Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Jsv, Lwsst/Well At Minjgran By Prov. 11/.4 Kv 63 Kva S/Stn.A/W 11 Kv Ht Section Nurpur Under Esd Nurpur Ed Nurpur ( T.S. No. 102/22-23 )(Ii) Tender For Supply, dalhousie-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Jsv, Lwsst/Well At Minjgran By Prov. 11/.4 Kv 63 Kva S/Stn.A/W 11 Kv Ht Section Nurpur Under Esd Nurpur Ed Nurpur ( T.S. No. 102/22-23 )(Ii) Tender For Supply. Submission Date for this Tender is 27-03-2023. Transformer Supply Tenders in dalhousie Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36919054
Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Jsv, Lwsst/Well At Minjgran By Prov. 11/.4 Kv 63 Kva S/Stn.A/W 11 Kv Ht Section Nurpur Under Esd Nurpur Ed Nurpur ( T.S. No. 102/22-23 )(Ii) Tender For Supply
Open Tender
Indian
Himachal Pradesh
dalhousie
27-03-2023

Tender Details

Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Jsv, Lwsst / Well At Minjgran By Prov. 11 / .4 Kv 63 Kva S / Stn.A / W 11 Kv Ht Section Nurpur Under Esd Nurpur Ed Nurpur ( T.S. No. 102 / 22-23 ) ( Ii ) Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Lwss Chhatroli By Prov. 11 / .4 Kv 63 Kva S / Stn. At Chhatroli ( Batu-Ka-Nalah ) A / W 11 Kv Htlinesection Jassure Under Esd Nurpur Ed Nurpur ( T.S. No. 101 / 22-23 ) --- 1 Supply Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 2 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 3 Prov. St Polepole 9 Mtr. Long W / L 200 Kgs 4 Muff For Steel Tubular Pole With Concrete Filling 5 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 6 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 7 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 8 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 9 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 10 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 11 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 12 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 13 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 14 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 15 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 16 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 17 D.O Fuse Unit 18 Surge Arrester, 9 Kv Station Class 19 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 20 Stay Set Complete 21 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 22 Pipe Earthing With Gi, Charcoal & Salt 23 Prov. Lt Distribution Panel With Mccb ( 100 A, 10 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63Kva Trf. As Per Specification 24 Half Clamp ( M.S. Flat 50X6 ) 25 Full Clamps ( M.S. Flat 50X6 ) 26 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed Wire ( Rec Sp F 3 / 1981 ) 31 Lt Cable 3-1 / 2 Core-95Mm Sq. 32 Alluminium Paint 33 Prov.Acsr, 6 / 1 / 3.35 Mm 34 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 35 Erection Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 36 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 37 Prov. St Polepole 9 Mtr. Long W / L 200 Kgs 38 Muff For Steel Tubular Pole With Concrete Filling 39 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 40 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 41 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 42 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 43 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 44 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 45 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 46 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 47 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 48 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 49 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 50 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 51 D.O Fuse Unit 52 Surge Arrester, 9 Kv Station Class 53 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 54 Stay Set Complete 55 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 56 Pipe Earthing With Gi, Charcoal & Salt 57 Prov. Lt Distribution Panel With Mccb ( 100 A, 10 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63Kva Trf. As Per Specification 58 Half Clamp ( M.S. Flat 50X6 ) 59 Full Clamps ( M.S. Flat 50X6 ) 60 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed Wire ( Rec Sp F 3 / 1981 ) 65 Lt Cable 3-1 / 2 Core-95Mm Sq. 66 Alluminium Paint 67 Prov.Acsr, 6 / 1 / 3.35 Mm 68 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 69 Supply Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.190Km ) 70 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 71 Prov. Steel Tubular Poles. 9Mtrs 72 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 73 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 74 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 75 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 76 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 77 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 78 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 79 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 80 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 81 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 82 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 83 Stay Wire ( 7 / 3.15 Mm ) ( 8.0 Kg Per Stay Set ) 84 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 85 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 86 Eye Hook For Earth Wire 87 Earth Wire Clamp 88 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 89 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 90 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 91 Danger Plate ( 250X200x1.6 Mm ) 92 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 93 Barbed Wire ( Rec Sp F 3 / 1981 ) 94 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 95 Alluminium Paint 96 Erection Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.190Km ) 97 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 98 Prov. Steel Tubular Poles. 9Mtrs 99 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 100 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 101 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 102 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 103 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 104 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 105 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 106 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 107 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 108 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 109 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 110 Stay Wire ( 7 / 3.15 Mm ) ( 8.0 Kg Per Stay Set ) 111 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 112 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 113 Eye Hook For Earth Wire 114 Earth Wire Clamp 115 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 116 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 117 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 118 Danger Plate ( 250X200x1.6 Mm ) 119 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 120 Barbed Wire ( Rec Sp F 3 / 1981 ) 121 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 122 Alluminium Paint 123 Supply Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 124 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 125 Prov. St Polepole 10 Mtr. Long W / L 200 Kgs 126 Muff For Steel Tubular Pole With Concrete Filling 127 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 128 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 129 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 130 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 131 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 132 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 133 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 134 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 135 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 136 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 137 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 138 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 139 D.O Fuse Unit 140 Surge Arrester, 9 Kv Station Class 141 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 142 Stay Set Complete 143 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 144 Pipe Earthing With Gi, Charcoal & Salt 145 Prov. Lt Distribution Panel With Mccb ( 100 A, 12 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63 Kva Trf. As Per Specification 146 Half Clamp ( M.S. Flat 50X6 ) 147 Full Clamps ( M.S. Flat 50X6 ) 148 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 149 Aluminium Thimbles 150 Copper Thimble 151 Danger Plate 152 Barbed Wire ( Rec Sp F 3 / 1981 ) 153 Lt Cable 3-1 / 2 Core-185Mm Sq. 154 Alluminium Paint 155 Prov.Acsr, 6 / 1 / 3.35 Mm 156 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 157 Erection Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 158 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 159 Prov. St Polepole 10 Mtr. Long W / L 200 Kgs 160 Muff For Steel Tubular Pole With Concrete Filling 161 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 162 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 163 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 164 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 165 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 166 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 167 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 168 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 169 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 170 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 171 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 172 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 173 D.O Fuse Unit 174 Surge Arrester, 9 Kv Station Class 175 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 176 Stay Set Complete 177 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 178 Pipe Earthing With Gi, Charcoal & Salt 179 Prov. Lt Distribution Panel With Mccb ( 100 A, 12 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63 Kva Trf. As Per Specification 180 Half Clamp ( M.S. Flat 50X6 ) 181 Full Clamps ( M.S. Flat 50X6 ) 182 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 183 Aluminium Thimbles 184 Copper Thimble 185 Danger Plate 186 Barbed Wire ( Rec Sp F 3 / 1981 ) 187 Lt Cable 3-1 / 2 Core-185Mm Sq. 188 Alluminium Paint 189 Prov.Acsr, 6 / 1 / 3.35 Mm 190 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 191 Supply Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.230 Km ) 192 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 193 Prov. Steel Tubular Poles. 9Mtrs 194 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 195 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 196 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 197 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 198 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 199 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 200 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 201 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 202 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 203 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 204 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 205 Stay Wire ( 7 / 3.15 Mm ) ( 9.0 Kg Per Stay Set ) 206 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 207 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 208 Eye Hook For Earth Wire 209 Earth Wire Clamp 210 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 211 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 212 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 213 Danger Plate ( 250X200x1.6 Mm ) 214 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 215 Barbed Wire ( Rec Sp F 3 / 1981 ) 216 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 217 Alluminium Paint 218 Erection Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.230 Km ) 219 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 220 Prov. Steel Tubular Poles. 9Mtrs 221 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 222 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 223 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 224 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 225 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 226 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 227 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 228 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 229 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 230 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 231 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 232 Stay Wire ( 7 / 3.15 Mm ) ( 9.0 Kg Per Stay Set ) 233 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 234 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 235 Eye Hook For Earth Wire 236 Earth Wire Clamp 237 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 238 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 239 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 240 Danger Plate ( 250X200x1.6 Mm ) 241 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 242 Barbed Wire ( Rec Sp F 3 / 1981 ) 243 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 244 Alluminium Paint

Key Value

Document Fees
INR 590 /-
EMD
INR 11280.0 /-
Tender Value
INR 11.28 Lakhs /-

BOQ Items

Name of Work: (i)Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to JSV, LWSST/Well at Minjgran by Prov. 11/.4 KV 63 KVA S/Stn.a/w 11 KV HT section Nurpur under ESD Nurpur ED Nurpur ( T.S. No. 102/22-23 )(ii) Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to LWSS Chhatroli by Prov. 11/.4 KV 63 KVA S/Stn. at Chhatroli (Batu-Ka-Nalah) a/w 11 KV HTlinesection Jassure under ESD Nurpur ED Nurpur ( T.S. No. 101/22-23 )
Sl. No. Item Description
1Supply part of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION
211/.4 KV 63KVA DTR (REC Sep. ord 11/1976
3Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs
4Muff for steel tubular pole with concrete filling
5X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
6MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
7X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
8X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
9X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
10MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
11MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
12MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
13MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
14MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
15G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
16G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
17D.O Fuse unit
18Surge Arrester, 9 kV Station Class
19Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
20Stay set complete
21Staywire (7/3.15mm)( 10 Kg per stay set)
22Pipe earthing with GI,Charcoal & Salt
23Prov. LT distribution panel with MCCB (100 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63KVA Trf. as per specification
24Half clamp (M.S. Flat 50x6)
25Full clamps (M.S. Flat 50x6)
26M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
27Aluminium Thimbles
28Copper Thimble
29Danger Plate
30Barbed wire (REC Sp F 3/1981)
31LT Cable 3-1/2 core-95mm sq.
32Alluminium Paint
33Prov.ACSR, 6/1/3.35 mm
34Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
35Erection part of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION
3611/.4 KV 63KVA DTR (REC Sep. ord 11/1976
37Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs
38Muff for steel tubular pole with concrete filling
39X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
40MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
41X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
42X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
43X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
44MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
45MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
46MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
47MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
48MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
49G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
50G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
51D.O Fuse unit
52Surge Arrester, 9 kV Station Class
53Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
54Stay set complete
55Staywire (7/3.15mm)( 10 Kg per stay set)
56Pipe earthing with GI,Charcoal & Salt
57Prov. LT distribution panel with MCCB (100 A, 10 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63KVA Trf. as per specification
58Half clamp (M.S. Flat 50x6)
59Full clamps (M.S. Flat 50x6)
60M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
61Aluminium Thimbles
62Copper Thimble
63Danger Plate
64Barbed wire (REC Sp F 3/1981)
65LT Cable 3-1/2 core-95mm sq.
66Alluminium Paint
67Prov.ACSR, 6/1/3.35 mm
68Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
69Supply Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.190KM)
70ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
71Prov. Steel tubular poles. 9mtrs
72Muff for steel tubular pole (2000mm long) with concrete filling
73Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
74Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
75Pole Top Bracket [MSCI:100x50x6mm-100mm]
7611 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
77Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
78X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
79X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
80Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
8111 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
82Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
83Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
84HT earthing set complete (REC Constr. Standared J-1)
85Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
86Eye Hook for earth wire
87Earth Wire Clamp
88MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
89Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
90Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
91Danger Plate (250X200X1.6 mm)
92M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
93Barbed wire (REC Sp F 3/1981)
94G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
95Alluminium Paint
96Erection Part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.190KM)
97ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
98Prov. Steel tubular poles. 9mtrs
99Muff for steel tubular pole (2000mm long) with concrete filling
100Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
101Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
102Pole Top Bracket [MSCI:100x50x6mm-100mm]
10311 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
104Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
105X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
106X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
107Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
10811 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
109Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
110Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set)
111HT earthing set complete (REC Constr. Standared J-1)
112Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
113Eye Hook for earth wire
114Earth Wire Clamp
115MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
116Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
117Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
118Danger Plate (250X200X1.6 mm)
119M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
120Barbed wire (REC Sp F 3/1981)
121G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
122Alluminium Paint
123Supply part of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION
12411/.4 KV 63KVA DTR (REC Sep. ord 11/1976
125Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs
126Muff for steel tubular pole with concrete filling
127X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
128MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
129X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
130X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
131X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
132MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
133MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
134MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
135MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
136MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
137G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
138G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
139D.O Fuse unit
140Surge Arrester, 9 kV Station Class
141Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
142Stay set complete
143Staywire (7/3.15mm)( 10 Kg per stay set)
144Pipe earthing with GI,Charcoal & Salt
145Prov. LT distribution panel with MCCB (100 A, 12 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification
146Half clamp (M.S. Flat 50x6)
147Full clamps (M.S. Flat 50x6)
148M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
149Aluminium Thimbles
150Copper Thimble
151Danger Plate
152Barbed wire (REC Sp F 3/1981)
153LT Cable 3-1/2 core-185mm sq.
154Alluminium Paint
155Prov.ACSR, 6/1/3.35 mm
156Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
157Erection part of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION
15811/.4 KV 63KVA DTR (REC Sep. ord 11/1976
159Prov. ST PolePole 10 Mtr. Long W/L 200 Kgs
160Muff for steel tubular pole with concrete filling
161X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line
162MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LA"s )
163X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
164X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed
165X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer]
166MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No.
167MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
168MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing
169MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
170MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly
171G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly
172G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
173D.O Fuse unit
174Surge Arrester, 9 kV Station Class
175Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
176Stay set complete
177Staywire (7/3.15mm)( 10 Kg per stay set)
178Pipe earthing with GI,Charcoal & Salt
179Prov. LT distribution panel with MCCB (100 A, 12 KA, 4P,1 No.) & SFU (32 A 4 No. rewireble) for 63 KVA Trf. as per specification
180Half clamp (M.S. Flat 50x6)
181Full clamps (M.S. Flat 50x6)
182M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
183Aluminium Thimbles
184Copper Thimble
185Danger Plate
186Barbed wire (REC Sp F 3/1981)
187LT Cable 3-1/2 core-185mm sq.
188Alluminium Paint
189Prov.ACSR, 6/1/3.35 mm
190Prov.63KVA S/Stn structure protection a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
191Supply part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.230 KM)
192ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
193Prov. Steel tubular poles. 9mtrs
194Muff for steel tubular pole (2000mm long) with concrete filling
195Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
196Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
197Pole Top Bracket [MSCI:100x50x6mm-100mm]
19811 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
199Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
200X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
201X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
202Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
20311 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
204Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
205Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set)
206HT earthing set complete (REC Constr. Standared J-1)
207Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
208Eye Hook for earth wire
209Earth Wire Clamp
210MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
211Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
212Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
213Danger Plate (250X200X1.6 mm)
214M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
215Barbed wire (REC Sp F 3/1981)
216G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
217Alluminium Paint
218Erection part of HT LINE WITH ACSR 6/1/3.35 mm sq. ON STEEL POLES (0.230 KM)
219ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage}
220Prov. Steel tubular poles. 9mtrs
221Muff for steel tubular pole (2000mm long) with concrete filling
222Cross Arm: [Channel Iron (100x50x6 mm), Length 1270 mm (i/c tolerence of 100mm either side) x2 structure( Run Through structure (Formation Tringle)
223Angle Iron (50x50x5 mm), Length (2x750) mm x 1 structures (Run Through structure (Formation Tringle)
224Pole Top Bracket [MSCI:100x50x6mm-100mm]
22511 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure (Run Through structure (Formation Tringle)
226Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures
227X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures
228X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures
229Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures
23011 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures
231Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.)
232Stay Wire (7/3.15 mm) (9.0 kg Per Stay Set)
233HT earthing set complete (REC Constr. Standared J-1)
234Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
235Eye Hook for earth wire
236Earth Wire Clamp
237MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch
238Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
239Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.)
240Danger Plate (250X200X1.6 mm)
241M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer)
242Barbed wire (REC Sp F 3/1981)
243G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type
244Alluminium Paint
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail