Tender For Construction Of New Pwd Rest House And 2 Nos. 550 Sft. Class-Iv Residence At Village Patauda In Jhajjar District (Pdg. Fire Alarm System Only), patoda-Haryana

Public Works Department-PWD has published Tender For Construction Of New Pwd Rest House And 2 Nos. 550 Sft. Class-Iv Residence At Village Patauda In Jhajjar District (Pdg. Fire Alarm System Only). Submission Date for this Tender is 20-04-2023. Alarm Systems Tenders in patoda Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37141954
Tender For Construction Of New Pwd Rest House And 2 Nos. 550 Sft. Class-Iv Residence At Village Patauda In Jhajjar District (Pdg. Fire Alarm System Only)
Open Tender
Indian
Haryana
patoda
20-04-2023

Tender Details

Construction Of New Pwd Rest House And 2 Nos. 550 Sft. Class-Iv Residence At Village Patauda In Jhajjar District (Pdg. Fire Alarm System Only) The Government Of Haryana Has Approved A Scheme For The Construction Of Subject Cited Building Along With 2 Nos. Class-Iv (550Sft.) Residences. The Work Stands Administratively Approved Amounting To Rs. 745.01 Lakhs Only Vide The Additional Chief Sec

Key Value

Document Fees
INR 1000 /-
EMD
INR 12720.0 /-
Tender Value
INR 6.03 Lakhs /-

BOQ Items

Name of Work: Construction of New PWD Rest House and 2 Nos. 550 Sft. Class-IV Residence at Village Patauda in Jhajjar District (Pdg. Fire Alarm System only).
Sl. No. Item Description
1HSR Items
2[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
3NS Items
4SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Bosch FPA 1000 Series / Honeywell Morley DXE /Siemens Cerberus / GST 200
5SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FPA 1000 Series / Honeywell Morley DXE /Siemens Cerberus / GST 200
6SITC of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring Make: Bosch / Siemens Cerberus/ Morley / Edwards
7SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make Siemens cerberus/ Morely/ Edwards
8SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the ob in all respect upto the entire satisfaction of Engineer - in - charge of work. Make: Make Bosch/ Morley/ Siemens/ Cerberus/ Edward
9SITC of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power supply relay etc. with all accessories required to complete the job in all respect upto the entire satisfaction of engineer-n-charge of the work. Make: National / Kheraj
10SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Make: GLOLITE / PES / OMEX
11Supply and erection of PVC unsheathed copper conductor cable Size 1.5 sq.mm two core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Havells /Polycab/RR