| 1 | Excavation of foundation in Hard soil within 50m initial lead and 1.5m initial lift |
| 2 | Filling Foundation and plinth with well graded sand including watering and ramming |
| 3 | Cement Concrete(1:4:8)with40 mm size Hard Granite Metal |
| 4 | 2.50cm thick A.S.flooring with cement concrete(1:2:4) with 12mm size H.G.chips including cement punning |
| 5 | Brick Work with Fly Ash Bricks in C.M. (1: 6) in foundation and plinth works |
| 6 | Brick Work with Fly Ash Bricks having crushing strength 75kg/sq.cm in cement mortar (1:6) in Super Structure |
| 7 | RCC Work M-20 grade with 20 mm and down grade HG chips (CB) including hoisting,lowering & laying concrete and compacting |
| 8 | Plinth Band and Column Base |
| 9 | Column and Beam |
| 10 | Lintel |
| 11 | Chajja |
| 12 | Roof |
| 13 | Straightening,Bending,Binding of M.S.Rod including cost of rod,Binding wire and transportation |
| 14 | Filling Foundation and plinth with Excavated Earth |
| 15 | 16mm thick cement plaster in C.M(1:6)over brick work |
| 16 | 12 mm thick cement plastering C.M. (1: 6) |
| 17 | 6mm thick cement plaster in C.M(1:4)R CC surfaces |
| 18 | Cement washing two coats on plastered surface |
| 19 | Finishingwallswith water proofing cement paint of approved shade2 coats |
| 20 | Supplying of MS Doors of windows |
| 21 | Priming one coat with any approved red oxide over steel work. |
| 22 | Painting 2coats with any approved iron paint on new iron work. |
| 23 | 20mm thick cement plaster in C.M(1:4) as grading Plaster |
| 24 | Cost of RCC Ring with cover of 1.2m dia 5 nos icluding fitting and fixing for spetic Tank |
| 25 | Recessed wiring to light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T / Anchor / Havels / V Guard |
| 26 | a) Short point |
| 27 | b) Medium Point |
| 28 | Recessed wiring to fan point / exhaust fan pointwith 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection Medium Point |
| 29 | Recessed wiring to 3pin 5 Amp plug point insingle core multi strand copper wire on Existing board |
| 30 | Supplying and fixing in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3pin 15 / 16 amps socket outlet and 15 / 16 amps piano type switch, connection, painting etc as required.(For light plugs to be used in non residential buildings |
| 31 | Recessed wiring to submain in different sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with FR PVC insulated single core multistrand copper conductor as earth wire as equired |
| 32 | b) 2 x 2.5 mm² |
| 33 | Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required |
| 34 | Supply and fitting of electronic fan regulator |
| 35 | Supply and fitting of 32A ICDP main switch on M.S box. |
| 36 | Supply and fitting of 6 mm2 PVC twin core Aluminium wire with G.I wire for service connection |
| 37 | Laying of 110mm nominal diameter UPVC sewer line includingcost of materials. |
| 38 | Providing & Fixing to walls/floor the following nominal diameter pipe, fittings including cost of pipe, making good the damage, etc. |
| 39 | 25mm dia PVC pipe in ground floor |
| 40 | 20mm dia PVC pipe in ground floor |
| 41 | 15mm dia PVC pipe in ground floor |
| 42 | Cutting the G.I./Black iron pipes and inserting a fitting 15mm to 25mm |
| 43 | Cutting grooves in pucca floor and walls for taking G.I/PVC pipe and making good the damage |
| 44 | in ground floor |
| 45 | Cutting holes through the brick or laterite masonary wall for taking G.I/PVC pipe and making good the damage in ground floor |
| 46 | Cutting holes through the brick or laterite masonary wall for taking S.C./PVC Soil waste pipeand making good the damage in ground floor |
| 47 | Supply, fitting and fixing ofCP concealed screw down stop cock of 15mm diameter in ground floor |
| 48 | Supply, fitting and fixing ofC.P. screw down bib cock (tap) of 15mm diameter in ground floor |
| 49 | Supply, fitting and fixing of wash hand basin with hole (size 550x400mm)including fixing CP brass waste, fixing of 32mm PVC waste pipe, fixing 15mm dia CP pillar cocks, fixing 12mm dia connection pipe & water connection etc. complete including cost of all materials in ground floor and first floor as per specification and direction of engineer in charge. |
| 50 | Fitting and fixing of Orissa type water closet squatting pan, Size 580x440mm in CC(1:5:10)using 40mm size cbhg metal including cost of materials in ground floor and first floor as per specification and direction of engineer in charge as per specification and direction of engineer in charge. |