Annual Plan-Installation Of Fire Saftey Equipments In Mcf And Rrf -Installation Of Fire Saftey Equipments In Mcf And Rrf At Parakkod In Adoor Muncipality-General Electrical Work, adoor-Kerala

municipality has published Annual Plan-Installation Of Fire Saftey Equipments In Mcf And Rrf -Installation Of Fire Saftey Equipments In Mcf And Rrf At Parakkod In Adoor Muncipality-General Electrical Work. Submission Date for this Tender is 17-04-2023. Bolts Tenders in adoor Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

37050016
Corrigendum : Annual Plan-Installation Of Fire Saftey Equipments In Mcf And Rrf -Installation Of Fire Saftey Equipments In Mcf And Rrf At Parakkod In Adoor Muncipality-General Electrical Work
Open Tender
Indian
Kerala
adoor
17-04-2023

Tender Details

Annual Plan-Installation Of Fire Saftey Equipments In Mcf And Rrf -Installation Of Fire Saftey Equipments In Mcf And Rrf At Parakkod In Adoor Muncipality-General Electrical Work-Part 1-Electrification-List Of Materials Attached Seperately 2 Od322619 / 2022-2023:Supply And Installation Of Dust And Vermin Proof Wall Mounting Meter Box ( 450X375x200mm ) Sintex Make ( Gsmb-4537 ) With Base Plate Suitable To Fix Single Phase Energy Meter And Hrc Fuse Units And Neutral Link On Wall Using Suitable Nut Bolt Etc. 3 Od322620 / 2022-2023:63 A, 2 Way Neutral Links Mounted On Dmc / Smc Base 4 Od322805 / 2022-2023:Supply And Providing 63, Hrc Fuse Base With Suitably Ratedlink 5 90.11.1.14:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator / Rccb / Rcbo As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) 6 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 7 2.10.4:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole 8 2.11:Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 9 2.13.2:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 10 2.15.3:Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 11 90.2.2.4:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Group B / Rohs Compliant Modular Accessories ) .Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point 12 90.4.2:Supply And Installation Of Suitable Size Ms Belt Type Fan Clamp Fabricated From Flat Iron 40 X 6 Mm, 150Mm Long X 2 Nos With M.S. Rod Bent To Shape, Neatly Painted With 2 Coats Of Enamel Paint Over A Coat Of Red Oxide Primer As Per Is 732 As Required. 13 Od399135 / 2022-2023:Supplying And Providing Extra Length Of Conduit Downrod With 15 Mm Dia B Class Gi Pipe1.00 M Long With 16 / 0.20 Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring And Giving Connection Etc. As Required. 14 Od399136 / 2022-2023:Supply And Installation Of 1200Mm Sweap Ceiling Fan With Standard Accessories With Out Reglator Including Giving Connection With 16 / 0.20 Mm 3Core Round Copper Conductor Flexible Chord Etc As Required. ( Crompton ( High Speed ) / Havells ( Thril / Aero ) 15 90.15.4.5:Supply Conveyance, Installation, Testing And Commissioning Of 40W Led Flood Light Output Greater Than 105Lumen / W 4000-6000 K With Ip 66 Protection Led Chip Make Cree / Lumilled / Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv, And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) 16 90.17.4.2:Supplying, Installation, Testing And Commissioning Of Electric Driven Terrace Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required: ( Terrace Pump ) A. Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Confirming To Is : 1520B. Suitable Hp Squirell Cage Induction Motor Tefc Type Suitable For Operation On 415 Volts, 3 Phase, 50 Hz, Ac Supply With Ip55 Class Of Protection For Enclosure, Horiziontal Foot Mounted Type With Class-F Insulation, Conforming To Is-325.C. M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc.As Required.D. Suitable Cement Concrete Foundation Duly Plastered And With Anti Vibration Pads.450 Lpm At 35 M Head 17 14.8:Providing And Laying In Position Cement Concrete 1 :3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. 18 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement: 4 Fine Sand ) At All Levels 19 90.14.5:Supply And Fabrication Conveyance And Installation Of Angle Iron Frame Work For Wall Mounting Panel Board 20 Od393709 / 2022-2023:Supply, Installation Testing And Commissioning Of Wall Mounted Cubicle Type Switch Board Of Suitable Size Made Out Of 2 Mm Thick Ms Sheet Totally Enclosed, Dust And Vermin Proof With An Additional Lockable Glazed Door On The Front And Consisting Of The Following Items Such As 1 No 32 Amps Tpn Switch Fuse Unit With Hrc Fuses, 1 No Dol Starter Suitable For The Pump Set, 0-30 Amps Ammeter With Cts, Selector Switch - 1 Set, 0-500V Voltmeter With Selector Switch - 1 Set, 3 Phase Indication Lamps 1 Set Etci / C Connections With Suitable Copper Conductor Cable, Earthing, Painting ( Red ) , Lettering Etc. As Required. 21 1.21.1:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 22 1.21.4:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.40 Mm 23 1.17.2:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 1.5 Sq. Mm 24 1.24.1:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 25 1.24.4:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 26 1.27.3:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.4 Module ( 125Mmx75mm ) 27 90.12.7.40:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 10 Sq Mm With Factory Made Clamp 28 90.12.7.41:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp 29 9.1.32:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) 30 9.1.33:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) 31 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 32 5.9:Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 33 90.16.1.1:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) 34 5.14:Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 35 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 36 90.16.2.1:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.15.Mm Dia. G.I Pipe ( Medium Class ) 37 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 38 Od322814 / 2022-2023:Supply And Providing 25X6 Mm Brass Nut And Bolt With Washers In Position Including Drilling Holes 39 Od322623 / 2022-2023:Charges For Preparation Of Kseb Service Connection Documents For Availing Three Phase Service Connection And Producing To The Consumer Including Test Report Drawing Etc. 40 Od400017 / 2022-2023:Supply And Installation, Testing And Commissioning Of Portable Fire Extinguisher Complete Withinstallation Brackets Confming Tois15683 With Isi Mark Bis 2190 And Bis: 15683:2006 And With Relevant Iss Stamping / Marking.Co2 41 Od400018 / 2022-2023:Charges For Preparation Ofdocuments For Availing Fire Noc From Concerned Department And Producing To The Consumer Including Test Report Drawing Etc 42 Od400019 / 2022-2023:Supply And Installation Of Abc Type Fire Extinguisher Of 4 Kg. Capacity Complete With Initial Charges And Installation Brackets Confming Tois15683 With Isi Mark . 43 90.17.7.7:Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589 / Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required :100 Mm Dia 44 90.17.19.1:Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd. For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Apr-2023 Insufficient Time Date 17-04-2023

Key Value

Document Fees
INR 555 /-
EMD
INR 6223.0 /-
Tender Value
INR 2.48 Lakhs /-

BOQ Items

Work Name:Annual Plan-Installation of fire saftey equipments in MCF and RRF -Installation of fire saftey equipments in MCF and RRF at Parakkod in Adoor Muncipality-General Electrical Work
Sl. No. Item Description
1Part 1-Electrification-List of materials attached seperately
2OD322619/2022-2023:Supply and installation of dust and Vermin proof wall mounting meter box (450x375x200mm )SINTEX make(GSMB-4537) with base plate suitable to fix single phase energy meter and HRC fuse units and neutral link on wall using suitable nut bolt etc.
3OD322620/2022-2023:63 A, 2 Way neutral links mounted on DMC/SMC base
4OD322805/2022-2023:Supply and providing 63, HRC Fuse Base with suitably ratedlink
590.11.1.14:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
62.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
72.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
82.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
92.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
102.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1190.2.2.4:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
1290.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
13OD399135/2022-2023:Supplying and providing extra length of conduit downrod with 15 mm dia B class GI pipe1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
14OD399136/2022-2023:Supply and installation of 1200mm sweap ceiling fan with standard accessories with out reglator including giving connection with 16/0.20 mm 3core round copper conductor flexible chord etc as required.(Crompton (High speed)/Havells(thril/Aero)
1590.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1690.17.4.2:Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-"F" insulation, conforming to IS-325. c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head
1714.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
1814.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
1990.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
20OD393709/2022-2023:Supply, installation testing and commissioning of wall mounted cubicle type switch board of suitable size made out of 2 mm thick MS Sheet totally enclosed, dust and vermin proof with an additional lockable glazed door on the front and consisting of the following items such as 1 no 32 Amps TPN Switch fuse unit with HRC fuses, 1 no DOL starter suitable for the pump set, 0-30 amps ammeter with CTs, selector switch - 1 set,0-500V Voltmeter with selector switch - 1 set,3 Phase indication lamps 1 set etci/c connections with suitable copper conductor cable, earthing, painting (red), lettering etc. as required.
211.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
221.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
231.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
241.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
251.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
261.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2790.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
2890.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
299.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
309.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
315.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
325.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
3390.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
345.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
3590.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3690.16.2.1:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
3790.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
38OD322814/2022-2023:Supply and providing 25x6 mm brass nut and bolt with washers in position including drilling holes
39OD322623/2022-2023:Charges for preparation of KSEB service connection documents for availing three phase service connection and producing to the consumer including test report drawing etc.
40OD400017/2022-2023:Supply and installation, testing and commissioning of portable fire extinguisher complete withinstallation brackets confming toIS15683 with ISI mark BIS 2190 and BIS: 15683:2006 and with relevant ISS Stamping/Marking.CO2
41OD400018/2022-2023:Charges for preparation ofdocuments for availing fire NOC from concerned department and producing to the consumer including test report drawing etc
42OD400019/2022-2023:Supply and installation of ABC type fire extinguisher of 4 kg. Capacity complete with initial charges and installation brackets confming toIS15683 with ISI mark .
4390.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
4490.17.19.1:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe