Tender For Repair/Maintenance Of Servo Voltage Regulator, Eot/Hot,Aviation Lights And Connected Works Under Ge (Af) Jamnagar No 01., jamnagar-Gujarat

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Servo Voltage Regulator, Eot/Hot,Aviation Lights And Connected Works Under Ge (Af) Jamnagar No 01.. Submission Date for this Tender is 09-05-2023. Electrical Products Tenders in jamnagar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

37052974
Corrigendum : Tender For Repair/Maintenance Of Servo Voltage Regulator, Eot/Hot,Aviation Lights And Connected Works Under Ge (Af) Jamnagar No 01.
Open Tender
Indian
Gujarat
jamnagar
09-05-2023

Tender Details

Repair/Maintenance Of Servo Voltage Regulator, Eot/Hot,Aviation Lights And Connected Works Under Ge (Af) Jamnagar No 01.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Apr-2023 Corrigendum No. 1 Date 27-04-2023
2 13-Apr-2023 Corrigendum No. 02 BOQ 27-04-2023
3 27-Apr-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-05-2023
4 04-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work: Repair/Maintenance of servo Voltage regulator, EOT/HOT,Aviation lights and connected works under GE (AF) Jamnagar No 01.
Sl. No. Item Description
1Comprehensive maintenance of HOT gantry crane of capacity 1 Ton to 2 Ton, greasing & oiling of component, checking of serviceability of all component complete all as specified and directed .
2Comprehensive maintenance of EOT gantry crane of capacity 0.3 Ton to 3 Ton, greasing & oiling of component, checking of serviceability of all component, complete all as specified and directed .
3Comprehensive maintenance of EOT gantry crane of capacity 5 Ton to 10 Ton, greasing & oiling of component, checking of serviceability of all component, complete all as specified and directed . Note for item No 1 to 3:- (i) Replacement of unserviceableSpare part will be measured & paid separately under respective item of Schedule (i
4Deployment of tools / equipment for Comprehensive load testing of HOT/EOT gantry crane of capacity 0.3 Ton to 3 Toncarrying out (once in a completion period of contract)all as directed .
5Deployment of tools / equipment for Comprehensive load testing of HOT/EOT gantry crane of capacity 5 Ton to 10 Toncarrying out (once in a completion period of contract)all as directed . Note for item No 4 & 5:- (i) Required load for testing of crane will be provided by the contractor under his own arrangement. (ii) Load testing shall be carried out through authorise service provider of OEM/as per specifided and directed by Engineer-in-charge and Contractor shall produce certificate after load testing for the same.
6Materialand labour for changing of gear oil ofEOT crane of capacity 0.3 to 10 ton after draining out old oil cleaning of gear box etc complete all as directed .
7S&F in repair power contactors of capacity 16 Amp 3 pole, 415 volt fixed to EOT crane & connecting complete all as directed .
8S&F in repair power contactors of capacity 32 Amp 3 pole, 415 volt fixed to EOT crane & connecting complete all as directed .
9S&F in repair power contactors of capacity 40 Amp 3 pole, 415 volt fixed to EOT crane & connecting complete all as directed .
10Supply and fix in repair single phase preventer for EOT crane & connecting complete all as directed .
11S&F in repair Flame proof PendentofEOT crane with capacity 0.3 ton to 3 ton including (Forward & Reverse, Left & Right, Start & Stop, Up & Down, Emergency Stop) allconnecting functioncomplete all as directed .
12Dismantling & Refixing ofwire rope of EOT/HOT crane fromRope Drum ofcapacity of 0.3 ton to 10 ton connectingcomplete all as directed . (Note -Checking of wire for its strenghing capacity and serviceability of steel wire rope.)
13S&F in repair flexible control cable, PVC insulated, PVC sheathed with multistranded, copper conductor, of size 4 sqmm 4 core, suitable for EOT crane & connecting complete all as directed .
14S&F in repair flexible control cable, PVC insulated, PVC sheathed with multistranded, copper conductor, of size 1.5 sqmm 16 core, suitable for EOT crane & connecting complete all as directed .
15S&F in repair of brakeliner & lock set suitable for 2 ton to 3 ton capacity HOT crane complete all asdirected .
16S&F in repair Limit Switches to control the movement of wheels of EOT crane of capacity 0.3 to 3 ton, fixed in position & connecting complete all as specified & directed .
17S&F in repair Limit Switches to control the movement of wheels of EOT crane of capacity 5to 10 ton, fixed in position & connecting complete all as specified & directed .
18M&L for Repairing of 1 HPcapacity electric motorof EOT crane, AC 3 phase, by dismantling the motor and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super enamelled copper winding wire, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all as specified and directed .
19M&L for Repairing of 2 HP capacity electric motorof EOT crane, AC 3 phase, by dismantling the motor and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super enamelled copper winding wire, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all as specified and directed .
20Dismantling & Refixing of servo Voltage Stabilizer / isolation transformer of any capacity (10 KVA to 400 KVA) and Testing for its serviceability with identifying the fault at installed location complete directed by Engg in Charge. (Note :- Transportation charges to & frorequired is deemed to be in the rate quoted and replacement of unserviceable spare part will be measured & paid seprately under respective item of this schedule.
21Overhauling of LT oil cooled servo controlled voltage stabilizer of capacity 10 to 50 KVA by disconnecting of electrical connections, draining out complete stabilizer oil, cleaning & decaling of entire internal surface, core &winding, reassemble, by replacement of complete set of carbon bushes, nut, bolt, washer packing etc, refilling the same stabilizer oil and reconnecting withelectrical connections, testing and commissioning on load complete all as specified & directed by Engr-in-Charge for the following stabilizers. Note:- (i) Filtration of stabilizer oil if required will be measured & paid separately. (ii) Topping up with new stabilizer oil if required will be measured & paid separately
22All as per item No 21 above but voltage stabilizer of capacity 75 to 100 KVA.
23All as per item No 21 above but voltage stabilizer of capacity 125 to 200 KVA.
24All as per item No 21 above but voltage stabilizer of capacity 225 to 450 KVA.
25M & L for rewinding of Stabilizer /Isolationtransformer of any capacity by dismantling and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with supper enamelled copper winding wire of the same gauge and turn with proper class of insulation impegrauated & baking, assembling and testingincluding replacement of cork sheet, neoprene gasket etccomplete all as specified and directed . Note : Transportation to & fro to local company workshops are deemed to be included in above quoted rates.
26Supply & fix in repair Electronic circuit card comprising IC"s, Regulators, Condensers, Transistors, Triac etc of servo controlled voltage stabilizer of any capacity completeall as specified and directed .
27Supply & fix in repair protection alarm circuit incorporating High & Low voltage cut-off, overload cut-off, phase reversal protection of servo voltage stabilizer of any capacity complete all as specified and directed .
28Supply & fix in repair torque motor of capacity 10 kg.cm forservo voltage stabilizer complete all as specified and directed .
29Supply & fix in repair torque motor of capacity 20 kg.cm forservo voltage stabilizer complete all as specified and directed .
30Supply & fix in repair Micro Switch of servo voltage stabilizer complete all as specified and directed .
31Supply & fix in repair selector switch of servo voltage stabilizer complete all as specified and directed .
32Supply & fix in repair control switches of servo voltage stabilizer complete all as specified and directed .
33Supply & fix in repair electronic/Analog type Voltmeter of servo voltage stabilizer complete all as specified and directed .
34Supply & fix in repair electronic/Analogtype ammeter of servo voltage stabilizer complete all as all as specified and directed .
35Supply & fix in repair neon indicators of servo voltage stabilizer completeall as specified and directed .
36S&F in repair LT metal parts and LT bushing suitable for 200/150 KVA indoor voltage stabilizer complete all as specified and directed .
37S&F in repair LT metal parts and LT bushing suitable for 100/75/50 KVA indoor voltage stabilizer complete all as specified and directed .
38S&F in repair LT metal parts and LT bushing suitable for 10 to 50 KVA indoor voltage stabilizer complete all as specified and directed .
39Dehydration / filtration of transformer oil of Isolation transformers,Stabilizers etcof various capacities installed at different locations by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength not less than 40 KV. Note- Quoted rates shall be deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.
40(iii) Transformer oil for topping up will be measured and paid in relevant item as required (iv) Dehydration & filtration of oil transformer shall be carried out ON-Line. Shut down will be given for making necessary pipe / hose line connection from machine to stabilizer / transformer.
41Supply & topping up of transformer oil up to required level for Isolation transformer , stabilizersetc of dielectric strength 50 KV &aboveall as perIS specification.
42Preventive maintenance / servicing of electric operated boom barrier for smooth functioning of any make, maintenance by cleaning of complete unit checking of all electrical component & wiring etc oiling / greasing of moving part including replacement of unserviceable component complete all as directed and directed by Engr-in-Charge.
43Note:-(i) Unserviceable spares parts will be measured & paid separately as supply & fix in repair.
44(ii) Maintenance Work shall be executed through Authorised service technician of OEM.
45(iii) Contractor shall submit the documentary evidence of Authorised service technician for the approval of GE before commencement of work.
46(iv) Contractor shall submit certificate, obtain from Authorised service centre that work has been executed by them.
47(v) Above said certificate shall be endorse by Engineer-In-Charge.
48Supply & fix in repair of boom of boom barrier any length fabricated with aluminium rectangular section of size 45 mm x 100 mm x wall thickness 1.5 mm, cut to size including powder coating & reflective sheet band complete as directed & as per manufacture instruction.
49Supply & fix in repair barrier lock for the safety of mother board, motor from dust and better serviceability complete all as specified and directed .
50Supply & fix in repair wireless Remote control unit with battery for opening & closing of boom of boom barrier complete all as specified and directed .
51Supply andfixin repair of complete Mother Board, comprising control board of boom barrier, Limit switch interface, radio receiving interface complete all as specified and directed .
52Supply andfixin repair of Radio receiver for communicate with remote and control board complete all as specified and directed .
53Supply & laying 40 mm bore mild steel galvanised iron tubing light grade for protection of cable /earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ductsetc, including taking down old tubing complete all as specified and directed .
54Supply, installation, testing, & commissioning, factory made, CPRI approved, outdoor type, LT Panel board, compartmental type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including Mild steel angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof, gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated, internal wiring with PVC insulated multi-stranded copper conductor cable of appropriate size & length with fixing lugs, bolts, screws etc complete including taking down old panel, complete all as directed and directed by Engr-in-Charge....
55...& Consisting of the followingswitchgear:-(a) Aluminium bus bar of size 100 amps for phase and 50 amps for neutral & shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on proper insulator etc including connection complete. - 01 set
56(b)LED indicator lamp with holder (Yellow, Blue, Red) – 01 set (Set of Three)
57S & F voltage surge protection device (SPDs) for low voltage power distribution system 3 phase, 4 wire system 415 V type II (8/20 micro sec) 40 Ka, 3 Phase + neutral, 4 module complete all as directed and directed .
58Supply and fix in repair technical manual MCB Changeover switch, two way centre off, Four pole,40 A, 415 V - 50 Hz, rated impulse voltage 4 KVfixed in existing panel & connecting complete all as specified & directed .
59Supply and fix in repair MCB 63 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed.
60Supply and fix in repair MCB 32/40 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed.
61S&F in repair LED Traffic signal light, 24W, viewing angle 23°,high intensity, ,polycarbonate body with IP65 protection, fire retardant, glass epoxy,FR4 printed circuit board with protection cover and clear polycarbonate concave lenses, input voltage 210-240V,working temperature -40°C to 80°C in colour indication of Green/Red for giving signal to move or stop for vehicle/person fixed on existing pole all as specified & directed . Make:- Nucleonics / Trafitronics or equivalent approved by GE
62Note : - (i) Work shall be executed by the authorised service mechanic / Electrician of manufacturer, after satisfactorycompletion of servicing of isolation transformer / Voltage Stabilizer Boom Barrier any fault occur upto completion of contract period should be attended by concerned rep within stipulated time frame without any failure, quoted rates is deemed to be included all such charges. (ii) Item No. 1 to 53 if any above any HT Equpiment and connected item become breakdown, the contractor shall locate the problem / fault at site within 12 hours on intimation by JE / Engineer-in-Charge and ensure the fault and rectifies it within 48 hours, failing which an amount of Rs. 200/- per Hour will be recovered as penal recovery from any payment due to contractor after expiry of 48 hours.