Work Of Erection Of 132 Kv Kosi Kalan Upsidc - Air Liquid Line On Dc Tower Including Supply Of Tower Parts And Accessories And Construction Of 132 Kv Bay Including Supply Of Material Under Etd Mathura, mathura-Uttar Pradesh

Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Work Of Erection Of 132 Kv Kosi Kalan Upsidc - Air Liquid Line On Dc Tower Including Supply Of Tower Parts And Accessories And Construction Of 132 Kv Bay Including Supply Of Material Under Etd Mathura. Submission Date for this Tender is 11-04-2023. Bolts Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37044826
Work Of Erection Of 132 Kv Kosi Kalan Upsidc - Air Liquid Line On Dc Tower Including Supply Of Tower Parts And Accessories And Construction Of 132 Kv Bay Including Supply Of Material Under Etd Mathura
Open Tender
Indian
Uttar Pradesh
mathura
11-04-2023

Tender Details

Work Of Erection Of 132 Kv Kosi Kalan Upsidc - Air Liquid Line On Dc Tower Including Supply Of Tower Parts And Accessories And Construction Of 132 Kv Bay Including Supply Of Material Under Etd Mathura-2 Tower Fabricationincluding ( Stubs, Extension, Templates ) 3 Nut&Bolt Hdg 4 Tower Accessories 5 Number Plate 6 Danger Plate 7 Phase Plate In Sets Of Red, Blue And Yellow For Tension Towers 8 Pipe Type Earthing Material For Towers 9 Insulator 10 120 Kn Polymer Insulator 11 Hardwares Suitable For Acsr Panther 12 Single Tension Fittings 13 Double Tension Fittings 14 Conductor Accessories Suitable For Acsr Panther 15 Vibration Dampers 16 Mid Span Compression Joint 17 Repair Sleeves 18 Opgw 19 24 Fibre ( Dwsm ) Opgw Fibre Optic Cable 20 Supply & Installation Of Hardware Set For 24 Fibre Opgw* 21 Joint Box ( 48 ) Fibre 22 Fodp 96F 23 Fibre Optic Approach Cable For 48 F Opgw 24 Supply & Installation Of Hardware Setfor 48 Fibre ( Dwsm, G652d ) Fibre Optic Approach Cable* 25 Supply Of Material For Construction 132 Kvbay :- 26 Supply Of Bolted Type Bus Bar Tension Fitting Suitable For Moose Conductor Made Of Lm-6 Alloy Complete With Ball Eye Socket And ‘D’ Shackle Single Phase. 27 Supply Of Bolted Type Bus Bar Tension Fitting Suitable For Acsr Panther Conductor Made Of Lm-6 Alloy Complete With Ball Eye Socket And ‘D’ Shackle Single Phase Type Turn Buckle In All Respect. 28 Supply Of P.G. Clamp Made Of Lm-6 Alloy Along With Galv. Nut, Bolt & Washer Suitable For Moose To Panther Conductor. 29 Supply Of P.G. Clamp Made Of Lm-6 Alloy Along With Galv. Nut, Bolt & Washer Suitable For Panther To Panther Conductor. 30 Supply Of P.G. Clamp Made Of Lm-6 Alloy Along With Galv. Nut, Bolt & Washer Suitable For Moose To Moose Conductor. 31 Supply Of 145 Kv Insulator Bus Postclamp Made Of Lm-6 Alloy Along With Nut, Bolt & Washer Suitable For Panther Conductor. 32 Supply Of Suspension Fitting Suitable For Moose Conductor Made Of Lm-6 Alloy Complete With Ball Eye Socket And ‘D’ Shackle Single Phase. 33 Supply Of Suspension Fitting Suitable For Panther Conductor Made Of Lm-6 Alloy Complete With Ball Eye Socket And ‘D’ Shackle Single Phase. 34 Supply Of Tinned Copper Bond Size 15X550mm Long Made Of 12Mm Multi Stranded Rope Type 450Mm Long Should Be Joined Together And Cramped With Copper Lug ( 20Mm Hole ) On Both Ends As Per Sample 35 Supply Of Earthing / Discharge Rod Of First Class Insulation For System Voltage Upto 400 Kvhaving Total Height As 7200Mm ( 24’ ) One Set Consisting Following Items. ( A ) Earthing Pole 6.5Mtr. Long In Four Pieces Made Of Epoxy Bonded Glass Fiber. ( B ) Earthing Cable 12Mtr. Long With Transparent Pvc Insulated 12 Mm2 Dia Flexiblity Copper Wire Fitted With Line End Earthing Clamp Of All Alloy Suitable For 4” Ips Tubemoose / Zebra Conductor. ( C ) Canvas Carry Bag For Above. 36 Work Of Erection Of Line:- 37 Survey Including Preparation Of Schedule Of Materials, Marking Of Locations ( Route Length ) , Gps Survey Of Line With Co-Ordinates Of Each Tower ( The Length Of Line Shall Be Authenticated By Gps Survey ) 38 Check Survey 39 Cost Of Excavation Of 132 Kv Tower Foundation Pits Including All Earth Work, Backfilling, Levelling Etc. 40 Setting Of Stubs Including All Foundation Work But Excludingthe Cost Of Concerting And Excavation ( Rate Per Location ) For Followingtowers : 41 132 Kv Dc / De 42 Cost Of Concreting For All Types Of Tower Foundation Including Cost Of Cement, Dewatering, Shoring And Shuttering, Forming, Curing But Excluding Cost Of Reinforcement Bars 43 1:2:4 Concreting 44 Erection Of Superstructure Of 132Kv Towers And Anchor Towerand Their Extensions Wherever Required Including All Work Above Ground Level Excluding Hoisting Of Insulators, Hardware & Accessories, Butincluding Fitting Of Danger Number, Phase Plates, Bird Guard And Fixing & Punching For 132Kv Sc / Dc Lines 45 Tack Welding Of All The Boltsup To The Heightof One Section Of The Tower Or5 Meterfrom Ground Level Whichever Is Higherwith Threetacks At 1200Seperatiion Of Minimum 10 Mm Thickness With 10Mm / 12 Mm Electrode &Applicationof Zinc Rich Aluminium Paint On The Affectedsurfaceincludingcost Of Allmaterial Includingtack Welding Of Rivercrossingtower & Anchor Towers. 46 Laying, Stringing, Tensioningclamping, Jointing Etc Ofacsr ‘Panther’ Conductorincludinghoistingof Insulators , Fitting Of All Necessary Hardware And Accessories I.E.Fittings Armour Rods, Vibration Dampers Etc.On All Three Phases Of 132 Kv Sc Lines 47 Laying, Stringing, Tensioningclamping, Jointing, Including Fittings Of All Necessary Hardware And Accessories Of Opgw & Ofac, Termination At S / S, End To End Connectivity & Testing Etc On 132 Kv & 220 Kv Lines. 48 ( A ) Groundingwork Includingearth Worketc Forpipetypegroundingincludingcost Of Coke & Salt. 49 Installation Of Steel Reinforcementbars In R.C.C. Foundation Includingcost Of Steel Reinforcement Bars With Cutting, Bending, Placing, Binding Etc. 50 Construction Work Of 132Kv Bay:- 51 Erection Of Main And Auxiliary Structure Consisting Of Columns, Beams, Peaks, Masts Etc. Structure Required For Installation Of Main / Transfer Bus, Jack Busbar, Isolators, P.I., Cts., L.As. And All Other Equipments. The Job Consists Of Shifting Of All Material I.E. Conductor, Fittings, Structure Parts, Nuts, Bolts, Washer Etc. From Store To Site Of Erection, Erection Of Structure As Per Relevant Drawing And Practices Using Flat And Spring Washer With Each Bolt. Matching Of Holes, Cutting, Matching Of Members If Required Shall Also Be Done By The Contractor Without Any Extra Cost To Complete The Work Satisfactorily. All Material To Be Erected Shall Be Supplied By Upptcl Free Of Cost But All Men, Material And T&P Required For Satisfactorily Completion Of Work Shall Be Arranged By The Contractor At His Own Cost. 52 Erection Of Following Equipments As Per Instruction Manual Of Various Equipments And Technical Specifications Including Shifting Of Material / Equipments From Store To Erection Site Including All Other Associated Work To Complete The Job Satisfactorily. 53 132 Kv Cb Sf6 54 132 Kv Bi / Li 55 132Kv Pt Junction Box 56 132Kv Pt 57 132 Kv Ti 58 132 Kv Ct 59 132 Kv Ctjunction Box 60 132 Kv La 61 132 Kv Pi 62 132 Kv Sas Line Feeder Panel 63 Abt With Energy Meter 64 De-Stringing Of Various Main, Transferbus Of 132 Kv With Different Type Conductor And Different Length Of Span Mention Below Including De-Fitting Of Tension Clamp De-Hoisting Of Insulators And Also Shifting Of All Material Form Site To Store And All Other Associated Works Required For Completion Of Job Satisfactorily As Per Technical Specification. 65 132 Kv Over Head Jack Bus With 3X Panther ( Approx 36Mtr Section ) 66 Stringing Of Various Main, Transferbus Of 132 Kv With Different Type Conductor And Different Length Of Span Mention Below Including Fitting Of Tension Clamp Hoisting Of Insulators Cutting Of Conductor And Also Shifting Of All Material Form Store To Work Site And All Other Associated Works Required For Completion Of Job Satisfactorily As Per Technical Specification. 67 132 Kv Over Head Jack Bus With 3X Panther ( Approx 36Mtr Section ) 68 132 Kv Main Bus 3X Moose ( Approx 15 Mtr Section ) 69 132 Kv Transfer Bus With 3X Panther ( Approx 12 Mtr Section ) 70 Dismantling Of Exisiting Jumpers Of 132 Kvc.B. C.T. Isolator And La Made Of Single Moose / Zebra / Panther Conductor With Bending And Shaping Of Conductor Along With Shifting Of Material From Site To Store. 71 Making Of New Jumpers Of 132 Kvc.B., C.T., , Isolator And La By The Single Moose / Zebra / Panther Conductor With Cutting Bending And Shaping Of Conductor Along With Shifting Of Material From Site Store To Work Place. 72 Providing Inter Connection Diagram And Cable Schedule As Per Drawing To Complete Job Including C.B., C.T., Pt., Isolator, Panel Etc For Proper Wiring And Commisioning Of Bay. 73 Laying Of Following Sizes Of Control Cable In The Cable Trench From Control Relay Panel To Various Equipments / Marshalling Boxes / Junction Box Etc. In Switchyard As Per Cable Schedule, Their Saddling At Every 750Mm Distance With M.S. Saddles Of Size 25X3mm Size Including Carriage Of Cable Drums From Store To Laying Site And Shifting Back The Remaining Material To Store And All Other Associated Work To Complete The Job Satisfactorily As Per Technical Specification. 74 6X2.5 Sq. Mm. 75 4X2.5 Sq. Mm. 76 2X2.5 Sq. Mm. 77 Termination Of Following Sizes Of Cable As Laid Above As Per Cable Schedule Including Making Necessary Holes In Glands Plates Or Box Wherever Required. Supply And Fixing Of Cable Glands Of Appropriate Size, Supply And Providing Ferrules And Nos. For Each Core. ( The Rates Of Termination Of Control Cable Include The All Cores Of Cable At One End With Lug ) 78 6X2.5 Sq. Mm. 79 4X2.5 Sq. Mm. 80 2X2.5 Sq. Mm. 81 Cutting, Straightening Bending & Laying 800Mm Below Inside Ground And Above Ground Of Following Size M.S. Flat For Earthing Of Main And Auxiliary Structure, Equipment Structure Etc. Including Welding With Main Earthmat And With Object To Be Earthed Excavation Of Trenches, Its Back Filling, Painting And All Other Associated Work As Required To Complete The Work Satisfactorily Excluding The Cost Of M.S. Flat. 82 75X10mm 83 50X6mm 84 25X6mm 85 To Make Earthing For L.A. With 06 Nos. Electrode Of 03 Meter Long M.S. Round Including Cutting, Welding And Making Electrode And Making A Rectangle With 75X10mm M.S. Flat Inside Earth Below 0.8Mtr. Deep Including Excavation And Refilling Of Soil With T&P And Labour Etc For Completion Satisfactorily. 86 132 Kv L.A. 87 Laying Of 40 / 36 Mm Size M.S. Round Bar 600 Mm Below Ground Level Including Cutting, Straightening Welding, Painting Of Joints With Bitumen Black Japan Paint, Excavation Of Trench, Its Back Filling And All Other Associated Work To Complete The Work Satisfactorily As Per Drawing And Technical Specification ( Excluding The Cost Of Ms Bar ) Work Includes Providing And Fixing Of 100 Mm Long, 50X50x6 Mm Ms Angle ( 4 Pcs ) At Each Cross Joint Of Earth Mat As Per Direction Of Supervising Engineer To Complete The Job Satisfactorily. 88 Fabrication Of 3 Meter Long Electrodes With The 40 Mm / 36Mm Ms Rod Having 150 Mm Long Conical Shape And Then Its Piercing Vertically Inside The Ground With Top 600 Mm Below Ground Level And Its Welding With Main Earthmat Excluding The Cost Of Ms Bar, Providing Anf Fixing 50X50x6 Angle 100 Mm Pieces For Each Joints As Per Direction Of Supervising Engineer To Complete The Job Satisfactory. 89 Sorting / Counting / Stacking Erection Mark Wise And Proper Loading Ofgisubstation Structure ( Alp, Abl, Bct, Axm, Btm, Atm, Bbl, Bti, ) Etc. In Trucks / Trailor At Efu Nainy Allahabad And Safe Carriage Of Loaded Structure From Efu Nainy Allahabad To 132 Kv S / S Kosikalan Upsidc Under Etd Mathura. App. 600 Km And Unloading Of Carriage Structure From The Trucks / Trailor At132 Kv S / S Kosikalan Upsidc Under Etd Mathura.Its Sorting, Counting And Proper Stacking At The S / S Premises As Per Direction Of Supervisory Engineer To Complete The Job Satisfactorily ( Appr. Weight Of 13 Mt ) 90 Providing And Fixing Of Retro Reflective Sign Board Of Size 3Ftx2ft Made Out Of 2Mm Thick Aluminum Sheet, Face To Fully Covered With 3M Dg Cube Retro Reflective Sheet Of Green Colour. The Letters And Symbols Shall Be Computer Cut And In White Colour. Board Is To Be Supplied Along With The Back Support From Of Size 35X35x5mm & Two Legs For Grouting. Backside Of Aluminum Sheet Shall Be Painted With Stove Enamel Black Paint. Language For Writing Will Be Provided By The Department ( Upptcl ) . 91 Fabrication Of Hut Type Fire Bucket Stand Made Of Ms Angle Of Size 40X40x6 Mm And Isi Mark Ms Roofing Sheet, Having Arrangment For Hanging 10 Buckets. All The Metal Surfaces Should Be Painted With One Coat Of Red Oxide And Two Coats Of First Quality Post Office Red Synthetic Enamel Paint Of Asian Paints / Nerolac / Berger. Fire In 25 Cm Should Be Written In White Color On The Top Of The Both Side Of Roof After Painting In Red Colour. All The Material Including Ms Angle Shall Be Provided By The Contractor At His Own Cost. 92 Providing Fire Buckets Of 9 Ltr Capacity As Per Is 2546, Buckets Should Be Painted Inside By White And Outside By Post Office Red Colour; Ear And Handle By Black Color With Two Coats Of First Quality Synthetic Enamel Paint Afterone Coat Of Red Oxide, From Asian Paints / Nerolac / Berger. Fire And Agni ( Hindi ) In 10 Cm Font In White Color Should Be Written On Opposite Sides Of Buckets. All The Material Shall Be Provided By The Contractor At His Own Cost. 93 Work Of Strengthening Of Lighting Arrangement:- 94 Supply & Fixing Of Round Pole Of Ms Pipe B Class 9 Meter Long ( 114.3 Mm X4.5Mm X5meter 88.9 Mm.X3 65Mm X2.0 Meter, 76.1Mm X3.2Mm X2meter ) With Base Plate Work Induded Duly Bainted With Synthetic Aluminium Enamel Paint Completely As Outer Surface Of Ms Round Pole And Grouting With Plinth Size 300Mm Duly Earth With Ms Electrode And All Other Associated Work To Complete The Job Satisfactory As Per Direction Of Supervising Engineer. 95 Supply & Fixing Of Pole Bracet Of 2 Dia Ms Pipe Of B Class ( Id 50Mm Od 60Mm. ) 1 2 Meter Long Filled At Angle Of 30 Degree Suitable At 100 W Led Luminaries And All Other Associated Work To Complete The Job Satisfactory As Per Direction Of Supervising Engineer. 96 Supply & Fixing Of 100 Watt Led Lamp Crompton Greaves / Bajai / Syska / Philips Make Fiting Including Lamp And All Fixtures Etc. For Fixing Of Round Pole Including Cost Of All Meterial Labour And T&P For Completion Of Work. And All Other Associated Work To Complete The Job Satisactory As Per Direction Of Supervising Engineer. 97 Supply Of Fixing Of Junction Box On Lighting Poles Of Sive 200X200x150 Mm Of Ms Sheet 16 Swg Duly Painted With Synthetic Enamel Paint Box Should Be Fixed With 01 No 6Amp Mcb And Backlite Terminal Surip Of 4 Nos Terminal Both Should Be Fixed On Sunmica Sheet And Half Round M.S. Clamp With Gl Pipe For Fixing The Junction Box On The Pole And All Other Associated Work To Complete The Job Satisfactory As Per Direction Of Supervising Engineer. 98 Laying Of 4X2.5 / 6X2.5 Sqmm Pvc Cable 50Cm. Blow The Ground Level In Pvc Conduct Pipe Afler Exavation And Back Fitling Including All Labor Pvc Pipe Etc And All Other Associated Work To Complete The Job Satisfaclory As Per Direction Of Supervising Engineer. 99 Laying Of 2X2.5 Sqmm Pvc Cable From Fitting To Junction Box Inside The Pole And All Other Associated Work To Complete The Job Satisfactory As Per Direction Of Supervising Engineer.

Key Value

Document Fees
INR 1770 /-
EMD
INR 110000.0 /-
Tender Value
INR 1.09 Crore /-

BOQ Items

Name of Work:Work of Erection of 132 KV Kosi Kalan(UPSIDC) – Air Liquid Line On DC Tower including supply of Tower Parts & Accessories and construction of 132 KV Bay including supply of Material Under ETD Mathura.
Sl. No. Item Description
1Supply of Tower Parts and Accessories:-
2TOWER FABRICATIONINCLUDING(STUBS,EXTENSION,TEMPLATES)
3NUT&BOLT HDG
4TOWER ACCESSORIES
5Number Plate
6Danger Plate
7Phase plate in sets of red,blue and yellow for Tension towers
8Pipe type earthing material for towers
9Insulator
10120 KN Polymer Insulator
11HARDWARES SUITABLE FOR ACSR PANTHER
12Single Tension fittings
13Double tension fittings
14CONDUCTOR ACCESSORIES SUITABLE FOR ACSR PANTHER
15Vibration Dampers
16Mid Span compression joint
17Repair sleeves
18OPGW
1924 Fibre (DWSM)OPGW Fibre optic cable
20Supply & Installation of hardware set for 24 fibre OPGW*
21Joint Box (48)fibre
22FODP 96F
23Fibre Optic Approach cable for 48 F OPGW
24Supply & Installation of hardware setfor 48 fibre (DWSM, G652D) Fibre optic Approach Cable*
25Supply of material for construction 132 KVBay :-
26Supply of Bolted type bus bar tension fitting suitable for Moose conductor made of LM-6 alloy Complete with ball eye socket and ‘D’ shackle single phase.
27Supply of Bolted type bus bar tension fitting suitable for ACSR Panther conductor made of LM-6 alloy Complete with ball eye socket and ‘D’ shackle single phase type turn buckle in all respect.
28Supply of P.G. clamp made of LM-6 alloy along with Galv. nut, bolt & washer suitable for Moose to Panther conductor.
29Supply of P.G. clamp made of LM-6 alloy along with Galv. nut, bolt & washer suitable for Panther to Panther conductor.
30Supply of P.G. clamp made of LM-6 alloy along with Galv. nut, bolt & washer suitable for Moose to Moose conductor.
31Supply of 145 KV Insulator Bus Postclamp made of LM-6 alloy along with Nut, Bolt & washer suitable for Panther conductor.
32Supply of suspension fitting suitable for Moose conductor made of LM-6 alloy Complete with ball eye socket and ‘D’ shackle single phase.
33Supply of suspension fitting suitable for Panther conductor made of LM-6 alloy Complete with ball eye socket and ‘D’ shackle single phase.
34Supply of tinned copper bond size 15x550mm long made of 12mm multi stranded rope type 450mm long should be joined together and cramped with copper lug (20mm hole) on both ends as per sample
35Supply of Earthing/Discharge rod of first class insulation for system voltage upto 400 KVhaving total height as 7200mm (24’) one set consisting following items. (a) Earthing pole 6.5Mtr. long in four pieces made of epoxy bonded glass fiber. (b) Earthing cable 12mtr. long with transparent PVC insulated 12 mm2 dia flexiblity copper wire fitted with line end earthing clamp of all alloy suitable for 4” IPS tubeMoose/Zebra conductor. (c) Canvas carry bag for above.
36Work of Erection of Line:-
37Survey including preparation of schedule of materials, marking of locations (Route length),GPS Survey of line with co-ordinates of each tower(The length of line shall be authenticated by GPS Survey)
38Check survey
39Cost of excavation of 132 KV tower foundation pits including all earth work,backfilling, levelling etc.
40Setting of stubs including all foundation work but excludingthe cost of concerting and excavation (Rate per location) for followingtowers :
41132 KV DC/DE
42Cost of concreting for all types of tower foundation including cost of cement,dewatering,shoring and shuttering,forming,curing but excluding cost of reinforcement bars
431:2:4 concreting
44Erection of Superstructure of 132KV Towers and Anchor towerand their extensions wherever required including all work above ground level excluding hoisting of insulators, hardware & accessories, butincluding fitting of danger number,phase plates, bird guard and fixing & punching for 132KV SC/DC lines
45Tack welding of all the boltsup to the heightof one section of the tower or5 meterfrom ground level whichever is higherwith threetacks at 1200seperatiion of minimum 10 mm thickness with 10mm/12 mm electrode &applicationof Zinc rich Aluminium paint on the affectedsurfaceincludingcost of allmaterial includingtack welding of RiverCrossingtower & Anchor towers.
46Laying, stringing, tensioningclamping, jointing etc ofACSR ‘Panther’ conductorincludinghoistingof insulators , fitting of all necessary hardware and accessories i.e.fittings Armour rods, vibration dampers etc.on all three phases of 132 KV SC lines
47Laying, stringing, tensioningclamping, jointing, including fittings of all necessary Hardware and accessories of OPGW & OFAC, termination at S/s, end to end connectivity & testing etc on 132 KV & 220 KV lines.
48(a)Groundingwork includingearth worketc forpipetypegroundingincludingcost of coke & salt.
49Installation of steel reinforcementbars in R.C.C. foundation includingcost of steel reinforcement bars with cutting, bending, placing, binding etc.
50Construction work of 132KV Bay:-
51Erection of main and auxiliary structure consisting of columns, beams, peaks, masts etc. structure required for installation of Main /Transfer bus, Jack busbar, isolators, P.I., CTs., L.As. and all other equipments. The job consists of shifting of all material i.e. conductor, fittings, structure parts, nuts, bolts, washer etc. from store to site of erection, erection of structure as per relevant drawing and practices using flat and spring washer with each bolt. Matching of holes, cutting, matching of members if required shall also be done by the contractor without any extra cost to complete the work satisfactorily. All material to be erected shall be supplied by UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost.
52Erection of following equipments as per instruction manual of various equipments and technical specifications including shifting of material/equipments from store to erection site including all other associated work to complete the job satisfactorily.
53132 KV CB SF6
54132 KV BI/LI
55132KV PT Junction box
56132KV PT
57132 KV TI
58132 KV CT
59132 KV CTjunction box
60132 KV LA
61132 KV PI
62132 KV SAS LINE Feeder panel
63ABT with energy meter
64De-Stringing of various main, Transferbus of 132 KV with different type conductor and different length of span mention below including de-fitting of tension clamp de-hoisting of insulators and also shifting of all material form site to store and all other associated works required for completion of job satisfactorily as per technical specification.
65132 KV over head Jack Bus with 3x Panther (Approx 36Mtr section)
66Stringing of various main, Transferbus of 132 KV with different type conductor and different length of span mention below including fitting of tension clamp hoisting of insulators cutting of conductor and also shifting of all material form store to work site and all other associated works required for completion of job satisfactorily as per technical specification.
67132 KV over head Jack Bus with 3x Panther (Approx 36Mtr section)
68132 KV Main Bus 3x Moose (Approx 15 Mtr section)
69132 KV Transfer Bus with 3x Panther (Approx 12 Mtr section)
70Dismantling of exisiting jumpers of 132 KVC.B. C.T. Isolator and LA made of single Moose/Zebra/Panther conductor with bending and shaping of conductor along with shifting of material from site to store.
71Making of new jumpers of 132 KVC.B., C.T., ,Isolator and LA by the single Moose/Zebra/Panther conductor with cutting bending and shaping of conductor along with shifting of material from site store to work place.
72Providing inter connection diagram and cable schedule as per drawing to complete job including C.B., C.T., PT., Isolator, Panel etc for proper wiring and commisioning of bay.
73Laying of following sizes of control cable in the cable trench from control relay panel to various equipments/marshalling boxes/junction box etc. in switchyard as per cable schedule, their saddling at every 750mm distance with M.S. saddles of size 25x3mm size including carriage of cable drums from store to laying site and shifting back the remaining material to store and all other associated work to complete the job satisfactorily as per technical specification.
746x2.5 Sq. mm.
754x2.5 Sq. mm.
762x2.5 Sq. mm.
77Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box wherever required. Supply and fixing of cable glands of appropriate size, supply and providing ferrules and Nos. for each core. (The rates of termination of control cable include the all cores of cable at one end with lug)
786x2.5 Sq. mm.
794x2.5 Sq. mm.
802x2.5 Sq. mm.
81Cutting, straightening bending & laying 800mm below inside ground and above ground of following size M.S. flat for earthing of main and auxiliary structure, equipment structure etc. including welding with main earthmat and with object to be earthed excavation of trenches, its back filling, painting and all other associated work as required to complete the work satisfactorily excluding the cost of M.S. flat.
8275x10mm
8350x6mm
8425x6mm
85To make earthing for L.A. with 06 Nos. Electrode of 03 meter long M.S. round including cutting, welding and making electrode and making a rectangle with 75x10mm M.S. flat inside earth below 0.8mtr. deep including excavation and refilling of soil with T&P and labour etc for completion satisfactorily.
86132 KV L.A.
87Laying of 40/36 mm size M.S. round bar 600 mm below ground level including cutting, straightening welding, painting of joints with bitumen black Japan paint, excavation of trench, its back filling and all other associated work to complete the work satisfactorily as per drawing and technical specification (excluding the cost of MS bar) work includes providing and fixing of 100 mm long, 50X50X6 mm MS angle (4 Pcs) at each cross joint of earth mat as per direction of supervising engineer to complete the job satisfactorily.
88Fabrication of 3 meter long Electrodes with the 40 mm/36mm MS rod having 150 MM long conical shape and then its piercing vertically inside the ground with top 600 mm below ground level and its welding with main earthmat excluding the cost of MS bar, providing anf fixing 50x50x6 angle 100 mm pieces for each joints as per direction of supervising engineer to complete the job satisfactory.
89Sorting/counting/stacking erection mark wise and proper loading ofGIsubstation structure ( ALP, ABL, BCT,AXM, BTM, ATM, BBL, BTI, ) etc. in trucks / trailor at EFU Nainy Allahabad and Safe carriage of loaded structure from EFU Nainy Allahabad to 132 KV S/S kosikalan UPSIDC Under ETD Mathura. App. 600 Km and Unloading of carriage structure from the trucks/trailor at132 KV S/S kosikalan UPSIDC Under ETD Mathura.Its sorting, counting and proper stacking at the S/S premises as per direction of supervisory engineer to complete the job satisfactorily (Appr. weight of 13 MT)
90Providing and fixing of retro reflective sign board of size 3ftx2ft made out of 2mm thick aluminum sheet, face to fully covered with 3M DG cube retro reflective sheet of green colour. The letters and symbols shall be computer cut and in white colour. Board is to be supplied along with the back support from of size 35x35x5mm & two legs for grouting. Backside of aluminum sheet shall be painted with stove enamel black paint. Language for writing will be provided by the department (UPPTCL).
91Fabrication of hut type fire bucket stand made of MS angle of size 40x40x6 mm and ISI mark MS roofing sheet, having arrangment for hanging 10 buckets. All the metal surfaces should be painted with one coat of red oxide and two coats of first quality post office red synthetic enamel paint of Asian Paints/Nerolac/Berger. " FIRE" in 25 cm should be written in white color on the top of the both side of roof after painting in red colour. All the material including MS angle shall be provided by the contractor at his own cost.
92Providing fire buckets of 9 ltr capacity as per IS 2546, buckets should be painted inside by white and outside by post office red colour; ear and handle by black color with two coats of first quality synthetic enamel paint afterone coat of red oxide, from Asian Paints/Nerolac/Berger. "FIRE" and "AGNI (Hindi)" in 10 cm font in white color should be written on opposite sides of buckets. All the material shall be provided by the contractor at his own cost.
93Work of Strengthening of Lighting Arrangement:-
94Supply & fixing of round pole of MS pipe B class 9 meter long (114.3 mm x4.5mm x5meter 88.9 mm.x3 65mm x2.0 meter, 76.1mm x3.2mm x2meter) with base plate work induded duly bainted with synthetic Aluminium enamel paint completely as outer surface of ms round pole and grouting with plinth size 300mm duly earth with MS electrode and All other associated work to complete the job satisfactory as per direction of supervising Engineer.
95Supply & fixing of pole bracet of "2" dia MS pipe of B Class (ID 50mm OD 60mm.)1 2 meter long filled at angle of 30 degree suitable at 100 W LED luminaries and All other associated work to complete the job satisfactory as per direction of supervising Engineer.
96Supply & fixing of 100 watt LED Lamp Crompton Greaves /Bajai/Syska/Philips make fiting including lamp and all fixtures etc. for fixing of round pole including cost of all meterial labour and T&P for completion of work. and All other associated work to complete the job satisactory as per direction of supervising Engineer.
97Supply of fixing of junction box on lighting poles of sive 200x200x150 mm of MS sheet 16 SWG duly painted with synthetic enamel paint box should be fixed with 01 No 6Amp MCB and backlite terminal surip of 4 Nos terminal both should be fixed on sunmica sheet and half round M.S. Clamp with Gl pipe for fixing the junction box on the pole and All other associated work to complete the job satisfactory as per direction of supervising Engineer.
98Laying of 4x2.5/6x2.5 sqmm PVC cable 50cm. Blow the ground level in PVC conduct pipe afler exavation and back fitling including all labor PVC pipe etc and All other associated work to complete the job satisfaclory as per direction of supervising Engineer.
99Laying of 2x2.5 Sqmm PVC cable from fitting to junction box inside the pole and All other associated work to complete the job satisfactory as per direction of supervising Engineer.