Tender For Annual Maintenance Of New Academic Building, Amphitheatre, Instructional Building,Nf-I, Nf-Ii & Nf-Iii, B,C Quarter Buildings, Pgpex Mess & Garage Building, And Flats In Genexx Valley., calcutta-West Bengal

Indian Institute Of Management-IIMA has published Tender For Annual Maintenance Of New Academic Building, Amphitheatre, Instructional Building,Nf-I, Nf-Ii & Nf-Iii, B,C Quarter Buildings, Pgpex Mess & Garage Building, And Flats In Genexx Valley.. Submission Date for this Tender is 26-04-2023. Building Work Tenders in calcutta West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37239712
Tender For Annual Maintenance Of New Academic Building, Amphitheatre, Instructional Building,Nf-I, Nf-Ii & Nf-Iii, B,C Quarter Buildings, Pgpex Mess & Garage Building, And Flats In Genexx Valley.
Open Tender
Indian
West Bengal
calcutta
26-04-2023

Tender Details

Annual Maintenance Of New Academic Building, Amphitheatre, Instructional Building, Nf-I, Nf-Ii & Nf-Iii, B, C Quarter Buildings, Pgpex Mess & Garage Building, And Flats In Genexx Valley.

Key Value

Document Fees
INR 1500 /-
EMD
INR 81730.0 /-
Tender Value
INR 40.86 Lakhs /-

BOQ Items

Name of Work: Annual maintenance of New Academic Building, Amphitheatre, Instructional Building,NF-I, NF-II & NF-III, B,C quarter Buildings, PGPEX Mess & Garage Building, and flats in Genexx Valley.
Sl. No. Item Description
1BUILDING SCHEDULE ITEMS
2Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
3Earthworkinexcavationoffoundationtrenchesor drains,inallsortsofsoil(includingmixedsoilbut excludinglateriteorsandstone)includingremoving, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
4Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc.layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation.
5Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
6Fillinginfoundationorplinthbysilversandin layers not exceeding 150 mm as directed and consolidatingthesamebythoroughsaturationwith water, ramming complete including the cost of supply ofsand.(paymenttobemadeonmeasurementof finished quantity)
7Dismantling all types of masonry excepting cement concrete plain or reinforced, stackingserviceable materials at site and removing rubbish as directed. within a lead of 75 m. In all floor including roof.
8Dismantlingalltypesofplaincementconcrete works,stackingserviceablematerialsatsiteand removingrubbish asdirected withina leadof 75m. In all floor including roof. upto 150 mm. thick
9Dismantling all types of masonry excepting cement concrete plain or reinforced, stackingserviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In all floor including roof.
10Dismantlingalltypesofplaincementconcrete works,stackingserviceablematerialsatsiteand removingrubbish asdirected withina leadof 75m. In all floor including roof. (a) upto 150 mm. thick
11Dismantling R.C. floor, roof, beams etc. including cuttingrodsandremovingrubbishasdirected within a lead of 75 m. including stackingof steel bars. (a) In all floor including roof.
12Strippingoffwornoutplasterandrakingout joints of walls, celings etc. upto any height and in anyfloorincludingremovingrubbishwithina lead of 75m as directed.
13Removalofrubbish, earthetc.fromtheworking siteanddisposalofthe samebeyondthe compound,inconformitywiththeMunicipal/ Corporation Rules for such disposal, loading into truckandcleaningthesiteinallrespectasper direction of Engineer in charge
14SingleBrickFlatSolingofpickedjhamabricksincludingrammingand dressing bed to proper level and filling joints withlocal sand.
15Labour for laying single brick flat soling including ramming and dressing bed to proper level and filling joints with powdered earth.
16Brick-on-edgefloororpavementwith1stclassbricksetcloseincement mortar(1:6)andlaidwithcushionofsandbelow(includingcostthereof) including ruled or flush pointing with cement mortar (1:4) on top.
17Brick work with 1st class bricks in cement mortar (1:4). In foundation and plinth
18Brick work with 1st class bricks in cement mortar (1:4) (a)In superstructure, all floor
19125mm.thickbrickworkwith1stclassbricksincementmortar(1:4)in all floor.
20Makingonesetofscaffoldingonlyforreplacingglasspanels,painting, uprooting plant and another repairing works of building and S&P works for externalworks onlywith10cm.diabambooasmainposts attherateof1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-in- charge. (This item shouldbeexecutedonlyafterpriorapprovaloftheEngineer-in- charge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary furtherafter twentytimes oftotaluse,another onenumber newand labour rate for shifting to be considered accordingly. a) 3.90 metre height
21b) Extra for additional 3.6 height or part thereof
22OrdinaryCementconcrete(mix1:2:4)withgradedstonechips(20mm nominal size) excluding shuttering and reinforcement,ifany, in all floor as per relevant IS codes. a) Pakur Variety
23OrdinaryCementconcrete(mix1:1.5:3)withgradedstonechips(20mm nominal size) excluding shuttering and reinforcement,ifany, in all floor as per relevant IS codes. a) Pakur Variety
24Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thicknesswithrequiredbracingforconcreteslabs,beamsandcolumns, lintelscurvedorstraightincludingfitting,fixingandstrikingoutafter completion of works (upto roof of all floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
25(e) Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m)
26Reinforcement for reinforced concrete work inall sorts of structures includingdistributionbars,stirrups,bindersetcinitialstraighteningand removal of loose rust (if necessary), cutting to requisite length, hooking and bendingtocorrectshape,placinginproperpositionandbindingwith16 gaugeblackannealedwireateveryintersection,completeasperdrawing and direction. (a) For works in foundation and upto roof of all floor/upto 4 m I.SAIL/ TATA/RINL
27(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer"s specification [Cement to be supplied by the Department]
28(b)Applying2coatsofNon-ToxicAcrylicPolymermodifiedPainthaving adhesive&waterproofingpropertiesbymixinginproportion(1liquid:4 cementitious material)or asper manufacturer"sspecification forwater proofing layer in water tank etc. (No Departmental Cement is required)
29Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement.
30Artificial stone in floor, dado, staircase etc with cement concrete(1:2:4)withstonechips,laidinpanelsasdirected with topping made with ordinary or white cement (as necessary) andmarbledustinproportion(1:2)including smoothfinishingandroundingoffcornersincludingraking out joints or roughening of concrete surface andapplication ofcementslurrybeforeflooringworksusingcement@1.75 kg/sq.m all complete including all materials and labour. In all floor. 3mm.thicktopping(Highpolishinggrindingon thisitemis not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick (Addextra@1.5%foreachaddl.floorupto4thfloorand @1.75%foreachadditionalfloorabove4thfloorforitem No.5 and 6 of subhead A).
31Supplying, fitting and fixing Black Stone slab used in Kitchen slab,alcove,wardrobeetc.laidandjointedwithnecessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in all Floor. (a) Slab Thickness 20 to 25 mm (Add extrafor each addl, floor over the rate for item 22, 25, 26, 17, 20, 31, 32 & 15 of subhead A. (I) upto 4 th floor- Rs. 12/-per Sq.m II) above 4th floor -Rs. 16/- per Sq.m
3218mm.to22mm.thick,kotastoneslabsetin20mmthick (avg)cementmortar(1:4) infloor,stair&lobbyincluding pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work.[Slurryfor bedding@4.4kg/Sq.m andpointing@2.0 kg/Sq.m]
33Extracostoflabour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
34Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps.
35Grinding to marble / mosaic floor including remaining stone, ifnecessary,aftercuttingwithmanuallabour/machine, where necessary
36Supplying, fitting and fixing Marble Slab/tile of 15to 18 mm thickness infloor,lobby, stair,landing& treads etc.over 20 mm(av.)thckbaseofCementmortar(1:2)laidwithwhite cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigmentsincludinggrindingandGranitepolishingasper direction of Engineering -in -Charge in all Floor. {White cement and Pigment to be supplied by the Agency] (a)WithMakrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana (i) AreaofeachSlab/tileexceeding0.60sq.mbutnot exceeding 1.00 sq.m.
37Supplying, fitting & fixing granite tiles 10mm to12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2)includingmakingsuitablearrangementstoholdthe stones properly by brass / copper hooks including pointing in cementmortar(1:2)(1whitecement:2marbledust)with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Usingcementslurryatbacksideoftiles@4.4kg/sq.m& white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each slab upto 0.2 Sq.m
38Supplying,fitting&fixing1stqualityCeramictilesinwalls andfloorstomatchwiththeexistingwork&4nos.ofkey stones(10mm)fixedwitharalditeatthebackofeachtile& finishingthejointswithwhitecementmixedwithcolouring oxide if required to match the colour of tiles including rougheningofconcretesurface,ifnecessaryorbysynthetic adhesive & grout materials etc. (A) Floor WithSandCementMortar(1:4) 20mmthick& 2mmthick cementslurryatbacksideoftilesusingcement@2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above0.09 Sq.m (ii) Other than Coloured decorative including white
39(B) Wall WithSandCementMortar(1:3) 15mmthick& 2mmthick cementslurryatbacksideoftilesusingcement@2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including white
40Supplyingandlayingtruetolineandlevelvitrifiedtilesof approvedbrand(size notless than 600 mm X600 mmX 10 mmthick)infloor,skirtingetc.setin20mmsandcement mortar (1:4) and 2 mm thick cementslurry back side of tiles usingcement@2.91Kg./sqMorusingpolymerisedadhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after applicationslurryusing1.75KgofcementpersqMbelow mortaronly,jointsgroutedwithadmixtureofwhitecement andcolouringpigmenttomatchwithcolouroftiles/epoxy grout materials of approved make as directed and removal of waxcoatingoftopsurfaceoftileswithwarmwaterand polishing the tiles using softand dry cloth uptomirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer"s specificationanddirectionofEngineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor (I)Withapplicationslurry@1.75kg/Sq.m,20mmsand cement mortar (1:4) & 2 mm thick cement slurry at back side oftiles,0.2kg/Sq.mwhitecementforjointfillingwith pigment. (A) Deep Colour & White
41Supplyingandlayingchequeredtilesofanyshade&of approved quality with (1:1½:3) cement concrete laid in panels orpatternsasdirectedinpavement,footpathetc.including necessaryunderlay25mmthick[avg]cementmortar(1:3) complete in all respectwith alllabour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (i) 25 mm. thick
42Supplying&laying20mmdesignerchequeredtilesofany shade andofapprovedquality as per IS:1237:1980laidin patterns as directed in pavement, footpath including necessary underlay25 mm thick average cementmortar(1:3) complete inallrespectwithalllabourandmaterials[usingcement slurry @ 4.4 kg/Sq.m at back side of tiles.
43Supplying & layingas per IRC-SP:063-2004 paver unit of any shadeofapprovedqualityasperrelevantIScode,laidin patternasdirectedinpavement,footpath,driveway(paver block only),etc includingnecessaryunderlay completeinall respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. a)50 mm thick Tiles as per IS: 1237-2012 for footpath, ramp, staircaseofpublicbuilding (over25mmthick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block.
44B) Supplying & laying of approved make and brand of scratch proof, flexible & homogeneousP.V.C.Vinyle flooring conformingtoIS:3462-1982inrequiredfinish,fixedwith synthetic acrylic adhesive after preparing the floor, levelling & smothaningwhennecessarywithsuitableputty,asperthe design & instruction of the Engineer-in-charge. (i) 2 mm thick (Plain)
45Polishing only of old marble or terrazo work with oxalic acid powderusing33gms/sq.m.bymanuallabour/machine where necessary.
46TakingoutMirzapurorglazedporcelaintilescarefullyby chisellingfromwallsorfloorincludingstackingserviceable material as directed.
47Washingandcleaningwithsoapwaterandrubbingwithoil cloth in all types of floor and dado.
48Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor) (i) In Roof:- a) With 0.60 mm thick sheet
49b) With 0.63 mm thick sheet
50c) With 0.80 mm thick sheet
51Supplying, fitting& fixing Zn-Alalloy (55% Al & 45% Zn) coatingof150gramspersq.metre(followedbycolour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted andfixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia& 3mm th.washer etc.complete with150mmendlap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet
52Aluminiumsheetridgingfittedwith selftappingscrews, EPDM washers etc complete.(Minimum 225mm end lapping). (A) 300 mm lapping each way (a) With 0.71 mm sheet
53Supplying and laying standard four course bituminous water proofing treatment as per specification laid down in I.S. 1346 - 1991 to be finished with pea size gravel including necessary preparatory works such as shaping mouth of outlets, cutting as and where necessary and refilling with sand and Cement mortar (4:1)or CementConcrete (1:2:4)withgraded stone chipsbeforeundertakingthetreatment including cutting groovesinparapetandinsertingedgeoffeltandmending gooddamagecompleteinallrespectasperdirectionof Engineer-in-Chargeincludingcostofallmaterialsand laboursandincidentalchargesbutexcludingthecostof Cement Mortar or concrete required for levelling and grading. (In sloped roof Course sand of approved varieties is tobeusedinplaceofPeasizegravelsasfourthandfinal course.) i) 1st and 3rd Course with bonding materials of hot applied industrial blown typebitumen of grade85/25 or90/15 conforming to I.S.702 - 1988 @ 12Kg/10Sqm on each layer. A. Over Flat Roof.
54Supplying&laying 3mmthickpre-fabricatedplastomeric waterproofingmembraneconformingtoEN12311-1& ASTMD5147,manufacturedwith atacticpolypropylene (APP) modified premium grade asphalt , specially reinforced withnon-wovenpolyestercorewithpolyesterreinforcement @160 gmsper sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat ofprimer @0.40lit/sqmofmanufacturer"sspecificationon smooth,cleandrysurfacepreparedwhereverrequired.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transversedirectionandfusedusingLPG/Propanetorch employing extra care ensuring full bondage, complete removal of entrapped air and sealingedges into grooves in appropriate manneras per direction of Engineer -in-charge all complete includingmaterials,labour andapplicable taxes.(Paymentshallbemadeonthebasisoffinished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse)
55Takingoutolddamagedtarfeltfromtheroof,parapetetc. preparingtheroofsurfaces byremovingallspoils,blisters, mossetc.fromtheworkingsiteanddisposalofthesame beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge.
