}

Tender For C.C.T.V. At Various Place In Municipality Ajitgarh, Installation Of Cameras (Providing, Fixing, Testing And Commissioning) Work, Sikar-Rajasthan

Department Of Local Bodies has published Tender For C.C.T.V. At Various Place In Municipality Ajitgarh, Installation Of Cameras (Providing, Fixing, Testing And Commissioning) Work. Submission Date for this Tender is 24-04-2023. CCTV System Tenders in Sikar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37303462
Tender For C.C.T.V. At Various Place In Municipality Ajitgarh, Installation Of Cameras (Providing, Fixing, Testing And Commissioning) Work
Tender
Indian
Rajasthan
Sikar
24-04-2023

Tender Details

Tender For C.C.T.V. At Various Place In Municipality Ajitgarh, Installation Of Cameras (Providing, Fixing, Testing And Commissioning) Work , Part-A , Supply, Drawing And Testing Of 4 Pair, 23Awg Solid Bare Copper Wire Insulated With Pvc, Utp ( Unshielded Twisted Pair ) , Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi / Tia / Eia-568, The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrschannel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms / Pvc Conduits / Casing Cappingincluding Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Supply, Drawing And Testing, Of Stranded Single Mode ( 9 / 125 ?M ) Glass Optic Fiber Cable, As Per Latest Ammendments Of Tia / Eia 568 / Iso / Iec 11801:2011 / Iec 60794-1-2, Construction Of Lszh Outer Sheath Cable, Cable Should Be Used For Lan And Wan Back Bones, With Its Lszh Sheathing These Cables Should Be Ideal For Indoor / Outdoor Installations In Existing Ms / Pvc / Hdpe Conduits / Slotted Channels With Ferruling At Both Ends For Identification Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr : A ) 6 Fiber , Supply, Installation, & Testing Of 19 1U Rack Mounted / Surface Mounted Aluminum / Crca 1.2Mm Powder Coated, Singlemode Glass Fiber Optic Cable Patch Panel / Liu Loaded With Flangless / Screwable Duplex Adapters For St / E-2000 / Sc / Lc / Mtrj / Pc Type, It Should Have Easy Removable Top Plate With Push Buttons, There Should Be A Splice Tray Installed In The Patch Panel / Liu Which Can Handle The Fiber Cores, Splice Tray Should Be Pc+Abs Material, It Should Include Accessories Like Mounting Hardware, Gormetts, Heat Shrink Tubes / Sleevs, Screws, Nuts To Install The Panel For Rack / Wallmount Applications As Per Requirment Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. , A ) 12 Ports , B ) 24 Ports , Supply, Installation, Otdr Testing & Fusion Splicing Of Fiber Singlemode Pigtail ( 9 / 125 ?M ) Made Of Glass Fiber Optic, Should Be Fitted At One End With Any One Type Of Single St / E-2000 / Sc / Lc / Mtrj / Pc Type Connector In Acc. With Iec 61754-20, As Per Latest Ammendments Of Tia / Eia 569 Standard Specification As Per Requirments Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr. , Supply, Installation, & Testing Of Indoor Duplex Multimode Patch Cord ( 50 / 125 ?M Made Of Glass Fiber Optic With Lszh Jacket, Multimode G652.D Mounted On Both Sides With St / E-2000 / Sc / Lc / Mt-Rj / Pc Type Duplex Connectors In Acc. With Iec 61754-20 As Per Latest Ammendments Of Tia / Eia 569B.3, As Per Requirements Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr. A ) 2 Mtr , Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6 / 6A Patch Cords Should Be Constructed Of Minimum 23 / 24 Awg, Stranded Bare Copper Cable With Frpvc / Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors As Per Ansi / Tia / Eia 568 Suitable For Cat 6 / 6A Application Complying To Latest Ammendments Category 6 / 6A Standards, According. To Tia568, Minimum Requirement For 1G Base-T / 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr : Cat 6, Utp ( Un-Sheilded Twisted Pair ) Patch Cord A ) 1 Mtr , Supply, Installation, Testing And Commissioning Of 1000 Base-Lx / Lh Single Mode / Multi Mode Fibre To 1000 Base-T Copper Giga Bit, Media Convertor Complete As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr. , Fiber Fusion Splicing With Otdr Testing Of Fiber Single / Multi Mode ( Per Splice ) Of Glass Fiber Optic Cable Including Cleaning The Cable And Making Splice As Per Standard Practice Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm., Conductorline Load Reversibility, Label Holding Facility, Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr : Single Pole Mcb A ) 6 A To 32 A Rating , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade. Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. A ) 2 X 2.5 Sq.Mm , Supply , Installation, Testing And Comissioning Of Floor Standing Iso 9001:2015 & 14001 Or Higher Level Certified Company Made Communication Enclosure ( Rack ) Of 600 Mm Depth With Made From Crca & Hot Dip Powder Coated, Vertical Mounting Rail 1.6 Mm With Umarking, Front Sturdy Sheet Steel Frame Folded From One Piece And Welded With 5Mm Toughened Glass Door, With All Round Protective Channel On The Door Aperture, Lock Integrated On Front Door, Top And Bottom Cover With Cable Entry Provision With Gland Plates, Integrated Side Walls, Accessories Like: 5 Nos Of 19 1U Horizontal Cable Manager, 2 Nos Of Vertical Cable Managers, 2 Nos Of 90 Cfm 230V Ac Fan With 1 Mts Long Cable, Mounting Hardware , 1 No Of 19 1U, Mountable Socket Strips With 6 Nos Of 5A Universal Sockets With 2 Mts Long Power Chord For Supplying Power To Switches, Fans Etc Along With Earth Continuity Kit, Indicator, Moulded Power Supply Cable Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr. A ) 22U Floor Standing Enclosure , Sitc Of 55 4K Resolution Or Better Led Tv With Remote Control And Wall Mount Unit / Floor Stand Complete With Making Connections Etc. As Required. , Supply Of 4Mp Anpr Bullet Camera: Automatic Number Plate Camera As Per Attached Tender Specification And Approved Makes With Junction Box And Mounting Accessories. , Supply Of 4Mp Long Focus Motorised Vf Bullet Camera: As Per Attached Tender Specification And Approved Makes With Junction Box And Mounting Accessories. , Supply Of 64 Ch Intelligent Video Survellance Server As Per Attached Tender Specification And Approved Makes. , Supply Of Survellance Grade Btb Sata Type Hdd As Per Tender Specifications And Approved Makes With Complete Mounting Accessories. , Suppl Of L2 Type 6 Part Gigabit Switch: 4 X Rj45 10 / 100 / 1000 Mbps ( Poe ) . 2 X Rj45 10 / 100 / 1000 Mbps ( Uplink ) , Switching Capacity: 14 Gbps Or Better, Mac Table Size 2K Or Better Standard Compliance Ieee802 3, Ieee802 3U, Ieee802 3Ab, Ieee802 3X, Power Consumption Port1 $ 50 W ( Hi-Poe ) , Port2-4 $30 W, Total$60 W, Plug And Play. No Configuration Required: 250M Long Distance Poe Transmission, Power Supply 48 V 57 V Dc:Operating Temperature -10 *C. As Per Tender Specification And Approved Makes With Complete Required Accessories. , Supply Of Joint Closure 12F, Mini Joint Enclosure Fiber Optical Tennination Box For 6 Fiber Cable With Ofc Splicing Tray / 1.2 Fiber Optical Splitter With Fiber Splitter Box. , Supply, Installation, Testing And Commissioning Of Managed Layer 2 Intelligent Giga Ethernet Switch Providing 24 X 10 / 100 / 1000 Mbps Giga Ethernet Ports And With Min 4 Sfp Giga Ports ( Provision For Fiber Giga Connectivity ) With Provision Of Minimum Stacking Of 06 Switches With Related Lan Base Software Including Making Connections Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr. , Supply Of Outdoor Box For Ups, Switch, Ltu, And Other Fiber Accessories On Pole.

Key Value

Document Fees
INR 500 /-
EMD
INR 49900.0 /-
Tender Value
INR 24.95 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail