| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 manufactured sand derived from Recycled concrete aggregate (RCA) : 8 graded stoneaggregate 40 mm nominal size Recycled aggregate (RA) |
| 3 | Filling available excavated earth (excluding rock) in trenches,plinth, sides of foundations etc. in layersnot exceeding20cm in depth, consolidating each deposited layer byramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position specified grade of reinforcedcement concrete, excluding the cost of centering,shuttering, ifnishing and reinforcement- All work up toplinth level :1:2:4 (1 cement : 2 coarse sand including manufactured sand derived from Recycled concrete aggregate (RCA) upto 20% : 4 graded stone aggregate 20 mm nominal size ofRecycled concrete aggregate (RCA) upto 20%). |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand including manufactured sand derived from Recycled concrete aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled concrete aggregate (RCA) upto 20%. |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and accessplatform |
| 11 | Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars |
| 12 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 13 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 14 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 15 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 16 | Structural steel work in single section, fixed with or withoutconnecting plate, including cutting, hoisting, fixing inposition and applying a priming coat of approved steelprimer all complete. |
| 17 | Providing and fixing ISI marked flush door shuttersconforming to IS : 2202 (Part I) non-decorative type, coreof block board construction with frame of 1st class hardwood and well matched commercial 3 ply veneering withvertical grains or cross bands andface veneers on bothfaces of shutters: 35 mm thick including ISI marked Stainless Steel butthinges with necessary screws |
| 18 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) |
| 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 20 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 21 | Providing and laying vitrified floor tiles Size of Tile 600x600 mmin different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 22 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 23 | Finishing with Deluxe Multi surface paint system forinteriors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 24 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 25 | Providing and fixing in position collapsible steel shutterswith vertical channels 20x10x2 mm and braced with flatiron diagonals 20x5 mm size, with top and bottom rail of Tiron40x40x6 mm, with 40 mm dia steel pulleys, completewith bolts, nuts, locking arrangement, stoppers, handles,including applying a priming coat of approved steel primer |
| 26 | Making plinth protection 50mm thick of cementconcrete 1:3:6 (1 cement : 3 manufactured sand derivedfrom Recycled concrete aggregate (RCA) : 6 graded stoneaggregate 20 mm nominal size Recycled aggregate (RA)over 75mm thick bed of dry brick ballast 40 mm nominalsize, well rammed and consolidated and grouted with finesand, including necessary excavation, leveling &dressing& finishing the top smooth |
| 27 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 28 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 29 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 31 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 32 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 33 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required |
| 34 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thickincluding accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required |