitting of various electrical fittings as under (Preferred makes: Anchor/ SSK/ Havells)
447Switch-6A-SP-1way, 240V, 50 Hz, AC.
448Switch-6A-SP-2way, 240V, 50 Hz, AC.
449Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push.
450Bell push 240V, 50 Hz, AC.
4516A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC.
452Neon indicator
453Mini telephone jack
454Fan regulator (Mini) with rotary step
455Fan regulator (Deluxe) with rotary step
456Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC.
457Plug Top 15/16A 3 Pin (ISI Marked)
45832A TP switch 415V with neon
45932A DP switch 240V with neon
460Surface mounting box for switches as follows:
4611 Gang box
4622 Gang box
4633 Gang box
4644 Gang box
4655 Gang box
4666 Gang box
4677 Gang box
4684 Gang box (double domestic)
469Providing, Fixing, Testing of 6A ceiling rose
470Providing and installation of Pendant/ angle/ batten holders 6A 240V
471Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo)
4724 way
4738 way
47412 way
47516 way
476Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider)
4776-32A SP
47840A SP
4796-32A DP
48040A DP
481100A 4P isolator
482Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T)
4832-pole 16A 415V
4842-pole 32A 415V
4854-pole 32A 415V
4864-pole 63A 415V
4874-pole 100A 415V
488Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T)
48963A 415V
490100A 415V
491200A 415V
492MANPOWER
493Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works):
494Hiring charges of Labourer for support of electrician
495Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
496Pipes, cables etc, not exceeding 80 mm dia.
497Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
498Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia
499Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia
500Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre).
501Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.)