Construction Of Various Office Accommodation In Level 59.00M,Level 62.60M,Level 66.60M, Level 69.80M (4 Floor) Ofexisting Multistoryparkingcomplex Tutikandi At Shimla (Sh:-Providing Fire Alarm And Public Addressing Systemtherein)., shimla-Himachal Pradesh

Public Works Department-PWD has published Construction Of Various Office Accommodation In Level 59.00M,Level 62.60M,Level 66.60M, Level 69.80M (4 Floor) Ofexisting Multistoryparkingcomplex Tutikandi At Shimla (Sh:-Providing Fire Alarm And Public Addressing Systemtherein).. Submission Date for this Tender is 31-03-2023. Fire Alarm Systems Tenders in shimla Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36927520
Construction Of Various Office Accommodation In Level 59.00M,Level 62.60M,Level 66.60M, Level 69.80M (4 Floor) Ofexisting Multistoryparkingcomplex Tutikandi At Shimla (Sh:-Providing Fire Alarm And Public Addressing Systemtherein).
Open Tender
Indian
Himachal Pradesh
shimla
31-03-2023

Tender Details

Construction Of Various Office Accommodation In Level 59.00M, Level 62.60M, Level 66.60M, Level 69.80M ( 4 Floor ) Ofexisting Multistoryparkingcomplex Tutikandi At Shimla ( Sh:-Providing Fire Alarm And Public Addressing Systemtherein ) .

Key Value

Document Fees
INR 2000 /-
EMD
INR 87500.0 /-
Tender Value
INR 43.68 Lakhs /-

BOQ Items

Name of Work: C/O Various Office accommodation in level 59.00M,level 62.60M,level 66.60M, level 69.80M (4 Floor) ofExisting multistoryParkingComplex Tutikandi at Shimla (SH:-Providing Fire Alarm and Public Addressing Systemtherein).
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable 4 loop Main Fire Alarm Control Panel with Suitable Loopsmodules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" ColorLCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Outputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Makes: Bosch FPA 4000 Series / Cerberus by Siemens, Edwards EST3, Honeywell Morley Max Series, Autronica/ Notifire / Bosch/Simens
2Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Autronica/ Notifire / Bosch/Simens
3Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintainingoperational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Autronica/ Notifire / Bosch / Simens -EN
4Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL/EN/VDS Certified. Make Autronica/ Notifire / Bosch/Simens -EN
5Supply, Installation, Testing and Commissioning of Sounder cum strobes with 3 different tone variants selection options & adjustable sound pressure by 3 levels, the sound pressure 92 dB(A), Sounder should have IP40 or better protectionrating. with flasher having Synchronized flash rate of 1 Hz and Light intensity 15cd185cd. Shall be UL/EN/VDS Certified.Make Autronica/ Notifire / Bosch/Simens -EN
6Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL/EN/VDS Certified. Make Autronica/ Notifire / Bosch/Simens -EN
7Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU"s, tripping of AHU"s, Fresh air fans, Ventilation fans, tripping of Access control doorsetc.. Shall be EN54/ Vds Certification/UL Make Autronica/ Notifire / Bosch/Simens -EN
8SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make: Bosch/ Siemens Cerberus/ Morley/ Edward.
9Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Boardphoto luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineerin-Charge of work Make PES/Giolite/OMEX
10Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
12Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 25 mm
13Supply, Installation, Testing and comissioning of 18U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack
14SITC of2KVAOnline UPS :single Phase Input&single Phase Output-Autosensing, True Online UPSwith Full Digital Signal Processing (DSP )Technologieswith Touch Screen LCD /LED Display Panel & Pure Sine Wave O/P with high frequency.UPS unit shall operate in double conversion mode, it shall be a VFI-type UPS (as per stanard IEC 62040-3) withInbuilt /external GalvanicISOLATION Transformer of same OEM make only. UPS should bewith 3 level IGBT Based Rectifier & 3 Level IGBT Based Inverter Technology. UPS should haveminimum 15-60 minutes backupon SMF Batteries Bankwith MinimumVAH= 30200 VAHalong with following features/specifications
15INPUTFEATURE :
16Input Voltage window 180 VAC - 250 VAC 1 Phase
17Input Frequency window 45-65 Hz .
18Nominal Frequency 50 Hz
19OUTPUT FEATURE :
20Output Power Factor should be unity.
21Output Power Capacity in watts (KW)2.0 KW
22Output Voltage - 230/240 Volts rms, adjustable via the user interface.
23Warranty Terms :- 2 Years on UPS & 2 years onBatteries with onsite service Support
24supplying 2.0 KVA on line UPS HAVING SPECIFICATION DETAILED ABOVE (1.01 to 1.06 )OF FOLLOWINGApproved Make :APC- Schneider / Vertiv -Emerson/ Legrand-Numeric /Mitsubishi /GE Only .
25Supply, installation, testing & commissioning of controller unit 16-zone system pre-amplifier, with single or dual channel operation. Input channels for call station , Universal input for microphone/line, with speech optimized tone control , inputs for BGM selection and music optimized tone control , Front panel zone selection for BGM and call station zone selection for calls, S/N (flat at max volume) >63 dB (mic); >70 dB (line), S/N (flat at min volme/muted) >75 dB, CMRR >40 dB (50 Hz – 20 kHz), Line input 3 x, Master output 1 x, Frequency response 50 Hz to 20 kHz (+1 / -3 dB) as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Honeywell/BOSCH/Henrich.
26Supply, installation, testing & commissioning of Class D amplifier 480 watts Frequency response: 60 Hz to 15 khz (+1/3db), Inputs :XLR & phone jack , Input 1, Input 2-4, Impendence :20kO, Sensitivity : 1 V balanced , S/N >: >85 dB as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Honeywell/BOSCH/Henrich.
27Supply, installation, testing & commissioning of Stylish 16-zone call station, 16 zone selection keys, all-call key and momentary PTT-key for calls Selectable gain, speech filter and limiter for improved intelligibility LED indications for zone selection, fault and emergency state Voltage range 18 – 24V Nominal sensitivity 85 dB SPL (gain preset 0dB) Gain preset +6 / 0 / -15 dB Equivalent input noise level 25 dBSPLA Frequency response 100Hz – 16kHz as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Honeywell/BOSCH/Henrich.
28Supply, Installation, Testing & Commissioning of 6W ceiling speaker 5inch with metal enclosure with Line Matching Transformer and tapping of 1.5 W / 3W and 6W as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Bosch / Honeywell / Bose.
29Supply, Installation, Testing & Commissioning of 12W Wall speaker with Line Matching Transformer and tapping of 12 W and 6W as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Bosch / Honeywell / Bose.
30Supply, installation, testing & commissioning of 24 U Standard rack to place all Av equipment as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Valrack/ Comrack/Hive Networks.
31Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 32/50 mm