56RepairstocracksinterracedroofbycuttingV-grooves75 mm.to100mm.deepand150mm.to200mm.wideand fillingthe same withbeatenlime concrete (2:2:7)withlime putty / paste and finishing complete (2 lime putty / paste : 2 surki : 7 brick khoa )
57M.S.structuralworkswithhollowsections(squareorrectangular shape)conformingtoIS:806-1968& IS:1161-1998)connectedto oneanotherwithbracket,gusset,cleatasperdesign,drawing& direction of Engineer-in-Charge complete including cutting to requisiteshape&size,fabricationincludingmetalarcwelding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumablessuchaselectrodes,gasandhirechargesofalltools andplantsandlabourreqiredforexecutionandallincidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrsofMSHolowSectionasspecifiedinreleventIScodein finishedwork.Paymentforgusset,bracket,cleatmaybemadeby addingtheactualweightofsuchitemswithweightoffinished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the all. Add 1.5 % extra over the rate foreachadditionalflooror4m.beyondtheinitial8m.orpart thereof. i) For roof truss works a) Span up to 12 Mtr
58(a) M.S.or W.I. Ornamental grill of approved design joints continuouslyweldedwithM.S,W.I.Flatsandbarsofwindows, railing etc. fitted and fixed with necessary screws and lugs in all floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i)Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
59Collapsible gate with40mm x 40mm x 6mm Tee as topand bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mmx5mmM.S.flats ascollapsible bracings properly rivetted and washered including 38mm steel rollersincludinglockingarrangements,fittedandfixedinposition withlugs setincementconcreteandincludingcuttingnecessary holes,chasingetc.inwalls,floorsetc.andmakinggooddamages complete. In all floor.
60Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolledsteelsectionsconformingtoIS7452-1974withnon-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handleplateetc,includinghoistinginposition,straighteningif required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mmdowncuttingholesandmendinggooddamagestomatchwith existing surface complete in all respect excluding glazing. Without integrated grills. (a) Fixed type steel windows as per IS sizes with horizontal glazing bars.
61(b) Openable steelwindowsasperISsizeswithside hung shutters andhorizotal glazingbars. [Theextra rateadmissible forthe openable portion only]
62(c ) Extra over item no. 33 (a) and (b) for, (i)FixedtypeventilatorsasperI.S.sizeswithhorizontalglazing bars height being limited to 580 mm.
63(iv) Two point nose steel handle including fitting and fixing.
64(vi)steel peg stay 300 mm long including fitting and fixing.
65(viii)M.S.integratedgrillasperapproveddesignintegratedwith steel window or ventilator, joints continuously welded with M.S. flats and bars.
66Welding in M.S. structural work with gas or electric: (b) Continuous weld.
67Renewingbottomrailortoprunnersofcollapsiblegateincluding mending good all damages.
68Takingoutheavyirongrateddoororwindow(jailpatternor existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.[Mending charges to be paid separately]
69Reparingcollapsiblegate by cuttingoutallrivetsasnecessary re- assambling all members including welding pieces of channels, sraighteningbentbarsandrivettingwithnewrivetsandfittingin position and painting two coats.
70Easing and oiling, cleaning collapsible gate and repairing to locking arrangements.
71Renewinghingeofsteelshutterincludingtakingoutoldoneby cutting and fixing new hinges by welding and mending good damages complete.
72Woodworkindoorandwindowframefittedandfixedinpositioncomplete includingaprotectivecoatofpaintingatthecontactsurfaceoftheframe exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : LocalSishu, Gamar,
73Supplying, Fitting& FixingFactorymade P.V.C.door frameof size50mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical memberand minimum 2 Nosfor horizontal member etc. complete as per Manufacturer?s specification and direction of Engineer-in-Charge.
74B. DOOR WINDOW SHUTTER Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In all floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu,Gamar, Champ,Badam,Bhola, Mogra, Hallak.
75Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways inordertomakethedoorofsolidcoreandinternallippingwithGarjanor similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting,fixingshuttersinpositionbutexcludingthecostofhingesandother fittings in all floor. (a) 35 mm thick shutters (single leaf)
76Supplying, fitting, Fixing Fly / Mosquito proof nylon net on any type of window, doorshutter frame with necessary fixing arrangements complete.
77Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
78Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm).
79Ironbutthingesofapprovedqualityfittedandfixedwithsteelscrews,withISI mark. (i)100mm. X 58mm. X 1.90mm.
80i)Ironhaspboltofapprovedqualityfittedandfixedcomplete(oxidised)with 16mm dia rod with centre bolt and round fitting. (a) 250mm long
81ii) Brass haspbolt of approvedquality fittedandfixed complete(oxidised) with 16mm dia rod with centre bolt and round fitting.(a) 250mm long
82(a) Supplying "Godrej" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
83(b) Supplying "Godrej" morticelock chromium plated with keys 6 levers including fitting & fixing complete.
84Door stopper (brass)
85Door stopper (Anodised aluminium)
86ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
87(b) Medium type
88(A)Irondoorringofapprovedqualityfittedandfixedwithnutandwasher complete. (i) 50mm dia.
89Anodisedaluminiumbarrel/tower/socketbolt(fullcovered)ofapproved manufacturedfromextrudedsectionconformingtoI.S.204/74fittedandfixed with cadmium plated screws: (iii) 100mm long x 10mm dia. bolt.
90(vii) 225mm long x 10mm dia. bolt.
91Anodised aliminium D-type handle of approved quality manufactured from extrudedsectionconformingtoI.S.specification(I.S.230/72)fittedandfixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (vi) 150 mm grip x 10 mm dia rod.
92(a) Metallic magic eye of approved quality fitted and fixed complete.
93(b)Supplying, fittingfixingGodrej type hydraulic (oilcheck)floordoor spring, heavy duty double action with brass shoe, brass top centre aluminium top cover etc. complete set as per direction of Engineer-in-charge.
94Supplying, fitting and fixing Godrej Multi Lock or equivallent .
95Taking out old iron higes and fitting, fixing the same with new steel screws. (e) 100mm. Long butt hinge.
96Renewingironmorticelock(localbestapprovedquality)6leverwithhandle, connected rods and keys consisting a complete set: (a) With chromium plated handle.
97Renewing mortice lock handle with connected rod: (a) With chromium plated.
98Repairs to automatic door closer including replacement of damaged main spring, oiling and adjusting as necessary including taking out and refitting the same.
99Labourfortakingoutdoorandwindowframeincludingshutterforrepairor replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) (a) Upto area 2.5Sq.m
100Takingoutshutterofdoorandwindow,dismantlingbyparts (forrepairor replacement of damaged parts) , reassembling and refitting and rehanging same witholdfittingsbutwithnewscrewsasnecessary. (Wheredifferentpartsof same shutter are renewed under different item, payment under item73will be made once only).
101Easing door and windows
102Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). (ii) 35mm Thick shutter. Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
103Panel (made of single plank) of door and window shutters to design as directed: (Payment to be made on area of exposed new work). (In case of non-supply of single plank penal rate of reduction to a maximum of 30% will be made). 19mm thick panel of 30cm to 45cm width Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
104ProvidingandfixingoffalseceilingwithpowdercoatedexposedG.I.grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid spandeflectionnot exceeding1/360spanwith hanger spacingof 1200mmc/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and WallAngle.TheWallAngleshallbefixedonPVCDashFastenersonthe perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I.wirefrompurlins/soffit.15mmthickOWAcousticBoard(MineralFiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value>0.65shouldbeplacedintheGridmoduletoformaFalseCeiling.All complete as per the drawing & directions of Engineer-in-charge. In all floor. a) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U- 1520).
105M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediatechannelof0.9mmthicksize45mmx15mmplacedat750mmc/c withG.I.ceilingangleofsize25mmx10mmx0.55mmthickfixedtotheceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50mmx26mmfixedtotheintermediatechannels withthe helpof connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound,papertapeandapplicationoftopcoatetc.asperthedirectionof Engineer-in-charge.(Therateincludesofcostofallmaterialsincludingtaxes, costofaccessories,fittingsandfixtures,scaffoldingandlabourchargesetc. complete) In all floor
106Supplying,fittingandfixingoffalseceilingframeworkwithpowdercoated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600mmlongandWallAngle.TheWallAngleshallbefixedonPVCDash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. TheMainRunnerstobeplaced@1200mm.TheCrossTee1200mmwillbe insertedinthe pre-cut slots of MainRunner at aregular intervalof 600mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6mmdiaG.I.wirefrompurlins/soffitallcompleteasperthedrawing& directions of Engineer-in-charge.
107Supplying,fittingandfixingboilingwaterresistantplyconformingtoIS:303- 1989bondedwithphenolformaldehydesyntheticresinofapprovedmakeand brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excludingthecostofsupportingframeworkandteakwood batten/Lipping] In all Floor (ii) 6mm
108(vi) 19mm
109Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as perapprovedmake,brand,finishandthicknesswithfitting,fixingthesameon Particle/MDF/ Ply Boards with recommended/ approvedadhesivewith proper clipping the sides for better attachment as per direction of Engineer-in- charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In all floor Glossy/Matt/Suede excluding surface texture or metallic lustre. (i) Thickness of laminate 1 mm
110Partition of teak veneer [1 mm] as per design fitted and fixed complete (excluding the supporting frame work & necessary teak wood battens): In all floor (i) 4mm thick commercial quality
111Plaster (to wall, floor, ceiling etc.) with sand and cement mortar includingroundingofforchamferingcornersasdirectedand rakingoutjointsincludingthroating,nosinganddripcourse, scaffolding/staging wherenecessary(allfloor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (a) 20 mm thick plaster
112Plaster (to wall, floor, ceiling etc.) with sand and cement mortar includingroundingofforchamferingcornersasdirectedand rakingoutjointsincludingthroating,nosinganddripcourse, scaffolding/staging wherenecessary(allfloor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (b) 15 mm thick plaster
113Labour for Chipping of concrete surface before taking up Plastering work.
114Closinggapbetweendoorandwindowframeandjambswith cementmortar(1:3)includingremovingoldmortar(throughout entiresurfaceofcontact)andcleaningthejoint.(Cement0.012 Cu.m/100 Mtr.) (This item is not payable for new works).
115Cementwashingincludingcleaningandsmootheningsurface thoroughly(cementtobeused@15kg./100sq.m.ofsurfaceforone coat and @25 kg./100 sq.m of surface for two coats): External surface (all floor) (a) One coat
116Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/Acrylicemulsionpaint includingscrapingandpreparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC.(In all Floor) (a) One Coat i) Water based interior grade Acrylic Primer
117Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/Acrylicemulsionpaint includingscrapingandpreparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC.(In all Floor) (a) One Coat ii)Solvent based interior grade Acrylic Primer
118Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorativetextured(mattfinish)orsmoothfinishacrylicexterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. In all Floor: One Coat
119Acrylic Distemperto interior wall, ceiling without acrylicprimer (asper manufacturer"sspecification) including cleaning and smoothning of surface. Two Coats
120Applying decorativecement basedpaint of approvedqualityafter preparingthe surfaceincludingscrapingthe same thoroughly (plastered or concrete surface) as per manufacturer"s specification. In all Floor: One Coat on new surface
121Protective and Decorative Acrylic exterior emulsion paint of approved quality,aspermanufacturer"sspecificationandasperdirectionof Engineer-in-Charge to be applied over acrylic primer as required. The rateincludescostofmaterial,labour,scaffoldingandallincidental charges but excluding the cost ofprimer. In all floor (Two Coat) a) Normal Acrylic Emulsion
122Protective and Decorative Acrylic exterior emulsion paint of approved quality,aspermanufacturer"sspecificationandasperdirectionof Engineer-in-Charge to be applied over acrylic primer as required. The rateincludescostofmaterial,labour,scaffoldingandallincidental charges but excluding the cost ofprimer. In all floor (Two Coat) b) Premium 100% Acrylic Emulsion
123Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitatingtheuseofscraper,wirebrushetc.(Paymentagainstthis item will be made only when this has been done on the specific direction of the Engineer-in-charge)
124Scraping and removing greasy soot from walls or ceiling of kitchen or similar smoke affected rooms and preparing the surface.
125RenderingtheSurfaceofwallsandceilingwithWhiteCementbase WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
126(a)Primingonecoat onsteelorothermetalsurfacewithsyntheticoil bound primer of approved quality including smoothening surfaces by sand papering etc.
127(b)Primingonecoatontimberorplastered surfacewithsyntheticoil bound primer of approved quality including smoothening surfaces by sand papering etc.
128(A)Paintingwithbestqualitysyntheticenamelpaintofapprovedmake and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: (a) On timber or plastered surface : With super gloss (hi-gloss) - (i) One coat (with any shade)
129(ii) Two coats (with any shade)
130With other than hi-gloss of approved quality- (i) One coat (with any shade)
131(ii) Two coats (with any shade)
132(b) On steel or other metal surface : With super gloss (hi-gloss) - (i) One coat (with any shade)
133(ii) Two coats (with any shade)
134(B) Painting with superior quality aluminium paint of approved make and brandincludingsmootheningsurfacebysandpaperingetc.onsteel surface : (a) One coat
135ApplyingAcrylicEmulsionPaintofapprovedmakeandbrandonwalls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
136Frenchpolishingtowoodworkincludingpreparingsurface(ordinary gloss) (b) On old French polished surface including complete removal of the old polish.
137(b)Renderingthesurfaceofwallsandceilingwithwhitecementbased wall putty of approved make and brand(1.5mm thick)
138(b)Washing&cleaningthewallsurface&ceilingbysoftdetergent powder & soft water & render the surface free of dust, stain etc.
139Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (i) 3 mm thick (weighing 7.4 kg/Sq.m)
140Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick
141Supplying best Indian figured glass viz. hammered, fluted, ribbed, pinhead etc. type including cutting to required sizes, setting on putty bases and fitted and fixed with nails and putty complete. (3 mm thick)
142Renewing worn out putty of glass panes : (a) Panes not exceeding 0.2 Sq.m
143Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (A)Glazed aluminium sliding windows made of extruded and annodized alloyaluminiumsectios,fabrications,includingcuttingtopropershape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketinginbetweenwindowframeandmasonrywork(walls,column, beam.lintelsetc.)aswellasbetweenglassandshutterframeforfixing glass and Polysulphide sealant and in between shutter and window frame wherenecessaryincludingcuttingtorequisitesizeand fixingglassas per drawing, specification and direction of EIC. Therateincludesthehirechargeofalltoolsandplants,includingall incidental charges, adhesive, joineries such as screw, cleat angle etc. but excludingthecostofextrudedaluminiumsections,glass,neoprene/ EPDM gasket, locking arrangement and rollers. i )2 track sliding window.
144ii )3 /4track sliding window.
145iii )Openable / Casement window.
146iv )Fixed glazing.
147v )Louvered window.
148Supplying heavy duty hydraulic double action floor spring along with top pin/setofpivotsconformingtoIS:6315oranyapprovedmakeasper direction of Engineer in charge.
149Supplying heavy duty top pin/set of pivots of local make and approved by the Engineer-in-charge.(This item to be provided where floor spring not used).
150SupplyingPVC rollers for sliding windows as per directionof Engineer in charge.
151Supplying maruti lock (100mm)
152Supplying EPDM gusket of approved make and brandas per direction of Engineer in charge. i)For sliding windows
153Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i)4mm thick clear glass.
154ii)4mm thick coloured / tinted / smoke glass.
155iii)5mm thick clear glass.
156iv)5mm thick coloured / tinted / smoke glass.
157Fillingthegapinbetweenaluminiumframe&adjacentRCC/Brick/ Stoneworkbyprovidingweathersiliconsealantover6mmdiabacker rodofapprovedqualityasperarchitecturaldrawingsanddirectionof Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width (a) all Floor
158Supplying,fitting & fixing of 2-Track / 3-TrackAluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983& IS1285-1975, annodised conformingtoIS1868-1983,fittedwithallotheraccessoriesviz.PVC roller,EPDM gasket, maruti lock, screwsetc.includinglabour charges forfitting&fixingofaluminium2-track/3-trackslidingwindowwith fixing of glass (excluding cost of glass)all complete as per architectural drawings anddirection of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
159Supplying, fitting & fixing of partly glazed partly panelled or fully glazed singleleafAluminiumswingdoorofallaluminiumsectionsvizdoor frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS:733-1983andIS:1285-1975,annodized conformingtoIS:1868- 1983,fittedwithallotheraccessoriesviz.EPDMgusket,cleat,angle screws etc.including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges,glass / Panel board all completeasperarchitecturaldrawingsanddirectionofEngineer-in- charge. (Excludingcostofglass/panelboard,doorspring/Alhinges,door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
160SupplyingWeatherSiliconesealantofapprovedmakeandbrandfor fixing of grove line between the Glasses as per direction of Engineer-in- charge. for Structural Glazing/Curtain wall. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work
161Supplying and laying true to line and levelAnti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tilesconforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tileswithSkidresistance>0.5,Mohr"shardness>5.0,Stainingresistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm inInternal area of buildinge.g. Toilet Block,Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4)and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backingcourse)laidafterapplicationslurryusing1.75 Kgof cementper Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). b)InallFloor:Sizes-600mmx600mmx10mmwithbreakingstrength> 1500 N
162PLUMBING & SANITARY SCHEDULE ITEMS
163Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above all. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (a) (i) 15 mm dia. medium quality
164(ii) 20 mm dia. medium quality
165(ii) 25 mm dia. medium quality
166(ii) 32 mm dia. medium quality
167(ii) 40 mm dia. medium quality
168(ii) 50 mm dia. medium quality
169Supplying, fitting and fixing shower of approved brand and make. (a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
170(iii) Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
171(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook (Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
172(g) PTMT overhead shower ( Prayag or equivalent) (i) 75 mm round
173Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (iv) 40 mm dia
174(vi) 32 mm dia
175(vii)25 mm dia
176(viii) 20 mm dia
177(ix) 15 mm dia
178Supplying, fitting and fixing bib cock or stop cock. (a)(i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
179(b)(i)ChromiumplatedStopCock(EquivalenttoCodeNo.513(A)& 513(B)&Model-Tropical/SumthingSpecialofESSCOorsimilar
180(ii)ChromiumplatedConcealedStopCock(EquivalenttoCodeNo. 514(A)&Model-Tropical/SumthingSpecialofESSCOorsimilar brand).
181(c) (i)ChromiumplatedBibCock(angularshapewithwallflange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand).
182(ii) Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand).
183(e)PTMT (Polytetra Bib Cock / Stop Cock( Prayag or equivalent) 15
184Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above all. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia) 15 mm
18520 mm
18625 mm
187Renewing brass spindle and valve of stop cock/bib cock/push cock/pillar (i) 15 mm
188Dismantling and refixing shower rose after cleaning.
189Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above all. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 (Dia) 15 mm
19020 mm
19125 mm
192Compact Compact Ball Valve with SS Handle For CPVC/ UPVC Fittings. (As per ASTM D 2467, Schedule 80) 15 mm
19320 mm
19425 mm
195Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
196Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity
197Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
198Supplying, fitting and fixing low-down cistern parts. (i) Internal fittings for cistern complete of approved make.
199(ii)Outlet Assembly
200(iii)Intlet Assembly
201(iv) Rubber Kid
202(v)Knob
203(vi)Brackets (pair)
204Renewing bolts and nuts for cistern.
205Renewing high pressure polythene ball cock of approved quality with polythene ball and aluminium lever complete for pipe of dia.: (i) 25 mm
206Renewing polythene ball of approved quality for pipe of dia.: (i) 25 mm
207Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (ii)550 mm X 400 mm size
208Supplying,fittingandfixingpedestalofapprovedmakeforwashbasin
209Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. (a) Plain edge sink with overflow (i) 610 mm X 450 mm X 200 mm
210Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm
211Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long
212Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iii) 900 mm long
213Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) (a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
214Supplying, fitting and fixing Waste fittings complete. (a) C.P. over brass (i) 32 mm
215Supplying, fitting and fixing C.I. bracket including two coats of painting. (a) Wash basin, Dental spitton
216Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
217a) (ii) CP Pillar Cock Super Deluxe with Aerator - 15 mm. (Equivalent to Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand)
218e) (i) CP Centre hole Basin mixture with regular spout without popup waste system with 450 mm long braided hoses. (Equivalent to Code No.5167(B) & Model - FLORENTINE of JAQUAR or similar brand).
219e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand)
220f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand).
221g) CP Sink Cock with Regular Swinging Spout (Table Mounted Model) (Equivalent to Code No. 5357 of JAQUAR or similar brand).
222Dismantling wash basin with brackets with or without waste fittings.
223Refixing wash basin with brackets with or without waste fittings.
224Dismantling sink with brackets with or without waste fittings.
225Refixing sink with brackets with or without waste fittings.
226Dismantling pillar cock of wash basin.
227Refixing pillar cock of wash basin.
228Cleaning wash basin/ sink with acid.
229Cleaning sink with soda and soap.
230Dismantling and taking out lead / polythene waste pipe and refixing the same after removing chokage including necessary bendings/ offsets and straightening and replacement of damaged parts, if any
231Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a)75 mm
232(b)110 mm
233(c) 160 mm
234Scraping the hard scum of "S" trap carefully to render the flushing flow easy after soaking with strong acid through W.C. pan on floor and also cleaning through flanged junction door underneath the ceiling including necessary scafolding and resetting the flanged door watertight by putty joints by methor labour.
235Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With "P" trap
236(a) With "S" trap
237Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding "P" or "S" trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mm
238Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete. (ii) 470 mm X 280 mm X 340 mm
239Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (ii)Plastic (hallow type) white
240Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe
241Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one
242Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (ii) 600 mm X 450 mm
243Supplying, fitting and fixing glass shelf with aluminium guard rails. (a) Ordinary type with 5.5 mm sheet glass (i) 450 mm X 125 mm
244Supplying, fitting and fixing liquid soap container. (c) Fibre glass
245Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent)
246Supplying, fitting and fixing PTMT Smart Shelf of approved make of size 300 mm.
247Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
248Dismantling E.P. or Anglo-Indian W.C.
249Refixing E.P. or Anglo-Indian W.C.
250Dismantling Orissapattern W.C. including taking out of base concrete, if necessary, complete.
251Refixing Orissa pattern W.C. Including cost of base concrete, if necessary,complete.
252Dismantling urinal.
253Refixing urinal.
254Dismantling flush pipe of water closet.
255Refixing flush pipe of water closet.
256Cleaning I.P.W.C. with acid.
257Cleaning E.P. or Anglo-Indian W.C. with acid.
258Cleaning urinal with channel with acid.
259Cleaning glazed tiles with acid.
260Removing chokage of water closet.
261Removing chokage of urinal and waste trap.
262Repairing C.P. hinges of W.C. seat.
263Repairing W.C. seat with brass plate and screws.
264Cleaning silt of inspection pit.
265Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. (a) Upto 30 users:- (ii) Beyond a lead of 150 metre and outside the Municipal limit
266(c) Upto 50 users:- (ii) Beyond a lead of 150 metre and outside the Municipal limit
267(e) Upto 100 users:- (ii) Beyond a lead of 150 metre and outside the Municipal limit
268(e) Upto 200 users:- (ii) Beyond a lead of 150 metre and outside the Municipal limit
269Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab
270Cleaning silt of master trap pit.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail