Tender For System Improvement Plan At Various Places Fed From 33/11 Kv Power Sub-Station Gagol-I And Mohiuddinpur In The Work Area Of ​​Subdivision I Baghpat Road And Subdivision Ii Paratapur Under Power Distribution Division I Meerut (Business Plan Year , Meerut-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For System Improvement Plan At Various Places Fed From 33/11 Kv Power Sub-Station Gagol-I And Mohiuddinpur In The Work Area Of ​​Subdivision I Baghpat Road And Subdivision Ii Paratapur Under Power Distribution Division I Meerut (Business Plan Year . Submission Date for this Tender is 12-04-2023. Bolts Tenders in Meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37143251
Tender For System Improvement Plan At Various Places Fed From 33/11 Kv Power Sub-Station Gagol-I And Mohiuddinpur In The Work Area Of ​​Subdivision I Baghpat Road And Subdivision Ii Paratapur Under Power Distribution Division I Meerut (Business Plan Year
Open Tender
Indian
Uttar Pradesh
Meerut
12-04-2023

Tender Details

System Improvement Plan At Various Places Fed From 33 / 11 Kv Power Sub-Station Gagol-I And Mohiuddinpur In The Work Area Of ​​Subdivision I Baghpat Road And Subdivision Ii Paratapur Under Power Distribution Division I Meerut ( Business Plan Year 2023-24 ) - 1 Cartage Of Following Material From Store Center Meerut To Je Store Including Loading & Unloading At Both Ends Maximum Distance Up To 30 Km. :- 2 Pcc Pole 8.5 Mtr Long / St Pole 11 Mtr Long 3 Lt Ab Cable 3X95+1X70+1X16 4 Lt Ab Cable 3X50+1X35+1X16 5 25 / 63 / 100 Kva T / F 6 3 Phase Lt Distribution Box 7 Acsr Weasal Conductor 8 Line Material As Such Stay Set, Pin Insulator, Disc Insulator, Earthing Rod, Gi Wire, Ms Angle, Ms Channel, Top Channel, Dropper Channel, Dead Clamp, Piercing Clamp Etc. 9 Cartage Of Following Material From Je, Store To Site Of Work Including Loading & Unloading At Both Ends Maximum Distance Up To 30 Km. :- 10 Pcc Pole 8.5 Mtr Long / St Pole 11 Mtr Long 11 Lt Ab Cable 3X95+1X70+1X16 12 Lt Ab Cable 3X50+1X35+1X16 13 25 / 63 / 100 Kva T / F 14 3 Phase Lt Distribution Box 15 Acsr Weasal Conductor 16 Line Material As Such Stay Set, Pin Insulator, Disc Insulator, Earthing Rod, Gi Wire, Ms Angle, Ms Channel, Top Channel, Dropper Channel, Dead Clamp, Piercing Clamp Etc. 17 Erection Of Pcc Pole 8.5 Mtr / St Pole 11 Mtr Long After Digging A Pit Of Size 1.6 Mtr Deep In All Type Of Soil Including Back Filling Of The Pole With Proper Ramming After Completion Of Work. 18 Erection Of Double Pole On Pcc Pole 8.5 / St Pole 11 Mtr Long After Digging A Pit Of Size1.6 Mtr Deep In All Type Of Soil For Each Pole Including Back Filling Of The Pole With Proper Ramming After Completion Of Work. 19 Erection Of Stay Rod Complete After Digging A Pit Of Size 1.6 Mtr Deep And Grouting The Same In Block Of Size 0.60 X 0.60 X 0.30 Mtr And Nuzzling At The Both Ends And Filling The Pit With Excavated Earth Soil With Proper Ramming. 20 Fixing Of Lt Accessories 21 Mounting Of 25 / 63 / 100 Kva T / F With Proper Jumpering Of Ht Side And Fixing Of Cable On Lt Side Of T / F. 22 Providing And Fixing Of Suspension Clamp, Holding Clamp & Lt Clamp 23 Removing Of Old Acsr Weasal 24 Laying, Stringing & Proper Sagging Of Acsr Weasal Conductor For 3 Phase, 4 Wire Lt Line Including Binding & Jumpering Properly. 25 Earthing Of Each 11 Kv Line And T / Fproperly After Drive Of Electrodes If Size 20Mm X 250 Mm And Connection The Earthing Point With Gl Wire. 26 Removing Of 63 Kva T / F From Double Pole 27 Grouting Of Pcc / St Pole 28 Providing And Fixing Of Ms Nut & Bolts Off Size 29 Laying, Lifting Of Lt Ab Cable Of Size 3X95+1X70+1X16 30 Laying, Lifting Of Lt Ab Cable Of Size3x50+1X35+1X16 31 Back Cartage Old And Damage Acsr Weasal Conductor 32 Back Cartage 63 Kva T / F From Site To Central Store Meerut

Key Value

Document Fees
INR 1180 /-
EMD
INR 1550.0 /-
Tender Value
INR 1.55 Lakhs /-

BOQ Items

Name of Work: fo|qr forj.k [k.M izFke] esjB ds vUrxZr mi[k.M izFke] ckxir jksM ,oa mi[k.M f}rh;] ijrkiqj ds dk;Z {ks= esa 33@11 dsoh fo|qr midsUnz xxksy&izFke ,oa eksfgmn~nhuiqj ls iksf"kr fofHkUu LFkkuks ij iz.kkyh lq/kkj ;kstuk ¼fctusl Iyku o"kZ 2023&24½ ds dk;ZA
Sl. No. Item Description
1Cartage of following material from store center Meerut to JE Store including loading & unloading at both ends maximum distance up to 30 Km. :-
2PCC Pole 8.5 Mtr Long/ST Pole 11 mtr long
3LT AB Cable 3x95+1x70+1x16
4LT AB Cable 3x50+1x35+1x16
525/63/100 KVA T/F
63 Phase LT Distribution Box
7ACSR Weasal Conductor
8line material as such stay set, pin insulator, disc insulator, earthing rod, GI wire, ms angle, ms channel, top channel, dropper channel, dead clamp, piercing clamp etc.
9Cartage of following material from JE, Store to site of work including loading & unloading at both ends maximum distance up to 30 Km. :-
10PCC Pole 8.5 Mtr Long/ST Pole 11 mtr long
11LT AB Cable 3x95+1x70+1x16
12LT AB Cable 3x50+1x35+1x16
1325/63/100 KVA T/F
143 Phase LT Distribution Box
15ACSR Weasal Conductor
16line material as such stay set, pin insulator, disc insulator, earthing rod, GI wire, ms angle, ms channel, top channel, dropper channel, dead clamp, piercing clamp etc.
17Erection of PCC pole 8.5 Mtr/ST Pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including back filling of the pole with proper ramming after completion of work.
18Erection of Double pole on PCC pole 8.5/ST Pole 11 mtr long after digging a pit of size1.6 mtr deep in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work.
19Erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
20Fixing of LT accessories
21Mounting of 25/63/100 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F.
22Providing and fixing of Suspension Clamp, Holding clamp & LT Clamp
23Removing of old ACSR Weasal
24Laying, stringing & proper sagging of ACSR Weasal conductor for 3 phase, 4 wire LT line including binding & jumpering properly.
25Earthing of each 11 KV line and T/Fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire.
26Removing of 63 KVA T/F from double pole
27Grouting of PCC/ST Pole
28Providing and Fixing of MS Nut & Bolts off size
29Laying, lifting of LT AB Cable of size 3x95+1x70+1x16
30Laying, lifting of LT AB Cable of size3x50+1x35+1x16
31Back cartage Old and Damage ACSR Weasal Conductor
32Back cartage 63 KVA T/F from site to central store meerut
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail