Tender For Manual Rescue And Operation Rescue And Repair/Replacement Of Firefighting System, Es Ws And Other Misc Em Items ,Electric Supply Installation, Water Supply Installation At Nae Santacruz And Repair Replacement Of Street Lights At Mo (Mb), ghatkopar-Maharashtra

Military Engineer Services-MES has published Tender For Manual Rescue And Operation Rescue And Repair/Replacement Of Firefighting System, Es Ws And Other Misc Em Items ,Electric Supply Installation, Water Supply Installation At Nae Santacruz And Repair Replacement Of Street Lights At Mo (Mb). Submission Date for this Tender is 21-04-2023. Fire Protection System Tenders in ghatkopar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

37070875
Corrigendum : Tender For Manual Rescue And Operation Rescue And Repair/Replacement Of Firefighting System, Es Ws And Other Misc Em Items ,Electric Supply Installation, Water Supply Installation At Nae Santacruz And Repair Replacement Of Street Lights At Mo (Mb)
Open Tender
Indian
Maharashtra
ghatkopar
21-04-2023

Tender Details

Manual Rescue And Operation Rescue And Repair / Replacement Of Firefighting System, Es Ws And Other Misc Em Items , Electric Supply Installation, Water Supply Installation At Nae Santacruz And Repair Replacement Of Street Lights At Mo ( Mb ) Ghatkopar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Apr-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-04-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

BOQ Items

Name of Work : MANUAL RESCUE & OPERATION RESCUE ANDREPAIR/REPLACEMENT OF FIREFIGHTING SYSTEM, E/S W/S AND OTHER MISC E/M ITEMS ,ELECTRIC SUPPLY INSTALLATION, WATER SUPPLY INSTALLATION ATNAE SANTACRUZ AND REPAIR/REPLACEMENT OF STREET LIGHTS AT MO (MB) GHATKOPAR UNDER GE NW BHANDUP
Sl. No. Item Description
1Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting outin soft/loose soil for removing/laying of cables complete all as specified and as directed.
2Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed
3Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed
4M&L for river washed sand and screened dry for cushioning to ug cables in trenches below and around under ground cable for cushioning of cable in ducts including spreading and levelling complete all as specified and as directed.
5Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 10 Sqmm, 3 corecomplete all as specified and directed
6Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 25 Sqmm, 3.5 corecomplete all as specified and directed
7Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 35 Sqmm, 3.5 corecomplete all as specified and directed
8Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 120 Sqmm, 3.5 corecomplete all as specified and directed
9Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 150 Sqmm, 3.5 corecomplete all as specified.
10Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 240 Sqmm, 3.5 corecomplete all as specified
11Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed.
12Laying onlyold unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed.
13Supply and laying HDPE pipes of pressure rating 6 kgf/cm2 (PE-63 grade) of size 32 mm bore laid in trenches for passing of cable complete all as specified and directed.
14Supply and laying HDPE pipes of pressure rating 6 kgf/cm2 (PE-63 grade) of size 40 mm bore laid in trenches for passing of cable complete all as specified and directed.
15Material and labour for GI tubes "Medium Grade" 100 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection complete all as specified and directed.
16Material and labour for GI tubes "Medium Grade" 80 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection complete all as specified and directed.
17Supply and fixing in repairs LED bollards light fitting 10 to 15 wattmushroom shapedmade in cast aluminium spigot housing with decorative clear acrylic diffuser for pleasant light output and weather proof and IP65 protection complete all as specified and directed.
18Supply and fixing in repairs LED post top lanterns fitting made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection 12/15 watt complete all as specified and directed.
19Supply and fixingin repairs highly efficient high power multi LED flood fitting 100/120 watts with pressure die castaluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed
20Supply and fixin repairs highly efficient high power LED street light fitting 100 W with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP65 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting complete all as specified and as directed.
21Supply and fixin repairs highly efficient high power 45/50 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting complete all as specified and as directed.
22Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall complete all as specified and directed. Note : Clamps nuts bolts etc will be measured and paid seprately under relevant items complete all as specified and as directed.
23Supply and fixing in replacement pole mounting box FRP type of size 250mm x 175mm x 100 mm, 3 phase with locking arrangements including necessary nut, bolt and clamps of the flat iron of size 25mm x 4 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, "C" series and 3 phase connector 100Amp for incoming/outgoing cables with proper fixing arrangements on pole / wall complete all as specified and directed.
24Supply and fix in replacement ofFRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channelincluding making connections complete all as specified and directed.
25M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (03 Runof 2.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheateddrawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd
26M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr longand exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no"s with paint complete all as specified and as directed.
27Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, "J" type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a)MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b)4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes:(a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) .quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling. Make :BAJAJ Model BOP-7030 or equivalent in Crompton/Philips/Wipro as approved by GE.
28M&L for mild steel TMT bars 6 mm to 8mm dia cut to length, bent to shape required, stirrups, spaces and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed
29M&L for RCC type B-1, 1:2:4 (nominal mix) using 20 mm graded stone aggregate as in footing, columns, post, pillars, piers, wall of culverts, suspended slabs, edges and struts etc complete all as specified and directed
30M&L for form work to sides of concrete footings, columns, posts, pillars, piers, edges and struts of rectangular or triangular shape for rough finished flat concretesurface complete all as specified and directed
31Supply and fixing in repairs high bay LED light fittings with highly efficient LED baylight made of pressure die cast aluminium housing extraded aluminium heat sink & enclosed with toughended glass IP 66 of capacity 100W , power factor >0.9, 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting,including fixing arrangement on truss with MS Clamps made out of 25x5mm flat iron with nuts, bolts etc complete painting with two coats synthetic enamel paint over a coat of red oxide complete dismantling existing unserviceable high bay fittings all as specified and directed.
32M & L prepration of old exposed surface of garden lightpole 1.5/ 2.5/5 meter long applying two coats ofaluminium paint over a coat of anticorrosivepaint including painting to bottom of polecomplete all as specified and directed.
33Supply and fixing of lithium ions battery capacity of 1.1V, 33AH (366.30), 12V-AH @ C/10 for integrated Solar Street Light fittings 32 watt complete all as specified and directed.
34M&L for finding faults of LT UG cable XLPE,of any size and any length upto 25/35/50/70 Sqmm by using computerised / primary current injection method / any other method as directed by the GE and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing complete all as specified and as directed. Make shall be BIS approved. Note:Joints shall be paid for separately.
35Material and labour for, install, testing and commissioning of automatic Power factor correction panel 34.5 KVAR (APFC panel)(Factory made) working on AC supply system, 3 phase, 50Hz 440 volts, free floor mounting, cubical design, made out of CRCA sheet of thickness 2.0 mm and 1.6 mm for partition IP-42 protection duly powder coated with seimens grey colour including copper bus bar of capacity 300 amps per phase and neutral, MPP-H capacitor 15 stagesconfiguration comprising in for every 0.5 KVAR correction, the panel will operate with 12 combinations up to 11.5 KVAR per phase of 36 combinations upto 34.5 KVAR. The stage wise details of 34.5 KVAR SPC of 15 stages asper following:- I stage: 0.5 kvar/Phase II stage: 1.0 kvar/Phase III stage: 2.0 kvar/Phase IV stage: 4.0 kvar/Phase V stage: 4.0 kvar/Phase(a) 15 stage automatic power factor correction relay digital type micro processor baed suitable for 440 volts, 50 Hz, AC supply system - 1 No (b) Control wiring, auxiliary contactors, timer of suitable capacity and sizes - 1 set (c) ON/OFF indicating lamps with push button - 15 Nos (d) Phase indicating lamp - 01 set (Set of 3)(e) Digital Ammeter 0-400 amps with selector switch - 1 No (f) Digital Voltmeter 0-500 Volts with selector switch - 1 No(g) Auto/manual selector switch - 1 No (h) MCCB fixed type 4 pole, 100 Amps, 25 KA (Incoming) - 01 No
36Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm)and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of "make" having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer"s instructions of "Electrode" and as also certified by any BIS (Bureau of Indian Standards). Make: Fast Electrode/U-Protec Earthing/Shivangi Engineering Works Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer"s test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor"s quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Copper strip 25mm x 3mm upto 7.5RM included above quoted rates.
37Comprehensive maintenance of electrically operated travelling (EOT) crane of 05 MT, Span -44900 mm, SWL-5000 Kgs capacity, floor operated comprising of hoist motor, micro motor, long travel motor, cross travel motor, gear box, control panel and other connected accessories installed at NAE Santacruz Note: Contractor should be provide the load test of crane as per directed by Engineer-in-Charge.
38M & L for painting 5 ton crane completely with two coats of golden yellow paint including preparation of existing surface by scrapping detoritied paint etc. all as directed by Engr-in-charge.
39To carry out load Test of 5 MT Crane as per Manufacturer norms and provide a load test certificate by manufacturer all as specified.
40Repair, Maintenance & Servicing of DG Set 500 KVAcomplete including with B Checkthrough OEM as per direction of Manufacturer as directed.
41Material only for carrying out "B" check for 500KVA DG set all as per manufacturers instructions. Note : Rate quote shall be deemed to be inclusive of sparesbut excluding engine oil.
42Supply and replacement of Greaves Max Therm Lub Oil
43Supply and replacement of Oil filter
44Supply and replacement of Fuel filter
45Supply and replacement ofK Kool additive oil
46Comprehensive /Annual maintenance of CCTV System installed at NAE Santacruz and comprising of the following itemsas under :- Mini PTZ Domecameras-4 Nos 16 Ch digital video recorder (DVR) - 01 No KBD digital keyboard/Joystick 24 Volt 2.1 Amp power supply -03 Nos Professiona CCTV Bosch monitor 21.5"-01 No Panasonic 22" LED TV -01 Nos 2 TB Survelliance harddisk Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
47Comprehensive Annual maintenance of fire alarm system installed at NAE Santacruz comprising of following items Main control panel -02 Nos Heat and smoke detector-150 Nos Mannual call point -12 Nos Hooter cum strobe- 20 Nos Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
48Supply and fix in repair Smoke and Heat Multisensor detector complete all as specified and directed.
49Repair and maintenance of 75 HP fire service main pump multi stage having 2280 LPM at 80 Mtr head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100 HP diesel engine including servicing byreplacing unserviceable items of gland packing , bearing and charging lubricants for smooth running including servicing of 75 HP diesel engine by replacing filters, lubricant oil including defective parts like coupling , oil air filters, servicing of radiator, replacement exhaust gasket, replacement of diesel supply and return pipes from tankto engine, battery leads and checking of charging circuit complete including base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed.
50Takig down unserviceable Fire fighting motor pump setof capacity 3 phase 100 HP disconnecting the all necessary electrical connections and dismantlng the pump side and replacing the worn out winding and connected items like bearings, bush and coupling and rubber coupling etc; and rewinding with super enameled copper wire of suitable guage including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete all as specified.
51Repair and maintenance of 7.5 hp fire service jockey / booster pump multi stage having 180 LPM at 56 mtrs head multi stage pump of horizontal split casing running at 2900 RPM coupled with 7.5 hp AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth runningincluding painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed.
52Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 02 ton of any make /type after disconnecting refrigerant pipes , drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda , checking and replacing the spares like relay, capacitors, thermostat, fan motor blades & blower and including servicing, overhauling and connecting of refrigerant pipe, drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed.
53Repair/Replacement of fire fighting hose reel of 20mm dia & 30 mtrs long confirming to IS-5132 complete all as specified and directed
54Repair/Replacement of fire fighting branch pipe & nozzle for 20 mm dia hose reel confirming to IS 8090 complete all as specified and directed
55Repair/Replacement of fire fighting fire hydrant stand post with provn of single outlet confirming to IS 908 complete all as specified and directed
56Repair /Replacement of fire fighting branch pipe & nozzle gun metal short branch pipes 63mm dia with male instantaneous inlet with Gun metal, hexagonal, detachable outlets nozzles bearing IS-903 complete all as specified and directed
57Repair /Repalcement of Hydrant valves Female oblique type gun metal hydrant valve bearing IS 5290 type A 63 mm dia with flanged inlet and female instantaneous spring back outlet connection and complete with male blank cap & chain single hydrant valve complete all as specified and as directed.
58Supply and fixingblower drum for split type air conditioner 2.0 ton capacity complete all as specified and as directed.
59Supply and fixing outdoor fan blade for split type air conditioner 2.0 ton capacity complete all as specified and as directed.
60Supply and fixingoutdoor fan motor for split type air conditioner 2.0 ton capacity complete all as specified and as directed.
61Supply and fixingrunning capacitor 45 mfd for split type air conditioner 2.0 ton capacity complete all as specified and as directed.
62Supply and fixingstarting capacitor100mfd for split type air conditioner 2.0 ton capacity complete all as specified and as directed.
63Supply and fixingfan capacitor 4 mfd for outdoor unit for split type air conditioner 2.0 ton capacity complete all as specified and as directed.
64Supply and fix new hermetically sealed compressor in existingsplit type air conditioner 2.0 ton capacity including initial filling of refrigerant gas to the required pressure , brazing making electric/pipingconnectionetc completeall as specified and directed. Make: Voltas/ Shriram/ Tecumesh/ Kirloskar/Hitachi/ LG/ Bluestar or as approved by GE.
65Mannual rescue & Operation rescueforelectric supply installations 11/0.433 KV sub Station & stand by diesel Generator Sets comprising of transformer, AMF panels, APFC panels, HT VCBs, ACBs, LT Panels/FP Boxes, LT/HT UG Cables, lightning Arrestor, Earthing,metering equipments & batteries etc including routine maintenance, cleaning of equipments, Maintaining of daily records of electric supply and log books of DG sets with all parameters with stationery and including atending of electrical break downs and electrical repairs as directed with necessary expendable items and providing all types of tools and clamp meter, IR/ER tester, Earth rod, Hand Gloves, ladders etc and adopting necessary safety precautions in attending break downs, and electrical repairs, switching on/off street lights, top up of fuel as provided/stored by department and cleaning of equipments and surrounding area of installations in neat and presentable position by deploying Electrician (ITI Holder) - 01 in each shift of 08 hours duration required in two shifts in a day in all the days including sundays and holidays with arrangement of reliever duty at NAE Santacruz comprising of following shifts complete all as specified and directed :- Shift Timings (a) First Shift: 0600 hrs to 1400 hrs (b) Second Shift: 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs NOTE : Arrangement for deposition of necessary documents for issue of passes from MIAL/CISF/GVK authority for the trademen will be contractor"s responsibility in consultation with MES/ users. (i) To provide uniform, tools & plants, safety means like glove etc to the employees and also alternative employees (reliever) for Manual rescue and Operation rescue of E/M plants/ Installation so that the other employees can avail the facility of weekly leave etc. (ii) To keep the E/M Plant/ installaton Room & allied area in clean and tidy conditon during the operation period. (iii) To carryout the routine maintenance, minor repairs and to rectify the minor defects to keep the plant / installation in serviceable condition all as directed by the GE and Engineer-in-Charge. However, the major repairs, replacements are not included in the scope of the above items. (iv) To keep necessary documentation duly signed by all the concerned. (v) Contractor shall submit the details of payment of wages for staff employed through Aadhaar linked bank accounts for payment pourpose. (vi) Condition towards bonus EPF, ESIC the amount is payableonly after submission of valid and authentic document in support of having paid the requisite amount to the employed labour.
66Mannual rescue & Operation rescue for water supply and fire fighting installations with pump sets 03 phase, 415 Volts, AC 50Hz comprising of pumping panel boards, control cables, metering equipment, earthings, star delta/DOL starters, etc including operating of valves, NRVs and connected pipe lines and routine maintenance, maintaining of daily records of pumping installations with all parameters with stationary and including attending of water supply break downs as directed with necessary expendable items and providing of tools and clap meter IR/ER tester etc and adopting necessary safety precautions in attending break downs and cleaning of equipment and surrounding area of installations in neat and presentable position by deploying Fitter General Mechanic(FGM) ITI Holder - 01 No in each shift of 08 hours duration required in three shifts in a day round the clock(24 Hours ) in all the days including Sundays and Holidays with arrangement of reliever duty with following equipments/installations at NAE Santacruz comprising of following shifts complete all as specified and directed (a) Centrifugal pump set of make Kirloskar 05HP - 02 Nos (b) Fire fighting pump (AC driven) 2850 LPM (c) fire fighting pump ( diesel engine driven) 2280 LPM (d) Jockey pump 180 LPM (e) Fire Fighting piping network with hydrants and valves. Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs Note : Arrangement for deposition of necessary documents for issue of passes from MIAL/CASF/GVK authority for the tradesmen will be contractor"s responsiblity in consultation with MES/ users. (i) To provide uniform, tools & plants, safety means like glove etc to the employees and also alternative employees (reliever) for Manual rescue and Operation rescue of E/M plants/ Installation so that the other employees can avail the facility of weekly leave etc. (ii) To keep the E/M Plant/ installaton Room & allied area in clean and tidy conditon during the operation period. (iii) To carryout the routine maintenance, minor repairs and to rectify the minor defects to keep the plant / installation in serviceable condition all as directed by the GE and Engineer-in-Charge. However, the major repairs, replacements are not included in the scope of the above items. (iv) To keep necessary documentation duly signed by all the concerned. (v) Contractor shall submit the details of payment of wages for staff employed through Aadhaar linked bank accounts for payment pourpose. (vi) Condition towards bonus EPF, ESIC the amount is payableonly after submission of valid and authentic document in support of having paid the requisite amount to the employed labour.
67S & F Digital display board (Monitor) compelling UHD picture quality, extensive connectivity and ongoing 24/7 performance of size 49 inch minimum resolution 1920 x 1080 (16.9) contrast ratio 3000:1 of supporting port HDMI In, DPIn, DVIIn, USB, RGBIn, RS232In, RS232Out, RJ45In signage TV with minimum 5 years warranty. Make: Samsung Model No.LH49PHFPBGC/XL or equivalent to LG/SONY/LLYOD
68Deduct Credit for Demolished/ Dismantled material Rs. (-) 95245.00(Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the "Contract Sum" Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail