Tender For Providing Lifts, Fire Alarm System, Servo Stabilizer, Cctv, Music System For Lift, Special Repair To E.I., Automatic Power Factor Control Panel For Sub Station, Ups For Meeting Hall And Security Light In Mini Sectt. Sector 12 Faridabad ( Repla, faridabad-Haryana

Public Works Department-PWD has published Tender For Providing Lifts, Fire Alarm System, Servo Stabilizer, Cctv, Music System For Lift, Special Repair To E.I., Automatic Power Factor Control Panel For Sub Station, Ups For Meeting Hall And Security Light In Mini Sectt. Sector 12 Faridabad ( Repla. Submission Date for this Tender is 24-04-2023. Alarm Systems Tenders in faridabad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37058371
Tender For Providing Lifts, Fire Alarm System, Servo Stabilizer, Cctv, Music System For Lift, Special Repair To E.I., Automatic Power Factor Control Panel For Sub Station, Ups For Meeting Hall And Security Light In Mini Sectt. Sector 12 Faridabad ( Repla
Open Tender
Indian
Haryana
faridabad
24-04-2023

Tender Details

Providing Lifts, Fire Alarm System, Servo Stabilizer, Cctv, Music System For Lift, Special Repair To E.I., Automatic Power Factor Control Panel For Sub Station, Ups For Meeting Hall And Security Light In Mini Sectt. Sector 12 Faridabad ( Replacement Of Fire Alarm System And Public Address System )

Key Value

Document Fees
INR 5000 /-
EMD
INR 120570.0 /-
Tender Value
INR 60.28 Lakhs /-

BOQ Items

Name of Work :PROVIDING LIFTS, FIRE ALARM SYSTEM, SERVO STABILIZER, CCTV, MUSIC SYSTEM FOR LIFT, SPECIAL REPAIR TO E.I., AUTOMATIC POWER FACTOR CONTROL PANEL FOR SUB STATION, UPS FOR MEETING HALL AND SECURITY LIGHT IN MINI SECTT. SECTOR 12 FARIDABAD ( REPLACEMENT OF FIRE ALARM SYSTEM AND PUBLIC ADDRESS SYSTEM)
Sl. No. Item Description
1FIRE ALARM SYSTEM SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in allrespects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of workMakes : BoschFPA 5000 Series, Notifier NFS 3030 and Cerberus PRO by Siemens / Edward EST-3.
2SITC of Public Address System in Rack: consisting of the following480W Amplifier to suitable size Make : BOSCH / HONEYWELL / EDWARD /Heinrich - 01 No. Selector & all facility for announcement of different floor - 01 SetInterface unit for integration of main fire alarm panel with public address system = 01 No.
3Supply, Installation, Testing & commissioning ofCelling Mount Speaker with Plastic Mount or without mount as per site requirement for operation 6 Watts Make Honeywell/ BOSCH/Henrich
4SITC ofaddressable Heat detector with fixed andrate of raise feature including mounting base with LED etc. complete as required.Each Detector should have 2as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Makes: Bosch / Siemens Cerberus / Notifier/ Edwards
5SITC of addressable multisensor detector with a combination of Opticaland Thermalincluding mounting base, auto addressing feauture asrequired.Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Makes: Bosch / Siemens Cerberus / Notifier/ Edwards
6SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes: Bosch / Siemens Cerberus / Notifier/ Edwards
7SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes: Bosch / Siemens Cerberus / Notifier/ Edwards
8SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes: Bosch / Siemens Cerberus / Notifier/ Edwards
9SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work MakePES/Giolite/OMEX
10SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment).Make: Bosch / Siemens Cerberus / Notifier/ Edwards
11SITC ofAddressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall beEN54/UL/VDS CertificationMake: Bosch / Siemens Cerberus / Notifier/ Edwards
12SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Bosch / Siemens Cerberus / Notifier/ Edwards
13SITC of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj
14Supply and erection of PVC Insulated and FRLS Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 complete in all respect upto the entire satisfaction of Engineer in charge of the work 2 core PVC unsheathed copper size 1.5 sq mm
15Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. (As per HSR 2021 item no. 23.7.6.2)25 mm dia
16SITC of battery backup for controllers ( 2 KVA UPS on line with 1 hours backup ) and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make APC/ LIEBERT EMERSON/Microtek/ Aar Kay
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail