}

Tender For Annual Rate Contract For Supply Of Earc Gland Packing (Critical) At Rcf Trombay Unit., chembur-Maharashtra

Rashtriya Chemicals And Fertilizers Limited-RCF has published Tender For Annual Rate Contract For Supply Of Earc Gland Packing (Critical) At Rcf Trombay Unit.. Submission Date for this Tender is 05-04-2023. Miscellaneous Fasteners Tenders in chembur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

36948022
Tender For Annual Rate Contract For Supply Of Earc Gland Packing (Critical) At Rcf Trombay Unit.
Open Tender
Indian
Maharashtra
chembur
05-04-2023

Tender Details

Annual Rate Contract For Supply Of Earc Gland Packing ( Critical ) At Rcf Trombay Unit. , Gland Packing A ) Type: High Grade Graphite Fibre Yarn Packing Impregnated With A Special Graphite Mix, In Interlock Braid And Further Reinforced With Inconel Wire. B ) Size: 9 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: Upto 800°C 2 ) Pressure: Upto 8 Bar 3 ) Ph Range: 0-14 D ) Applications: Valves Handling Superheated & Saturated Steam, Hydrocarbon, So2 / So3 / Nox Gases, Ammonia, Acid, Alkalies, Strong Chemicals, Oils & Solvents, Boiler Feed Water & Condensate , Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 & Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300W / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delvered To Rcf. 3 ) Packing Is To Be Supplied In A Continuous Roll Of 3 Kgs Each. , Ready Cut Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size ( Readycut ) : 30 Mm Od X 20 Mm Id X 5 Mm C / S C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packing Shall Be Supplied In Tangentially Machine Cut At 45* , Ready Cut Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size ( Readycut ) : 48 Mm Od X 32 Mm Id X 8 Mm C / S C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packing Shall Be Supplied In Tangentially Machine Cut At 45* , Ready Cut Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size ( Readycut ) : 60Mm Od X 40 Mm Id X 10 Mm C / S C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packing Shall Be Supplied In Tangentially Machine Cut At 45* , Ready Cut Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size ( Readycut ) : 64 Mm Od X 44 Mm Id X 10 Mm C / S C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packing Shall Be Supplied In Tangentially Machine Cut At 45* , Ready Cut Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size ( Readycut ) : 68 Mm Od X 48 Mm Id X 10 Mm C / S C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packing Shall Be Supplied In Tangentially Machine Cut At 45* , Ready Cut Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size ( Readycut ) : 28 Mm Od X 16 Mm Id X 6 Mm C / S C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packing Shall Be Supplied In Tangentially Machine Cut At 45* , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 4 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 6 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 8 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 10 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 12 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 16 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 3 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: Expanded Pure Graphite Braided Packing Reinforced With Multiple Inconnel / Ss Wire Inside Each Yarn And Further Jacketed With High Grade Inconel / Ss Wire Mesh. B ) Size: 5 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: -240 °C To 650°C 2 ) Pressure: 600 Bar 3 ) Ph Range: 0-14 D ) Applications: Valve Handling Superheated & Saturated Steam, Hydrocarbons, Hydrogen, Hot Ash, Solid Catalyst, Dyes & Chemicals, Fuel & Lube Oil, Non Oxidizing Liquid & Gases, Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 / Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300I / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 3 ) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A ) Type: High Grade Graphite Fibre Yarn Packing Impregnated With A Special Graphite Mix, In Interlock Braid And Further Reinforced With Inconel Wire. B ) Size: 6 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: Upto 800°C 2 ) Pressure: Upto 8 Bar 3 ) Ph Range: 0-14 D ) Applications: Valves Handling Superheated & Saturated Steam, Hydrocarbon, So2 / So3 / Nox Gases, Ammonia, Acid, Alkalies, Strong Chemicals, Oils & Solvents, Boiler Feed Water & Condensate , Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 & Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300W / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-Fep Only. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delvered To Rcf. 3 ) Packing Is To Be Supplied In A Continuous Roll Of 3 Kgs Each. , Gland Packing A ) Type: High Grade Graphite Fibre Yarn Packing Impregnated With A Special Graphite Mix, In Interlock Braid And Further Reinforced With Inconel Wire. B ) Size: 12 Mm Sq. Cross-Section C ) Operating Conditions: 1 ) Temperature: Upto 800°C 2 ) Pressure: Upto 8 Bar 3 ) Ph Range: 0-14 D ) Applications: Valves Handling Superheated & Saturated Steam, Hydrocarbon, So2 / So3 / Nox Gases, Ammonia, Acid, Alkalies, Strong Chemicals, Oils & Solvents, Boiler Feed Water & Condensate , Etc. E ) Compliance Standards ( Mandatory ) : 1 ) Fire Test Standard: Api 589 & Api 607. 2 ) Fugitive Emmision Test:Api 622 2Nd Edition / Iso 15848- Part 1 / Mesc 77 / 312 / Equivalent F ) Make & Style Of Gland Packing: Jd Jones ( Pacmaan ) Style ‘Na715’ / James Walker Inmarco Style 100Fxi Special / John Crane Style G85 Iep / Slade Style 3300W / Teadit Style 2236 / Pilot Gasket Style 7310 / Eagleburgmann Style Buratal-Flex 6070 / Garlock Style 1303-FepOnly. Notes: 1 ) Vendor Shall Submit Copy Of Fire Test Report & Fugitive Emission Test Report Of The Gland Packings Along With The Supply. 2 ) Gland Packing Shall Be Properly Packed & Delvered To Rcf.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail